Jin-Tae Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jin-Tae Kim has a total of 324 co-authors. Here are the top co-authors by number of shared publications:
- John Allen Rogers
Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL, 60208, USA
22 shared publications - Yonggang Huang
Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA
15 shared publications - Leonardo P. Chamorro
University of Illinois
9 shared publications - Yoonseok Park
Department of Materials Science and Engineering, Kyung Hee University, Yongin 17104, Republic of Korea
9 shared publications Raudel Avila
7 shared publicationsHaiwen Luan
Querrey Simpson Institute for Bioelectronics, Northwestern University , Evanston, IL 60208 , USA
6 shared publications
Latest Publications
- Open Access
- 1 September 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1) , 10432
Shape memory polymer adhesives for on-demand, low-force detachment in skin-interfaced devices
Skin-interfaced biomedical devices require adhesives that provide strong attachment during use while enabling gentle removal with minimized subsurface skin deformation. Conventional medical adhesives lack mechanisms for on-demand adhesion modulation, often causing skin irritation and damage during detachment, particularly in vulnerable populations. Here, we present a thermally triggered shape memory polymer (SMP) adhesive that achieves reversible, high-contrast adhesion switching through programmable pyramidal structure recovery. The adhesive incorporates an array of pyramidal structures that remain flattened in a dormant state to ensure robust skin adhesion, but rapidly recover upon mild heating above the glass transition temperature, significantly reducing effective contact area and enabling low-force detachment. Adhesion switchability performances are supported by quantitative mechanical measurements, including reductions in peel force and adhesion energy after activation, as well as three-dimensional digital image correlation (3D-DIC) analyses demonstrating minimal subsurface skin deformation during detachment. Mechanical testing demonstrates up to ~99% reduction in adhesion energy upon activation, while maintaining stable load-bearing performance during use. 3D-DIC shows that the actuated SMP suppresses stress concentrations and minimizes subsurface skin deformation during detachment, unlike the dormant SMP. A kirigami structural design further enhances conformability on both singly and doubly curved anatomical surfaces while improving water vapor permeability. Finite element analysis and 3D-DIC measurements reveal substantial reductions in effective stiffness and enhanced bending accommodation enabled by the kirigami geometry. Integration with wireless mechano-acoustic sensors confirms reliable physiological signal acquisition in the dormant state and controlled detachment upon activation. This work establishes a thermally switchable SMP adhesive platform for low-force removal of skin-interfaced devices.
- 1 September 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1) , 10432
Open AccessShape memory polymer adhesives for on-demand, low-force detachment in skin-interfaced devices
Skin-interfaced biomedical devices require adhesives that provide strong attachment during use while enabling gentle removal with minimized subsurface skin deformation. Conventional medical adhesives lack mechanisms for on-demand adhesion modulation, often causing skin irritation and damage during detachment, particularly in vulnerable populations. Here, we present a thermally triggered shape memory polymer (SMP) adhesive that achieves reversible, high-contrast adhesion switching through programmable pyramidal structure recovery. The adhesive incorporates an array of pyramidal structures that remain flattened in a dormant state to ensure robust skin adhesion, but rapidly recover upon mild heating above the glass transition temperature, significantly reducing effective contact area and enabling low-force detachment. Adhesion switchability performances are supported by quantitative mechanical measurements, including reductions in peel force and adhesion energy after activation, as well as three-dimensional digital image correlation (3D-DIC) analyses demonstrating minimal subsurface skin deformation during detachment. Mechanical testing demonstrates up to ~99% reduction in adhesion energy upon activation, while maintaining stable load-bearing performance during use. 3D-DIC shows that the actuated SMP suppresses stress concentrations and minimizes subsurface skin deformation during detachment, unlike the dormant SMP. A kirigami structural design further enhances conformability on both singly and doubly curved anatomical surfaces while improving water vapor permeability. Finite element analysis and 3D-DIC measurements reveal substantial reductions in effective stiffness and enhanced bending accommodation enabled by the kirigami geometry. Integration with wireless mechano-acoustic sensors confirms reliable physiological signal acquisition in the dormant state and controlled detachment upon activation. This work establishes a thermally switchable SMP adhesive platform for low-force removal of skin-interfaced devices.
- Open Access
- 21 August 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (34)
Large-scale outdoor 3D trajectory measurements enabled by drone-assisted multicamera tracking
Accurate measurement of three-dimensional (3D) trajectories in outdoor environments is essential for studying complex dynamic processes such as atmospheric transport, aerial vehicle motion, and collective behavior. However, obtaining quantitative trajectory measurements over large outdoor volumes remains challenging because multicamera systems require reliable calibration and synchronization under field conditions. Here, we introduce a portable and automated drone-assisted multicamera 3D tracking (DAM3T) framework for georeferenced trajectory reconstruction. The system estimates multicamera extrinsic parameters from an autonomous drone flight without dedicated calibration markers and aligns the reconstructed coordinate system with geographic coordinates (WGS84) using real-time kinematic Global Positioning System (RTK-GPS) measurements. Validation under indoor motion-capture and outdoor RTK-GPS conditions demonstrates trajectory errors below 2%. We further demonstrate the framework through Lagrangian analysis using passive tracers, georeferenced tracking of multiple unmanned aerial vehicles, and 3D motion analysis in sports scenes. This establishes DAM3T as a scalable measurement platform that extends outdoor tracking from local-coordinate reconstruction to georeferenced measurement of complex dynamic systems.
- 21 August 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (34)
Open AccessLarge-scale outdoor 3D trajectory measurements enabled by drone-assisted multicamera tracking
Accurate measurement of three-dimensional (3D) trajectories in outdoor environments is essential for studying complex dynamic processes such as atmospheric transport, aerial vehicle motion, and collective behavior. However, obtaining quantitative trajectory measurements over large outdoor volumes remains challenging because multicamera systems require reliable calibration and synchronization under field conditions. Here, we introduce a portable and automated drone-assisted multicamera 3D tracking (DAM3T) framework for georeferenced trajectory reconstruction. The system estimates multicamera extrinsic parameters from an autonomous drone flight without dedicated calibration markers and aligns the reconstructed coordinate system with geographic coordinates (WGS84) using real-time kinematic Global Positioning System (RTK-GPS) measurements. Validation under indoor motion-capture and outdoor RTK-GPS conditions demonstrates trajectory errors below 2%. We further demonstrate the framework through Lagrangian analysis using passive tracers, georeferenced tracking of multiple unmanned aerial vehicles, and 3D motion analysis in sports scenes. This establishes DAM3T as a scalable measurement platform that extends outdoor tracking from local-coordinate reconstruction to georeferenced measurement of complex dynamic systems.
- Open Access
- 15 July 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (29) , eaeg2631
A wearable biomechanical system for medical evaluation of soft tissue disorders.
Evaluating soft tissue elasticity provides critical biomechanical insights essential for the precise characterization of various physiological and pathological conditions. Here, we present the clinical validation of a wireless, compact wearable system designed for direct, location-specific monitoring of the elastic modulus of the skin and underlying tissues via vibro-rotational biomechanical dynamics. Validated by computational models and experiments, the device uses a tunable skin interface to enable depth-controlled measurements across diverse anatomical sites. Two human subject studies, one involving patients with cancer-related lymphedema and the other involving patients with systemic scleroderma, yield data that correlate with standard clinical metrics. This technology offers the potential for longitudinal assessments in these and other contexts, in both clinical and home settings.
- 15 July 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (29) , eaeg2631
Open AccessA wearable biomechanical system for medical evaluation of soft tissue disorders.
Evaluating soft tissue elasticity provides critical biomechanical insights essential for the precise characterization of various physiological and pathological conditions. Here, we present the clinical validation of a wireless, compact wearable system designed for direct, location-specific monitoring of the elastic modulus of the skin and underlying tissues via vibro-rotational biomechanical dynamics. Validated by computational models and experiments, the device uses a tunable skin interface to enable depth-controlled measurements across diverse anatomical sites. Two human subject studies, one involving patients with cancer-related lymphedema and the other involving patients with systemic scleroderma, yield data that correlate with standard clinical metrics. This technology offers the potential for longitudinal assessments in these and other contexts, in both clinical and home settings.
- 1 June 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (6)
Eulerian and Lagrangian analysis of pulsatile jet vortices in a closed-circuit platform
Unidirectional pulsatile jets generated under continuous cyclic operation in closed-circuit mock circulatory platforms differ from open-circuit jets and synthetic-jet forcing in that backflow is suppressed by check valves and the suction phase is constrained, producing a finite net discharge each cycle while exhibiting a near-zero flow rate interval during part of the cycle. Here, we analyze how stroke ratio, forcing frequency, and working-fluid viscosity, together with the associated Reynolds-number variation, jointly shape near-field vortex dynamics and transport in such a system. Time-resolved particle image velocimetry was performed in the axial–radial plane of a submerged circular nozzle for stroke ratios L0/D0=2, 4, 6, and 8 and actuation frequencies of 60–100 BPM, using water and a 60 wt. % glycerol–water mixture. The velocity and vorticity fields were analyzed using time/phase averaging and snapshot proper orthogonal decomposition (POD) of in-plane velocity fluctuations, and Lagrangian transport boundaries were extracted from forward- and backward-time finite-time Lyapunov exponent (FTLE) fields. The near-field statistics show that the clearest working-fluid-dependent differences occur at low stroke ratio, where the evolution of shear-layer vorticity and downstream centerline metrics exhibit a stronger frequency dependence consistent with pulse-to-pulse interactions. POD reveals that the spatial organization of the dominant fluctuation modes depends on both working-fluid viscosity and stroke ratio. FTLE further reveals working-fluid and stroke-ratio-dependent differences in the formation and topology of transport boundaries, as transport ridges reorganize during successive-pulse interactions and provide connectivity information not readily inferred from vorticity alone. These results provide a combined Eulerian–Lagrangian characterization of continuously driven, closed-circuit unidirectional pulsatile jets relevant to mock circulatory applications.
- 1 June 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (6)
Eulerian and Lagrangian analysis of pulsatile jet vortices in a closed-circuit platform
Unidirectional pulsatile jets generated under continuous cyclic operation in closed-circuit mock circulatory platforms differ from open-circuit jets and synthetic-jet forcing in that backflow is suppressed by check valves and the suction phase is constrained, producing a finite net discharge each cycle while exhibiting a near-zero flow rate interval during part of the cycle. Here, we analyze how stroke ratio, forcing frequency, and working-fluid viscosity, together with the associated Reynolds-number variation, jointly shape near-field vortex dynamics and transport in such a system. Time-resolved particle image velocimetry was performed in the axial–radial plane of a submerged circular nozzle for stroke ratios L0/D0=2, 4, 6, and 8 and actuation frequencies of 60–100 BPM, using water and a 60 wt. % glycerol–water mixture. The velocity and vorticity fields were analyzed using time/phase averaging and snapshot proper orthogonal decomposition (POD) of in-plane velocity fluctuations, and Lagrangian transport boundaries were extracted from forward- and backward-time finite-time Lyapunov exponent (FTLE) fields. The near-field statistics show that the clearest working-fluid-dependent differences occur at low stroke ratio, where the evolution of shear-layer vorticity and downstream centerline metrics exhibit a stronger frequency dependence consistent with pulse-to-pulse interactions. POD reveals that the spatial organization of the dominant fluctuation modes depends on both working-fluid viscosity and stroke ratio. FTLE further reveals working-fluid and stroke-ratio-dependent differences in the formation and topology of transport boundaries, as transport ridges reorganize during successive-pulse interactions and provide connectivity information not readily inferred from vorticity alone. These results provide a combined Eulerian–Lagrangian characterization of continuously driven, closed-circuit unidirectional pulsatile jets relevant to mock circulatory applications.
- Open Access
- 28 April 2026
- Published by AIP Publishing in APL Engineering Physics
- Vol. 1 (2)
Physics of passive, bioinspired Lagrangian sensors for environmental monitoring
Passive sensors inspired by wind- and water-dispersed seeds offer a promising pathway toward biodegradable, large-scale environmental monitoring. Progress in this area relies on understanding seed dispersal physics, laboratory-based analyses to characterize and optimize individual sensor dynamics under controlled conditions, and field-scale imaging of an array of sensors to interpret atmospheric and environmental flows. Together, these approaches enable distributed, flow-following measurements across broad spatial domains and provide a physics-based framework for deciphering complex environmental phenomena.
- 28 April 2026
- Published by AIP Publishing in APL Engineering Physics
- Vol. 1 (2)
Open AccessPhysics of passive, bioinspired Lagrangian sensors for environmental monitoring
Passive sensors inspired by wind- and water-dispersed seeds offer a promising pathway toward biodegradable, large-scale environmental monitoring. Progress in this area relies on understanding seed dispersal physics, laboratory-based analyses to characterize and optimize individual sensor dynamics under controlled conditions, and field-scale imaging of an array of sensors to interpret atmospheric and environmental flows. Together, these approaches enable distributed, flow-following measurements across broad spatial domains and provide a physics-based framework for deciphering complex environmental phenomena.
- Open Access
- 1 March 2026
- Published by AIP Publishing in APL Engineering Physics
- Vol. 1 (1)
Full-field skin mechanics as a missing experimental layer in spatiotemporal haptics
Spatiotemporal haptic devices can now deliver distributed, multimodal touch across the body; however, their evaluation still relies predominantly on pointwise metrics and subjective user ratings. A critical experimental layer remains missing: full-field skin mechanics, which can systematically connect device actuation to perceptual outcomes.
- 1 March 2026
- Published by AIP Publishing in APL Engineering Physics
- Vol. 1 (1)
Open AccessFull-field skin mechanics as a missing experimental layer in spatiotemporal haptics
Spatiotemporal haptic devices can now deliver distributed, multimodal touch across the body; however, their evaluation still relies predominantly on pointwise metrics and subjective user ratings. A critical experimental layer remains missing: full-field skin mechanics, which can systematically connect device actuation to perceptual outcomes.
- Open Access
- 15 January 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1) , 601
Distributed multitudes of bio-inspired, biodegradable Lagrangian sensors for environmental sustainability
Bioresorbable distributed Lagrangian sensors may enable environmentally sustainable spatio-temporal mapping of acute disasters through integrated dynamic and chemical sensing. We summarize recent work in bioinspired, ultraminiature structures, sensing targets, wireless communication and power strategies, and conclude with emerging directions for advancing these sensing platforms. Biodegradable collections of Lagrangian sensors may enable sustainable mapping of environmental parameters. The authors evaluate bioinspired designs, sensing targets, communication methods, power supply strategies, and future directions for these platforms.
- 15 January 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1) , 601
Open AccessDistributed multitudes of bio-inspired, biodegradable Lagrangian sensors for environmental sustainability
Bioresorbable distributed Lagrangian sensors may enable environmentally sustainable spatio-temporal mapping of acute disasters through integrated dynamic and chemical sensing. We summarize recent work in bioinspired, ultraminiature structures, sensing targets, wireless communication and power strategies, and conclude with emerging directions for advancing these sensing platforms. Biodegradable collections of Lagrangian sensors may enable sustainable mapping of environmental parameters. The authors evaluate bioinspired designs, sensing targets, communication methods, power supply strategies, and future directions for these platforms.
- Open Access
- 1 December 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (12)
Experimental study of flow over a cylinder with rectangular ridges in the transitional subcritical regime
The wake flow modifications induced by variations in macroscopic rectangular ridge height on a cylinder surface were investigated experimentally using time-resolved particle image velocimetry. Experiments were conducted in a low-turbulence wind tunnel at Re=5760 in the transitional subcritical regime, with additional measurements at Re=1660 and 3900 performed for validation against reference data. Ridge height, expressed as the non-dimensional parameter h/D, was systematically varied across six cases (0–0.033). A broad range of flow diagnostics was employed, including velocity components, streamline patterns, phase-averaged fields, Reynolds stress distributions, vorticity contours, and power spectral density (PSD) analysis. The results show that increasing ridge height causes the wake vortex to form closer to the cylinder, enhances turbulence intensity, and shortens the effective shear layer. PSD analysis further reveals that larger ridge heights lead to lower Strouhal numbers and higher spectral amplitudes. These findings identify the macroscopic surface modulation as a key geometric parameter for wake manipulation, demonstrating that it can reproduce wake characteristics typically associated with higher Reynolds numbers, even when Re is fixed. This highlights new opportunities for passive and active flow control strategies in the transitional regime.
- 1 December 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (12)
Open AccessExperimental study of flow over a cylinder with rectangular ridges in the transitional subcritical regime
The wake flow modifications induced by variations in macroscopic rectangular ridge height on a cylinder surface were investigated experimentally using time-resolved particle image velocimetry. Experiments were conducted in a low-turbulence wind tunnel at Re=5760 in the transitional subcritical regime, with additional measurements at Re=1660 and 3900 performed for validation against reference data. Ridge height, expressed as the non-dimensional parameter h/D, was systematically varied across six cases (0–0.033). A broad range of flow diagnostics was employed, including velocity components, streamline patterns, phase-averaged fields, Reynolds stress distributions, vorticity contours, and power spectral density (PSD) analysis. The results show that increasing ridge height causes the wake vortex to form closer to the cylinder, enhances turbulence intensity, and shortens the effective shear layer. PSD analysis further reveals that larger ridge heights lead to lower Strouhal numbers and higher spectral amplitudes. These findings identify the macroscopic surface modulation as a key geometric parameter for wake manipulation, demonstrating that it can reproduce wake characteristics typically associated with higher Reynolds numbers, even when Re is fixed. This highlights new opportunities for passive and active flow control strategies in the transitional regime.
- Open Access
- 18 November 2025
- Published by Wiley in Advanced Intelligent Systems
- Vol. 7 (11)
Shape Morphing Programmable Systems for Enhanced Control in Low‐Velocity Flow Applications
- 18 November 2025
- Published by Wiley in Advanced Intelligent Systems
- Vol. 7 (11)
Open AccessShape Morphing Programmable Systems for Enhanced Control in Low‐Velocity Flow Applications
- Open Access
- 3 October 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (40) , eady6148
A wireless, implantable sensor for continuous monitoring of blood leakage after endovascular aneurysm repair
Endovascular aneurysm repair, a treatment for abdominal aortic aneurysms, carries the risk of recurrence due to endoleaks following stent graft implantation. Since these leaks do not present with specific symptoms, regular follow-up is necessary; however, now, only imaging-based monitoring is available. This study proposes an ultrathin flexible sensor inserted endovascularly with a stent to detect type I endoleaks, which pose the highest rupture risk. A coplanar capacitive sensor was attached to the stent graft using a specially developed flexible thermal adhesive to monitor blood leakage, without compromising the stent graft’s function. It seamlessly folds and unfolds with the stent, allowing implantation through catheter-based procedures. Experimental validation confirmed that the sensor does not induce blood leakage and demonstrated long-term stability and functionality under vascular and dynamic conditions. This technology enables wireless monitoring of endoleak status, facilitates timely intervention, and improves postoperative outcomes by reducing the risk of recurrent aneurysms.
- 3 October 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (40) , eady6148
Open AccessA wireless, implantable sensor for continuous monitoring of blood leakage after endovascular aneurysm repair
Endovascular aneurysm repair, a treatment for abdominal aortic aneurysms, carries the risk of recurrence due to endoleaks following stent graft implantation. Since these leaks do not present with specific symptoms, regular follow-up is necessary; however, now, only imaging-based monitoring is available. This study proposes an ultrathin flexible sensor inserted endovascularly with a stent to detect type I endoleaks, which pose the highest rupture risk. A coplanar capacitive sensor was attached to the stent graft using a specially developed flexible thermal adhesive to monitor blood leakage, without compromising the stent graft’s function. It seamlessly folds and unfolds with the stent, allowing implantation through catheter-based procedures. Experimental validation confirmed that the sensor does not induce blood leakage and demonstrated long-term stability and functionality under vascular and dynamic conditions. This technology enables wireless monitoring of endoleak status, facilitates timely intervention, and improves postoperative outcomes by reducing the risk of recurrent aneurysms.