Stephan Uebel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Stephan Uebel has a total of 129 co-authors. Here are the top co-authors by number of shared publications:
- Blanca Lopez Mendez
Novo Nordisk Foundation Center for Protein Research, University of Copenhagen, Copenhagen, Denmark
5 shared publications - Alexander Kai Buell
Department of Biotechnology and Biomedicine, Technical University of Denmark, Kgs. Lyngby, Denmark
3 shared publications - Arthur Sedivy
ProteinTechnology, Vienna Biocenter Core Facilities GmbH, Vienna, Austria
3 shared publications - Daumantas Matulis
Department of Biothermodynamics and Drug Design, Institute of Biotechnology, Life Sciences Center Vilnius University Vilnius Lithuania
3 shared publications - Josef Houser
CEITEC, Masaryk University, Brno, Czech Republic
3 shared publications - Maria Garcia Alai
European Molecular Biology Laboratory, Hamburg Outstation, Hamburg, Germany
3 shared publications
Latest Publications
- Open Access
Interlaboratory benchmarking of differential scanning fluorimetry reveals sources of variability in protein thermal stability parameters
Differential scanning fluorimetry (DSF) is widely used to assess protein thermal stability and to compare protein variants, ligands, or formulations with limited sample consumption. Yet, the reproducibility of DSF-derived parameters across laboratories, instruments and analysis workflows remains poorly defined. Here, we report a two-phase interlaboratory benchmark using a shared V H H sample across 26 laboratories, 28 instruments and seven DSF instrument models. In Phase 1, participants applied their routine acquisition and analysis workflows, whereas in Phase 2, acquisition conditions were harmonised. Datasets were analysed locally and then centrally reprocessed with MoltenProt. Participant-reported apparent melting temperatures ( T m ) showed good within-instrument repeatability but moderate inter-instrument dispersion. Harmonisation of acquisition conditions did not substantially reduce this dispersion. Conversely, centralised reprocessing narrowed the distribution among retained datasets, indicating contributions from analysis workflows and data-acceptance criteria in addition to instrument-dependent factors. Comparison with differential scanning calorimetry (DSC) further showed that apparent T m depended strongly on the fluorescence readout. For this V H H, single-wavelength fluorescence at 350 nm showed the closest agreement with the DSC transition temperature, whereas the 350/330 nm ratio and barycentric mean generally yielded higher values. Furthermore, DSF-derived apparent unfolding enthalpies were more variable than apparent T m . Together, these findings show that DSF can be highly repeatable within a defined instrument and workflow, but that quantitative comparability across instruments depends on instrument-specific effects, the choice of fluorescence readout and analysis strategy. Improved comparability will require transparent reporting of acquisition and analysis conditions, explicit data-quality criteria, and well-characterised reference materials to monitor instrument-dependent offsets.
Open AccessInterlaboratory benchmarking of differential scanning fluorimetry reveals sources of variability in protein thermal stability parameters
Differential scanning fluorimetry (DSF) is widely used to assess protein thermal stability and to compare protein variants, ligands, or formulations with limited sample consumption. Yet, the reproducibility of DSF-derived parameters across laboratories, instruments and analysis workflows remains poorly defined. Here, we report a two-phase interlaboratory benchmark using a shared V H H sample across 26 laboratories, 28 instruments and seven DSF instrument models. In Phase 1, participants applied their routine acquisition and analysis workflows, whereas in Phase 2, acquisition conditions were harmonised. Datasets were analysed locally and then centrally reprocessed with MoltenProt. Participant-reported apparent melting temperatures ( T m ) showed good within-instrument repeatability but moderate inter-instrument dispersion. Harmonisation of acquisition conditions did not substantially reduce this dispersion. Conversely, centralised reprocessing narrowed the distribution among retained datasets, indicating contributions from analysis workflows and data-acceptance criteria in addition to instrument-dependent factors. Comparison with differential scanning calorimetry (DSC) further showed that apparent T m depended strongly on the fluorescence readout. For this V H H, single-wavelength fluorescence at 350 nm showed the closest agreement with the DSC transition temperature, whereas the 350/330 nm ratio and barycentric mean generally yielded higher values. Furthermore, DSF-derived apparent unfolding enthalpies were more variable than apparent T m . Together, these findings show that DSF can be highly repeatable within a defined instrument and workflow, but that quantitative comparability across instruments depends on instrument-specific effects, the choice of fluorescence readout and analysis strategy. Improved comparability will require transparent reporting of acquisition and analysis conditions, explicit data-quality criteria, and well-characterised reference materials to monitor instrument-dependent offsets.
- Open Access
- 16 July 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-18
Rational correction of pathogenic conformational defects in HTRA1
Loss-of-function mutations in the homotrimeric serine protease HTRA1 cause cerebral vasculopathy. Here, we establish independent approaches to achieve the functional correction of trimer assembly defects. Focusing on the prototypical R274Q mutation, we identify an HTRA1 variant that promotes trimer formation thus restoring enzymatic activity in vitro. Genetic experiments in Htra1R274Q mice further demonstrate that expression of this protein-based corrector in trans is sufficient to stabilize HtrA1-R274Q and restore the proteomic signature of the brain vasculature. An alternative approach employs supramolecular chemical ligands that shift the monomer-trimer equilibrium towards proteolytically active trimers. Moreover, we identify a peptidic ligand that activates HTRA1 monomers. Our findings open perspectives for tailored protein repair strategies.
- 16 July 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-18
Open AccessRational correction of pathogenic conformational defects in HTRA1
Loss-of-function mutations in the homotrimeric serine protease HTRA1 cause cerebral vasculopathy. Here, we establish independent approaches to achieve the functional correction of trimer assembly defects. Focusing on the prototypical R274Q mutation, we identify an HTRA1 variant that promotes trimer formation thus restoring enzymatic activity in vitro. Genetic experiments in Htra1R274Q mice further demonstrate that expression of this protein-based corrector in trans is sufficient to stabilize HtrA1-R274Q and restore the proteomic signature of the brain vasculature. An alternative approach employs supramolecular chemical ligands that shift the monomer-trimer equilibrium towards proteolytically active trimers. Moreover, we identify a peptidic ligand that activates HTRA1 monomers. Our findings open perspectives for tailored protein repair strategies.
- Open Access
- 15 October 2021
- Published by Springer Nature in European Biophysics Journal
- Vol. 50 (8) , 1159-1160
Correction to: Reproducibility and accuracy of microscale thermophoresis in the NanoTemper Monolith: a multi laboratory benchmark study
- 15 October 2021
- Published by Springer Nature in European Biophysics Journal
- Vol. 50 (8) , 1159-1160
Open AccessCorrection to: Reproducibility and accuracy of microscale thermophoresis in the NanoTemper Monolith: a multi laboratory benchmark study
- Open Access
- 14 May 2021
- Published by Springer Nature in Nature Communications
- Vol. 12 (1) , 1-4
Quality control of protein reagents for the improvement of research data reproducibility
- 14 May 2021
- Published by Springer Nature in Nature Communications
- Vol. 12 (1) , 1-4
Open AccessQuality control of protein reagents for the improvement of research data reproducibility
- Open Access
- 21 April 2021
- Published by Springer Nature in European Biophysics Journal
- Vol. 50 (3-4) , 411-427
Reproducibility and accuracy of microscale thermophoresis in the NanoTemper Monolith: a multi laboratory benchmark study
Microscale thermophoresis (MST), and the closely related Temperature Related Intensity Change (TRIC), are synonyms for a recently developed measurement technique in the field of biophysics to quantify biomolecular interactions, using the (capillary-based) NanoTemper Monolith and (multiwell plate-based) Dianthus instruments. Although this technique has been extensively used within the scientific community due to its low sample consumption, ease of use, and ubiquitous applicability, MST/TRIC has not enjoyed the unambiguous acceptance from biophysicists afforded to other biophysical techniques like isothermal titration calorimetry (ITC) or surface plasmon resonance (SPR). This might be attributed to several facts, e.g., that various (not fully understood) effects are contributing to the signal, that the technique is licensed to only a single instrument developer, NanoTemper Technology, and that its reliability and reproducibility have never been tested independently and systematically. Thus, a working group of ARBRE-MOBIEU has set up a benchmark study on MST/TRIC to assess this technique as a method to characterize biomolecular interactions. Here we present the results of this study involving 32 scientific groups within Europe and two groups from the US, carrying out experiments on 40 Monolith instruments, employing a standard operation procedure and centrally prepared samples. A protein–small molecule interaction, a newly developed protein–protein interaction system and a pure dye were used as test systems. We characterized the instrument properties and evaluated instrument performance, reproducibility, the effect of different analysis tools, the influence of the experimenter during data analysis, and thus the overall reliability of this method.
- 21 April 2021
- Published by Springer Nature in European Biophysics Journal
- Vol. 50 (3-4) , 411-427
Open AccessReproducibility and accuracy of microscale thermophoresis in the NanoTemper Monolith: a multi laboratory benchmark study
Microscale thermophoresis (MST), and the closely related Temperature Related Intensity Change (TRIC), are synonyms for a recently developed measurement technique in the field of biophysics to quantify biomolecular interactions, using the (capillary-based) NanoTemper Monolith and (multiwell plate-based) Dianthus instruments. Although this technique has been extensively used within the scientific community due to its low sample consumption, ease of use, and ubiquitous applicability, MST/TRIC has not enjoyed the unambiguous acceptance from biophysicists afforded to other biophysical techniques like isothermal titration calorimetry (ITC) or surface plasmon resonance (SPR). This might be attributed to several facts, e.g., that various (not fully understood) effects are contributing to the signal, that the technique is licensed to only a single instrument developer, NanoTemper Technology, and that its reliability and reproducibility have never been tested independently and systematically. Thus, a working group of ARBRE-MOBIEU has set up a benchmark study on MST/TRIC to assess this technique as a method to characterize biomolecular interactions. Here we present the results of this study involving 32 scientific groups within Europe and two groups from the US, carrying out experiments on 40 Monolith instruments, employing a standard operation procedure and centrally prepared samples. A protein–small molecule interaction, a newly developed protein–protein interaction system and a pure dye were used as test systems. We characterized the instrument properties and evaluated instrument performance, reproducibility, the effect of different analysis tools, the influence of the experimenter during data analysis, and thus the overall reliability of this method.
- 17 April 2021
- Published by Springer Nature in European Biophysics Journal
- Vol. 50 (3-4) , 653-660
Microscale Thermophoresis and additional effects measured in NanoTemper Monolith instruments
NanoTemper Monolith instruments have gained enormous popularity for measuring molecular interactions both in academia and industry. The underlying technology has been extensively reviewed along with its assumptions, limitations, and applications (Scheuermann et al., Anal Biochem 496:79–93, 2016). Several assumptions about the technique such as the extent of thermal deviations generated by the infrared laser and the thermophoretic foundation of the measured signal have been revised during the last decade. We present here in this letter the experience gathered in scientific service facilities about this technique and make scientists aware of possible pitfalls with the intention to promote knowledge and good practice throughout the scientific community.
- 17 April 2021
- Published by Springer Nature in European Biophysics Journal
- Vol. 50 (3-4) , 653-660
Microscale Thermophoresis and additional effects measured in NanoTemper Monolith instruments
NanoTemper Monolith instruments have gained enormous popularity for measuring molecular interactions both in academia and industry. The underlying technology has been extensively reviewed along with its assumptions, limitations, and applications (Scheuermann et al., Anal Biochem 496:79–93, 2016). Several assumptions about the technique such as the extent of thermal deviations generated by the infrared laser and the thermophoretic foundation of the measured signal have been revised during the last decade. We present here in this letter the experience gathered in scientific service facilities about this technique and make scientists aware of possible pitfalls with the intention to promote knowledge and good practice throughout the scientific community.