Jun Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jun Zhao has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Renzhong Tai
Shanghai Advanced Research Institute, Chinese Academy of Sciences, 239 Zhangheng Road, Pudong District, Shanghai 201800, People's Republic of China
3 shared publications - Xujie Tong
Nanolithography and Application Research Group, School of Information Science and Technology, Fudan University, Shanghai 200433, People's Republic of China
3 shared publications - Yifang Chen
Fudan University
3 shared publications - Zijian Xu
Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800, China
3 shared publications - Chengwen Mao
Shanghai Synchrotron Radiation Facility, Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201210, People's Republic of China
2 shared publications - Chengyang Mu
Nanolithography and Application Research Group, School of Information Science and Technology, Fudan University, Shanghai 200433, People's Republic of China
2 shared publications
Latest Publications
- Open Access
- 28 October 2024
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 31 (6) , 1457-1463
A study of structural effects on the focusing and imaging performance of hard X-rays with 20–30 nm zone plates
Hard X-ray microscopes with 20–30 nm spatial resolution ranges are an advanced tool for the inspection of materials at the nanoscale. However, the limited efficiency of the focusing optics, for example, a Fresnel zone plate (ZP) lens, can significantly reduce the power of a nanoprobe. Despite several reports on ZP lenses that focus hard X-rays with 20 nm resolution – mainly constructed by zone-doubling techniques – a systematic investigation into the limiting factors has not been reported. We report the structural effects on the focusing and imaging efficiency of 20–30 nm-resolution ZPs, employing a modified beam-propagation method. The zone width and the duty cycle (zone width/ring pitch) were optimized to achieve maximum efficiency, and a comparative analysis of the zone materials was conducted. The optimized zone structures were used in the fabrication of Pt-hydrogen silsesquioxane (HSQ) ZPs. The highest focusing efficiency of the Pt-HSQ-ZP with a resolution of 30 nm was 10% at 7 keV and >5% in the range 6–10 keV, whereas the highest efficiency of the Pt-HSQ-ZP with a resolution of 20 nm was realized at 7 keV with an efficiency of 7.6%. Optical characterization conducted at X-ray beamlines demonstrated significant enhancement of the focusing and imaging efficiency in a broader range of hard X-rays from 5 keV to 10 keV, demonstrating the potential application in hard X-ray focusing and imaging.
- 28 October 2024
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 31 (6) , 1457-1463
Open AccessA study of structural effects on the focusing and imaging performance of hard X-rays with 20–30 nm zone plates
Hard X-ray microscopes with 20–30 nm spatial resolution ranges are an advanced tool for the inspection of materials at the nanoscale. However, the limited efficiency of the focusing optics, for example, a Fresnel zone plate (ZP) lens, can significantly reduce the power of a nanoprobe. Despite several reports on ZP lenses that focus hard X-rays with 20 nm resolution – mainly constructed by zone-doubling techniques – a systematic investigation into the limiting factors has not been reported. We report the structural effects on the focusing and imaging efficiency of 20–30 nm-resolution ZPs, employing a modified beam-propagation method. The zone width and the duty cycle (zone width/ring pitch) were optimized to achieve maximum efficiency, and a comparative analysis of the zone materials was conducted. The optimized zone structures were used in the fabrication of Pt-hydrogen silsesquioxane (HSQ) ZPs. The highest focusing efficiency of the Pt-HSQ-ZP with a resolution of 30 nm was 10% at 7 keV and >5% in the range 6–10 keV, whereas the highest efficiency of the Pt-HSQ-ZP with a resolution of 20 nm was realized at 7 keV with an efficiency of 7.6%. Optical characterization conducted at X-ray beamlines demonstrated significant enhancement of the focusing and imaging efficiency in a broader range of hard X-rays from 5 keV to 10 keV, demonstrating the potential application in hard X-ray focusing and imaging.
- Open Access
- 17 February 2023
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 30 (2) , 319-326
High-efficiency focusing and imaging by dielectric kinoform zone plate lenses with soft X-rays
With fast advances in enhancing the focusing/imaging resolution of Fresnel zone plate lenses toward sub-10 nm, low diffraction efficiency in connection with their rectangular zone shape still remains a big issue in both soft and hard X-ray microscopy. In hard X-ray optics, encouraging progress has recently been reported in our earlier attempts of high focusing efficiency by 3D kinoform shaped metallic zone plates, formed by greyscale electron beam lithography. This paper addresses our efforts towards high focusing/imaging efficiency by developing a novel dielectric kinoform zone plate lens for soft X-rays. The effects of the zone materials and zone shapes on the focusing/imaging quality were first theoretically investigated by a modified thin-grating-approximation method, revealing superior efficiencies of dielectric kinoform zone plates over rectangular ones in metals. Optical characterizations of replicated dielectric kinoform zone plates by greyscale electron beam lithography demonstrate a focusing efficiency of 15.5% with a resolution of 110 nm in the water window of X-rays. Apart from high efficiency, the novel kinoform zone plate lenses developed in this work exhibit significant advantages over conventional zone plates, i.e. simplified process, low cost and no need for a beamstop.
- 17 February 2023
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 30 (2) , 319-326
Open AccessHigh-efficiency focusing and imaging by dielectric kinoform zone plate lenses with soft X-rays
With fast advances in enhancing the focusing/imaging resolution of Fresnel zone plate lenses toward sub-10 nm, low diffraction efficiency in connection with their rectangular zone shape still remains a big issue in both soft and hard X-ray microscopy. In hard X-ray optics, encouraging progress has recently been reported in our earlier attempts of high focusing efficiency by 3D kinoform shaped metallic zone plates, formed by greyscale electron beam lithography. This paper addresses our efforts towards high focusing/imaging efficiency by developing a novel dielectric kinoform zone plate lens for soft X-rays. The effects of the zone materials and zone shapes on the focusing/imaging quality were first theoretically investigated by a modified thin-grating-approximation method, revealing superior efficiencies of dielectric kinoform zone plates over rectangular ones in metals. Optical characterizations of replicated dielectric kinoform zone plates by greyscale electron beam lithography demonstrate a focusing efficiency of 15.5% with a resolution of 110 nm in the water window of X-rays. Apart from high efficiency, the novel kinoform zone plate lenses developed in this work exhibit significant advantages over conventional zone plates, i.e. simplified process, low cost and no need for a beamstop.
- Open Access
- 15 February 2022
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 29 (2) , 386-392
Trapezoid-kinoform zone plate lens – a solution for efficient focusing in hard X-ray optics
X-ray microscopes are powerful tools in the nano-inspection of materials owing to their ultra-high resolution at the molecular level. However, the focusing efficiency of binary zone plate lenses as key components in such probes is merely 5% in practice, hindering their application in advanced scientific research. Although kinoform zone plate lenses are in principle supposed to possess high efficiency beyond binary ones, little progress has been reported so far due to the shortage of both a theoretical calculation approach and greyscale lithography for generating fine three-dimensional (3D) kinoform zones of the lenses. This paper reports our theoretical work for a modified beam propagation method to compute the focusing performance and state-of-the-art 3D greyscale electron beam lithography for kinoform zone plate lenses. Three different zone shapes – binary, kinoform and top-flat kinoform (nicknamed the trapezoid-kinoform) – were compared both theoretically and experimentally. Theoretical calculations suggest, for the first time, that the trapezoid-kinoform zone plate gives rise to the highest focusing efficiency among the three lenses, which was proved by optical characterization of the fabricated lens with hard X-rays. As high as 40% of the focusing efficiency by Au trapezoid-kinoform lenses with resolution of 250 nm at 8 keV has been achieved, which is two times higher than that of binary zone plate lenses. The origin of the enhanced efficiency in the trapezoid-kinoform zone plate lens was explained by the joint contributions from both the refraction through the kinoform slope and the diffraction through the top flat part of the trapezoid-kinoform zone plate. Such a breakthrough in focusing efficiency sheds light on the further development of X-ray lenses with both high resolution and high efficiency.
- 15 February 2022
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 29 (2) , 386-392
Open AccessTrapezoid-kinoform zone plate lens – a solution for efficient focusing in hard X-ray optics
X-ray microscopes are powerful tools in the nano-inspection of materials owing to their ultra-high resolution at the molecular level. However, the focusing efficiency of binary zone plate lenses as key components in such probes is merely 5% in practice, hindering their application in advanced scientific research. Although kinoform zone plate lenses are in principle supposed to possess high efficiency beyond binary ones, little progress has been reported so far due to the shortage of both a theoretical calculation approach and greyscale lithography for generating fine three-dimensional (3D) kinoform zones of the lenses. This paper reports our theoretical work for a modified beam propagation method to compute the focusing performance and state-of-the-art 3D greyscale electron beam lithography for kinoform zone plate lenses. Three different zone shapes – binary, kinoform and top-flat kinoform (nicknamed the trapezoid-kinoform) – were compared both theoretically and experimentally. Theoretical calculations suggest, for the first time, that the trapezoid-kinoform zone plate gives rise to the highest focusing efficiency among the three lenses, which was proved by optical characterization of the fabricated lens with hard X-rays. As high as 40% of the focusing efficiency by Au trapezoid-kinoform lenses with resolution of 250 nm at 8 keV has been achieved, which is two times higher than that of binary zone plate lenses. The origin of the enhanced efficiency in the trapezoid-kinoform zone plate lens was explained by the joint contributions from both the refraction through the kinoform slope and the diffraction through the top flat part of the trapezoid-kinoform zone plate. Such a breakthrough in focusing efficiency sheds light on the further development of X-ray lenses with both high resolution and high efficiency.
- 14 April 2021
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 28 (3) , 902-909
Analysis of partially coherent light propagation through the soft X-ray interference lithography beamline at SSRF
The mutual optical intensity (MOI) model is extended to the simulation of the interference pattern produced by extreme ultraviolet lithography with partially coherent light. The partially coherent X-ray propagation through the BL08U1B beamline at Shanghai Synchrotron Radiation Facility is analysed using the MOI model and SRW (Synchrotron Radiation Workshop) method. The fringe intensity at the exposure area is not uniform but has similar envelope lines to Fresnel diffraction, which is explained by the diffraction from the finite grating modelled as a single aperture. By balancing the slit size and photon stop size, the fringe visibility, photon flux and intensity slope can be optimized. Further analysis shows that the effect of pink light on the aerial images is negligible, whereas the third-harmonic light should be considered to obtain a balance between high fringe visibility and high flux. Two grating interference exposure experiments were performed in the BL08U1B beamline. The aerial image depth showed that the polymethyl methacrylate photoresist depth was determined by the X-ray coherence properties.
- 14 April 2021
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 28 (3) , 902-909
Analysis of partially coherent light propagation through the soft X-ray interference lithography beamline at SSRF
The mutual optical intensity (MOI) model is extended to the simulation of the interference pattern produced by extreme ultraviolet lithography with partially coherent light. The partially coherent X-ray propagation through the BL08U1B beamline at Shanghai Synchrotron Radiation Facility is analysed using the MOI model and SRW (Synchrotron Radiation Workshop) method. The fringe intensity at the exposure area is not uniform but has similar envelope lines to Fresnel diffraction, which is explained by the diffraction from the finite grating modelled as a single aperture. By balancing the slit size and photon stop size, the fringe visibility, photon flux and intensity slope can be optimized. Further analysis shows that the effect of pink light on the aerial images is negligible, whereas the third-harmonic light should be considered to obtain a balance between high fringe visibility and high flux. Two grating interference exposure experiments were performed in the BL08U1B beamline. The aerial image depth showed that the polymethyl methacrylate photoresist depth was determined by the X-ray coherence properties.