Liangjie Lin
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Liangjie Lin has a total of 71 co-authors. Here are the top co-authors by number of shared publications:
- Jiazheng Wang
Clinical & Technical Support, Philips Healthcare, Beijing, China
5 shared publications - Zhong Chen
Xiamen University
4 shared publications - Qingwei Song
Department of Radiology, The First Affiliated Hospital of Dalian Medical University, Dalian, China
3 shared publications - Yanqin Lin
Xiamen University
3 shared publications - Ailian Liu
Department of Radiology, the First Affiliated Hospital of Dalian Medical University
2 shared publications - Bing Zhang
Department of Radiology, Nanjing Drum Tower Hospital Clinical College of Nanjing University of Chinese Medicine, Nanjing, China
2 shared publications
Latest Publications
- 20 December 2024
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 46 (1) , 41-48
Deep Learning–Based Super-Resolution Reconstruction on Undersampled Brain Diffusion-Weighted MRI for Infarction Stroke: A Comparison to Conventional Iterative Reconstruction
BACKGROUND AND PURPOSE: DWI is crucial for detecting infarction stroke. However, its spatial resolution is often limited, hindering accurate lesion visualization. Our aim was to evaluate the image quality and diagnostic confidence of deep learning (DL)-based super-resolution reconstruction for brain DWI of infarction stroke. MATERIALS AND METHODS: This retrospective study enrolled 114 consecutive participants who underwent brain DWI. The DWI images were reconstructed with 2 schemes: 1) DL-based super-resolution reconstruction (DWIDL); and 2) conventional compressed sensing reconstruction (DWICS). Qualitative image analysis included overall image quality, lesion conspicuity, and diagnostic confidence in infarction stroke of different lesion sizes. Quantitative image quality assessments were performed by measurements of SNR, contrast-to-noise ratio (CNR), ADC, and edge rise distance. Group comparisons were conducted by using a paired t test for normally distributed data and the Wilcoxon test for non-normally distributed data. The overall agreement between readers for qualitative ratings was assessed by using the Cohen κ coefficient. A P value less than .05 was considered statistically significant. RESULTS: A total of 114 DWI examinations constituted the study cohort. For the qualitative assessment, overall image quality, lesion conspicuity, and diagnostic confidence in infarction stroke lesions (lesion size DL compared with DWICS (all P < .001). For the quantitative analysis, edge rise distance of DWIDL was reduced compared with that of DWICS (P < .001), and no significant difference in SNR, CNR, and ADC values (all P > .05). CONCLUSIONS: Compared with the conventional compressed sensing reconstruction, the DL-based super-resolution reconstruction demonstrated superior image quality and was feasible for achieving higher diagnostic confidence in infarction stroke.
- 20 December 2024
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 46 (1) , 41-48
Deep Learning–Based Super-Resolution Reconstruction on Undersampled Brain Diffusion-Weighted MRI for Infarction Stroke: A Comparison to Conventional Iterative Reconstruction
BACKGROUND AND PURPOSE: DWI is crucial for detecting infarction stroke. However, its spatial resolution is often limited, hindering accurate lesion visualization. Our aim was to evaluate the image quality and diagnostic confidence of deep learning (DL)-based super-resolution reconstruction for brain DWI of infarction stroke. MATERIALS AND METHODS: This retrospective study enrolled 114 consecutive participants who underwent brain DWI. The DWI images were reconstructed with 2 schemes: 1) DL-based super-resolution reconstruction (DWIDL); and 2) conventional compressed sensing reconstruction (DWICS). Qualitative image analysis included overall image quality, lesion conspicuity, and diagnostic confidence in infarction stroke of different lesion sizes. Quantitative image quality assessments were performed by measurements of SNR, contrast-to-noise ratio (CNR), ADC, and edge rise distance. Group comparisons were conducted by using a paired t test for normally distributed data and the Wilcoxon test for non-normally distributed data. The overall agreement between readers for qualitative ratings was assessed by using the Cohen κ coefficient. A P value less than .05 was considered statistically significant. RESULTS: A total of 114 DWI examinations constituted the study cohort. For the qualitative assessment, overall image quality, lesion conspicuity, and diagnostic confidence in infarction stroke lesions (lesion size DL compared with DWICS (all P < .001). For the quantitative analysis, edge rise distance of DWIDL was reduced compared with that of DWICS (P < .001), and no significant difference in SNR, CNR, and ADC values (all P > .05). CONCLUSIONS: Compared with the conventional compressed sensing reconstruction, the DL-based super-resolution reconstruction demonstrated superior image quality and was feasible for achieving higher diagnostic confidence in infarction stroke.
- Open Access
- 1 May 2024
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 14 (5) , 3417-3431
Spiral time-of-flight magnetic resonance angiography for intracranial vascular imaging: performance compared to conventional Cartesian angiogram
Background: Computed tomography angiography (CTA) and digital subtraction angiography (DSA) usually raise the risk of potential malignancies with cumulative radiation doses. Current time-of-flight magnetic resonance angiography (TOF-MRA) (dubbed as cTOF), which is based on Cartesian sampling mode, may show limited diagnostic conspicuity at sinuous or branching regions. It is also prone to relatively high false positive diagnoses and undesirable display of distal intracranial vessels. This study aimed to use spiral TOF-MRA (sTOF) as a noninvasive alternative to explore possible improvement, such that the application of magnetic resonance angiography (MRA) can be extended to facilitate clinical examination or cerebrovascular disease diagnosis and follow-up studies. Methods: Initially, 37 patients with symptoms of dizziness or transient ischemic attack were consecutively recruited for suspected intracranial vascular disease examination from Zhongshan Hospital of Xiamen University between July 2020 and April 2021 in this cross-sectional prospective study. After excluding 1 patient with severe scanning artifacts, 1 patient whose scanning scope did not meet the requirement, and 1 patient with confounding tumor lesions, a total of 34 participants were included according to the inclusion and exclusion criteria. Each participant underwent intracranial vascular imaging with both sTOF and cTOF sequences on a 3.0 T MR scanner with a conventional head-neck coil of 16 channels. Contrast CTA or DSA was also performed for 15 patients showing pathology. Qualitative comparisons in terms of image quality and diagnostic efficacy ratings, quantitative comparisons in terms of signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), vessel length, and sharpness were evaluated. Pair-wise Wilcoxon test was performed to evaluate the imaging quality derived from cTOF and sTOF acquisitions and weighted Cohen’s Kappa was conducted to assess the rating consistency between different physicians. Results: Compared to cTOF, sTOF showed better performance with fewer artifacts. It can effectively alleviate false positives of normal vessels being misdiagnosed as aneurysm or stenosis. Improved conspicuity was observed in cerebral distal regions with more clearly identifiable vasculature at finer scales. Quantitative comparisons in selected regions revealed significant improvement of sTOF in SNR (PConclusions: The sTOF shows higher imaging quality and lesion detectability with reduced artifacts and false positives, representing a potentially feasible surrogate in intracranial vascular imaging for future clinic routines.
- 1 May 2024
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 14 (5) , 3417-3431
Open AccessSpiral time-of-flight magnetic resonance angiography for intracranial vascular imaging: performance compared to conventional Cartesian angiogram
Background: Computed tomography angiography (CTA) and digital subtraction angiography (DSA) usually raise the risk of potential malignancies with cumulative radiation doses. Current time-of-flight magnetic resonance angiography (TOF-MRA) (dubbed as cTOF), which is based on Cartesian sampling mode, may show limited diagnostic conspicuity at sinuous or branching regions. It is also prone to relatively high false positive diagnoses and undesirable display of distal intracranial vessels. This study aimed to use spiral TOF-MRA (sTOF) as a noninvasive alternative to explore possible improvement, such that the application of magnetic resonance angiography (MRA) can be extended to facilitate clinical examination or cerebrovascular disease diagnosis and follow-up studies. Methods: Initially, 37 patients with symptoms of dizziness or transient ischemic attack were consecutively recruited for suspected intracranial vascular disease examination from Zhongshan Hospital of Xiamen University between July 2020 and April 2021 in this cross-sectional prospective study. After excluding 1 patient with severe scanning artifacts, 1 patient whose scanning scope did not meet the requirement, and 1 patient with confounding tumor lesions, a total of 34 participants were included according to the inclusion and exclusion criteria. Each participant underwent intracranial vascular imaging with both sTOF and cTOF sequences on a 3.0 T MR scanner with a conventional head-neck coil of 16 channels. Contrast CTA or DSA was also performed for 15 patients showing pathology. Qualitative comparisons in terms of image quality and diagnostic efficacy ratings, quantitative comparisons in terms of signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), vessel length, and sharpness were evaluated. Pair-wise Wilcoxon test was performed to evaluate the imaging quality derived from cTOF and sTOF acquisitions and weighted Cohen’s Kappa was conducted to assess the rating consistency between different physicians. Results: Compared to cTOF, sTOF showed better performance with fewer artifacts. It can effectively alleviate false positives of normal vessels being misdiagnosed as aneurysm or stenosis. Improved conspicuity was observed in cerebral distal regions with more clearly identifiable vasculature at finer scales. Quantitative comparisons in selected regions revealed significant improvement of sTOF in SNR (PConclusions: The sTOF shows higher imaging quality and lesion detectability with reduced artifacts and false positives, representing a potentially feasible surrogate in intracranial vascular imaging for future clinic routines.
- 3 August 2023
- Published by International Society for Magnetic Resonance in Medicine (ISMRM)
MRS Denoising Model: ReLSTM-Net Trained by few In vivo Measured Data
1H Magnetic Resonance Spectroscopy (MRS) suffers low Signal-Noise Ratio (SNR) due to low concentrations of metabolites. To improve the SNR, the current mainstream is to do Signal Averaging with repeated samplings but it is time-consuming. Therefore, we designed a novel denoising ReLSTM-Net to learn the mapping from the low SNR MRS to the high SNR one in the time-domain by a few in vivo measured data. Denoised spectra by the proposed method has higher accuracy and reliability in quantifying metabolites Glx, tCho and mI, compared with the state-of-art Low-Rank method.
- 3 August 2023
- Published by International Society for Magnetic Resonance in Medicine (ISMRM)
MRS Denoising Model: ReLSTM-Net Trained by few In vivo Measured Data
1H Magnetic Resonance Spectroscopy (MRS) suffers low Signal-Noise Ratio (SNR) due to low concentrations of metabolites. To improve the SNR, the current mainstream is to do Signal Averaging with repeated samplings but it is time-consuming. Therefore, we designed a novel denoising ReLSTM-Net to learn the mapping from the low SNR MRS to the high SNR one in the time-domain by a few in vivo measured data. Denoised spectra by the proposed method has higher accuracy and reliability in quantifying metabolites Glx, tCho and mI, compared with the state-of-art Low-Rank method.
- 3 August 2023
- Published by International Society for Magnetic Resonance in Medicine (ISMRM)
Single shot multiple overlapping-echo acquisition combined with deep learning for ultra-fast T2 mapping in glioma: A preliminary study
Quantitative MRI (qMRI) are expected largely to provide more accuracy clinical diagnostic information. However, bound by the relative long duration for the routine MRI exam and much longer qMRI acquisition time, the qMRI is not widely used for diagnostic purpose. The change of MR signal caused by contrast agent extravasation is affected by many factors, which will increase difficulty in diagnosis. Quantitative MRI (qMRI) are expected to overcome this issue. Recently, an ultra-fast multi-parameters qMRI technique was developed by our group, and herein we aim to apply the proposed strategy on brain tumor imaging and to preliminary access the potential performance.
- 3 August 2023
- Published by International Society for Magnetic Resonance in Medicine (ISMRM)
Single shot multiple overlapping-echo acquisition combined with deep learning for ultra-fast T2 mapping in glioma: A preliminary study
Quantitative MRI (qMRI) are expected largely to provide more accuracy clinical diagnostic information. However, bound by the relative long duration for the routine MRI exam and much longer qMRI acquisition time, the qMRI is not widely used for diagnostic purpose. The change of MR signal caused by contrast agent extravasation is affected by many factors, which will increase difficulty in diagnosis. Quantitative MRI (qMRI) are expected to overcome this issue. Recently, an ultra-fast multi-parameters qMRI technique was developed by our group, and herein we aim to apply the proposed strategy on brain tumor imaging and to preliminary access the potential performance.
- 3 August 2023
- Published by International Society for Magnetic Resonance in Medicine (ISMRM)
Cross-Linked Protoporphyrin IX polymer as Efficient, Tunable CEST MRI NanoPlatform for molecular Imaging
CEST MRI is an novel molecular imaging technique in which the contrast is generated by the dynamic exchange between the exchangeable proton and water. Porphyrin and its analogues are a promising class of highly sensitive, diamagnetic CEST agents with highly upfield shifted protons. We synthesized a water-soluble polymeric CEST MRI agent grafted with protoporphyrin IX(PpIX). The PpIX polymeric agent resonated at -13.5 ppm from water and showed excellent CEST MRI properties.
- 3 August 2023
- Published by International Society for Magnetic Resonance in Medicine (ISMRM)
Cross-Linked Protoporphyrin IX polymer as Efficient, Tunable CEST MRI NanoPlatform for molecular Imaging
CEST MRI is an novel molecular imaging technique in which the contrast is generated by the dynamic exchange between the exchangeable proton and water. Porphyrin and its analogues are a promising class of highly sensitive, diamagnetic CEST agents with highly upfield shifted protons. We synthesized a water-soluble polymeric CEST MRI agent grafted with protoporphyrin IX(PpIX). The PpIX polymeric agent resonated at -13.5 ppm from water and showed excellent CEST MRI properties.
- 3 August 2023
- Published by International Society for Magnetic Resonance in Medicine (ISMRM)
Amide proton transfer and diffusion kurtosis imaging technology in differentiation stage Ia endometrial carcinoma and endometrial polyp
Endometrial polyps (EP) is a common disease of uterine body, with a prevalence rate of about 8~25% in female population. Its clinical symptoms can be like those of endometrial carcinoma (EC), with vaginal bleeding, but there are obvious differences in prognosis and treatment between them. The purpose of this study is to investigate the value of differential diagnosis for staging Ia EC and EP by using amide proton transfer (APT) and diffusion kurtosis imaging (DKI). It shows that APT and DKI can be used to distinguish between stage Ia EC and EP. effectively and quantitatively
- 3 August 2023
- Published by International Society for Magnetic Resonance in Medicine (ISMRM)
Amide proton transfer and diffusion kurtosis imaging technology in differentiation stage Ia endometrial carcinoma and endometrial polyp
Endometrial polyps (EP) is a common disease of uterine body, with a prevalence rate of about 8~25% in female population. Its clinical symptoms can be like those of endometrial carcinoma (EC), with vaginal bleeding, but there are obvious differences in prognosis and treatment between them. The purpose of this study is to investigate the value of differential diagnosis for staging Ia EC and EP by using amide proton transfer (APT) and diffusion kurtosis imaging (DKI). It shows that APT and DKI can be used to distinguish between stage Ia EC and EP. effectively and quantitatively
- 3 March 2022
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 43 (3) , 402-409
Acceleration of Brain Susceptibility-Weighted Imaging with Compressed Sensitivity Encoding: A Prospective Multicenter Study
BACKGROUND AND PURPOSE: While three-dimensional susceptibility-weighted imaging has been widely suggested for intracranial vessel imaging, hemorrhage detection, and other neuro-diseases, its relatively long scan time has necessitated the clinical verification of recent progresses of fast imaging techniques. Our aim was to evaluate the effectiveness of brain SWI accelerated by compressed sensitivity encoding to identify the optimal acceleration factors for clinical practice. MATERIALS AND METHODS: Ninety-nine subjects, prospectively enrolled from 5 centers, underwent 8 brain SWI sequences: 5 different folds of compressed sensitivity encoding acceleration (CS2, CS4, CS6, CS8, and CS10), 2 different folds of sensitivity encoding acceleration (SF2 and SF4), and 1 without acceleration. Images were assessed quantitatively on both the SNR of the red nucleus and its contrast ratio to the CSF and, subjectively, with scoring on overall image quality; visibility of the substantia nigra–red nucleus, basilar artery, and internal cerebral vein; and diagnostic confidence of the cerebral microbleeds and other intracranial diseases. RESULTS: Compressed sensitivity encoding showed a promising ability to reduce the acquisition time (from 202 to 41 seconds) of SWI while increasing the acceleration factor from 2 to 10, though at the cost of decreasing the SNR, contrast ratio, and the scores of visual assessments. The visibility of the substantia nigra–red nucleus and internal cerebral vein became unacceptable in CS6 to CS10. The basilar artery was well-distinguished, and diseases including cerebral microbleeds, cavernous angiomas, intracranial gliomas, venous malformations, and subacute hemorrhage were well-diagnosed in all compressed sensitivity encoding sequences. CONCLUSIONS: Compressed sensitivity encoding factor 4 is recommended in routine practice. Compressed sensitivity encoding factor 10 is potentially a fast surrogate for distinguishing the basilar artery and detecting susceptibility-related abnormalities (eg, cerebral microbleeds, cavernous angiomas, gliomas, and venous malformation) at the sacrifice of visualization of the substantia nigra–red nucleus and internal cerebral vein.
- 3 March 2022
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 43 (3) , 402-409
Acceleration of Brain Susceptibility-Weighted Imaging with Compressed Sensitivity Encoding: A Prospective Multicenter Study
BACKGROUND AND PURPOSE: While three-dimensional susceptibility-weighted imaging has been widely suggested for intracranial vessel imaging, hemorrhage detection, and other neuro-diseases, its relatively long scan time has necessitated the clinical verification of recent progresses of fast imaging techniques. Our aim was to evaluate the effectiveness of brain SWI accelerated by compressed sensitivity encoding to identify the optimal acceleration factors for clinical practice. MATERIALS AND METHODS: Ninety-nine subjects, prospectively enrolled from 5 centers, underwent 8 brain SWI sequences: 5 different folds of compressed sensitivity encoding acceleration (CS2, CS4, CS6, CS8, and CS10), 2 different folds of sensitivity encoding acceleration (SF2 and SF4), and 1 without acceleration. Images were assessed quantitatively on both the SNR of the red nucleus and its contrast ratio to the CSF and, subjectively, with scoring on overall image quality; visibility of the substantia nigra–red nucleus, basilar artery, and internal cerebral vein; and diagnostic confidence of the cerebral microbleeds and other intracranial diseases. RESULTS: Compressed sensitivity encoding showed a promising ability to reduce the acquisition time (from 202 to 41 seconds) of SWI while increasing the acceleration factor from 2 to 10, though at the cost of decreasing the SNR, contrast ratio, and the scores of visual assessments. The visibility of the substantia nigra–red nucleus and internal cerebral vein became unacceptable in CS6 to CS10. The basilar artery was well-distinguished, and diseases including cerebral microbleeds, cavernous angiomas, intracranial gliomas, venous malformations, and subacute hemorrhage were well-diagnosed in all compressed sensitivity encoding sequences. CONCLUSIONS: Compressed sensitivity encoding factor 4 is recommended in routine practice. Compressed sensitivity encoding factor 10 is potentially a fast surrogate for distinguishing the basilar artery and detecting susceptibility-related abnormalities (eg, cerebral microbleeds, cavernous angiomas, gliomas, and venous malformation) at the sacrifice of visualization of the substantia nigra–red nucleus and internal cerebral vein.
- 18 January 2022
- Published by Wiley in NMR in Biomedicine
- Vol. 35 (6) , e4676
Evaluation of brown adipose tissue with intermolecular double‐quantum coherence magnetic resonance spectroscopy at 3.0 T
In the current study, we propose a single‐voxel (SV) magnetic resonance spectroscopy (MRS) pulse sequence, based on intermolecular double‐quantum coherence (iDQC), for in vivo specific assessment of brown adipose tissue (BAT) at 3 T. The multilocular adipocyte, present in BAT, typically contains a large number of small lipid droplets surrounded by abundant intracellular water, while the monolocular adipocyte, present in white adipose tissue (WAT), accommodates only a single large lipid droplet with much less water content. The SV‐iDQC sequence probes the spatial correlation between water and fat spins at a distance of about the size of an adipocyte, thus can be used for assessment of BAT, even when mixed with WAT and/or muscle tissues. This sequence for measurement of water‐to‐fat (water‐fat) iDQC signals was tested on phantoms and mouse BAT and WAT tissues. It was then used to differentiate adipose tissues in the supraclavicular and subcutaneous regions of healthy youth human volunteers (n = 6). Phantom results with water‐fat emulsions demonstrated enhanced water‐fat iDQC signal with increased voxel size, increased energy level of emulsification, or increased distribution balance of water and fat spins. The animal tissue experiments resulted in obvious water‐fat iDQC signal in mouse BAT, while this signal was almost absent in the WAT spectrum. The optimal choice of the dipolar coupling distance for the observation was approximately 100 μm, as tested on both emulsion phantom and animal tissue. The water‐fat iDQC signals observed in the supraclavicular adipose tissues were higher than in the subcutaneous adipose tissues in healthy young volunteers (0.43 ± 0.36 vs. 0.10 ± 0.06, p = 0.06). It was concluded that the iDQC‐based sequence has potential for assessment of mouse and human BAT at 3 T, which is of interest for clinical research and the diagnosis of obesity and associated diseases.
- 18 January 2022
- Published by Wiley in NMR in Biomedicine
- Vol. 35 (6) , e4676
Evaluation of brown adipose tissue with intermolecular double‐quantum coherence magnetic resonance spectroscopy at 3.0 T
In the current study, we propose a single‐voxel (SV) magnetic resonance spectroscopy (MRS) pulse sequence, based on intermolecular double‐quantum coherence (iDQC), for in vivo specific assessment of brown adipose tissue (BAT) at 3 T. The multilocular adipocyte, present in BAT, typically contains a large number of small lipid droplets surrounded by abundant intracellular water, while the monolocular adipocyte, present in white adipose tissue (WAT), accommodates only a single large lipid droplet with much less water content. The SV‐iDQC sequence probes the spatial correlation between water and fat spins at a distance of about the size of an adipocyte, thus can be used for assessment of BAT, even when mixed with WAT and/or muscle tissues. This sequence for measurement of water‐to‐fat (water‐fat) iDQC signals was tested on phantoms and mouse BAT and WAT tissues. It was then used to differentiate adipose tissues in the supraclavicular and subcutaneous regions of healthy youth human volunteers (n = 6). Phantom results with water‐fat emulsions demonstrated enhanced water‐fat iDQC signal with increased voxel size, increased energy level of emulsification, or increased distribution balance of water and fat spins. The animal tissue experiments resulted in obvious water‐fat iDQC signal in mouse BAT, while this signal was almost absent in the WAT spectrum. The optimal choice of the dipolar coupling distance for the observation was approximately 100 μm, as tested on both emulsion phantom and animal tissue. The water‐fat iDQC signals observed in the supraclavicular adipose tissues were higher than in the subcutaneous adipose tissues in healthy young volunteers (0.43 ± 0.36 vs. 0.10 ± 0.06, p = 0.06). It was concluded that the iDQC‐based sequence has potential for assessment of mouse and human BAT at 3 T, which is of interest for clinical research and the diagnosis of obesity and associated diseases.
- 15 April 2021
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 42 (7) , 1208-1215
Acceleration of Brain TOF-MRA with Compressed Sensitivity Encoding: A Multicenter Clinical Study
BACKGROUND AND PURPOSE: The clinical practice of three-dimensional TOF-MRA, despite its capability in brain artery assessment, has been hampered by the relatively long scan time, while recent developments in fast imaging techniques with random undersampling has shed light on an improved balance between image quality and imaging speed. Our aim was to evaluate the effectiveness of TOF-MRA accelerated by compressed sensitivity encoding and to identify the optimal acceleration factors for routine clinical use. MATERIALS AND METHODS: One hundred subjects, enrolled at 5 centers, underwent 8 brain TOF-MRA sequences: 5 sequences using compressed sensitivity encoding with acceleration factors of 2, 4, 6, 8, and 10 (CS2, CS4, CS6, CS8, and CS10), 2 using sensitivity encoding with factors of 2 and 4 (SF2 and SF4), and 1 without acceleration as a reference sequence (RS). Five large arteries, 6 medium arteries, and 6 small arteries were evaluated quantitatively (reconstructed signal intensity, structural similarity, contrast ratio) and qualitatively (scores on arteries, artifacts, overall image quality, and diagnostic confidence for aneurysm and stenosis). Comparisons were performed among the 8 sequences. RESULTS: The quantitative measurements showed that the reconstructed signal intensities of the assessed arteries and the structural similarity consistently decreased as the compressed sensitivity encoding acceleration factor increased, and no significant difference was found for the contrast ratios in pair-wise comparisons among SF2, CS2, and CS4. Qualitative evaluations showed no significant difference in pair-wise comparisons among RS, SF2, and CS2 (P > .05). The visualization of all the assessed arteries was acceptable for CS2 and CS4, while 2 small arteries in images of CS6 were not reliably displayed, and the visualization of large arteries was acceptable in images of CS8 and CS10. CONCLUSIONS: CS4 is recommended for routine brain TOF-MRA with balanced image quality and acquisition time; CS6, for examinations when small arteries are not evaluated; and CS10, for fast visualization of large arteries.
- 15 April 2021
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 42 (7) , 1208-1215
Acceleration of Brain TOF-MRA with Compressed Sensitivity Encoding: A Multicenter Clinical Study
BACKGROUND AND PURPOSE: The clinical practice of three-dimensional TOF-MRA, despite its capability in brain artery assessment, has been hampered by the relatively long scan time, while recent developments in fast imaging techniques with random undersampling has shed light on an improved balance between image quality and imaging speed. Our aim was to evaluate the effectiveness of TOF-MRA accelerated by compressed sensitivity encoding and to identify the optimal acceleration factors for routine clinical use. MATERIALS AND METHODS: One hundred subjects, enrolled at 5 centers, underwent 8 brain TOF-MRA sequences: 5 sequences using compressed sensitivity encoding with acceleration factors of 2, 4, 6, 8, and 10 (CS2, CS4, CS6, CS8, and CS10), 2 using sensitivity encoding with factors of 2 and 4 (SF2 and SF4), and 1 without acceleration as a reference sequence (RS). Five large arteries, 6 medium arteries, and 6 small arteries were evaluated quantitatively (reconstructed signal intensity, structural similarity, contrast ratio) and qualitatively (scores on arteries, artifacts, overall image quality, and diagnostic confidence for aneurysm and stenosis). Comparisons were performed among the 8 sequences. RESULTS: The quantitative measurements showed that the reconstructed signal intensities of the assessed arteries and the structural similarity consistently decreased as the compressed sensitivity encoding acceleration factor increased, and no significant difference was found for the contrast ratios in pair-wise comparisons among SF2, CS2, and CS4. Qualitative evaluations showed no significant difference in pair-wise comparisons among RS, SF2, and CS2 (P > .05). The visualization of all the assessed arteries was acceptable for CS2 and CS4, while 2 small arteries in images of CS6 were not reliably displayed, and the visualization of large arteries was acceptable in images of CS8 and CS10. CONCLUSIONS: CS4 is recommended for routine brain TOF-MRA with balanced image quality and acquisition time; CS6, for examinations when small arteries are not evaluated; and CS10, for fast visualization of large arteries.
- 1 May 2016
- Published by Elsevier in Chemical Physics Letters
- Vol. 652, 62-67
Fast acquisition of high-resolution 2D NMR spectroscopy in inhomogeneous magnetic fields
- 1 May 2016
- Published by Elsevier in Chemical Physics Letters
- Vol. 652, 62-67
Fast acquisition of high-resolution 2D NMR spectroscopy in inhomogeneous magnetic fields