Acceleration of Brain Susceptibility-Weighted Imaging with Compressed Sensitivity Encoding: A Prospective Multicenter Study
- 3 March 2022
- journal article
- research article
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 43 (3) , 402-409
Abstract
BACKGROUND AND PURPOSE: While three-dimensional susceptibility-weighted imaging has been widely suggested for intracranial vessel imaging, hemorrhage detection, and other neuro-diseases, its relatively long scan time has necessitated the clinical verification of recent progresses of fast imaging techniques. Our aim was to evaluate the effectiveness of brain SWI accelerated by compressed sensitivity encoding to identify the optimal acceleration factors for clinical practice. MATERIALS AND METHODS: Ninety-nine subjects, prospectively enrolled from 5 centers, underwent 8 brain SWI sequences: 5 different folds of compressed sensitivity encoding acceleration (CS2, CS4, CS6, CS8, and CS10), 2 different folds of sensitivity encoding acceleration (SF2 and SF4), and 1 without acceleration. Images were assessed quantitatively on both the SNR of the red nucleus and its contrast ratio to the CSF and, subjectively, with scoring on overall image quality; visibility of the substantia nigra–red nucleus, basilar artery, and internal cerebral vein; and diagnostic confidence of the cerebral microbleeds and other intracranial diseases. RESULTS: Compressed sensitivity encoding showed a promising ability to reduce the acquisition time (from 202 to 41 seconds) of SWI while increasing the acceleration factor from 2 to 10, though at the cost of decreasing the SNR, contrast ratio, and the scores of visual assessments. The visibility of the substantia nigra–red nucleus and internal cerebral vein became unacceptable in CS6 to CS10. The basilar artery was well-distinguished, and diseases including cerebral microbleeds, cavernous angiomas, intracranial gliomas, venous malformations, and subacute hemorrhage were well-diagnosed in all compressed sensitivity encoding sequences. CONCLUSIONS: Compressed sensitivity encoding factor 4 is recommended in routine practice. Compressed sensitivity encoding factor 10 is potentially a fast surrogate for distinguishing the basilar artery and detecting susceptibility-related abnormalities (eg, cerebral microbleeds, cavernous angiomas, gliomas, and venous malformation) at the sacrifice of visualization of the substantia nigra–red nucleus and internal cerebral vein.Keywords
Funding Information
- Beijing Nova Program
- National Science Foundation of China (7133244, 81571631, 81870958)
This publication has 32 references indexed in Scilit:
- Fast susceptibility-weighted imaging with three-dimensional short-axis propeller (SAP)-echo-planar imagingJournal of Magnetic Resonance Imaging, 2014
- MR Imaging of the Substantia Nigra at 7 T Enables Diagnosis of Parkinson DiseaseRadiology, 2014
- MR Susceptibility-Weighted Imaging (SWI) Complements Conventional Contrast Enhanced Imaging for Melanoma Gamma Knife Radiosurgery PlanningPractical Radiation Oncology, 2013
- Magnetic Resonance Imaging Evaluation of Cerebral Cavernous Malformations With Susceptibility-Weighted ImagingNeurosurgery, 2011
- Accuracy of Susceptibility-Weighted Imaging for the Detection of Arteriovenous Shunting in Vascular Malformations of the BrainStroke, 2011
- The veins of the nucleus dentatus: Anatomical and radiological findingsNeuroImage, 2011
- SPIRiT: Iterative self‐consistent parallel imaging reconstruction from arbitrary k‐spaceMagnetic Resonance in Medicine, 2010
- The Microbleed Anatomical Rating Scale (MARS)Neurology, 2009
- Susceptibility-Weighted Imaging: Technical Aspects and Clinical Applications, Part 1American Journal of Neuroradiology, 2008
- GRAPPA-based susceptibility-weighted imaging of normal volunteers and patients with brain tumor at 7 TMagnetic Resonance Imaging, 2008