Steve Bagley
Research Subjects
Steve Bagley has a total of 129 co-authors. Here are the top co-authors by number of shared publications:
- Alex Laude
Bioimaging Unit, Newcastle University, Newcastle upon Tyne, UK
4 shared publications - Miso Mitkovski
City Campus Light Microscopy Facility, Max Planck Institute for Multidisciplinary Sciences, Göttingen, Germany
4 shared publications - Roland Nitschke
Signalling Research Centres CIBSS and BIOSS, University of Freiburg, Freiburg, Germany
4 shared publications - Ulrike Boehm
Janelia Research Campus, Howard Hughes Medical Institute, Ashburn, USA
4 shared publications - Glyn Nelson
Bioimaging Unit, Newcastle University, Newcastle upon Tyne, UK
3 shared publications Laurent Gelman
Friedrich Miescher Institute for Biomedical Research, Basel, Switzerland
3 shared publications
Latest Publications
- Open Access
- 15 June 2026
- Published by Springer Nature in Nature Communications
Systematic discovery of UFM1 receptors reveals a regulatory module in DNA repair directing non-homologous end-joining
Posttranslational modifications with ubiquitin-like modifiers (UBLs) are critical for genome maintenance, yet many remain mechanistically uncharacterised. Here, we identify UFM1 as a key regulator of non-homologous end-joining (NHEJ), a major DNA double-strand break repair pathway. Using a structure-guided chemical biology approach, we develop a photo-crosslinkable UFM1 probe and, in combination with NMR, map non-canonical UFM1-binding interfaces in core NHEJ factors, including the disordered XRCC4 tail. Mechanistically, proximity-dependent proteomics and functional assays identify Ku70 as a crucial UFMylation substrate and reveal a UFM1-dependent axis in which XRCC4 engages UFMylated Ku70 to stabilise NHEJ complex assembly on chromatin. Disruption of this molecular mechanism via UFSP2 depletion or a hypomorphic UBA5 variant in patient-derived cells impairs NHEJ function, linking UFMylation defects to compromised genome integrity processes. Our findings define a complete UFM1 signalling module in DNA repair and establish a generalisable framework for dissecting low-affinity UBL networks with broad functional and disease relevance.
- 15 June 2026
- Published by Springer Nature in Nature Communications
Open AccessSystematic discovery of UFM1 receptors reveals a regulatory module in DNA repair directing non-homologous end-joining
Posttranslational modifications with ubiquitin-like modifiers (UBLs) are critical for genome maintenance, yet many remain mechanistically uncharacterised. Here, we identify UFM1 as a key regulator of non-homologous end-joining (NHEJ), a major DNA double-strand break repair pathway. Using a structure-guided chemical biology approach, we develop a photo-crosslinkable UFM1 probe and, in combination with NMR, map non-canonical UFM1-binding interfaces in core NHEJ factors, including the disordered XRCC4 tail. Mechanistically, proximity-dependent proteomics and functional assays identify Ku70 as a crucial UFMylation substrate and reveal a UFM1-dependent axis in which XRCC4 engages UFMylated Ku70 to stabilise NHEJ complex assembly on chromatin. Disruption of this molecular mechanism via UFSP2 depletion or a hypomorphic UBA5 variant in patient-derived cells impairs NHEJ function, linking UFMylation defects to compromised genome integrity processes. Our findings define a complete UFM1 signalling module in DNA repair and establish a generalisable framework for dissecting low-affinity UBL networks with broad functional and disease relevance.
- Open Access
- 19 January 2024
- Published by Springer Nature
Illumination Power, Stability, and Linearity Measurements for Confocal, Widefield and Multiphoton Microscopes v1
To obtain accurate, reproducible, and interpretable data when conducting imaging experiments, it is critical to consider external factors affecting data acquisition at various steps of the experimental workflow. Illumination power and stability represent two critical factors, especially when comparing fluorescence intensities between images during a time-lapse experiment or experiments performed at different times or on different microscopes. The fluorescence signal can be generated by different types of light sources. These light sources and their coupling elements (e.g., fibers) can display varying performances over time as they age, move, or as environmental conditions change. Unfortunately, microscope users can often only set illumination power as a percentage of its maximal output and may, therefore, not be aware of potential performance changes. It is important to recognize that a set percentage will not always yield the same illumination power in Watts at the objective over the course of an experiment, not to mention between days or systems. This means that selecting for example 10% output may lead to different experimental results over time or even between two microscopes of the same model. In addition to illumination stability, working within the linear range of the illumination power allows to adjust accurately the illumination power absolute value (in mW) using a fraction (or %) of its maximal value through the imaging software. If you are responsible for system maintenance, routinely measuring the illumination power, stability, and linearity over time can help you detect issues that affect the integrity of the system and thus the reproducibility of an experiment. This protocol describes how to measure the stability and linearity of the illumination power using calibrated external power sensors. This protocol is intended for confocal systems (raster scanning and spinning disks), Multi-photon systems (used for 2P- or 3P-imaging, SHG-imaging, etc.), and widefield systems. It represents the collective experience of over 50 imaging scientists.
- 19 January 2024
- Published by Springer Nature
Open AccessIllumination Power, Stability, and Linearity Measurements for Confocal, Widefield and Multiphoton Microscopes v1
To obtain accurate, reproducible, and interpretable data when conducting imaging experiments, it is critical to consider external factors affecting data acquisition at various steps of the experimental workflow. Illumination power and stability represent two critical factors, especially when comparing fluorescence intensities between images during a time-lapse experiment or experiments performed at different times or on different microscopes. The fluorescence signal can be generated by different types of light sources. These light sources and their coupling elements (e.g., fibers) can display varying performances over time as they age, move, or as environmental conditions change. Unfortunately, microscope users can often only set illumination power as a percentage of its maximal output and may, therefore, not be aware of potential performance changes. It is important to recognize that a set percentage will not always yield the same illumination power in Watts at the objective over the course of an experiment, not to mention between days or systems. This means that selecting for example 10% output may lead to different experimental results over time or even between two microscopes of the same model. In addition to illumination stability, working within the linear range of the illumination power allows to adjust accurately the illumination power absolute value (in mW) using a fraction (or %) of its maximal value through the imaging software. If you are responsible for system maintenance, routinely measuring the illumination power, stability, and linearity over time can help you detect issues that affect the integrity of the system and thus the reproducibility of an experiment. This protocol describes how to measure the stability and linearity of the illumination power using calibrated external power sensors. This protocol is intended for confocal systems (raster scanning and spinning disks), Multi-photon systems (used for 2P- or 3P-imaging, SHG-imaging, etc.), and widefield systems. It represents the collective experience of over 50 imaging scientists.
- 3 January 2022
- Published by Springer Nature in Nature Methods
- Vol. 19 (2) , 256
Author Correction: QUAREP-LiMi: a community endeavor to advance quality assessment and reproducibility in light microscopy
- 3 January 2022
- Published by Springer Nature in Nature Methods
- Vol. 19 (2) , 256
Author Correction: QUAREP-LiMi: a community endeavor to advance quality assessment and reproducibility in light microscopy
- Open Access
- 2 December 2021
- Published by Springer Nature in International Journal of Obesity
- Vol. 46 (3) , 605-612
The impact of obesity and bariatric surgery on the immune microenvironment of the endometrium
Background: The incidence of endometrial cancer is rising in parallel with the obesity epidemic. Obesity increases endometrial cancer risk and weight loss is protective, but the underlying mechanisms are incompletely understood. We hypothesise that the immune microenvironment may influence susceptibility to malignant transformation in the endometrium. The aim of this study was to measure the impact of obesity and weight loss on the immunological landscape of the endometrium. Methods: We conducted a prospective cohort study of women with class III obesity (body mass index, BMI ≥ 40 kg/m2) undergoing bariatric surgery or medically-supervised low-calorie diet. We collected blood and endometrial samples at baseline, and two and 12 months after weight loss intervention. Serum was analysed for inflammatory markers CRP, IL-6 and TNF-α. Multiplex immunofluorescence was used to simultaneously identify cells positive for immune markers CD68, CD56, CD3, CD8, FOXP3 and PD-1 in formalin-fixed paraffin-embedded endometrial tissue sections. Kruskal–Wallis tests were used to determine whether changes in inflammatory and immune biomarkers were associated with weight loss. Results: Forty-three women with matched serum and tissue samples at all three time points were included in the analysis. Their median age and BMI were 44 years and 52 kg/m2, respectively. Weight loss at 12 months was greater in women who received bariatric surgery (n = 37, median 63.3 kg) than low-calorie diet (n = 6, median 12.8 kg). There were significant reductions in serum CRP (p = 3.62 × 10−6, r = 0.570) and IL-6 (p = 0.0003, r = 0.459), but not TNF-α levels, with weight loss. Tissue immune cell densities were unchanged except for CD8+ cells, which increased significantly with weight loss (p = 0.0097, r = −0.323). Tissue CD3+ cell density correlated negatively with systemic IL-6 levels (p = 0.0376; r = −0.318). Conclusion: Weight loss is associated with reduced systemic inflammation and a recruitment of protective immune cell types to the endometrium, supporting the concept that immune surveillance may play a role in endometrial cancer prevention.
- 2 December 2021
- Published by Springer Nature in International Journal of Obesity
- Vol. 46 (3) , 605-612
Open AccessThe impact of obesity and bariatric surgery on the immune microenvironment of the endometrium
Background: The incidence of endometrial cancer is rising in parallel with the obesity epidemic. Obesity increases endometrial cancer risk and weight loss is protective, but the underlying mechanisms are incompletely understood. We hypothesise that the immune microenvironment may influence susceptibility to malignant transformation in the endometrium. The aim of this study was to measure the impact of obesity and weight loss on the immunological landscape of the endometrium. Methods: We conducted a prospective cohort study of women with class III obesity (body mass index, BMI ≥ 40 kg/m2) undergoing bariatric surgery or medically-supervised low-calorie diet. We collected blood and endometrial samples at baseline, and two and 12 months after weight loss intervention. Serum was analysed for inflammatory markers CRP, IL-6 and TNF-α. Multiplex immunofluorescence was used to simultaneously identify cells positive for immune markers CD68, CD56, CD3, CD8, FOXP3 and PD-1 in formalin-fixed paraffin-embedded endometrial tissue sections. Kruskal–Wallis tests were used to determine whether changes in inflammatory and immune biomarkers were associated with weight loss. Results: Forty-three women with matched serum and tissue samples at all three time points were included in the analysis. Their median age and BMI were 44 years and 52 kg/m2, respectively. Weight loss at 12 months was greater in women who received bariatric surgery (n = 37, median 63.3 kg) than low-calorie diet (n = 6, median 12.8 kg). There were significant reductions in serum CRP (p = 3.62 × 10−6, r = 0.570) and IL-6 (p = 0.0003, r = 0.459), but not TNF-α levels, with weight loss. Tissue immune cell densities were unchanged except for CD8+ cells, which increased significantly with weight loss (p = 0.0097, r = −0.323). Tissue CD3+ cell density correlated negatively with systemic IL-6 levels (p = 0.0376; r = −0.318). Conclusion: Weight loss is associated with reduced systemic inflammation and a recruitment of protective immune cell types to the endometrium, supporting the concept that immune surveillance may play a role in endometrial cancer prevention.
- Open Access
- 2 November 2021
- Published by Springer Nature
Illumination Power and illumination stability v1
To obtain accurate, reproducible, and interpretable data when conducting imaging experiments, it is critical to consider external factors affecting data acquisition at various steps of the experimental workflow. Illumination power and stability represent two critical factors, especially when comparing fluorescence intensities between images during a time-lapse experiment or experiments performed at different times or on other microscopes. The fluorescence signal can be generated by different types of light sources. These light sources and their coupling elements (e.g., fibers) can display varying performances over time as they age, move, or as environmental conditions change. Unfortunately, microscope users can often only set illumination power as a percentage of its maximal output and, may therefore, not be aware of potential performance changes. It is important to recognize that a set percentage will not always yield the same illumination power in Watts at the objective over the course of an experiment, not to mention between days or systems. This means that selecting for example 10% output may lead to different experimental results over time and will not necessarily be comparable to outputs obtained from other lasers or microscopes, even those of the very same model. If you are responsible for system maintenance, routinely measuring the illumination power, stability, and linearity over time can help you detect issues that affect the integrity of the system and thus the reproducibility of an experiment. This protocol describes how to measure the stability and linearity of the illumination power using calibrated external power sensors. This protocol is at the moment intended for confocal systems (raster scanning and spinning disks), but will be extended later to other imaging modalities. It represents the collective experience of 60 imaging scientists. Measurements made by our working group with this protocol are available in a public database, which will be updated with further contributions from the community.
- 2 November 2021
- Published by Springer Nature
Open AccessIllumination Power and illumination stability v1
To obtain accurate, reproducible, and interpretable data when conducting imaging experiments, it is critical to consider external factors affecting data acquisition at various steps of the experimental workflow. Illumination power and stability represent two critical factors, especially when comparing fluorescence intensities between images during a time-lapse experiment or experiments performed at different times or on other microscopes. The fluorescence signal can be generated by different types of light sources. These light sources and their coupling elements (e.g., fibers) can display varying performances over time as they age, move, or as environmental conditions change. Unfortunately, microscope users can often only set illumination power as a percentage of its maximal output and, may therefore, not be aware of potential performance changes. It is important to recognize that a set percentage will not always yield the same illumination power in Watts at the objective over the course of an experiment, not to mention between days or systems. This means that selecting for example 10% output may lead to different experimental results over time and will not necessarily be comparable to outputs obtained from other lasers or microscopes, even those of the very same model. If you are responsible for system maintenance, routinely measuring the illumination power, stability, and linearity over time can help you detect issues that affect the integrity of the system and thus the reproducibility of an experiment. This protocol describes how to measure the stability and linearity of the illumination power using calibrated external power sensors. This protocol is at the moment intended for confocal systems (raster scanning and spinning disks), but will be extended later to other imaging modalities. It represents the collective experience of 60 imaging scientists. Measurements made by our working group with this protocol are available in a public database, which will be updated with further contributions from the community.
- 21 May 2021
- Published by Springer Nature in Nature Methods
- Vol. 18 (12) , 1423-1426
QUAREP-LiMi: a community endeavor to advance quality assessment and reproducibility in light microscopy
The community-driven initiative Quality Assessment and Reproducibility for Instruments & Images in Light Microscopy (QUAREP-LiMi) wants to improve reproducibility for light microscopy image data through quality control (QC) management of instruments and images. It aims for a common set of QC guidelines for hardware calibration and image acquisition, management and analysis.
- 21 May 2021
- Published by Springer Nature in Nature Methods
- Vol. 18 (12) , 1423-1426
QUAREP-LiMi: a community endeavor to advance quality assessment and reproducibility in light microscopy
The community-driven initiative Quality Assessment and Reproducibility for Instruments & Images in Light Microscopy (QUAREP-LiMi) wants to improve reproducibility for light microscopy image data through quality control (QC) management of instruments and images. It aims for a common set of QC guidelines for hardware calibration and image acquisition, management and analysis.
- Open Access
- 3 May 2021
- Published by Springer Nature in Cancer Cell International
- Vol. 21 (1) , 1-15
iRFP (near-infrared fluorescent protein) imaging of subcutaneous and deep tissue tumours in mice highlights differences between imaging platforms
Background: In vivo imaging using fluorescence is used in cancer biology for the detection, measurement and monitoring of tumours. This can be achieved with the expression of fluorescent proteins such as iRFP, which emits light at a wavelength less attenuated in biological tissues compared to light emitted by other fluorescent proteins such as GFP or RFP. Imaging platforms capable of detecting fluorescent tumours in small animals have been developed but studies comparing the performance of these platforms are scarce. Results: Through access to three platforms from Xenogen, Bruker and Li-Cor, we compared their ability to detect iRFP-expressing subcutaneous tumours as well as tumours localised deeper within the body of female NSG mice. Each platform was paired with proprietary software for image analyse, but the output depends on subjective decisions from the user. To more objectively compare platforms, we developed an ‘in house’ software-based approach which results in lower measured variability between mice. Conclusions: Our comparisons showed that all three platforms allowed for reliable detection and monitoring of subcutaneous iRFP tumour growth. The biggest differences between platforms became apparent when imaging deeper tumours with the Li-Cor platform detecting most tumours and showing the highest dynamic range.
- 3 May 2021
- Published by Springer Nature in Cancer Cell International
- Vol. 21 (1) , 1-15
Open AccessiRFP (near-infrared fluorescent protein) imaging of subcutaneous and deep tissue tumours in mice highlights differences between imaging platforms
Background: In vivo imaging using fluorescence is used in cancer biology for the detection, measurement and monitoring of tumours. This can be achieved with the expression of fluorescent proteins such as iRFP, which emits light at a wavelength less attenuated in biological tissues compared to light emitted by other fluorescent proteins such as GFP or RFP. Imaging platforms capable of detecting fluorescent tumours in small animals have been developed but studies comparing the performance of these platforms are scarce. Results: Through access to three platforms from Xenogen, Bruker and Li-Cor, we compared their ability to detect iRFP-expressing subcutaneous tumours as well as tumours localised deeper within the body of female NSG mice. Each platform was paired with proprietary software for image analyse, but the output depends on subjective decisions from the user. To more objectively compare platforms, we developed an ‘in house’ software-based approach which results in lower measured variability between mice. Conclusions: Our comparisons showed that all three platforms allowed for reliable detection and monitoring of subcutaneous iRFP tumour growth. The biggest differences between platforms became apparent when imaging deeper tumours with the Li-Cor platform detecting most tumours and showing the highest dynamic range.