LTP-corrected stitching interferometer achieving sub-nanometer accuracy for x-ray mirror metrology
- 1 December 2025
- journal article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (12)
Abstract
This paper presents a sub-nanometer accuracy stitching interferometry system for metrology of large curved x-ray mirrors, incorporating Long Trace Profiler (LTP) low-frequency correction. Utilizing a Fizeau interferometer with a reference transmission flat to measure sub-apertures of flat or curved optics, the system employs a mixed stitching method to achieve high-precision metrology of large x-ray mirrors. Crucially, the instrument overcomes cumulative angular errors in sub-aperture stitching through LTP-guided correction, achieving 0.18 nm RMS measurement repeatability validated on high-precision optics. After calibration of the transmission reference flat and zoom factor, the system demonstrates exceptional consistency with direct LTP measurements (<0.2 nm RMS), surpassing software-only techniques, while successfully verifying curved-mirror capability via <1% radius error measurement on spherical mirror with a radius of curvature of 24.6 m. For challenging elliptical synchrotron x-ray mirrors, our measurements of a specimen with 50 nrad RMS slope error and 0.5 nm RMS height error demonstrate excellent agreement with both manufacturer’s RADSI and LTP reference data. By eliminating angular drift propagation during the stitching process, this metrology system achieves sub-nanometer measurement accuracy for strongly curved x-ray optics.Keywords
Funding Information
- National Key Research and Development Program of China (2023YFA1608602)
- China Postdoctoral Science Foundation (2024M753120)
- Fundamental Research Funds for the Central Universities (WK2310000126)
This publication has 18 references indexed in Scilit:
- A Fizeau interferometry stitching system to characterize X-ray mirrors with sub-nanometre errorsOptics and Lasers in Engineering, 2022
- Stitching interferometry for synchrotron mirror metrology at National Synchrotron Light Source II (NSLS-II)Optics and Lasers in Engineering, 2020
- Stitching techniques for measuring X-ray synchrotron mirror topographyReview of Scientific Instruments, 2019
- Surface shape determination with a stitching Michelson interferometer and accuracy evaluationReview of Scientific Instruments, 2019
- On the characterization of ultra-precise X-ray optical components: advances and challenges inex situmetrologyJournal of Synchrotron Radiation, 2014
- Stitching interferometric metrology for steeply curved x‐ray mirrorsSurface and Interface Analysis, 2008
- Relative angle determinable stitching interferometry for hard x-ray reflective opticsReview of Scientific Instruments, 2005
- The Nanometer Optical Component Measuring Machine: a new Sub-nm Topography Measuring Device for X-ray Optics at BESSYAIP Conference Proceedings, 2004
- The penta-prism LTP: A long-trace-profiler with stationary optical head and moving penta prisma)Review of Scientific Instruments, 1995
- Using a straightness reference in obtaining more accurate surface profiles from a long trace profilerReview of Scientific Instruments, 1992