FLFangfang Liu

Fangfang Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Fangfang Liu has a total of 48 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Wearable optical fiber multimodal sensing flexible skin for monitoring omnidirectional bending posture of human joint motions

    by Ying Jiang, Fangfang Liu, Wenhao Yang, Han Zheng, Chennan Yang, Huining Zhao, Hongli Li, Haojie Xia

    Flexible sensing skin, based on bionic mechanical properties and multi-functional perception capabilities, can measure multi-dimensional mechanical parameters such as stretching, pressure, and bending, overcoming the limitations of traditional rigid sensors in complex curved surfaces and dynamic deformation scenarios. The core challenge in using flexible bionic skin for measurement lies in solving the problem of multi-modal parameter coupling. This paper proposes a flexible skin array composed of three sensing skin units for omnidirectional bend monitoring based on Bragg fiber gratings, which realizes the decoupling and synchronous measurement between touch force and full-circumferential bending vector. Experimental tests of the sensing skin unit with the optimal mechanical parameters, show sensitivity of the skin unit for the touch force is 0.02824 nm N −1 , with a repeatability error of 5.15%, and sensitivity for the bending curvature is 0.0084 nm mm −1 , with a repeatability error of 2.62%. Furthermore, the full-circumferential skin array was fabricated to conduct application tests for touch force and bending posture on the human wrist joint. The experimental results demonstrate that the skin unit located on the human wrist joint can achieve high-precision decoupling results between touch force and bending curvature. Simultaneously, the omnidirectional skin array around the human wrist can accurately measure bending direction angles and curvatures of the wrist joint. The developed multimodal sensing and decoupling flexible skin has the significant advantages and potential of simple structure and low manufacturing cost, and has great application value and market prospects in the fields of human health monitoring detection and bionic robots.

  • Illuminating the interface: unveiling novel interfacial effects of a structurally distinctive truncated conical probe

    by Fangfang Liu, Chuanliang Gao, Long Ling, Xiaolei Niu, Heyin Zhou, Wei Zhou, Huining Zhao, Hongli Li, Lei Yang, Haojie Xia

  • Adhesion Force Evolution Mediated by Capillary Condensation under Varied Macroscopic Humidity or Interface Micromorphology: Measurement via Micrometer-Scale Probe

    by Fangfang Liu, Long Ling, Chuanliang Gao, Xiaolei Niu, Xinyang Liu, Hongli Li, Huining Zhao, Lei Yang, Haojie Xia

    With the structure and device entering the micro/nanoscale, the interaction between microdevices is mainly governed by the interface forces. The capillary adhesion force, as the main component of the interface force, significantly affects the detection accuracy and reliability of the micro/nanomeasurement system. In this paper, an accurate and directly parametrized theoretical model of the capillary force related to relative humidity, as well as a model with respect to surface roughness derived from a sinusoidal characteristic microtopography under the partially infiltrated state of surface microcosmic grooves, is established, which can more accurately describe the capillary adhesion behavior between real workpiece surfaces. A high-sensitivity force measurement system using the probe tip on a micrometer scale is developed to measure capillary forces. The experimental results demonstrate the accuracy of the theoretical models and reveal the relationship between effective distance, rate of change of the capillary force with the relative humidity, or surface roughness. This work will expand the scope of understanding of the interaction effects appearing on micrometer-scale probe tips and lead to many potential applications of the interface interaction in micro- and nanotechnology.

  • Heterogeneous-Sensing Bionic Skin for 3-D Force-Vector Measurement and Slip Characterization

    by Fangfang Liu, Chennan Yang, Wenhao Yang, Shizhao Li, Han Zheng, Huining Zhao, Hongli Li, Haojie Xia

    With the rapid development of flexible electronics and smart sensing technology, electronic skin has attracted increasing attention from academia and industry as a bionic sensing system. This paper presents a biomimetic skin system that integrates heterogeneous fiber Bragg grating (FBG) distribution with a bionic fingerprint structure to enable high-precision detection and identification of three-dimensional force vectors and slip states. The system eliminates the need for additional temperature-compensation components, while still effectively reducing the impact of environmental temperature variations. Experimental results demonstrate that the proposed system exhibits good linear response characteristics for both normal and shear force measurements. The normal force measurement range is 0-5 N, with a resolution of 0.042 N and a sensitivity of 1.54 V/N. The resolution of the X-direction shear force is 0.023 N with a sensitivity of 3.79 V/N, while the Y-direction shear force achieves a resolution of 0.012 N and a sensitivity of 7.78 V/N. Furthermore, a Random Forest (RF) algorithm is applied to train and classify slip signals, which enables prediction accuracies exceeding 97.2% for slip direction and velocity. These results provide new insights and methods for improving the performance and expanding the functionality of electronic skin technology, supporting its broader application in intelligent sensing.

  • Open Access

    Simultaneous measurement of five-degree-of-freedoms error motion of rotary axis based on multi-principle fusion method

    by Huining Zhao, Jie Wang, Hu Sun, Fangfang Liu, Haojie Xia

    This paper proposes a method for the simultaneous measurement of five-degree-of-freedoms error motions of a rotary axis based on multi-principle fusion, including the curved edge diffraction principle, auto-collimation principle, and laser triangulation principle. The proposed measurement system comprises laser sources, beam splitters, a right-angle mirror, photodiode detectors (PDs), a plane mirror, four-quadrant PDs, and mechanical structures. Mathematical models are established for these three optical measurement methods. The calibration results indicate that the radial displacement residual range is ±0.38 μm within a measurement range of ±30 μm, the axial displacement residual range is ±0.46 μm within ±20 μm, and the tilt angle residual range is ±0.40 arcsec within ±50 arcsec. Experimental tests conducted on a DD motor show that the radial error motion range is −0.727–0.644 μm, the axial error motion range is −4.053–5.876 μm, and the tilt error motion ranges around X-axis is −2.728–4.851 arcsec and around Y-axis is −4.728–3.872 arcsec, respectively.


  • 3D measurement of precise part in complex circumstance using line structured light and improved U-Net

    by Huining Zhao, Yongbo Huang, Maosen Wan, Liandong Yu, Fangfang Liu, Haojie Xia

    Line structured light scanning is extensively utilized for the 3D measurement of precise metal parts, but the curvature surfaces and specific materials of these parts generate specular reflection, making it challenging to accurately extract the center of the laser stripe in complex circumstances. Therefore, the primary challenges are the noise separation in the laser stripe image and the extraction of the laser stripe center under complex circumstances. To solve the above problems, an improved U-Net semantic segmentation algorithm is proposed by adding an attention mechanism and modifying skip connections to the classical U-Net network structure for accurate laser stripe segmentation. Secondly, the dual smoothing method of mean smoothing and Savitzky–Golay smoothing is combined with the Hessian matrix algorithm to complete the subpixel extraction of the center point of the laser stripe. Finally, taking the blade and shaft part as the measurement objects, the experimental results demonstrate that the method can obtain more complete, smoother, and denser results than the traditional method under highly reflective surfaces, vital interference spots, and strong ambient light. The proposed method is used for the 3D measurement of the shaft parts, and the diameter measurement maximum error is 0.029 mm, verifying the feasibility of the proposed method.


  • Multiparameter measurement depending on the cavity-length differentiation characteristics of a microfiber Fabry–Perot interferometer

    by Fangfang Liu, Xin Ran, Xinyang Liu, Ying Jiang, Pen Yan, Shizhao Li, Hongli Li, Huining Zhao, Haojie Xia

    To solve the cross-sensitivity problem affecting optical fiber sensors and realize multiparameter measurement, a microfiber Fabry–Perot interferometer (MFPI) is proposed and experimentally demonstrated. Simultaneous measurement of two distinct physical parameter (temperature and strain) is realized by monitoring wavelength and reflectivity of MFPI. In the temperature field range of 22 °C–36 °C, the maximum temperature sensitivity can reach 12 pm °C−1. The maximum strain sensitivity is up to 0.8 pm/μϵ in the strain range of 0–800 μϵ. In the simultaneous measurement experiments, the relative errors of temperature and strain were 4.0% and 0.8%, respectively. Furthermore, the sensing element used in this method was just a single fiber grating sensor without any coating layer, which demonstrated the significant advantage of the proposed method in reducing the complexity and cost of multiparameter measurement.


  • Open Access

    Deep understanding of the dependence between capillary adhesion behavior and meniscus Kelvin radius or interface micromorphology

    by Fangfang Liu, Xinyang Liu, Xin Ran, Hongli Li, Huining Zhao, Lei Yang, Haojie Xia

    With the structure and device entering the micro/nano scale, the interaction between micro devices is mainly governed by the interface forces. The capillary adhesion force, as the main component of the interface force, significantly affects the detection accuracy and reliability of the micro/nano measurement system. In this paper, an accurate parameterized theoretical model of the capillary force related to relative humidity considering a non-constant Kelvin equilibrium radius, as well as a model with respect to surface roughness derived from a sinusoidal characteristic microtopography under the partially infiltrated state of surface microcosmic grooves are established which can more accurately describe the capillary adhesion behavior between real workpiece surfaces. A high-sensitivity force measurement system using the probe tip on micrometre scale is developed to measure capillary forces. The experiment results demonstrate the accuracy of the theoretical models and reveal the relationship between effective distance, rate of change of the capillary force with the relative humidity or surface roughness. This work will expand the scope of understanding of the interaction effects appeared on micrometer-scale probe tips and lead to many potential applications of the interface interaction in micro- and nanotechnology.

  • The Observation of Interface Effects Presented on Micrometer-Scale Sphere Tips of Fiber Bragg Grating-Based Probes

    by Fangfang Liu, Zihan Yang, Fanghui Lin, Rongmin Zhao, Hongli Li, Haojie Xia

    The interface effects between microstructural bodies become more and more important as micromechanical and microfluidic devices enter sub-micrometer- scale. Scanning probe microscopes like atomic force microscopy are the most significant tools for detecting the interface forces, where the dimension of the cantilever tips is on nanometer-scale. In this work, we present a fiber Bragg grating-based interface force measurement method for micrometer-size probe tips and detailed measurements conducted with various sample surfaces, tip radius and medium environments. The experimental and numerical results unambiguously reveal that probes with micrometer-size tips are more easily influenced by interface interaction, and forces show varying magnitudes, action ranges and prioritized contributions, compared with nano-size probe tips. In addition, the interface force measurement approach could help to find the contact zero-point when the probe approaches and contacts the measured surface, and understand surface characteristics of materials as well. This work could lead to many potential applications of the interface interaction in micro- and nano-technology using micrometer-scale probe tips.


  • Development and characterization of a high-sensitivity fiber Bragg grating-based vibrating nano-probe for 3D measurement

    by Fangfang Liu, Jingfan Wang, Lijuan Chen, Ruijun Li, Haojie Xia, Liandong Yu

    Purpose: There is an increasing demand for higher-accuracy dimensional measurements of nano- and micro-structures. Recently, the authors presented a fiber Bragg grating (FBG) sensor-based dynamic nano-coordinate-measuring machine (CMM) probe for true three-dimensional coordinate measurement, in which a specific mechanical structure with several FBG sensors was developed to provide the probe with sensitivity to loading in all directions. Design/methodology/approach: The study presents a three-dimensional sensing and demodulation system based on an improved matched filter design and the time division multiplexing technique that helps solve the problem of multiplex FBG-signals conflicts. In addition, the application of the dynamic mode of the probe system effectively solves the problem presented by the surface interaction forces. Findings: Consequently, this FBG-based vibrating probe system has increased sensitivity to strain, while maintaining smaller contact force. The experiments for testing probe performance show that the prototype yielded a measurement resolution of 13 nm, a repeatability of 50 nm and a vertical measurement force of less than1.5 mN. Research limitations/implications: The force tests in the horizontal directions are difficult to conduct because both the probe and the dynamometer are only adaptable to vertical use. Practical implications: Development of the FBG-based dynamic nano-coordinate-measuring machine probe will achieve a new and inexpensive method for higher-accuracy dimensional measurements of nano- and micro-structures, such as micro-electromechanical systems, micro-fluidic chips, inkjet and diesel engine injector nozzles that are in overall dimensions within the micrometer scale. Originality/value: The study presents a three-dimensional sensing and demodulation system for the vibrating nano-coordinate-measuring machine probe based on FBG sensors. The prototype yielded a measurement resolution of 13 nm, a repeatability of 50 nm and a vertical measurement force of less than1.5 mN.