Dan-Marius Mustață
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dan-Marius Mustață has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Ioana Ionel
Faculty of Mechanical Engineering, Politehnica University of Timisoara, 300006 Timisoara, Romania
7 shared publications - Ramon-Mihai Balogh
Faculty of Mechanical Engineering, Universitatea Politehnica Timisoara, 300006 Timisoara, Romania
4 shared publications - Rareș-Mihăiță Popa
Faculty of Mechanical Engineering, Universitatea Politehnica Timisoara, 300006 Timisoara, Romania
4 shared publications - Daniel Bisorca
Faculty of Civil Engineering, Universitatea Politehnica Timisoara, 300006 Timisoara, Romania
3 shared publications - Ciprian Dughir
Faculty of Electronics, Telecommunications and Information Technologies, Politehnica University Timisoara, 300223 Timișoara, Romania
2 shared publications - Daniel Bisorca
Faculty of Mechanical Engineering, Universitatea Politehnica Timisoara, 300006 Timisoara, Romania
2 shared publications
Latest Publications
- Open Access
- 4 February 2026
- Published by MDPI AG in Chemosensors
- Vol. 14 (2) , 44
Low-Cost Particulate Matter and Gas Sensor Systems for Roadside Environmental Monitoring: Mechanistic and Predictive Insights from One-Year Urban Measurements
Roadside public transport stops represent localized air pollution hotspots where short-term exposure may differ substantially from levels reported by urban background monitoring. This study investigates the application of low-cost air quality sensors for long-term characterization of particulate matter and gaseous pollutants in a traffic-dominated urban microenvironment. The novelty of this work lies in the combined use of collocated low-cost sensors, energy-independent solar-powered deployment, height-resolved placement representative of different breathing zones, and integrated statistical and predictive analysis to resolve exposure-relevant pollutant dynamics at a single transport stop. Hourly concentrations of particulate matter (PM) PM1, PM2.5, PM10, nitrogen dioxide (NO2), and ozone (O3) were measured over one year at a roadside transport stop adjacent to a four-lane urban road carrying approximately 30,000 vehicles per day. Measurements were obtained using two collocated low-cost sensor units based on optical particle sensing for particulate matter and electrochemical sensing for gases, together with concurrent meteorological observations. Strong agreement between the two particulate matter sensors supported the use of averaged concentrations. Mean PM2.5 concentrations were substantially higher in winter (32.4 µg/m3) than in summer (10.4 µg/m3), indicating pronounced seasonal variability. PM1 and PM2.5 exhibited closely aligned temporal patterns, while PM10 showed greater variability. NO2 displayed sharp diurnal peaks associated with traffic activity, whereas O3 exhibited opposing seasonal and diurnal behavior and was negatively correlated with both PM2.5 (r = −0.32) and NO2 (r = −0.29). One-hour-ahead predictive models incorporating meteorological and temporal variables achieved coefficients of determination up to 0.84. The results demonstrate that energy-independent low-cost sensor systems can robustly capture temporal patterns, pollutant interactions, and short-term predictability in localized roadside environments relevant to exposure assessment.
- 4 February 2026
- Published by MDPI AG in Chemosensors
- Vol. 14 (2) , 44
Open AccessLow-Cost Particulate Matter and Gas Sensor Systems for Roadside Environmental Monitoring: Mechanistic and Predictive Insights from One-Year Urban Measurements
Roadside public transport stops represent localized air pollution hotspots where short-term exposure may differ substantially from levels reported by urban background monitoring. This study investigates the application of low-cost air quality sensors for long-term characterization of particulate matter and gaseous pollutants in a traffic-dominated urban microenvironment. The novelty of this work lies in the combined use of collocated low-cost sensors, energy-independent solar-powered deployment, height-resolved placement representative of different breathing zones, and integrated statistical and predictive analysis to resolve exposure-relevant pollutant dynamics at a single transport stop. Hourly concentrations of particulate matter (PM) PM1, PM2.5, PM10, nitrogen dioxide (NO2), and ozone (O3) were measured over one year at a roadside transport stop adjacent to a four-lane urban road carrying approximately 30,000 vehicles per day. Measurements were obtained using two collocated low-cost sensor units based on optical particle sensing for particulate matter and electrochemical sensing for gases, together with concurrent meteorological observations. Strong agreement between the two particulate matter sensors supported the use of averaged concentrations. Mean PM2.5 concentrations were substantially higher in winter (32.4 µg/m3) than in summer (10.4 µg/m3), indicating pronounced seasonal variability. PM1 and PM2.5 exhibited closely aligned temporal patterns, while PM10 showed greater variability. NO2 displayed sharp diurnal peaks associated with traffic activity, whereas O3 exhibited opposing seasonal and diurnal behavior and was negatively correlated with both PM2.5 (r = −0.32) and NO2 (r = −0.29). One-hour-ahead predictive models incorporating meteorological and temporal variables achieved coefficients of determination up to 0.84. The results demonstrate that energy-independent low-cost sensor systems can robustly capture temporal patterns, pollutant interactions, and short-term predictability in localized roadside environments relevant to exposure assessment.
- Open Access
- 16 August 2025
- Published by MDPI AG in Atmosphere
- Vol. 16 (8) , 972
Real-Time Insights into Indoor Air Quality in University Environments: PM and CO2 Monitoring
This study presents real-time measurements of particulate matter (PM1, PM2.5, PM10) and carbon dioxide (CO2) concentrations across five university indoor environments with varying occupancy levels and natural ventilation conditions. CO2 concentrations frequently exceeded the 1000 ppm guideline, with peak values reaching 3018 ppm and 2715 ppm in lecture spaces, whereas one workshop environment maintained levels well below limits (mean = 668 ppm). PM concentrations varied widely: PM10 reached 541.5 µg/m3 in a carpeted amphitheater, significantly surpassing the 50 µg/m3 legal daily limit, while a well-ventilated classroom exhibited lower levels despite moderate occupancy (PM10 max = 116.9 µg/m3). Elevated PM values were strongly associated with flooring type and occupant movement, not just activity type. Notably, window ventilation during breaks reduced CO2 concentrations by up to 305 ppm (p < 1 × 10−47) and PM10 by over 20% in rooms with favorable layouts. These findings highlight the importance of ventilation strategy, spatial orientation, and surface materials in shaping indoor air quality. The study emphasizes the need for targeted, non-invasive interventions to reduce pollutant exposure in historic university buildings where mechanical ventilation upgrades are often restricted.
- 16 August 2025
- Published by MDPI AG in Atmosphere
- Vol. 16 (8) , 972
Open AccessReal-Time Insights into Indoor Air Quality in University Environments: PM and CO2 Monitoring
This study presents real-time measurements of particulate matter (PM1, PM2.5, PM10) and carbon dioxide (CO2) concentrations across five university indoor environments with varying occupancy levels and natural ventilation conditions. CO2 concentrations frequently exceeded the 1000 ppm guideline, with peak values reaching 3018 ppm and 2715 ppm in lecture spaces, whereas one workshop environment maintained levels well below limits (mean = 668 ppm). PM concentrations varied widely: PM10 reached 541.5 µg/m3 in a carpeted amphitheater, significantly surpassing the 50 µg/m3 legal daily limit, while a well-ventilated classroom exhibited lower levels despite moderate occupancy (PM10 max = 116.9 µg/m3). Elevated PM values were strongly associated with flooring type and occupant movement, not just activity type. Notably, window ventilation during breaks reduced CO2 concentrations by up to 305 ppm (p < 1 × 10−47) and PM10 by over 20% in rooms with favorable layouts. These findings highlight the importance of ventilation strategy, spatial orientation, and surface materials in shaping indoor air quality. The study emphasizes the need for targeted, non-invasive interventions to reduce pollutant exposure in historic university buildings where mechanical ventilation upgrades are often restricted.
- 21 November 2024
- Published by Springer Nature
- p. 161-169
Roof up or Down: Exploring Particulate Matter and Noise Pollution Dynamics in Convertible Vehicles
- 21 November 2024
- Published by Springer Nature
- p. 161-169
Roof up or Down: Exploring Particulate Matter and Noise Pollution Dynamics in Convertible Vehicles
- Open Access
- 25 October 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (21) , 11649
Metal Element Traces Sampled from Peri-Urban Road Verge Particulate Matter
The objective of this research is to analyze metal elements, such as Na (sodium), Mg (magnesium), Al (aluminum), Si (silicon), Pb (lead), K (potassium), Ca (calcium), and Fe (iron), found in dust particles within two distinct areas from which the samplings were taken. The first sampling was taken from the road verge of a highly trafficked road section, while the second sampling was taken from a residential garden area 90 m away from the road. Several metal elements were detected with a high difference in Si, which presented higher concentrations in the dust samples from the road verge area. Pb has only been detected in the samples taken from the road verge, which could be explained by residual remnants from old lead gasoline and wheel weights. Additionally, during the same investigation, airborne particulate matter (PM) concentrations were measured in comparison between the road verge and the garden area; this presented a substantial difference in the concentration levels, suggesting that dense vegetation is protecting and blocking a majority of airborne PM. A literature highlight of the health effects of different metal elements and PM concentrations is presented.
- 25 October 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (21) , 11649
Open AccessMetal Element Traces Sampled from Peri-Urban Road Verge Particulate Matter
The objective of this research is to analyze metal elements, such as Na (sodium), Mg (magnesium), Al (aluminum), Si (silicon), Pb (lead), K (potassium), Ca (calcium), and Fe (iron), found in dust particles within two distinct areas from which the samplings were taken. The first sampling was taken from the road verge of a highly trafficked road section, while the second sampling was taken from a residential garden area 90 m away from the road. Several metal elements were detected with a high difference in Si, which presented higher concentrations in the dust samples from the road verge area. Pb has only been detected in the samples taken from the road verge, which could be explained by residual remnants from old lead gasoline and wheel weights. Additionally, during the same investigation, airborne particulate matter (PM) concentrations were measured in comparison between the road verge and the garden area; this presented a substantial difference in the concentration levels, suggesting that dense vegetation is protecting and blocking a majority of airborne PM. A literature highlight of the health effects of different metal elements and PM concentrations is presented.
- Open Access
- 5 September 2023
- Published by MDPI AG in Preprints.org
Metal Element Traces Sampled from Peri-Urban Road Verge Particulate Matter
The objective of this research is to analyze metal elements like Na (sodium), Mg (magnesium), Al (aluminum), Si (silicon), Pb (lead), K (potassium), Ca (calcium), and Fe (iron) found in dust particles within two distinct areas from which the sampling has been done. First sampling was taken from the road verge of a highly trafficked road section, while the second sampling was done in a residential garden area 90 m away from the road. Several metal elements have been detected, with a high difference for Silicon Si, which present higher concentrations in the dust sampled from the road verge area. Pb has only been detected in the samples taken from the road verge, which could be explained by residual remnants from old lead gasoline, and wheel weights. Additionally, airborne particulate matter (PM) concentrations have been measured, during the same episode, in comparison between the road verge and the garden area, presenting a substantial difference in the concentration levels, deducing that dense vegetation is protecting and blocking a majority of airborne PM. A literature highlight of health effects of different metal elements and PM concentrations is presented.
- 5 September 2023
- Published by MDPI AG in Preprints.org
Open AccessMetal Element Traces Sampled from Peri-Urban Road Verge Particulate Matter
The objective of this research is to analyze metal elements like Na (sodium), Mg (magnesium), Al (aluminum), Si (silicon), Pb (lead), K (potassium), Ca (calcium), and Fe (iron) found in dust particles within two distinct areas from which the sampling has been done. First sampling was taken from the road verge of a highly trafficked road section, while the second sampling was done in a residential garden area 90 m away from the road. Several metal elements have been detected, with a high difference for Silicon Si, which present higher concentrations in the dust sampled from the road verge area. Pb has only been detected in the samples taken from the road verge, which could be explained by residual remnants from old lead gasoline, and wheel weights. Additionally, airborne particulate matter (PM) concentrations have been measured, during the same episode, in comparison between the road verge and the garden area, presenting a substantial difference in the concentration levels, deducing that dense vegetation is protecting and blocking a majority of airborne PM. A literature highlight of health effects of different metal elements and PM concentrations is presented.
- Open Access
- 31 July 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (15) , 8824
A Study on Particulate Matter from an Area with High Traffic Intensity
This research focuses on analyzing concentrations of particulate matter (PM) next to a highly congested road section, with 39,900 as the maximum number of vehicles per 24 h, in the vicinity of Timisoara, Romania. The concentrations are measured in multiple episodes using two different measurement methods, gravimetric and dynamic light scattering, showing a dispersion range of the PM concentrations. The presence of metal particles in the samples are analyzed using an electron microscope. Additionally, the impact on human health is described by evaluating the results for inhalable-, thoracic-, and alveolar-sized particles.
- 31 July 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (15) , 8824
Open AccessA Study on Particulate Matter from an Area with High Traffic Intensity
This research focuses on analyzing concentrations of particulate matter (PM) next to a highly congested road section, with 39,900 as the maximum number of vehicles per 24 h, in the vicinity of Timisoara, Romania. The concentrations are measured in multiple episodes using two different measurement methods, gravimetric and dynamic light scattering, showing a dispersion range of the PM concentrations. The presence of metal particles in the samples are analyzed using an electron microscope. Additionally, the impact on human health is described by evaluating the results for inhalable-, thoracic-, and alveolar-sized particles.
- Open Access
- 30 June 2023
- Published by MDPI AG in Preprints.org
A Study on Particulate Matter From an Area With High Traffic Intensity
The research is focusing on analyzing the concentrations of particulate matter (PM) next to a highly congested road section, with 39,900 as a maximum number of vehicles per 24 h, in the vicinity of Timisoara, Romania. Concentrations have been measured in multiple episodes using two different measurement methods, gravimetric and dynamic light scattering, showing a disperse range of PM concentrations. Presence of metal particles in the samples have been analyzed using an electron microscope. Additionally, impact on human health is described by evaluating results for inhalable, thoracic, and alveolar sized particles.
- 30 June 2023
- Published by MDPI AG in Preprints.org
Open AccessA Study on Particulate Matter From an Area With High Traffic Intensity
The research is focusing on analyzing the concentrations of particulate matter (PM) next to a highly congested road section, with 39,900 as a maximum number of vehicles per 24 h, in the vicinity of Timisoara, Romania. Concentrations have been measured in multiple episodes using two different measurement methods, gravimetric and dynamic light scattering, showing a disperse range of PM concentrations. Presence of metal particles in the samples have been analyzed using an electron microscope. Additionally, impact on human health is described by evaluating results for inhalable, thoracic, and alveolar sized particles.
- 24 March 2021
- Published by Editura Thoth in Journal of Research and Innovation for Sustainable Society
- Vol. 3 (1)
Air quality sensors in public transport stops and cross-system communication
The purpose of this article is to present a state of art implementation of air quality sensors in public transport stops. Effects on health due to different types of pollutants are summarized as well. Functional scope of the solutions, via warning messages displayed for passengers waiting at these stops, including a cross system communication between traffic management and public transport systems, are also focused. Analysis of existing sensor types from multiple view point including functions, types of measured pollutants, price ranges and comparisons are outlined.
- 24 March 2021
- Published by Editura Thoth in Journal of Research and Innovation for Sustainable Society
- Vol. 3 (1)
Air quality sensors in public transport stops and cross-system communication
The purpose of this article is to present a state of art implementation of air quality sensors in public transport stops. Effects on health due to different types of pollutants are summarized as well. Functional scope of the solutions, via warning messages displayed for passengers waiting at these stops, including a cross system communication between traffic management and public transport systems, are also focused. Analysis of existing sensor types from multiple view point including functions, types of measured pollutants, price ranges and comparisons are outlined.