LALachlan L. H. Andrew

Lachlan L. H. Andrew

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Lachlan L. H. Andrew has a total of 39 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • EMTR-Based Branch Identification for Accurate and Fast Fault Location

    by Gayanjali Pathirage, Cassidy Flynn, Reza Razzaghi, Lachlan Andrew

    Electromagnetic Time Reversal (EMTR) has been shown as a promising technique for fault localization in distribution networks. However, its application to larger networks is constrained by the need for finely spaced guessed fault points required in the back-propagation stage of the EMTR process. The need to assess numerous guessed locations can make the fault location process computationally expensive, and missing the matched fault point can lead to significant localization errors. This article proposes a novel EMTR-based method that pre-identifies the fault zone before pinpointing the fault location, by strategically placing guessed fault points solely at the network’s leaf nodes. Extensive simulations across networks of varying scales demonstrate that this approach substantially reduces the network search area while enhancing localization accuracy when the matched point is missed.

  • Supervisory control under delayed observations of events and states

    by Jiayuan Liang, Yanwei Zang, Wenbiao Zhang, Chaohui Gong, Lachlan L.H. Andrew, Hanran Zhang, Weilin Wang


  • Robust Fault Location Method for Topologically Complex Distribution Networks

    by Cassidy Flynn, Reza Razzaghi, Lachlan L. H. Andrew

    In recent years, electromagnetic time reversal techniques have emerged as a promising approach for locating faults in power networks. However, to date, these methods have typically considered relatively simple network topologies and low-impedance faults, which restricts their application. To overcome these limitations, this article proposes a novel fault location method using a new expression for the measured voltage, obtained by combining prefault and postfault systems into a unified system, which is applicable to more complex distribution network topologies. Extensive simulation studies are carried out using a topologically complex network that loosely represents a real medium voltage distribution network in Australia. The results show that the proposed method significantly outperforms prior methods in terms of fault location accuracy.


  • Topology Identification of Distribution Networks With Partial Smart Meter Coverage

    by Abu Bakr Pengwah, Yasin Zabihinia Gerdroodbari, Reza Razzaghi, Lachlan L. H. Andrew

    This paper presents a novel measurement-based approach for estimating the topology of low-voltage (LV) distribution networks containing different types of customer meters. The first type is smart meters that measure the voltage, and active and reactive power of customers with higher time resolution while the second type is energy meters (referred to as interval meters) that measure the net energy consumed by the customers at a lower time resolution. First, an optimization problem is proposed to estimate the network impedance models of distribution systems. A two-step topology estimation framework is then presented that first estimates the topology corresponding to the customers with smart meters and subsequently, identifies the location of the interval meters on the estimated topology. The performance of the proposed algorithms is evaluated on multiple randomly generated networks with different numbers of customers, and the IEEE European LV Test Feeder.


  • Model-Less Non-Technical Loss Detection Using Smart Meter Data

    by Abu Bakr Pengwah, Reza Razzaghi, Lachlan L. H. Andrew

    This paper proposes a novel method for estimating non-technical losses (NTL), typically due to electricity theft caused by bypassed meters in low-voltage distribution networks. First, the voltage sensitivity coefficients are estimated by a weighted least squares based approach using the residuals obtained from an ordinary least squares-based approach. Then, the voltage measurements of smart meters and the estimated sensitivity coefficients are used to estimate the actual consumption of customers. The differences between the measured and the estimated consumption values are compared against a threshold and customers whose differences exceed the threshold are flagged as fraudulent customers. The performance of the algorithm is evaluated on the IEEE European Low Voltage (LV) network in various case studies, and on large randomly generated distribution networks. The results exhibit the capability of the proposed algorithm in correctly identifying fraudulent meters, together with their actual consumption values.


  • An Improved Algorithm for Topology Identification of Distribution Networks Using Smart Meter Data and Its Application for Fault Detection

    by Cassidy Flynn, Abu Bakr Pengwah, Reza Razzaghi, Lachlan L. H. Andrew, David Flynn

    This paper proposes a new method for estimating the topology of radial distribution networks and a novel data-driven fault detection technique using smart meter data. An improved method to estimate voltage sensitivity coefficients from smart meter data is proposed that takes into account the variability of the transformer voltage. These coefficients are used in both the topology estimation and the fault detection algorithms. In the topology estimation algorithm, an improved graph learning algorithm, which iteratively constructs the network graph, is devised. In the fault detection algorithm, the objective is to look for sudden changes in the estimated voltage sensitivity coefficients. The performance of the proposed methods is first assessed on randomly generated topologies under various noise conditions. Then, the performance of the algorithms is validated using real smart meter measurements obtained from Australian distribution networks. The results show a significant improvement in the accuracy of estimated topologies compared to the state-of-the-art methods while the fault detection technique is successful in detecting faults using real smart meter data.


  • Size-Based Congestion Control Using Network Utility Maximization

    by Cao Wang, Lachlan L. H. Andrew, Bruno Luis Mendivez Vasquez, Hai L. Vu

    This paper presents a method for allocating transmission rates in a communication network that uses knowledge of the size of the file to be transmitted to seek to obtain the benefits of shortest remaining processing time (SRPT) scheduling. It provides fairness among file transmissions taking into account their sizes and the congestion on the links they use. The proposed approach is based on network utility maximisation (NUM), but with utility functions that vary in time depending on the remaining file size. A parameterized family of utility functions is proposed. For each value of the parameter, there is a threshold load such that an arbitrary network will be stable provided no link load exceeds that threshold. This is in contrast with SRPT, for which any non-zero load becomes unstable for topologies with sufficiently long paths. The method can be implemented by a distributed algorithm analogous to that of traditional NUM.


  • The Added Value of Coordinating Inverter Control

    by Peter Lusis, Lachlan L. H. Andrew, Ariel Liebman, Guido Tack

    Coordinated photovoltaic inverter control with centralized coordination of curtailment can increase the amount of energy sent from low-voltage (LV) distribution networks to the grid while respecting voltage constraints. First, this paper quantifies the improvement of such an approach relative to autonomous droop control, in terms of PV curtailment and line losses in balanced networks. It then extends the coordinated inverter control to unbalanced distribution networks. Finally, it formulates a control algorithm for different objectives such as the fairer distribution of PV curtailment and rewarding PV customers for utilizing the excess power locally. The coordinated inverter control algorithm is tested on the 114-node and 906-bus LV European test feeders with cable sizes between 50 mm and 240 mm and validated with reference to OpenDSS. The results demonstrate that coordinated inverter control is superior when applied to high impedance LV networks and LV networks constrained by the distribution transformer capacity limits compared to autonomous inverters. On the 95 mm overhead line, it yields a 2% increase on average in the utilized PV output with up to 5% increase for some PV locations at higher penetration levels. Up to a 20% increase in PV hosting capacity was observed for location scenarios with PV system clustering.


  • Open Access

    Reducing the Unfairness of Coordinated Inverter Dispatch in PV-Rich Distribution Networks

    by Peter Lusis, Lachlan L. H. Andrew, Shantanu Chakraborty, Ariel Liebman, Guido Tack

    The integration of a high share of solar photovoltaics (PV) in distribution networks requires advanced voltage control technologies or network augmentation, both associated with significant investment costs. An alternative is to prevent new customers from installing solar PV systems, but this is against the common goal of increasing renewable energy generation. This paper demonstrates that solar PV curtailment in low voltage areas can be reduced and fairly distributed among PV owners by centrally coordinating the operation of PV inverters. The optimal inverter active and reactive power operation points are computed by solving a multi-objective optimization problem with a fairness objective. The main results show that fair optimal inverter dispatch (FOID) results in less power curtailment than passive voltage regulation based on Volt/VAr droop control, especially at high solar PV to load ratios. The effectiveness of the model is demonstrated on a residential low voltage network.


  • Optimal sleeping: models and experiments for energy-delay tradeoff

    by Ioannis Kamitsos, Sangtae Ha, Lachlan L.H. Andrew, Jasika Bawa, Dana Butnariu, Hongseok Kim, Mung Chiang

    Multi-core architectures have supplanted single core schemes, in part because the maximum clock speed of a single core is limited by its energy consumption. They provide the additional, less exploited benefit of allowing a finer trade-ff between energy consumption and delay by turning off subsets of cores. We investigate how this tradeoff varies with the number of cores, and whether heterogeneity brings additional benefits to outweigh its increased complexity. We study optimal sleep policies in two settings: switching of homogeneous cores on a fast timescale, which models multiple cores in a CPU, and switching of heterogeneous cores on a slow timescale, which models different generation servers in a data centre. In the homogeneous-core case, we show the optimal policy is monotone hysteretic, and that the performance is less sensitive to load estimation errors. By implementing this policy on a real experimental testbed, we show that theory makes a good prediction of the resource pooling benefits, and extend our study to realistic bursty job arrivals and heavy-tailed job sizes. In the heterogeneous-core case, we provide a low complexity algorithm to find a combination of servers that have approximately the minimum power draw while providing a specified minimum processing speed.