Qiuping Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Qiuping Wang has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Xuewei Du
University of Science and Technology of China
6 shared publications - Zhanglang Xu
University of Science and Technology of China
4 shared publications - Jie Chen
University of Science and Technology of China, State Key Laboratory of Particle Detection and Electr
2 shared publications Jin Shen
National Synchrotron Radiation Laboratory, University of Science and Technology of China 4 , Hefei 230029, China
2 shared publications- Shuai Zhao
University of Science and Technology of China
2 shared publications - Shuaikang Jiang
National Synchrotron Radiation Laboratory, University of Science and Technology of China , Hefei 230029
2 shared publications
Latest Publications
- 1 February 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (2)
The design and analysis of high-precision x-ray mirror benders for Kirkpatrick–Baez mirror system in Hefei advanced light facility
Hefei Advanced Light Facility is a diffraction-limited synchrotron radiation light source in the soft x-ray range. The BL04 beamline needs micro-focusing spots for spatial and time-resolving experiments, and the Kirkpatrick–Baez mirror system is adopted as a post-focusing system. In this paper, a high-precision mirror bender with flexure mechanism modules has been designed to dynamically bend the flat mirror to an elliptical form. Given the required high surface accuracy, the mirror bender is optimized with the variable mirror profile. The bending moments can be applied independently on the bender ends, so the mirror can be bent to a different elliptical form, meeting the needs of focusing on different experimental stations. Based on the optomechanical design, the mirror bender can bend a 500 mm long flat mirror to an elliptical form with a small radius of curvature (∼400 m). When focused on the photo emission electron microscopy station, the residual slope error of the bent mirror surface is optimized to 7.2 nrad (rms). This work introduces the bender’s optomechanical design and simulation process for verification. In addition, the machining and assembly errors’ influence on the bending surface is evaluated and the influence of mirror substrate manufacturing errors on surface accuracy is systematically discussed. The tolerance requirements for mirror manufacturing are specified based on the analysis results. The optomechanical design and optimization for the bender provide a reference for subsequent engineering design.
- 1 February 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (2)
The design and analysis of high-precision x-ray mirror benders for Kirkpatrick–Baez mirror system in Hefei advanced light facility
Hefei Advanced Light Facility is a diffraction-limited synchrotron radiation light source in the soft x-ray range. The BL04 beamline needs micro-focusing spots for spatial and time-resolving experiments, and the Kirkpatrick–Baez mirror system is adopted as a post-focusing system. In this paper, a high-precision mirror bender with flexure mechanism modules has been designed to dynamically bend the flat mirror to an elliptical form. Given the required high surface accuracy, the mirror bender is optimized with the variable mirror profile. The bending moments can be applied independently on the bender ends, so the mirror can be bent to a different elliptical form, meeting the needs of focusing on different experimental stations. Based on the optomechanical design, the mirror bender can bend a 500 mm long flat mirror to an elliptical form with a small radius of curvature (∼400 m). When focused on the photo emission electron microscopy station, the residual slope error of the bent mirror surface is optimized to 7.2 nrad (rms). This work introduces the bender’s optomechanical design and simulation process for verification. In addition, the machining and assembly errors’ influence on the bending surface is evaluated and the influence of mirror substrate manufacturing errors on surface accuracy is systematically discussed. The tolerance requirements for mirror manufacturing are specified based on the analysis results. The optomechanical design and optimization for the bender provide a reference for subsequent engineering design.
- 1 December 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (12)
LTP-corrected stitching interferometer achieving sub-nanometer accuracy for x-ray mirror metrology
This paper presents a sub-nanometer accuracy stitching interferometry system for metrology of large curved x-ray mirrors, incorporating Long Trace Profiler (LTP) low-frequency correction. Utilizing a Fizeau interferometer with a reference transmission flat to measure sub-apertures of flat or curved optics, the system employs a mixed stitching method to achieve high-precision metrology of large x-ray mirrors. Crucially, the instrument overcomes cumulative angular errors in sub-aperture stitching through LTP-guided correction, achieving 0.18 nm RMS measurement repeatability validated on high-precision optics. After calibration of the transmission reference flat and zoom factor, the system demonstrates exceptional consistency with direct LTP measurements (<0.2 nm RMS), surpassing software-only techniques, while successfully verifying curved-mirror capability via <1% radius error measurement on spherical mirror with a radius of curvature of 24.6 m. For challenging elliptical synchrotron x-ray mirrors, our measurements of a specimen with 50 nrad RMS slope error and 0.5 nm RMS height error demonstrate excellent agreement with both manufacturer’s RADSI and LTP reference data. By eliminating angular drift propagation during the stitching process, this metrology system achieves sub-nanometer measurement accuracy for strongly curved x-ray optics.
- 1 December 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (12)
LTP-corrected stitching interferometer achieving sub-nanometer accuracy for x-ray mirror metrology
This paper presents a sub-nanometer accuracy stitching interferometry system for metrology of large curved x-ray mirrors, incorporating Long Trace Profiler (LTP) low-frequency correction. Utilizing a Fizeau interferometer with a reference transmission flat to measure sub-apertures of flat or curved optics, the system employs a mixed stitching method to achieve high-precision metrology of large x-ray mirrors. Crucially, the instrument overcomes cumulative angular errors in sub-aperture stitching through LTP-guided correction, achieving 0.18 nm RMS measurement repeatability validated on high-precision optics. After calibration of the transmission reference flat and zoom factor, the system demonstrates exceptional consistency with direct LTP measurements (<0.2 nm RMS), surpassing software-only techniques, while successfully verifying curved-mirror capability via <1% radius error measurement on spherical mirror with a radius of curvature of 24.6 m. For challenging elliptical synchrotron x-ray mirrors, our measurements of a specimen with 50 nrad RMS slope error and 0.5 nm RMS height error demonstrate excellent agreement with both manufacturer’s RADSI and LTP reference data. By eliminating angular drift propagation during the stitching process, this metrology system achieves sub-nanometer measurement accuracy for strongly curved x-ray optics.
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Thermal optimization of a high heat load liquid-metal-bath cooled mirror at the Hefei Advanced Light Facility
Within the beamlines of diffraction-limited storage rings, the liquid-metal-bath cooling scheme is a prevalent choice for the cooling of high-heat load mirrors. This study employs the finite element analysis method to evaluate the thermal deformations of liquid-metal-bath horizontally deflecting mirrors in the Hefei Advanced Light Facility. In particular, we introduce a novel optimization strategy to obtain the optimal thermal deformation scenario, which also satisfies mechanical design requirements. Moreover, a concurrent optimization approach across multiple structural parameters of mirrors is adopted to attain globally optimal thermal deformation. Following the optimization of the mirror’s structural parameters, the curvature radius increases to 227 km, while the residual slope error decreases to 36.3 nrad at 6 eV in the meridian direction. The ray tracing analysis of the beam demonstrates a considerable reduction in the influence of thermal deformation on the beam’s focal point. This work proposes an optimization method for designing cooling schemes under mechanical constraints.
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Thermal optimization of a high heat load liquid-metal-bath cooled mirror at the Hefei Advanced Light Facility
Within the beamlines of diffraction-limited storage rings, the liquid-metal-bath cooling scheme is a prevalent choice for the cooling of high-heat load mirrors. This study employs the finite element analysis method to evaluate the thermal deformations of liquid-metal-bath horizontally deflecting mirrors in the Hefei Advanced Light Facility. In particular, we introduce a novel optimization strategy to obtain the optimal thermal deformation scenario, which also satisfies mechanical design requirements. Moreover, a concurrent optimization approach across multiple structural parameters of mirrors is adopted to attain globally optimal thermal deformation. Following the optimization of the mirror’s structural parameters, the curvature radius increases to 227 km, while the residual slope error decreases to 36.3 nrad at 6 eV in the meridian direction. The ray tracing analysis of the beam demonstrates a considerable reduction in the influence of thermal deformation on the beam’s focal point. This work proposes an optimization method for designing cooling schemes under mechanical constraints.
- 1 April 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (4) , 043544
Design consideration of an x-ray imaging crystal spectrometer for China Fusion Engineering Test Reactor
The x-ray imaging crystal spectrometer (XICS) is proposed as the principal method of diagnostics for plasma ion temperature and rotation for the China Fusion Engineering Test Reactor (CFETR) for its simplicity in implementation and no reliance on neutral beams. For D–T experiments with the electron temperature as high as 35–40 keV at the core region, highly charged high-Z ions can serve as the diagnostic ions for the XICS. For the CFETR, Xe44+, Xe51+, and W64+ are selected as the impurity ions. Appropriate crystal parameters are selected, as well as the preliminary layout for the spectrometer. We estimated the general performance of the spectrometer, including the emissivity of the impurities, the spatial resolution of the x-ray detector, and the expected count rate of line emissions. For the application in the fusion reactor environment, the effect of neutron irradiation on the crystal is briefly discussed.
- 1 April 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (4) , 043544
Design consideration of an x-ray imaging crystal spectrometer for China Fusion Engineering Test Reactor
The x-ray imaging crystal spectrometer (XICS) is proposed as the principal method of diagnostics for plasma ion temperature and rotation for the China Fusion Engineering Test Reactor (CFETR) for its simplicity in implementation and no reliance on neutral beams. For D–T experiments with the electron temperature as high as 35–40 keV at the core region, highly charged high-Z ions can serve as the diagnostic ions for the XICS. For the CFETR, Xe44+, Xe51+, and W64+ are selected as the impurity ions. Appropriate crystal parameters are selected, as well as the preliminary layout for the spectrometer. We estimated the general performance of the spectrometer, including the emissivity of the impurities, the spatial resolution of the x-ray detector, and the expected count rate of line emissions. For the application in the fusion reactor environment, the effect of neutron irradiation on the crystal is briefly discussed.
- 20 December 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11209, 1120906-8
Accurate x-ray source dimension measurement by the spherically bent crystal imaging system
X-ray sources are widely used in non-destructive testing applications. The focal spot shape and size of an X-ray source are important factors that influence the resolution and contrast of images. A monochromatic imaging method using a spherically bent crystal is proposed to measure the focal spot size of X-ray sources. The natural emission spectral lines of the target material are imaged to distinguish the target from the substrate. Thus, the fine structures of the focal spot can be measured combined with high spatial resolution. With a backlight imaging experiment, the imaging system achieves a high spatial resolution of ~10 μm over a large field of view of 2.5 mm with a narrow energy band of 2 eV at 8.05 keV. The X-ray focal spot size of a laboratory X-ray source with a Cu anode is measured using the spherically bent crystal imaging system and a pinhole camera respectively. The spherically bent crystal imaging system provides high spatial resolution and additional details for the focal spot. Thus, the monochromatic imaging method is applicable for the accurate X-ray source dimension measurement.
- 20 December 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11209, 1120906-8
Accurate x-ray source dimension measurement by the spherically bent crystal imaging system
X-ray sources are widely used in non-destructive testing applications. The focal spot shape and size of an X-ray source are important factors that influence the resolution and contrast of images. A monochromatic imaging method using a spherically bent crystal is proposed to measure the focal spot size of X-ray sources. The natural emission spectral lines of the target material are imaged to distinguish the target from the substrate. Thus, the fine structures of the focal spot can be measured combined with high spatial resolution. With a backlight imaging experiment, the imaging system achieves a high spatial resolution of ~10 μm over a large field of view of 2.5 mm with a narrow energy band of 2 eV at 8.05 keV. The X-ray focal spot size of a laboratory X-ray source with a Cu anode is measured using the spherically bent crystal imaging system and a pinhole camera respectively. The spherically bent crystal imaging system provides high spatial resolution and additional details for the focal spot. Thus, the monochromatic imaging method is applicable for the accurate X-ray source dimension measurement.
- 1 August 2005
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 548 (3) , 574-581
Commissioning of a new beamline and station for ARPES at NSRL
- 1 August 2005
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 548 (3) , 574-581
Commissioning of a new beamline and station for ARPES at NSRL