Daniel Bisorca
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Daniel Bisorca has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Ioana Ionel
Faculty of Mechanical Engineering, Politehnica University of Timisoara, 300006 Timisoara, Romania
5 shared publications - Adriana Tokar
Faculty of Civil Engineering, University Politehnica Timisoara, 300223 Timișoara, Romania
3 shared publications - Dan-Marius Mustață
Faculty of Mechanical Engineering, Universitatea Politehnica Timisoara, 300006 Timisoara, Romania
3 shared publications - Daniel Muntean
Faculty of Civil Engineering, University Politehnica Timisoara, 300223 Timișoara, Romania
3 shared publications - Danut Tokar
Faculty of Civil Engineering, University Politehnica Timisoara, 300223 Timișoara, Romania
3 shared publications - Ramon-Mihai Balogh
Faculty of Mechanical Engineering, Universitatea Politehnica Timisoara, 300006 Timisoara, Romania
2 shared publications
Latest Publications
- Open Access
A Method for Estimating Gaseous Emissions in Multistory Car Parks, Based on Scenarios and Particularities: MB-UPT Case Study
The need to build multistory parking in congested areas of cities presents new challenges regarding the estimation of the impact of these investments on the environment and neighboring buildings. The authors synthesize the data available in the official EU documentation and in the scientific literature and propose a method for calculating polluting gaseous emissions generated in multistory car parks. For the case study targeting the MB-UPT car park, a scheme with functional blocks was created, with elements that quantitatively and qualitatively influence the polluting gaseous emissions (CO, CO2, NMVOC, NOx, NH3) generated by the operation of the car park. The study considers a fleet of motor vehicles with characteristics like those of the motor vehicles in the car park in Timiș County. The calculation method was applied considering three operating scenarios with high-level emissions, estimated to be encountered in real operation. Considering the operating modes of the motor vehicles, emission factors and correction coefficients were chosen for the highest possible degree of confidence in the emission estimates. The results are presented graphically and in tabular form. From the analysis of the results, for each pollutant species analyzed, the relevant critical factor was determined in the context of the three scenarios. The method proposed by the authors allows for the quantitative determination of polluting gaseous emissions and easy identification of episodes and zones with high emissions.
Open AccessA Method for Estimating Gaseous Emissions in Multistory Car Parks, Based on Scenarios and Particularities: MB-UPT Case Study
The need to build multistory parking in congested areas of cities presents new challenges regarding the estimation of the impact of these investments on the environment and neighboring buildings. The authors synthesize the data available in the official EU documentation and in the scientific literature and propose a method for calculating polluting gaseous emissions generated in multistory car parks. For the case study targeting the MB-UPT car park, a scheme with functional blocks was created, with elements that quantitatively and qualitatively influence the polluting gaseous emissions (CO, CO2, NMVOC, NOx, NH3) generated by the operation of the car park. The study considers a fleet of motor vehicles with characteristics like those of the motor vehicles in the car park in Timiș County. The calculation method was applied considering three operating scenarios with high-level emissions, estimated to be encountered in real operation. Considering the operating modes of the motor vehicles, emission factors and correction coefficients were chosen for the highest possible degree of confidence in the emission estimates. The results are presented graphically and in tabular form. From the analysis of the results, for each pollutant species analyzed, the relevant critical factor was determined in the context of the three scenarios. The method proposed by the authors allows for the quantitative determination of polluting gaseous emissions and easy identification of episodes and zones with high emissions.
- Open Access
- 26 February 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (5) , 2269
Indoor Air Quality in Climbing Gyms: Multi-Zone Assessment of Particulate Matter, CO2 Accumulation, and User Perception
Indoor climbing gyms are high-occupancy settings, yet integrated indoor air quality (IAQ) studies that analyze objective exposure and occupant perception remain scarce. The novelty consists of combining user perception with multi-zone, high-resolution IAQ measurements. We investigated a climbing gym in Romania to (i) quantify particulate matter (PM1, PM2.5, PM10) and carbon dioxide (CO2), (ii) compare natural and mechanical ventilation under real operating conditions with per capita normalization, (iii) relate exposure to occupancy and user perception, and (iv) coupling continuous optical monitoring with 24 h gravimetric and morphological/chemical analyses (scanning electron microscopy, confocal microscopy, X-ray fluorescence, and inductively coupled plasma mass spectrometry). The gravimetric 24 h reference measurements (EN 12341:2014) showed that daily means for PM2.5 and PM10 were 1.9–2.0× and 2.3–2.8× higher than the WHO guideline values, which confirms persistent daily particulate loads. Mechanical ventilation reduced coarse PM and CO2, but absolute PM remained elevated and fine fractions persisted. CO2 revealed a near-uniform vertical mixing, confirming dilution but indicating that CO2 is not a surrogate for particulate exposure. Survey responses from occupants revealed a gap between perception and reality: most of the users rated IAQ as good despite high PM. This study is among the few integrations of perception of IAQ for climbing gyms and the first comprehensive assessment in Romania, providing evidence-based recommendations on ventilation and filtration upgrades, chalk use management, and dust-reservoir control, thus creating sparkling interest for IAQ researchers, building services engineers, sports facilities operators, and policymakers.
- 26 February 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (5) , 2269
Open AccessIndoor Air Quality in Climbing Gyms: Multi-Zone Assessment of Particulate Matter, CO2 Accumulation, and User Perception
Indoor climbing gyms are high-occupancy settings, yet integrated indoor air quality (IAQ) studies that analyze objective exposure and occupant perception remain scarce. The novelty consists of combining user perception with multi-zone, high-resolution IAQ measurements. We investigated a climbing gym in Romania to (i) quantify particulate matter (PM1, PM2.5, PM10) and carbon dioxide (CO2), (ii) compare natural and mechanical ventilation under real operating conditions with per capita normalization, (iii) relate exposure to occupancy and user perception, and (iv) coupling continuous optical monitoring with 24 h gravimetric and morphological/chemical analyses (scanning electron microscopy, confocal microscopy, X-ray fluorescence, and inductively coupled plasma mass spectrometry). The gravimetric 24 h reference measurements (EN 12341:2014) showed that daily means for PM2.5 and PM10 were 1.9–2.0× and 2.3–2.8× higher than the WHO guideline values, which confirms persistent daily particulate loads. Mechanical ventilation reduced coarse PM and CO2, but absolute PM remained elevated and fine fractions persisted. CO2 revealed a near-uniform vertical mixing, confirming dilution but indicating that CO2 is not a surrogate for particulate exposure. Survey responses from occupants revealed a gap between perception and reality: most of the users rated IAQ as good despite high PM. This study is among the few integrations of perception of IAQ for climbing gyms and the first comprehensive assessment in Romania, providing evidence-based recommendations on ventilation and filtration upgrades, chalk use management, and dust-reservoir control, thus creating sparkling interest for IAQ researchers, building services engineers, sports facilities operators, and policymakers.
- Open Access
- 4 February 2026
- Published by MDPI AG in Chemosensors
- Vol. 14 (2) , 44
Low-Cost Particulate Matter and Gas Sensor Systems for Roadside Environmental Monitoring: Mechanistic and Predictive Insights from One-Year Urban Measurements
Roadside public transport stops represent localized air pollution hotspots where short-term exposure may differ substantially from levels reported by urban background monitoring. This study investigates the application of low-cost air quality sensors for long-term characterization of particulate matter and gaseous pollutants in a traffic-dominated urban microenvironment. The novelty of this work lies in the combined use of collocated low-cost sensors, energy-independent solar-powered deployment, height-resolved placement representative of different breathing zones, and integrated statistical and predictive analysis to resolve exposure-relevant pollutant dynamics at a single transport stop. Hourly concentrations of particulate matter (PM) PM1, PM2.5, PM10, nitrogen dioxide (NO2), and ozone (O3) were measured over one year at a roadside transport stop adjacent to a four-lane urban road carrying approximately 30,000 vehicles per day. Measurements were obtained using two collocated low-cost sensor units based on optical particle sensing for particulate matter and electrochemical sensing for gases, together with concurrent meteorological observations. Strong agreement between the two particulate matter sensors supported the use of averaged concentrations. Mean PM2.5 concentrations were substantially higher in winter (32.4 µg/m3) than in summer (10.4 µg/m3), indicating pronounced seasonal variability. PM1 and PM2.5 exhibited closely aligned temporal patterns, while PM10 showed greater variability. NO2 displayed sharp diurnal peaks associated with traffic activity, whereas O3 exhibited opposing seasonal and diurnal behavior and was negatively correlated with both PM2.5 (r = −0.32) and NO2 (r = −0.29). One-hour-ahead predictive models incorporating meteorological and temporal variables achieved coefficients of determination up to 0.84. The results demonstrate that energy-independent low-cost sensor systems can robustly capture temporal patterns, pollutant interactions, and short-term predictability in localized roadside environments relevant to exposure assessment.
- 4 February 2026
- Published by MDPI AG in Chemosensors
- Vol. 14 (2) , 44
Open AccessLow-Cost Particulate Matter and Gas Sensor Systems for Roadside Environmental Monitoring: Mechanistic and Predictive Insights from One-Year Urban Measurements
Roadside public transport stops represent localized air pollution hotspots where short-term exposure may differ substantially from levels reported by urban background monitoring. This study investigates the application of low-cost air quality sensors for long-term characterization of particulate matter and gaseous pollutants in a traffic-dominated urban microenvironment. The novelty of this work lies in the combined use of collocated low-cost sensors, energy-independent solar-powered deployment, height-resolved placement representative of different breathing zones, and integrated statistical and predictive analysis to resolve exposure-relevant pollutant dynamics at a single transport stop. Hourly concentrations of particulate matter (PM) PM1, PM2.5, PM10, nitrogen dioxide (NO2), and ozone (O3) were measured over one year at a roadside transport stop adjacent to a four-lane urban road carrying approximately 30,000 vehicles per day. Measurements were obtained using two collocated low-cost sensor units based on optical particle sensing for particulate matter and electrochemical sensing for gases, together with concurrent meteorological observations. Strong agreement between the two particulate matter sensors supported the use of averaged concentrations. Mean PM2.5 concentrations were substantially higher in winter (32.4 µg/m3) than in summer (10.4 µg/m3), indicating pronounced seasonal variability. PM1 and PM2.5 exhibited closely aligned temporal patterns, while PM10 showed greater variability. NO2 displayed sharp diurnal peaks associated with traffic activity, whereas O3 exhibited opposing seasonal and diurnal behavior and was negatively correlated with both PM2.5 (r = −0.32) and NO2 (r = −0.29). One-hour-ahead predictive models incorporating meteorological and temporal variables achieved coefficients of determination up to 0.84. The results demonstrate that energy-independent low-cost sensor systems can robustly capture temporal patterns, pollutant interactions, and short-term predictability in localized roadside environments relevant to exposure assessment.
- Open Access
Experimental Study on the Sustainability of Harnessing the Thermal Potential of Surface Waters for Building Decarbonization
One of the important stages of energy efficiency measures for buildings is the optimal choice of heating and cooling systems, as well as that of heat/cold production sources, so as to minimize dependence on conventional fuels and the national energy system. Currently, the option for integrating renewable energy sources addressed in the building efficiency stage is the installation of solar systems. In the context of the need to reduce energy consumption and reduce pollutant emissions, and the need to integrate renewable energy sources, the article addresses the implementation of a hybrid system with a water-to-water heat pump and photovoltaic panels, capable of achieving the decarbonization of the heating/cooling of a University Politehnica Timisoara teaching/research laboratory. The analyzed hybrid system uses the thermal potential of the Bega channel as a heat/cold source, and as a source for electricity production, a PV system, supported by the national energy system. Following the analysis of the operation of the building’s hybrid system for heating and cooling, during 4 November 2024–12 September 2025, an energy independence of approximately 90.7% and a reduction in CO2 emissions of 4.17 t/year was found.
Open AccessExperimental Study on the Sustainability of Harnessing the Thermal Potential of Surface Waters for Building Decarbonization
One of the important stages of energy efficiency measures for buildings is the optimal choice of heating and cooling systems, as well as that of heat/cold production sources, so as to minimize dependence on conventional fuels and the national energy system. Currently, the option for integrating renewable energy sources addressed in the building efficiency stage is the installation of solar systems. In the context of the need to reduce energy consumption and reduce pollutant emissions, and the need to integrate renewable energy sources, the article addresses the implementation of a hybrid system with a water-to-water heat pump and photovoltaic panels, capable of achieving the decarbonization of the heating/cooling of a University Politehnica Timisoara teaching/research laboratory. The analyzed hybrid system uses the thermal potential of the Bega channel as a heat/cold source, and as a source for electricity production, a PV system, supported by the national energy system. Following the analysis of the operation of the building’s hybrid system for heating and cooling, during 4 November 2024–12 September 2025, an energy independence of approximately 90.7% and a reduction in CO2 emissions of 4.17 t/year was found.
- Open Access
- 16 August 2025
- Published by MDPI AG in Atmosphere
- Vol. 16 (8) , 972
Real-Time Insights into Indoor Air Quality in University Environments: PM and CO2 Monitoring
This study presents real-time measurements of particulate matter (PM1, PM2.5, PM10) and carbon dioxide (CO2) concentrations across five university indoor environments with varying occupancy levels and natural ventilation conditions. CO2 concentrations frequently exceeded the 1000 ppm guideline, with peak values reaching 3018 ppm and 2715 ppm in lecture spaces, whereas one workshop environment maintained levels well below limits (mean = 668 ppm). PM concentrations varied widely: PM10 reached 541.5 µg/m3 in a carpeted amphitheater, significantly surpassing the 50 µg/m3 legal daily limit, while a well-ventilated classroom exhibited lower levels despite moderate occupancy (PM10 max = 116.9 µg/m3). Elevated PM values were strongly associated with flooring type and occupant movement, not just activity type. Notably, window ventilation during breaks reduced CO2 concentrations by up to 305 ppm (p < 1 × 10−47) and PM10 by over 20% in rooms with favorable layouts. These findings highlight the importance of ventilation strategy, spatial orientation, and surface materials in shaping indoor air quality. The study emphasizes the need for targeted, non-invasive interventions to reduce pollutant exposure in historic university buildings where mechanical ventilation upgrades are often restricted.
- 16 August 2025
- Published by MDPI AG in Atmosphere
- Vol. 16 (8) , 972
Open AccessReal-Time Insights into Indoor Air Quality in University Environments: PM and CO2 Monitoring
This study presents real-time measurements of particulate matter (PM1, PM2.5, PM10) and carbon dioxide (CO2) concentrations across five university indoor environments with varying occupancy levels and natural ventilation conditions. CO2 concentrations frequently exceeded the 1000 ppm guideline, with peak values reaching 3018 ppm and 2715 ppm in lecture spaces, whereas one workshop environment maintained levels well below limits (mean = 668 ppm). PM concentrations varied widely: PM10 reached 541.5 µg/m3 in a carpeted amphitheater, significantly surpassing the 50 µg/m3 legal daily limit, while a well-ventilated classroom exhibited lower levels despite moderate occupancy (PM10 max = 116.9 µg/m3). Elevated PM values were strongly associated with flooring type and occupant movement, not just activity type. Notably, window ventilation during breaks reduced CO2 concentrations by up to 305 ppm (p < 1 × 10−47) and PM10 by over 20% in rooms with favorable layouts. These findings highlight the importance of ventilation strategy, spatial orientation, and surface materials in shaping indoor air quality. The study emphasizes the need for targeted, non-invasive interventions to reduce pollutant exposure in historic university buildings where mechanical ventilation upgrades are often restricted.
- 21 November 2024
- Published by Springer Nature
- p. 161-169
Roof up or Down: Exploring Particulate Matter and Noise Pollution Dynamics in Convertible Vehicles
- 21 November 2024
- Published by Springer Nature
- p. 161-169
Roof up or Down: Exploring Particulate Matter and Noise Pollution Dynamics in Convertible Vehicles
- Open Access
Decarbonization of Heating and Cooling Systems of Buildings Located Nearby Surface Water Sources: Case Study
The study was carried out to evaluate theoretically and in laboratory conditions the capacity of a hybrid heating and cooling system that sustainably uses thermal energy extracted from surface waters in order to decarbonize buildings located near water sources. The novelty of the research consists in the realization of two experimental systems, one for the rapid evaluation of the performance of the water–water heat pump heating system and one for the evaluation of the operating behavior of a cooling system with fan coil units. Starting with the heating and cooling demand, and the climatic and hydrological local characteristics, a hybrid system model for the heating and cooling of the analyzed building was established and implemented. The forecasted energy consumption and CO2 emissions for the operation of the new equipment were compared with the historical values of the old systems with which the building was equipped (thermal energy supply from the district heating and cooling system with an air conditioning unit). Also, the results were extrapolated for forecasting the energy potential of the surface waters. The study highlights a percentage reduction in annual energy consumption of 67.71% and CO2 emissions of 80.13% through the implementation of the hybrid system.
Open AccessDecarbonization of Heating and Cooling Systems of Buildings Located Nearby Surface Water Sources: Case Study
The study was carried out to evaluate theoretically and in laboratory conditions the capacity of a hybrid heating and cooling system that sustainably uses thermal energy extracted from surface waters in order to decarbonize buildings located near water sources. The novelty of the research consists in the realization of two experimental systems, one for the rapid evaluation of the performance of the water–water heat pump heating system and one for the evaluation of the operating behavior of a cooling system with fan coil units. Starting with the heating and cooling demand, and the climatic and hydrological local characteristics, a hybrid system model for the heating and cooling of the analyzed building was established and implemented. The forecasted energy consumption and CO2 emissions for the operation of the new equipment were compared with the historical values of the old systems with which the building was equipped (thermal energy supply from the district heating and cooling system with an air conditioning unit). Also, the results were extrapolated for forecasting the energy potential of the surface waters. The study highlights a percentage reduction in annual energy consumption of 67.71% and CO2 emissions of 80.13% through the implementation of the hybrid system.
- Open Access
- 1 February 2022
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2212 (1) , 012004
Indoor air quality research within a furniture factory
Improving conditions and quality of life depends, among others, on the environment. People spend most of their time in a day inside buildings to work, sleep, eat, rest, and do sports and other activities. The article refers to a case study based on research on indoor environment within a furniture factory; the research is achieved via instruments for collecting diverse indoor parameters, such as temperature, CO2, PM (particulate matter) concentrations, noise, and humidity levels. All data recorded are needed to evaluate the conditions of the indoor climate in which the workers are activating. The measuring methods are shortly introduced and the IAQ (indoor air quality) index is expressed. The personnel activating in this factory is working intensely, standing up, and having to wear a mask considering the Covid-19 context. Thus, it is important to depict each aspect that might trigger a concern if IAQ limits are over passed, not mentioning the synergetic context of the diverse effects. Through revealing the IAQ, and the comfort/discomfort level PMV/PPD (predicted mean vote and predicted percentage dissatisfied) employees and company management can benefit from this awareness and enhance the behaviour in such a way that one might improve the indoor condition. The rapid and irreversible climate changes, mostly due to increasing pollution level and exhaust of greenhouse gases should push humanity to make more studies of this kind and, accordingly, realize the need of improvement and development of new solutions whereby one can sustain the indoor environment as proper as possible, in addition to the outdoor climate.
- 1 February 2022
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2212 (1) , 012004
Open AccessIndoor air quality research within a furniture factory
Improving conditions and quality of life depends, among others, on the environment. People spend most of their time in a day inside buildings to work, sleep, eat, rest, and do sports and other activities. The article refers to a case study based on research on indoor environment within a furniture factory; the research is achieved via instruments for collecting diverse indoor parameters, such as temperature, CO2, PM (particulate matter) concentrations, noise, and humidity levels. All data recorded are needed to evaluate the conditions of the indoor climate in which the workers are activating. The measuring methods are shortly introduced and the IAQ (indoor air quality) index is expressed. The personnel activating in this factory is working intensely, standing up, and having to wear a mask considering the Covid-19 context. Thus, it is important to depict each aspect that might trigger a concern if IAQ limits are over passed, not mentioning the synergetic context of the diverse effects. Through revealing the IAQ, and the comfort/discomfort level PMV/PPD (predicted mean vote and predicted percentage dissatisfied) employees and company management can benefit from this awareness and enhance the behaviour in such a way that one might improve the indoor condition. The rapid and irreversible climate changes, mostly due to increasing pollution level and exhaust of greenhouse gases should push humanity to make more studies of this kind and, accordingly, realize the need of improvement and development of new solutions whereby one can sustain the indoor environment as proper as possible, in addition to the outdoor climate.