A wireless, implantable sensor for continuous monitoring of blood leakage after endovascular aneurysm repair
Open Access
- 3 October 2025
- journal article
- materials science
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (40) , eady6148
Abstract
Endovascular aneurysm repair, a treatment for abdominal aortic aneurysms, carries the risk of recurrence due to endoleaks following stent graft implantation. Since these leaks do not present with specific symptoms, regular follow-up is necessary; however, now, only imaging-based monitoring is available. This study proposes an ultrathin flexible sensor inserted endovascularly with a stent to detect type I endoleaks, which pose the highest rupture risk. A coplanar capacitive sensor was attached to the stent graft using a specially developed flexible thermal adhesive to monitor blood leakage, without compromising the stent graft’s function. It seamlessly folds and unfolds with the stent, allowing implantation through catheter-based procedures. Experimental validation confirmed that the sensor does not induce blood leakage and demonstrated long-term stability and functionality under vascular and dynamic conditions. This technology enables wireless monitoring of endoleak status, facilitates timely intervention, and improves postoperative outcomes by reducing the risk of recurrent aneurysms.Keywords
This publication has 71 references indexed in Scilit:
- Thrombus on indwelling central venous catheters: The histopathology of “fibrin sheaths”CardioVascular and Interventional Radiology, 2000
- Type I and Type II Endoleaks: A More Useful Classification for Reporting Results of Endoluminal AAA RepairJournal of Endovascular Surgery, 1998
- Safety standards for stab-resistant body armour: a computer tomographic assessment of organ to skin distancesInjury, 1998
- Endoleak as a Complication of Endoluminal Grafting of Abdominal Aortic Aneurysms: Classification, Incidence, Diagnosis,and ManagementJournal of Endovascular Surgery, 1997
- “Endoleak”—A Proposed New Terminology to Describe Incomplete Aneurysm Exclusion by an Endoluminal GraftJournal of Endovascular Surgery, 1996
- Transfemoral Intraluminal Graft Implantation for Abdominal Aortic AneurysmsAnnals of Vascular Surgery, 1991
- Dielectric properties of gelatine phantoms used for simulations of biological tissues between 10 and 50 MHzInternational Journal of Hyperthermia, 1989
- Radio-Frequency Coils in Implantable Devices: Misalignment Analysis and Design ProcedureIEEE Transactions on Biomedical Engineering, 1987
- Blood pressure and heart rate variabilities in normotensive and hypertensive human beings.Circulation Research, 1983
- Design of radio-frequency powered coils for implant instrumentsMedical & Biological Engineering & Computing, 1977