Chenghao Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chenghao Li has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Dahu Li
Smart Grid Hubei Electric Power Company Limited, Wuhan 430077, China
1 shared publication - Jinyu Wen
Huazhong University of Science and Technology
1 shared publication - Lingrao Wang
North China Branch of State Grid Corporation of China, Beijing, China
1 shared publication - Wei Yao
Huazhong University of Science and Technology
1 shared publication - Yangchen Tan
Northwest Branch of State Grid Corporation of China, Xian 710048, China
1 shared publication - Yongxin Xiong
Hong Kong Polytechnic University, Hong Kong, China
1 shared publication
Latest Publications
- Open Access
- 27 February 2022
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 2022, 1-18
Interaction Mechanism and Coordinated Control of Commutation Failure Prevention in Multi-Infeed Ultra-HVDC System
Commutation failure (CF) is an inherent drawback of line-commutated converter high-voltage DC (LCC-HVDC) system. And CF prevention (CFPREV) control is widely applied in UHVDC lines to mitigate the subsequent CF. However, the formation of a multi-infeed UHVDC system induces power exchange and voltage interaction between AC buses during the transient process, making the behaviors and mitigation of CFs more complex. Consequently, exploring the impact of CFPREV control on adjacent stations and optimizing the CFPREV control to adapt to the interaction characteristics in a multi-infeed system is necessary. Considering the interaction characteristics, the impact of CFPREV control on the commutation process of inverters in a multi-infeed system is analyzed through formula derivation and simulation verification. It is found that although CFPREV control can effectively mitigate the CFs of the inverter near the fault, it will further increase the risk of concurrent CF (CCF) of remote inverters due to the interaction on the AC side. To solve this problem, a coordinated control scheme of CFPREV controls in a multi-infeed UHVDC system is proposed. The output of the CFPREV control of the inverter near the fault can be adjusted adaptively according to the commutation margins of remote inverters. And the probability of CCF caused by CFPREV control is consequently decreased. Case studies are conducted based on Henan provincial multi-infeed UHVDC system in China to verify the analysis result and the effectiveness of the coordinated control scheme of CFPREV controls.
- 27 February 2022
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 2022, 1-18
Open AccessInteraction Mechanism and Coordinated Control of Commutation Failure Prevention in Multi-Infeed Ultra-HVDC System
Commutation failure (CF) is an inherent drawback of line-commutated converter high-voltage DC (LCC-HVDC) system. And CF prevention (CFPREV) control is widely applied in UHVDC lines to mitigate the subsequent CF. However, the formation of a multi-infeed UHVDC system induces power exchange and voltage interaction between AC buses during the transient process, making the behaviors and mitigation of CFs more complex. Consequently, exploring the impact of CFPREV control on adjacent stations and optimizing the CFPREV control to adapt to the interaction characteristics in a multi-infeed system is necessary. Considering the interaction characteristics, the impact of CFPREV control on the commutation process of inverters in a multi-infeed system is analyzed through formula derivation and simulation verification. It is found that although CFPREV control can effectively mitigate the CFs of the inverter near the fault, it will further increase the risk of concurrent CF (CCF) of remote inverters due to the interaction on the AC side. To solve this problem, a coordinated control scheme of CFPREV controls in a multi-infeed UHVDC system is proposed. The output of the CFPREV control of the inverter near the fault can be adjusted adaptively according to the commutation margins of remote inverters. And the probability of CCF caused by CFPREV control is consequently decreased. Case studies are conducted based on Henan provincial multi-infeed UHVDC system in China to verify the analysis result and the effectiveness of the coordinated control scheme of CFPREV controls.