Ulrike Boehm
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ulrike Boehm has a total of 301 co-authors. Here are the top co-authors by number of shared publications:
- Roland Nitschke
Signalling Research Centres CIBSS and BIOSS, University of Freiburg, Freiburg, Germany
12 shared publications - Glyn Nelson
Bioimaging Unit, Newcastle University, Newcastle upon Tyne, UK
11 shared publications - Caterina Strambio-De-Castillia
Program in Molecular Medicine, University of Massachusetts Chan Medical School, Worcester, USA
10 shared publications - Orestis Faklaris
MRI, Biocampus, University of Montpellier, CNRS, INSERM, Montpellier, France
9 shared publications - Claire M. Brown
McGill University
8 shared publications - David Grunwald
RNA Therapeutics Institute, UMass Chan Medical School, Worcester, MA, USA
8 shared publications
Latest Publications
- Open Access
- 30 March 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1) , 2589
Compartmentalized cytoplasmic tradewinds direct soluble proteins
Proteins essential for signaling, morphogenesis, and migration traverse the complex intracellular landscape via vesicular trafficking, microtubule-based transport, and diffusion. However, the precise mechanisms guiding soluble proteins toward their functional destinations have remained elusive. Here, we demonstrate that soluble proteins are directed toward the cell’s advancing edge through advection—diffusion enhanced by intracellular fluid flow. We reveal that advective transport occurs within a specialized compartment at the cell’s leading edge, separated from the rest of the cytoplasm by an actin-myosin condensate barrier. The barrier limits protein mixing between the compartment and the rest of the cytoplasm, maintaining localized protein concentrations. Contraction at the barrier generates a molecularly non-specific fluid flow that drives the forward movement of treadmilling actin monomers, actin-binding proteins, adhesion molecules, and even inert proteins. Dynamic changes in the local curvature of the barrier steer the fluid flow to direct proteins toward protrusive regions of the leading edge. This advective mechanism synchronizes protein distribution with local changes in cell morphology. Outside this compartment, diffusion dominates as the principal mode of soluble protein transport. Our findings uncover previously unrecognized compartmentalization strategies that regulate soluble protein concentrations and coordinate their efficient distribution for homeostasis, protrusion, and adhesion.
- 30 March 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1) , 2589
Open AccessCompartmentalized cytoplasmic tradewinds direct soluble proteins
Proteins essential for signaling, morphogenesis, and migration traverse the complex intracellular landscape via vesicular trafficking, microtubule-based transport, and diffusion. However, the precise mechanisms guiding soluble proteins toward their functional destinations have remained elusive. Here, we demonstrate that soluble proteins are directed toward the cell’s advancing edge through advection—diffusion enhanced by intracellular fluid flow. We reveal that advective transport occurs within a specialized compartment at the cell’s leading edge, separated from the rest of the cytoplasm by an actin-myosin condensate barrier. The barrier limits protein mixing between the compartment and the rest of the cytoplasm, maintaining localized protein concentrations. Contraction at the barrier generates a molecularly non-specific fluid flow that drives the forward movement of treadmilling actin monomers, actin-binding proteins, adhesion molecules, and even inert proteins. Dynamic changes in the local curvature of the barrier steer the fluid flow to direct proteins toward protrusive regions of the leading edge. This advective mechanism synchronizes protein distribution with local changes in cell morphology. Outside this compartment, diffusion dominates as the principal mode of soluble protein transport. Our findings uncover previously unrecognized compartmentalization strategies that regulate soluble protein concentrations and coordinate their efficient distribution for homeostasis, protrusion, and adhesion.
- 25 February 2026
- Published by Rockefeller University Press in Journal of Cell Biology
- Vol. 225 (3)
Better reporting is better science: Community-defined minimal reporting requirements for light microscopy
Incomplete reporting of microscopy methods undermines transparency, reproducibility, and data reuse. Despite recent initiatives, comprehensive, broadly endorsed, and accessible reporting guidelines are still lacking. Here, we present a bare minimal microscopy reporting requirements checklist that integrates human- and machine-readable input to provide clear, actionable guidance for researchers, reviewers, and publishers and to advance community standards in microscopy.
- 25 February 2026
- Published by Rockefeller University Press in Journal of Cell Biology
- Vol. 225 (3)
Better reporting is better science: Community-defined minimal reporting requirements for light microscopy
Incomplete reporting of microscopy methods undermines transparency, reproducibility, and data reuse. Despite recent initiatives, comprehensive, broadly endorsed, and accessible reporting guidelines are still lacking. Here, we present a bare minimal microscopy reporting requirements checklist that integrates human- and machine-readable input to provide clear, actionable guidance for researchers, reviewers, and publishers and to advance community standards in microscopy.
- Open Access
Compartmentalized Cytoplasmic Flows Direct Protein Transport to the Cell’s Leading Edge
Inside the cell, proteins essential for signaling, morphogenesis, and migration navigate complex pathways, typically via vesicular trafficking or microtubule-driven mechanisms 1–3 . However, the process by which soluble cytoskeletal monomers maneuver through the cytoplasm’s ever-changing environment to reach their destinations without using these pathways remains unknown. 4–6 Here, we show that actin cytoskeletal treadmilling leads to the formation of a semi-permeable actin-myosin barrier, creating a specialized compartment separated from the rest of the cell body that directs proteins toward the cell edge by advection, diffusion facilitated by fluid flow. Contraction at this barrier generates a molecularly non-specific fluid flow that transports actin, actin-binding proteins, adhesion proteins, and even inert proteins forward. The local curvature of the barrier specifically targets these proteins toward protruding edges of the leading edge, sites of new filament growth, effectively coordinating protein distribution with cellular dynamics. Outside this compartment, diffusion remains the primary mode of protein transport, contrasting sharply with the directed advection within. This discovery reveals a novel protein transport mechanism that redefines the front of the cell as a pseudo-organelle, actively orchestrating protein mobilization for cellular front activities such as protrusion and adhesion. By elucidating a new model of protein dynamics at the cellular front, this work contributes a critical piece to the puzzle of how cells adapt their internal structures for targeted and rapid response to extracellular cues. The findings challenge the current understanding of intracellular transport, suggesting that cells possess highly specialized and previously unrecognized organizational strategies for managing protein distribution efficiently, providing a new framework for understanding the cellular architecture’s role in rapid response and adaptation to environmental changes.
Open AccessCompartmentalized Cytoplasmic Flows Direct Protein Transport to the Cell’s Leading Edge
Inside the cell, proteins essential for signaling, morphogenesis, and migration navigate complex pathways, typically via vesicular trafficking or microtubule-driven mechanisms 1–3 . However, the process by which soluble cytoskeletal monomers maneuver through the cytoplasm’s ever-changing environment to reach their destinations without using these pathways remains unknown. 4–6 Here, we show that actin cytoskeletal treadmilling leads to the formation of a semi-permeable actin-myosin barrier, creating a specialized compartment separated from the rest of the cell body that directs proteins toward the cell edge by advection, diffusion facilitated by fluid flow. Contraction at this barrier generates a molecularly non-specific fluid flow that transports actin, actin-binding proteins, adhesion proteins, and even inert proteins forward. The local curvature of the barrier specifically targets these proteins toward protruding edges of the leading edge, sites of new filament growth, effectively coordinating protein distribution with cellular dynamics. Outside this compartment, diffusion remains the primary mode of protein transport, contrasting sharply with the directed advection within. This discovery reveals a novel protein transport mechanism that redefines the front of the cell as a pseudo-organelle, actively orchestrating protein mobilization for cellular front activities such as protrusion and adhesion. By elucidating a new model of protein dynamics at the cellular front, this work contributes a critical piece to the puzzle of how cells adapt their internal structures for targeted and rapid response to extracellular cues. The findings challenge the current understanding of intracellular transport, suggesting that cells possess highly specialized and previously unrecognized organizational strategies for managing protein distribution efficiently, providing a new framework for understanding the cellular architecture’s role in rapid response and adaptation to environmental changes.
- Open Access
- 19 January 2024
- Published by Springer Nature
Illumination Power, Stability, and Linearity Measurements for Confocal, Widefield and Multiphoton Microscopes v1
To obtain accurate, reproducible, and interpretable data when conducting imaging experiments, it is critical to consider external factors affecting data acquisition at various steps of the experimental workflow. Illumination power and stability represent two critical factors, especially when comparing fluorescence intensities between images during a time-lapse experiment or experiments performed at different times or on different microscopes. The fluorescence signal can be generated by different types of light sources. These light sources and their coupling elements (e.g., fibers) can display varying performances over time as they age, move, or as environmental conditions change. Unfortunately, microscope users can often only set illumination power as a percentage of its maximal output and may, therefore, not be aware of potential performance changes. It is important to recognize that a set percentage will not always yield the same illumination power in Watts at the objective over the course of an experiment, not to mention between days or systems. This means that selecting for example 10% output may lead to different experimental results over time or even between two microscopes of the same model. In addition to illumination stability, working within the linear range of the illumination power allows to adjust accurately the illumination power absolute value (in mW) using a fraction (or %) of its maximal value through the imaging software. If you are responsible for system maintenance, routinely measuring the illumination power, stability, and linearity over time can help you detect issues that affect the integrity of the system and thus the reproducibility of an experiment. This protocol describes how to measure the stability and linearity of the illumination power using calibrated external power sensors. This protocol is intended for confocal systems (raster scanning and spinning disks), Multi-photon systems (used for 2P- or 3P-imaging, SHG-imaging, etc.), and widefield systems. It represents the collective experience of over 50 imaging scientists.
- 19 January 2024
- Published by Springer Nature
Open AccessIllumination Power, Stability, and Linearity Measurements for Confocal, Widefield and Multiphoton Microscopes v1
To obtain accurate, reproducible, and interpretable data when conducting imaging experiments, it is critical to consider external factors affecting data acquisition at various steps of the experimental workflow. Illumination power and stability represent two critical factors, especially when comparing fluorescence intensities between images during a time-lapse experiment or experiments performed at different times or on different microscopes. The fluorescence signal can be generated by different types of light sources. These light sources and their coupling elements (e.g., fibers) can display varying performances over time as they age, move, or as environmental conditions change. Unfortunately, microscope users can often only set illumination power as a percentage of its maximal output and may, therefore, not be aware of potential performance changes. It is important to recognize that a set percentage will not always yield the same illumination power in Watts at the objective over the course of an experiment, not to mention between days or systems. This means that selecting for example 10% output may lead to different experimental results over time or even between two microscopes of the same model. In addition to illumination stability, working within the linear range of the illumination power allows to adjust accurately the illumination power absolute value (in mW) using a fraction (or %) of its maximal value through the imaging software. If you are responsible for system maintenance, routinely measuring the illumination power, stability, and linearity over time can help you detect issues that affect the integrity of the system and thus the reproducibility of an experiment. This protocol describes how to measure the stability and linearity of the illumination power using calibrated external power sensors. This protocol is intended for confocal systems (raster scanning and spinning disks), Multi-photon systems (used for 2P- or 3P-imaging, SHG-imaging, etc.), and widefield systems. It represents the collective experience of over 50 imaging scientists.
- Top Cited PapersOpen Access
- 14 September 2023
- Published by Springer Nature in Nature Methods
- Vol. 21 (2) , 170-181
Community-developed checklists for publishing images and image analyses
Images document scientific discoveries and are prevalent in modern biomedical research. Microscopy imaging in particular is currently undergoing rapid technological advancements. However, for scientists wishing to publish obtained images and image-analysis results, there are currently no unified guidelines for best practices. Consequently, microscopy images and image data in publications may be unclear or difficult to interpret. Here, we present community-developed checklists for preparing light microscopy images and describing image analyses for publications. These checklists offer authors, readers and publishers key recommendations for image formatting and annotation, color selection, data availability and reporting image-analysis workflows. The goal of our guidelines is to increase the clarity and reproducibility of image figures and thereby to heighten the quality and explanatory power of microscopy data.
- 14 September 2023
- Published by Springer Nature in Nature Methods
- Vol. 21 (2) , 170-181
Top Cited PapersOpen AccessCommunity-developed checklists for publishing images and image analyses
Images document scientific discoveries and are prevalent in modern biomedical research. Microscopy imaging in particular is currently undergoing rapid technological advancements. However, for scientists wishing to publish obtained images and image-analysis results, there are currently no unified guidelines for best practices. Consequently, microscopy images and image data in publications may be unclear or difficult to interpret. Here, we present community-developed checklists for preparing light microscopy images and describing image analyses for publications. These checklists offer authors, readers and publishers key recommendations for image formatting and annotation, color selection, data availability and reporting image-analysis workflows. The goal of our guidelines is to increase the clarity and reproducibility of image figures and thereby to heighten the quality and explanatory power of microscopy data.
- Open Access
- 15 March 2022
- Published by The Company of Biologists in Journal of Cell Science
- Vol. 135 (6)
When light meets biology – how the specimen affects quantitative microscopy
Fluorescence microscopy images should not be treated as perfect representations of biology. Many factors within the biospecimen itself can drastically affect quantitative microscopy data. Whereas some sample-specific considerations, such as photobleaching and autofluorescence, are more commonly discussed, a holistic discussion of sample-related issues (which includes less-routine topics such as quenching, scattering and biological anisotropy) is required to appropriately guide life scientists through the subtleties inherent to bioimaging. Here, we consider how the interplay between light and a sample can cause common experimental pitfalls and unanticipated errors when drawing biological conclusions. Although some of these discrepancies can be minimized or controlled for, others require more pragmatic considerations when interpreting image data. Ultimately, the power lies in the hands of the experimenter. The goal of this Review is therefore to survey how biological samples can skew quantification and interpretation of microscopy data. Furthermore, we offer a perspective on how to manage many of these potential pitfalls.
- 15 March 2022
- Published by The Company of Biologists in Journal of Cell Science
- Vol. 135 (6)
Open AccessWhen light meets biology – how the specimen affects quantitative microscopy
Fluorescence microscopy images should not be treated as perfect representations of biology. Many factors within the biospecimen itself can drastically affect quantitative microscopy data. Whereas some sample-specific considerations, such as photobleaching and autofluorescence, are more commonly discussed, a holistic discussion of sample-related issues (which includes less-routine topics such as quenching, scattering and biological anisotropy) is required to appropriately guide life scientists through the subtleties inherent to bioimaging. Here, we consider how the interplay between light and a sample can cause common experimental pitfalls and unanticipated errors when drawing biological conclusions. Although some of these discrepancies can be minimized or controlled for, others require more pragmatic considerations when interpreting image data. Ultimately, the power lies in the hands of the experimenter. The goal of this Review is therefore to survey how biological samples can skew quantification and interpretation of microscopy data. Furthermore, we offer a perspective on how to manage many of these potential pitfalls.
- Open Access
- 25 January 2022
- Published by The Company of Biologists in preLights
Janelia+EMBL BioImaging Seminar Series: How We Started a Successful Seminar Series during the Pandemic
Education - How we started a global BioImaging seminar series in the middle of a global pandemic...
- 25 January 2022
- Published by The Company of Biologists in preLights
Open AccessJanelia+EMBL BioImaging Seminar Series: How We Started a Successful Seminar Series during the Pandemic
Education - How we started a global BioImaging seminar series in the middle of a global pandemic...
- 3 January 2022
- Published by Springer Nature in Nature Methods
- Vol. 19 (2) , 255
Author Correction: Towards community-driven metadata standards for light microscopy: tiered specifications extending the OME model
- 3 January 2022
- Published by Springer Nature in Nature Methods
- Vol. 19 (2) , 255
Author Correction: Towards community-driven metadata standards for light microscopy: tiered specifications extending the OME model
- 3 January 2022
- Published by Springer Nature in Nature Methods
- Vol. 19 (2) , 256
Author Correction: QUAREP-LiMi: a community endeavor to advance quality assessment and reproducibility in light microscopy
- 3 January 2022
- Published by Springer Nature in Nature Methods
- Vol. 19 (2) , 256
Author Correction: QUAREP-LiMi: a community endeavor to advance quality assessment and reproducibility in light microscopy
- Open Access
- 24 December 2021
- Published by Springer Nature in Nature Methods
- Vol. 19 (2) , 256
Author Correction: Micro-Meta App: an interactive tool for collecting microscopy metadata based on community specifications
- 24 December 2021
- Published by Springer Nature in Nature Methods
- Vol. 19 (2) , 256
Open AccessAuthor Correction: Micro-Meta App: an interactive tool for collecting microscopy metadata based on community specifications