YSYao Sun

Yao Sun

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yao Sun has a total of 48 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Edge-Hosted LLM-Assisted NICU Discharge Summary Generation: Field-Level Evaluation Using a Clinician-Defined Rubric

    by Harpreet Singh, Ravneet Kaur, Satish Saluja, Su Jin Cho, Yao Sun, Ryan M. McAdams

    Objective: To develop and evaluate an edge-hosted Large Language Model (LLM)-assisted system for automated Neonatal Intensive Care Unit (NICU) discharge summary generation using an evidence-grounded, field-level evaluation framework. Methods: This implementation and evaluation study was conducted in a Level III NICU in India. Longitudinal patient records were constructed from integrated bedside physiologic data (ARCHITECT) and a structured electronic medical record (EMR) platform Although an embedded audio–video module was present, it was not used in this study. Automated discharge summaries were generated by MORPHEUS, an edge-hosted orchestration pipeline running on NVIDIA Jetson AGX Orin hardware with JetPack 6.2. Local orchestration, preprocessing, and workflow execution were performed on the edge device, while language generation inference was performed using the OpenAI gpt-4o-mini API. Documentation quality was assessed with an LLM-based evaluator guided by a clinician-defined rubric comprising 72 fields organized across 14 section contexts and scored on five dimensions: clinical accuracy, completeness, actionability, coherence, and non-hallucination. Paired, field-level comparisons were performed against clinician-authored summaries. Of 549 NICU admissions screened between 1 October 2024 and 3 November 2025, 401 met the inclusion criteria for evaluation. Prompt refinement was performed iteratively using omission-derived feedback without model weight updates. Results: Across 401 evaluated admissions, MORPHEUS-generated summaries demonstrated higher rubric-based scores and lower omission burden than clinician-authored summaries within the structured evaluation framework used in this study, with mean scores of 0.93 versus 0.75 for accuracy, 0.91 versus 0.67 for completeness, 0.93 versus 0.72 for actionability, 0.94 versus 0.74 for coherence, and 0.95 versus 0.78 for non-hallucination, with the largest absolute advantage observed for completeness. Error taxonomy analysis demonstrated fewer omissions, unsupported assertions, and contradictions in AI-generated summaries than in clinician-authored summaries. Iterative prompt refinement was associated with directional improvement across quality dimensions and reduced omission burden, with omission rate per patient decreasing from 2.484 to 1.807 in the later iteration. Conclusions: An edge-hosted LLM-assisted pipeline can generate NICU discharge summaries that meet or exceed clinician-authored documentation quality under a reproducible, clinician-grounded evaluation framework. These findings support the feasibility of deploying edge-orchestrated generative AI systems for high-stakes neonatal clinical documentation using a clinician-grounded field-level evaluation framework.


  • Open Access

    What parents want to know about caring for their preterm infant: A longitudinal descriptive study

    by Stephannie L. Furtak, Caryl L. Gay, Rebecca M. Kriz, Robin Bisgaard, Scott C. Bolick, Brittany Lothe, Diana M. Cormier, Priscilla Joe, Juliet K. Sasinski, Jae H. Kim, et al.


  • Open Access

    Machine Learning-Based Automatic Classification of Video Recorded Neonatal Manipulations and Associated Physiological Parameters: A Feasibility Study

    by Harpreet Singh, Satoshi Kusuda, Ryan M. McAdams, Shubham Gupta, Jayant Kalra, Ravneet Kaur, Ritu Das, Saket Anand, Ashish Kumar Pandey, Su Jin Cho, et al.

    Our objective in this study was to determine if machine learning (ML) can automatically recognize neonatal manipulations, along with associated changes in physiological parameters. A retrospective observational study was carried out in two Neonatal Intensive Care Units (NICUs) between December 2019 to April 2020. Both the video and physiological data (heart rate (HR) and oxygen saturation (SpO2)) were captured during NICU hospitalization. The proposed classification of neonatal manipulations was achieved by a deep learning system consisting of an Inception-v3 convolutional neural network (CNN), followed by transfer learning layers of Long Short-Term Memory (LSTM). Physiological signals prior to manipulations (baseline) were compared to during and after manipulations. The validation of the system was done using the leave-one-out strategy with input of 8 s of video exhibiting manipulation activity. Ten neonates were video recorded during an average length of stay of 24.5 days. Each neonate had an average of 528 manipulations during their NICU hospitalization, with the average duration of performing these manipulations varying from 28.9 s for patting, 45.5 s for a diaper change, and 108.9 s for tube feeding. The accuracy of the system was 95% for training and 85% for the validation dataset. In neonates 2, and, for neonates ≥32 weeks’ gestation, patting and tube feeding were associated with significant changes in HR. The presented system can classify and document the manipulations with high accuracy. Moreover, the study suggests that manipulations impact physiological parameters.


  • Open Access

    Efficacy of prostaglandina E1 for the treatment of patients with thrombo-occlusive vasculitis

    by Yao Mb Sun, Han-Rui Mm Wang, Xiao-Hang Mb Feng, Kai-Feng Mm Wang

    Background: This study aims to explore the efficacy and safety of prostaglandina E1 (PE1) for the treatment of patients with thrombo-occlusive vasculitis (TOV). Methods: Electronic databases (Cochrane Library, PUBMED, EMBASE, Web of Science, Scopus, the Allied and Complementary Medicine Database, Chinese Biomedical Literature Database, and China National Knowledge Infrastructure) will be sought from onset to the March 1, 2020 without language and publication status restrictions. We will include any potential randomized controlled trials that examined the efficacy of PE1 for the treatment of patients with TOV. We will appraise study quality using Cochrane risk of bias tool, and will assess the evidence quality using Grading of Recommendations Assessment Development and Evaluation. We will use RevMan 5.3 Software for statistical analysis. Results: A high-quality synthesis of present evidence of PE1 for the treatment of patients with TOV will be provided in this study. Conclusion: This study will provide evidence to judge whether PE1 is an effective intervention for TOV. Systematic review registration: INPLASY202040081.

  • Open Access

    Comparison of family centered care with family integrated care and mobile technology (mFICare) on preterm infant and family outcomes: a multi-site quasi-experimental clinical trial protocol

    by Linda S. Franck, Rebecca M. Kriz, Robin Bisgaard, Diana M. Cormier, Priscilla Joe, Pamela S. Miller, Jae H. Kim, Carol Lin, Yao Sun

    Background: Family Centered Care (FCC) has been widely adopted as the framework for caring for infants in the Neonatal Intensive Care Unit (NICU) but it is not uniformly defined or practiced, making it difficult to determine impact. Previous studies have shown that implementing the Family Integrated Care (FICare) intervention program for preterm infants in the NICU setting leads to significant improvements in infant and family outcomes. Further research is warranted to determine feasibility, acceptability and differential impact of FICare in the US context. The addition of a mobile application (app) may be effective in providing supplemental support for parent participation in the FICare program and provide detailed data on program component uptake and outcomes.Methods: This exploratory multi-site quasi-experimental study will compare usual FCC with mobile enhanced FICare (mFICare) on growth and clinical outcomes of preterm infants born at or before 33 weeks gestational age, as well as the stress, competence and self-efficacy of their parents. The feasibility and acceptability of using mobile technology to gather data about parent involvement in the care of preterm infants receiving FCC or mFICare as well as of the mFICare intervention will be evaluated (Aim 1). The effect sizes for infant growth (primary outcome) and for secondary infant and parent outcomes at NICU discharge and three months after discharge will be estimated (Aim 2).Discussion: This study will provide new data about the implementation of FICare in the US context within various hospital settings and identify important barriers, facilitators and key processes that may contribute to the effectiveness of FICare. It will also offer insights to clinicians on the feasibility of a new mobile application to support parent-focused research and promote integration of parents into the NICU care team in US hospital settings.Trial registration: ClinicalTrials.gov, IDNCT03418870. Retrospectively registered on December 18, 2017.