JKJung-Hwa Kim

Jung-Hwa Kim

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jung-Hwa Kim has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Commissioning of edge Thomson scattering diagnostic system on Versatile Experiment Spherical Torus

    by Jongmin Lee, Young-Gi Kim, Jung-Hwa Kim, Jong Ha Lee, Yong-Seok Hwang

    An edge Thomson scattering (TS) diagnostic system has been developed and commissioned on the Versatile Experiment Spherical Torus (VEST) to extend kinetic profile measurements into the edge region and scrape-off layer (SOL). The new system shares the existing laser injection system with the core TS (2 J, 10 ns, 10 bursts at 1 kHz) and is designed to cover the low-field-side radial range of R = 0.475 – 0.800 m, complementing the core TS coverage of R = 0.255 – 0.475 m. Absolute calibration of the new edge TS system was performed via rotational Raman scattering measurements. To validate consistency between the two collection optics systems, 150 datasets acquired from 15 discharges at the same radial position (R = 0.475 m; core 1 and edge 1) were analyzed using a chi-square test of homogeneity. The results indicate agreement within uncertainties for both electron density and temperature. As an initial commissioning demonstration, pilot operation measurements were performed at four radial positions (R = 0.255, 0.370, 0.475 and 0.700 m) and produced edge electron density and electron temperature profiles over a 10 ms period. The installation of the edge TS system enables a wider spatial coverage (R = 0.255 – 0.800 m) for more detailed kinetic profiling, with planned expansion through additional polychromators to increase the number of measurement points and support future studies such as edge transport and instabilities.

  • Relative calibration correction using fast LEDs to enhance the reliability of Thomson scattering diagnostic on KSTAR

    by Jung-Hwa Kim, Jong-Ha Lee, Young-Gi Kim, Hajin Kim, Geunhyeong Park

    A Thomson scattering diagnostic system on KSTAR has been operated to measure the electron temperature and density profiles, which are among the most essential parameters in the study of fusion plasmas. The system was optimized by employing a fast digitizer for full-pulse fitting and by performing absolute calibration with rotational Raman scattering. While performing the Raman calibration, a discrepancy between filters 1 and 2 at the edge polychromators was observed, suggesting limited reliability of the calibration. Moreover, the distribution of minimum chi-square values, which quantify the statistical goodness of fit of the electron parameter measurements, deviated noticeably from the theoretical expectation, particularly for certain polychromators. These discrepancies were attributed to a systematic error in the relative responsivity of polychromators, caused by differences in pulse duration between the pulsed laser and the halogen lamp, which was used for relative calibration. To address this issue, the relative responsivity was corrected using fast LEDs with a pulse waveform similar to that of the laser. As a result, the reliability of the electron temperature and density obtained after the correction was enhanced.

  • Development of a multi-channel visible bremsstrahlung measurement system for the effective charge in the versatile experiment spherical torus (VEST)

    by J. W. Yoo, C. Sung, T. H. Eom, W. S. Lee, J. H. Kim, J. H. Byun, W. I. Jeong, Hong-Sik Yun, Jae Young Jang, T. K. Kim, et al.

    A diagnostic system for measuring the effective charge in the versatile experiment spherical torus (VEST) has been developed. The system utilizes a toroidal array to observe the plasma radius on the low magnetic field side, providing a spatially resolved Zeff. The target wavelength of visible bremsstrahlung (VB) was carefully selected to avoid contamination by line emissions. The detector signal was calibrated using a halogen light source and an integrating sphere to obtain an absolute value of the radiative power from each chord. The local emissivity profile was reconstructed from the line-integrated VB emission using the Abel inversion method. Reconstruction tests were performed on various shapes of phantom profiles to effectively reconstruct the local emissivity from the measurements. We found that the initial measurements of the multi-channel VB system were consistent with the results of other independent measurements, supporting the validity of the new measurements. Finally, we obtained the initial result of Zeff in the VEST.


  • Simultaneous measurements of temporal evolutions of the voltage and the current on the load of the Seoul National University X-pinch device using the optics-based systems

    by Seongmin Choi, Seunggi Ham, Jonghyeon Ryu, Sungbin Park, Jung-Hwa Kim, YeongHwan Choi, Muhyeop Cha, Seungmin Bong, Kyoung-Jae Chung, Y. S. Hwang, et al.

    Optics-based measurement systems have been developed to measure the voltage and the current on a load of the Seoul National University X-pinch device [Ryu et al., Rev. Sci. Instrum. 92, 053533 (2021)]. A lithium niobate crystal that changes the polarization state of the propagating laser beam due to the Pockels effect induced by the electric field across the crystal, thus capable of measuring the voltage, is located next to the load. For the current measurement, an optic fiber is wound around the load to detect the change in the polarization state of the propagating laser beam due to the Faraday rotation induced by the magnetic field. As both voltage and current measurement systems utilize optical effects, the sensors, i.e., the lithium niobate crystal and the optic fiber, do not require any electrical grounds, in contrast to circuit-based probes, such as voltage dividers or Rogowski grooves. This facilitates an easy access to shield other required electronic devices, such as lasers and photodetectors, from the electromagnetic interference generated by the X-pinch power system. In addition, the sensors can be placed in close proximity to the load with fewer concerns on the electrical insulation. Temporal evolutions of the simultaneously measured voltage and current on the load of the X-pinch are successfully obtained and discussed.


  • Systematic Error Analysis of Thomson Scattering System on VEST With Rotational Raman Calibration

    by Jung-Hwa Kim, Jongmin Lee, Young-Gi Kim, SeongCheol Kim, Jongin Wang, J. H. Lee, Y. S. Hwang

    The Thomson scattering (TS) system is a main plasma diagnostic tool used on the Versatile Experiment Spherical Torus (VEST). An upgrade to the 1 kHz TS system has been completed, allowing for the measurement of rapidly changing radial profiles of the electron temperature and density in the core plasma. Additionally, the upgrade of the bandpass filters of the polychromators enables rotational Raman scattering (RRS) calibration, which improves the accuracy of density calibration compared to Rayleigh scattering (RS) methods. However, systematic errors in the relative sensitivity calibration can lead to significant changes in the results. By analyzing discrepancies in the Raman calibration signals for three filters, the causes of these errors are identified and corrected with a fast infrared (IR) LED. As a result, the calibration factors for RRS and their uncertainties are obtained for measuring absolute electron density, and the relative responsivity of each polychromator is corrected to increase the reliability of the TS system.


  • Radial profile measurement with an improved 1 kHz Thomson scattering system on Versatile Experiment Spherical Torus

    by Jung-Hwa Kim, Young-Gi Kim, Doyeon Kim, Jong-Ha Lee, Y. S. Hwang

    A Thomson scattering (TS) system has been utilized to measure the electron temperature and density of the core region of Versatile Experiment Spherical Torus (VEST). Recently, the laser injection system is successfully upgraded adopting the burst laser with the repetition rate of 1 kHz and the energy of 2 J. Furthermore, improved collection optics with additional polychromators and a 32-channel fast digitizer are prepared to observe the fast time evolution of radial profiles. This improvement is essential to study fast phenomena such as internal reconnection event (IRE). We increase the TS signal and reduce the stray light by introducing new filters having better optical properties such as high optical density at 1064 nm, transmission, and reflectance. Moreover, the optimum reverse bias voltages are newly set to make the system operational independent of the background radiation. As a result, 1 kHz radial profiles of the core electron temperature and density are measured for the first time, showing characteristics of IREs in VEST.