Jérôme Joseph Waterval
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jérôme Joseph Waterval has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Henricus P. M. Kunst
Department of Otorhinolaryngology, Head & Neck Surgery, Radboud University Medical Center for Brain and Senses, P.O. Box 9101, 6525 EX Nijmegen, The Netherlands, The Netherlands
2 shared publications - Alida A. Postma
Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, 6229 HX Maastricht, The Netherlands
1 shared publication Angélica Pérez Fornos
Division of Otorhinolaryngology-Head and Neck Surgery, Department of Clinical Neurosciences, Geneva University Hospitals, University of Geneva, Geneva, Switzerland
1 shared publication- Cristina Mitea
GROW—Research Institute for Oncology and Reproduction, Maastricht University, 6229 HX Maastricht, The Netherlands
1 shared publication - Joost Johannes Antonius Stultiens
Department of Otorhinolaryngology-Head and Neck Surgery, School for Mental Health and Neuroscience, Faculty of Health Medicine and Life Sciences, Maastricht University Medical Center, Maastricht, The Netherlands
1 shared publication - Koos Hovinga
Department of Neurosurgery, Maastricht University Medical Center, 6202 AZ Maastricht, The Netherlands
1 shared publication
Latest Publications
- Open Access
- 8 May 2026
- Published by SAGE Publications in Journal of Otolaryngology - Head & Neck Surgery
- Vol. 55
A Hand-Guided Robotic Drill for Vestibular Implant Surgery—Feasibility of Preventing Membranous Labyrinth Rupture
Importance: Progress in vestibular implantation offers hope for patients with bilateral vestibulopathy. However, surgically opening the semicircular canals risks breaching the membranous labyrinth, which may induce sensorineural hearing loss. A robotic drill sensing force and torque might prevent membranous labyrinth rupture. Primary objective: To assess the feasibility of force- and torque-based automatic cessation in a hand-guided robotic drill for fenestrating the bony semicircular canals without rupturing the membranous labyrinth. Secondary objective: To fit an electrode dummy through the fenestrations. Design: Feasibility study using human cadaveric temporal bones. Setting: Laboratory. Participants: Ten formalin-fixed human temporal bones. Intervention: After performing a cortical mastoidectomy and skeletonizing the semicircular canals, a hand-guided robotic drill was used to drill 2 fenestrations in each semicircular canal. A silicone electrode dummy was inserted through each fenestration. Main outcome measures: Proportion of fenestrations with intact membranous labyrinth, as evaluated with a surgical microscope. Proportion of fenestrations allowing electrode insertion without additional manipulation. Results: A total of 60 fenestrations were made in 30 semicircular canals from 10 temporal bones. Technical issues related to drill bit fixation occurred in 6 fenestrations. The remaining 54 fenestrations were all made without visible damage to the membranous labyrinth. In 81% of these fenestrations (44/54), the electrode could be advanced without requiring additional manipulation. The technical issue was related to improper alignment of the drill bit, leading to incorrect force and torque sensing. Conclusions: Force- and torque-based automatic cessation in a hand-guided robotic drill is feasible for fenestrating the bony semicircular canals without rupturing the membranous labyrinth. However, improved burr fixation is required for consistent and reliable performance. Relevance: The investigated approach holds potential to improve safety and precision in semicircular canal surgery, such as vestibular implantation. This may expand treatment options for patients with residual inner ear function.
- 8 May 2026
- Published by SAGE Publications in Journal of Otolaryngology - Head & Neck Surgery
- Vol. 55
Open AccessA Hand-Guided Robotic Drill for Vestibular Implant Surgery—Feasibility of Preventing Membranous Labyrinth Rupture
Importance: Progress in vestibular implantation offers hope for patients with bilateral vestibulopathy. However, surgically opening the semicircular canals risks breaching the membranous labyrinth, which may induce sensorineural hearing loss. A robotic drill sensing force and torque might prevent membranous labyrinth rupture. Primary objective: To assess the feasibility of force- and torque-based automatic cessation in a hand-guided robotic drill for fenestrating the bony semicircular canals without rupturing the membranous labyrinth. Secondary objective: To fit an electrode dummy through the fenestrations. Design: Feasibility study using human cadaveric temporal bones. Setting: Laboratory. Participants: Ten formalin-fixed human temporal bones. Intervention: After performing a cortical mastoidectomy and skeletonizing the semicircular canals, a hand-guided robotic drill was used to drill 2 fenestrations in each semicircular canal. A silicone electrode dummy was inserted through each fenestration. Main outcome measures: Proportion of fenestrations with intact membranous labyrinth, as evaluated with a surgical microscope. Proportion of fenestrations allowing electrode insertion without additional manipulation. Results: A total of 60 fenestrations were made in 30 semicircular canals from 10 temporal bones. Technical issues related to drill bit fixation occurred in 6 fenestrations. The remaining 54 fenestrations were all made without visible damage to the membranous labyrinth. In 81% of these fenestrations (44/54), the electrode could be advanced without requiring additional manipulation. The technical issue was related to improper alignment of the drill bit, leading to incorrect force and torque sensing. Conclusions: Force- and torque-based automatic cessation in a hand-guided robotic drill is feasible for fenestrating the bony semicircular canals without rupturing the membranous labyrinth. However, improved burr fixation is required for consistent and reliable performance. Relevance: The investigated approach holds potential to improve safety and precision in semicircular canal surgery, such as vestibular implantation. This may expand treatment options for patients with residual inner ear function.
- Open Access
- 30 September 2022
- Published by Scientific Scholar in Surgical Neurology International
- Vol. 13, 441
A rare complication after vestibular schwannoma surgery: Neurogenic pulmonary edema
In our center, large vestibular schwannoma (VS) is typically managed by a planned partial resection through the translabyrinthine route. Here, we report on a rare complication of VS surgery and severe neurogenic pulmonary edema. A 33-year-old male was referred to our skull-base center with a large VS. A planned partial resection was performed. The surgery was without complications and the patient showed good recovery without facial nerve dysfunction. In the evening of the 2nd day after surgery, the patient showed rapid neurological deterioration, accompanied by cardiac arrest. After the patient was resuscitated, a computed tomography (CT) was made, which showed generalized (infra- and supratentorial) brain edema and hematoma in the resection cavity. Despite rapid removal of the hematoma, there was no change in the neurological situation. The next CT scan showed a further increase of brain edema and the patient died eventually. Autopsy revealed generalized lung edema, brain edema, and Hashimoto’s thyroiditis. The pathologist diagnosed neurogenic lung edema. Neurogenic lung edema can occur on the 2nd day after surgery and induce rapid deterioration of the patient with massive brain edema.
- 30 September 2022
- Published by Scientific Scholar in Surgical Neurology International
- Vol. 13, 441
Open AccessA rare complication after vestibular schwannoma surgery: Neurogenic pulmonary edema
In our center, large vestibular schwannoma (VS) is typically managed by a planned partial resection through the translabyrinthine route. Here, we report on a rare complication of VS surgery and severe neurogenic pulmonary edema. A 33-year-old male was referred to our skull-base center with a large VS. A planned partial resection was performed. The surgery was without complications and the patient showed good recovery without facial nerve dysfunction. In the evening of the 2nd day after surgery, the patient showed rapid neurological deterioration, accompanied by cardiac arrest. After the patient was resuscitated, a computed tomography (CT) was made, which showed generalized (infra- and supratentorial) brain edema and hematoma in the resection cavity. Despite rapid removal of the hematoma, there was no change in the neurological situation. The next CT scan showed a further increase of brain edema and the patient died eventually. Autopsy revealed generalized lung edema, brain edema, and Hashimoto’s thyroiditis. The pathologist diagnosed neurogenic lung edema. Neurogenic lung edema can occur on the 2nd day after surgery and induce rapid deterioration of the patient with massive brain edema.
- Open Access
- 25 April 2021
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 279 (3) , 1323-1328
Diagnosing necrotizing external otitis on CT and MRI: assessment of pattern of extension
Background and purpose: Necrotizing external otitis (NEO) is a serious complication of external otitis. NEO can be classified according to—anterior, medial, posterior, intracranial, and contralateral—extension patterns. Currently there is no consensus on the optimal imaging modality for the identification of disease extension. This study compares NEO extension patterns on MR and CT to evaluate diagnostic comparability. Methods: Patients who received a CT and MR within a 3-month interval were retrospectively examined. Involvement of subsites and subsequent spreading patterns were assessed on both modalities by a radiologist in training and by a senior head and neck radiologist. The prevalence of extension patterns on CT and MR were calculated and compared. Results: All 21 included NEO cases showed an anterior extension pattern on CT and MR. Contrary to MR, medial extension was not recognized on CT in two out of six patients, and intracranial extension in five out of eight patients. The posterior extension pattern was not recognized on MR. Overall, single anterior extension pattern (62%) is more prevalent than multiple extension patterns (38%). Conclusion: All anterior NEO extension pattern were identified on CT as well as MR. However, the medial and intracranial spreading patterns as seen on MR could only be identified on CT in a small number of patients. The posterior spreading pattern can be overlooked on MR. Thus, CT and MR are complimentary for the initial diagnosis and work-up of NEO as to correctly delineate disease extent through the skull base.
- 25 April 2021
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 279 (3) , 1323-1328
Open AccessDiagnosing necrotizing external otitis on CT and MRI: assessment of pattern of extension
Background and purpose: Necrotizing external otitis (NEO) is a serious complication of external otitis. NEO can be classified according to—anterior, medial, posterior, intracranial, and contralateral—extension patterns. Currently there is no consensus on the optimal imaging modality for the identification of disease extension. This study compares NEO extension patterns on MR and CT to evaluate diagnostic comparability. Methods: Patients who received a CT and MR within a 3-month interval were retrospectively examined. Involvement of subsites and subsequent spreading patterns were assessed on both modalities by a radiologist in training and by a senior head and neck radiologist. The prevalence of extension patterns on CT and MR were calculated and compared. Results: All 21 included NEO cases showed an anterior extension pattern on CT and MR. Contrary to MR, medial extension was not recognized on CT in two out of six patients, and intracranial extension in five out of eight patients. The posterior extension pattern was not recognized on MR. Overall, single anterior extension pattern (62%) is more prevalent than multiple extension patterns (38%). Conclusion: All anterior NEO extension pattern were identified on CT as well as MR. However, the medial and intracranial spreading patterns as seen on MR could only be identified on CT in a small number of patients. The posterior spreading pattern can be overlooked on MR. Thus, CT and MR are complimentary for the initial diagnosis and work-up of NEO as to correctly delineate disease extent through the skull base.