Dahu Li
Research Subjects
Dahu Li has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Jun He
Affiliation Hubei Collaborative Innovation Center for High-Efficiency Utilization of Solar Energy, Hubei University of Technology, Wuhan, China
2 shared publications - Wentao Huang
Affiliation School of Electrical and Electronic Engineering, Hubei University of Technology, Wuhan, Hubei, China
2 shared publications - Chenghao Li
Electric Power Research Institute, State Grid Henan Electric Power Company, Zhengzhou 450052, China
1 shared publication - Dong Wang
State Key Laboratory of Green Chemical Engineering and Industrial Catalysis Centre for Computational Chemistry and Research Institute of Industrial Catalysis, School of Chemistry and Molecular Engineering East China University of Science and Technology 130 Meilong Road Shanghai 200237 P. R. China
1 shared publication - Feng Zhang
School of Earth Sciences, Zhejiang University, Hangzhou 310058, China
1 shared publication Huoping Zhao
School of Physical Education, Longdong University, Qingyang 745000, China
1 shared publication
Latest Publications
- Open Access
- 27 February 2022
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 2022, 1-18
Interaction Mechanism and Coordinated Control of Commutation Failure Prevention in Multi-Infeed Ultra-HVDC System
Commutation failure (CF) is an inherent drawback of line-commutated converter high-voltage DC (LCC-HVDC) system. And CF prevention (CFPREV) control is widely applied in UHVDC lines to mitigate the subsequent CF. However, the formation of a multi-infeed UHVDC system induces power exchange and voltage interaction between AC buses during the transient process, making the behaviors and mitigation of CFs more complex. Consequently, exploring the impact of CFPREV control on adjacent stations and optimizing the CFPREV control to adapt to the interaction characteristics in a multi-infeed system is necessary. Considering the interaction characteristics, the impact of CFPREV control on the commutation process of inverters in a multi-infeed system is analyzed through formula derivation and simulation verification. It is found that although CFPREV control can effectively mitigate the CFs of the inverter near the fault, it will further increase the risk of concurrent CF (CCF) of remote inverters due to the interaction on the AC side. To solve this problem, a coordinated control scheme of CFPREV controls in a multi-infeed UHVDC system is proposed. The output of the CFPREV control of the inverter near the fault can be adjusted adaptively according to the commutation margins of remote inverters. And the probability of CCF caused by CFPREV control is consequently decreased. Case studies are conducted based on Henan provincial multi-infeed UHVDC system in China to verify the analysis result and the effectiveness of the coordinated control scheme of CFPREV controls.
- 27 February 2022
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 2022, 1-18
Open AccessInteraction Mechanism and Coordinated Control of Commutation Failure Prevention in Multi-Infeed Ultra-HVDC System
Commutation failure (CF) is an inherent drawback of line-commutated converter high-voltage DC (LCC-HVDC) system. And CF prevention (CFPREV) control is widely applied in UHVDC lines to mitigate the subsequent CF. However, the formation of a multi-infeed UHVDC system induces power exchange and voltage interaction between AC buses during the transient process, making the behaviors and mitigation of CFs more complex. Consequently, exploring the impact of CFPREV control on adjacent stations and optimizing the CFPREV control to adapt to the interaction characteristics in a multi-infeed system is necessary. Considering the interaction characteristics, the impact of CFPREV control on the commutation process of inverters in a multi-infeed system is analyzed through formula derivation and simulation verification. It is found that although CFPREV control can effectively mitigate the CFs of the inverter near the fault, it will further increase the risk of concurrent CF (CCF) of remote inverters due to the interaction on the AC side. To solve this problem, a coordinated control scheme of CFPREV controls in a multi-infeed UHVDC system is proposed. The output of the CFPREV control of the inverter near the fault can be adjusted adaptively according to the commutation margins of remote inverters. And the probability of CCF caused by CFPREV control is consequently decreased. Case studies are conducted based on Henan provincial multi-infeed UHVDC system in China to verify the analysis result and the effectiveness of the coordinated control scheme of CFPREV controls.
- Open Access
- 7 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 56264-56276
Optimal Planning Method for Power System Line Impedance Based on a Comprehensive Stability Margin
With the increasing scale of power systems and the large-scale application of new energy technologies, the planning and construction of future power grids and the stable operation of systems face severe challenges. Among them, transient stability and short-circuit current are two key factors that determine the safe and stable operation of a power system. However, in traditional power-grid planning, there is little research on the strategy of coordinating the solution between transient stability, short-circuit current problems and planning forecasts. Based on the perspective of power-grid planning, this study proposes a method for the optimal planning of a power system’s comprehensive stability margin that uses the external penalty function method. The coupling relationship between the transient stability margin and short-circuit current margin is developed through the system impedance in power-grid planning, and the line impedance optimization planning problem based on the comprehensive stability margin is formulated as a multiobjective optimization model. Finally, the optimal system impedance and the optimal comprehensive stability margin are determined by the external penalty function method. The simulation results of an IEEE 10-generator 39-bus system verify the effectiveness of the proposed method, and the system with the optimal planned impedance determined by this method yields the best comprehensive stability margin. Further simulation verification is conducted in a real power grid in China, and the strategy proposed in this article exhibits good economy and scalability. It provides a theoretical basis for the planning and construction of the future power grid, which is conducive to the safe and stable operation of the future power grid.
- 7 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 56264-56276
Open AccessOptimal Planning Method for Power System Line Impedance Based on a Comprehensive Stability Margin
With the increasing scale of power systems and the large-scale application of new energy technologies, the planning and construction of future power grids and the stable operation of systems face severe challenges. Among them, transient stability and short-circuit current are two key factors that determine the safe and stable operation of a power system. However, in traditional power-grid planning, there is little research on the strategy of coordinating the solution between transient stability, short-circuit current problems and planning forecasts. Based on the perspective of power-grid planning, this study proposes a method for the optimal planning of a power system’s comprehensive stability margin that uses the external penalty function method. The coupling relationship between the transient stability margin and short-circuit current margin is developed through the system impedance in power-grid planning, and the line impedance optimization planning problem based on the comprehensive stability margin is formulated as a multiobjective optimization model. Finally, the optimal system impedance and the optimal comprehensive stability margin are determined by the external penalty function method. The simulation results of an IEEE 10-generator 39-bus system verify the effectiveness of the proposed method, and the system with the optimal planned impedance determined by this method yields the best comprehensive stability margin. Further simulation verification is conducted in a real power grid in China, and the strategy proposed in this article exhibits good economy and scalability. It provides a theoretical basis for the planning and construction of the future power grid, which is conducive to the safe and stable operation of the future power grid.
- Open Access
- 1 March 2021
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 714 (3) , 032042
Research and analysis of maximum likelihood recursive identification algorithm based on physical exercise behavior of obese children
With the decrease of physical activity, children’s health problem will become an urgent problem in building a well-off society in an all-round way. There are differences in the safe heart rate of children with different physique when they exercise.This paper studies the suitable heart rate of children with different physique. Based on a maximum likelihood recursive algorithm for obese children’s physical exercise behavior, a model recognition system based on the maximum likelihood recursive algorithm for obese children’s physical exercise behavior is established. Finally, through MATLAB simulation analysis, the results show that fat the model recognition of MLR algorithm is consistent with the actual results, and the simulation results verify the feasibility and effectiveness of MLR algorithm.
- 1 March 2021
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 714 (3) , 032042
Open AccessResearch and analysis of maximum likelihood recursive identification algorithm based on physical exercise behavior of obese children
With the decrease of physical activity, children’s health problem will become an urgent problem in building a well-off society in an all-round way. There are differences in the safe heart rate of children with different physique when they exercise.This paper studies the suitable heart rate of children with different physique. Based on a maximum likelihood recursive algorithm for obese children’s physical exercise behavior, a model recognition system based on the maximum likelihood recursive algorithm for obese children’s physical exercise behavior is established. Finally, through MATLAB simulation analysis, the results show that fat the model recognition of MLR algorithm is consistent with the actual results, and the simulation results verify the feasibility and effectiveness of MLR algorithm.
- 1 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1761-1766
Comprehensive Evaluation of Microgrid Planning Scheme based on AHP- Entropy method
Microgrid has the advantages of low carbon, energy saving and economy. The development direction of distribution network is distribution network with microgrid. In order to evaluate the rationality of microgrid planning comprehensively and scientifically, this paper establishes a comprehensive evaluation index system of microgrid from four aspects: economy, reliability, basic structure of planning and environmental protection. In order to overcome the subjectivity of simple Analytic hierarchy process (AHP), AHP- entropy method is introduced to configure the weights of microgrid indexes, and a comprehensive evaluation method of microgrid planning scheme based on AHP- entropy method is proposed for the first time. Finally, an example of an island microgrid in Zhuhai is taken to verify the feasibility of the proposed method.
- 1 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1761-1766
Comprehensive Evaluation of Microgrid Planning Scheme based on AHP- Entropy method
Microgrid has the advantages of low carbon, energy saving and economy. The development direction of distribution network is distribution network with microgrid. In order to evaluate the rationality of microgrid planning comprehensively and scientifically, this paper establishes a comprehensive evaluation index system of microgrid from four aspects: economy, reliability, basic structure of planning and environmental protection. In order to overcome the subjectivity of simple Analytic hierarchy process (AHP), AHP- entropy method is introduced to configure the weights of microgrid indexes, and a comprehensive evaluation method of microgrid planning scheme based on AHP- entropy method is proposed for the first time. Finally, an example of an island microgrid in Zhuhai is taken to verify the feasibility of the proposed method.