Gerardo Villa-Sánchez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Gerardo Villa-Sánchez has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
C Gutiérrez-Wing
Instituto Nacional de Investigaciones Nucleares, Carretera México-Toluca S/N La Marquesa, Ocoyoacac, Estado de México, CP 52750, Mexico
1 shared publication- Carlos Angeles Chávez
Instituto Mexicano del Petróleo
1 shared publication - Demetrio Mendoza-Anaya
Instituto Nacional de Investigaciones Nucleares
1 shared publication - Germán Escalante
Univ. Complutense
1 shared publication - Israel Vivaldo
Universidad Politécnica de Puebla (México)
1 shared publication - Noé Demesa
Tecnológico Nacional de México, Campus Pachuca, Pachuca, Mexico, Mexico
1 shared publication
Latest Publications
- Open Access
- 1 May 2021
- Published by AIP Publishing in AIP Advances
- Vol. 11 (5) , 055103
Correlation between Raman spectra and color of tungsten trioxide (WO3) thermally evaporated from a tungsten filament
The color exhibited by tungsten trioxide (WO3) can be associated with both its stoichiometry and crystallinity. Correlation between the color exhibited by WO3 powders and their purity and crystalline properties is reported in this paper. The WO3 powders were deposited by evaporation of tungsten trioxide from the surface of a tungsten filament. The WO3 powders exhibited three different shades of blue: navy, royal, and sky. The color of the WO3 powders changed to white after thermal treatment at 500 °C for 30 min in an ambient atmosphere. Raman analyses showed that transition from amorphous to crystalline WO3 started when the powders exhibited navy-blue color and ended when WO3 powders exhibited a white color. Scanning electron microscopy analysis showed particle agglomeration characteristics in all WO3 powders, even after they were thermally treated. The mechanism of deposition of WO3 from the tungsten filament was suggested to be governed by thermal evaporation of tungsten trioxide from the surface of the oxidized tungsten filament.
- 1 May 2021
- Published by AIP Publishing in AIP Advances
- Vol. 11 (5) , 055103
Open AccessCorrelation between Raman spectra and color of tungsten trioxide (WO3) thermally evaporated from a tungsten filament
The color exhibited by tungsten trioxide (WO3) can be associated with both its stoichiometry and crystallinity. Correlation between the color exhibited by WO3 powders and their purity and crystalline properties is reported in this paper. The WO3 powders were deposited by evaporation of tungsten trioxide from the surface of a tungsten filament. The WO3 powders exhibited three different shades of blue: navy, royal, and sky. The color of the WO3 powders changed to white after thermal treatment at 500 °C for 30 min in an ambient atmosphere. Raman analyses showed that transition from amorphous to crystalline WO3 started when the powders exhibited navy-blue color and ended when WO3 powders exhibited a white color. Scanning electron microscopy analysis showed particle agglomeration characteristics in all WO3 powders, even after they were thermally treated. The mechanism of deposition of WO3 from the tungsten filament was suggested to be governed by thermal evaporation of tungsten trioxide from the surface of the oxidized tungsten filament.
- 5 June 2007
- Published by IOP Publishing in Nanotechnology
- Vol. 18 (26) , 265703
Ag nanoparticle effects on the thermoluminescent properties of monoclinic ZrO2exposed to ultraviolet and gamma radiation
The goal of this work was to analyse ZrO(2) in the pure state and when doped with Ag nanoparticles, by electron microscopy, x-ray diffraction and thermoluminescence methods. According to the results obtained, Ag nanoparticles did not modify the morphology or the crystalline structure of the ZrO(2). The thermoluminescent (TL) response of pure ZrO(2) showed two peaks, one at 334 K and the other at 417 K, when it was exposed to ultraviolet (UV) radiation, and at 342 and 397 K when gamma radiation was used. For ZrO(2) impregnated with Ag nanoparticles a diminished TL intensity due to nanoparticle shielding was observed, but the glow curve shape was similar. However, when Ag nanoparticles were added during the ZrO(2) synthesis, a shift of the TL peaks towards higher temperature values with reference to pure ZrO(2) was observed. A linear dependence of the integrated TL signal as a function of the irradiation dose was observed in all analysed samples. It was possible to determine some kinetic parameters, such as activation energy, kinetic order and frequency factor, using the sequential quadratic programming glow curve deconvolution; it was found that these values are highly dependent on the type of radiation used. Ag nanoparticles present in ZrO(2) also modified the kinetic parameters, mainly when they were added during the synthesis of ZrO(2). Our results reinforce the possibilities of using pure and doped ZrO(2) as an appropriate dosimetric material in radiation physics.
- 5 June 2007
- Published by IOP Publishing in Nanotechnology
- Vol. 18 (26) , 265703
Ag nanoparticle effects on the thermoluminescent properties of monoclinic ZrO2exposed to ultraviolet and gamma radiation
The goal of this work was to analyse ZrO(2) in the pure state and when doped with Ag nanoparticles, by electron microscopy, x-ray diffraction and thermoluminescence methods. According to the results obtained, Ag nanoparticles did not modify the morphology or the crystalline structure of the ZrO(2). The thermoluminescent (TL) response of pure ZrO(2) showed two peaks, one at 334 K and the other at 417 K, when it was exposed to ultraviolet (UV) radiation, and at 342 and 397 K when gamma radiation was used. For ZrO(2) impregnated with Ag nanoparticles a diminished TL intensity due to nanoparticle shielding was observed, but the glow curve shape was similar. However, when Ag nanoparticles were added during the ZrO(2) synthesis, a shift of the TL peaks towards higher temperature values with reference to pure ZrO(2) was observed. A linear dependence of the integrated TL signal as a function of the irradiation dose was observed in all analysed samples. It was possible to determine some kinetic parameters, such as activation energy, kinetic order and frequency factor, using the sequential quadratic programming glow curve deconvolution; it was found that these values are highly dependent on the type of radiation used. Ag nanoparticles present in ZrO(2) also modified the kinetic parameters, mainly when they were added during the synthesis of ZrO(2). Our results reinforce the possibilities of using pure and doped ZrO(2) as an appropriate dosimetric material in radiation physics.