Qiang Tang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Qiang Tang has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Shenli Jia
College of Electrical Engineering, Sichuan University 1 , Chengdu 610065
3 shared publications - Akiko Kumada
The University of Tokyo
1 shared publication Haibo Su
Test and Research Institute of Guangzhou Power Supply Company Ltd. Guangzhou China
1 shared publication- Masahiro Sato
The University of Tokyo
1 shared publication Shixin Xiu
Department of Electrical Engineering Xi'an Jiaotong University China
1 shared publicationWenxiong Mo
Test and Research Institute of Guangzhou Power Supply Company Ltd. Guangzhou China
1 shared publication
Latest Publications
- 25 September 2024
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 57 (50) , 505204
Optical diagnostics of vacuum arcs in the process of DC interruption
Vacuum circuit-breakers (VCBs) are commonly used in emerging mechanical DC circuit-breakers. The electrical performance of VCBs in DC interruption duties has been extensively investigated, but basic physics such as the excitation temperature of plasma species, electron/vapor densities and emission of droplets in such applications were rarely reported. In this paper, we focus on how the short high frequency (HF) current pulse affects erosion of electrodes as well as generation of flying droplets by using laser shadow photography. Spectroscopy was adopted to obtain spectra and calculate the excitation temperature of CuI. Shack–Hartmann wavefront sensors were applied to measure neutral and electron density, in tests where di/dt, breaking current and the direction of the injected HF current varied. Indeed, the in-phase injection of the HF current caused an intense arc, but the pulse was too short to make either the cathode or anode melt. Since the plasma is in a nonequilibrium state, the excitation temperature of CuI is relatively low. Electron densities in different tests all approach similar values right before current zero. Neutral densities show strong fluctuation and independence on instantaneous current.
- 25 September 2024
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 57 (50) , 505204
Optical diagnostics of vacuum arcs in the process of DC interruption
Vacuum circuit-breakers (VCBs) are commonly used in emerging mechanical DC circuit-breakers. The electrical performance of VCBs in DC interruption duties has been extensively investigated, but basic physics such as the excitation temperature of plasma species, electron/vapor densities and emission of droplets in such applications were rarely reported. In this paper, we focus on how the short high frequency (HF) current pulse affects erosion of electrodes as well as generation of flying droplets by using laser shadow photography. Spectroscopy was adopted to obtain spectra and calculate the excitation temperature of CuI. Shack–Hartmann wavefront sensors were applied to measure neutral and electron density, in tests where di/dt, breaking current and the direction of the injected HF current varied. Indeed, the in-phase injection of the HF current caused an intense arc, but the pulse was too short to make either the cathode or anode melt. Since the plasma is in a nonequilibrium state, the excitation temperature of CuI is relatively low. Electron densities in different tests all approach similar values right before current zero. Neutral densities show strong fluctuation and independence on instantaneous current.
- Open Access
- 4 May 2021
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 6 (6) , 997-1008
Analysis of influence of a novel inductive fault current limiter on the circuit breaker in 500 kV power system
A contribution to the engineering application of a proposed 500 kV fault current limiter (FCL) is presented. A new type of FCL composed of a highly coupled split reactor (HCSR) and fast switches is proposed. When the circuit breaker (CB) in series with the FCL in the 500 kV power system interrupts the limited fault current, the rate of rise of the recovery voltage (RRRV) reaches a value much higher than the rated value. Based on a simplified equivalent single‐phase circuit, the influence of the new FCL on the interruption procedure of the CB is simulated and discussed. The simulation results show that the high RRRV is caused by high‐frequency resonant oscillations between the HCSR and its parasite capacitance. Analysis indicates that when the reactance of the FCL is close to the short circuit reactance of the system, the RRRV will reach the highest value. To solve this issue, we proposed installing a shunt capacitor with the FCL. Simulation results showed that the RRRV under all fault modes could be restrained to below the rated value by introducing a certain shunt capacitor.
- 4 May 2021
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 6 (6) , 997-1008
Open AccessAnalysis of influence of a novel inductive fault current limiter on the circuit breaker in 500 kV power system
A contribution to the engineering application of a proposed 500 kV fault current limiter (FCL) is presented. A new type of FCL composed of a highly coupled split reactor (HCSR) and fast switches is proposed. When the circuit breaker (CB) in series with the FCL in the 500 kV power system interrupts the limited fault current, the rate of rise of the recovery voltage (RRRV) reaches a value much higher than the rated value. Based on a simplified equivalent single‐phase circuit, the influence of the new FCL on the interruption procedure of the CB is simulated and discussed. The simulation results show that the high RRRV is caused by high‐frequency resonant oscillations between the HCSR and its parasite capacitance. Analysis indicates that when the reactance of the FCL is close to the short circuit reactance of the system, the RRRV will reach the highest value. To solve this issue, we proposed installing a shunt capacitor with the FCL. Simulation results showed that the RRRV under all fault modes could be restrained to below the rated value by introducing a certain shunt capacitor.
- Open Access
- 1 May 2021
- Published by AIP Publishing in AIP Advances
- Vol. 11 (5) , 055218
Experimental investigations on the post-arc current of the vacuum circuit breaker in an active mechanical DC circuit breaker
Vacuum circuit breakers (VCB) are commonly used in active mechanical direct current circuit breakers (DC CBs) to accomplish the interruption of the fault current. The post-arc current phenomenon of a VCB is related to the dielectric recovery process of the VCB. Thus, we performed experiments to investigate the influence on the post-arc current by taking the electrode separation, breaking current, and interruption of the bi-directional current with the injecting high frequency current in a fixed direction into account. To be in accordance with the practical interruption duty, the breaking current in the experiment ranges from 500 A to 20 kA. At the same time, the di/dt at current zero (CZ) varies between 200 and 1100 A/μs. The experiment results reveal that the peak value of the post-arc current in an active DC circuit breaker can reach more than 100 A with high di/dt at CZ. It is found that with a longer electrode separation, not only the residual charge increases but also the post-arc current increases. The arcing current before CZ can influence the post-arc current but the effective duration before CZ is short. This duration is the memory time and it is derived from the experiment results. The influence of the breaking current and interruption of the bi-directional current with the injecting current in a fixed direction are dependent on the relation of the current commutation time with the memory time.
- 1 May 2021
- Published by AIP Publishing in AIP Advances
- Vol. 11 (5) , 055218
Open AccessExperimental investigations on the post-arc current of the vacuum circuit breaker in an active mechanical DC circuit breaker
Vacuum circuit breakers (VCB) are commonly used in active mechanical direct current circuit breakers (DC CBs) to accomplish the interruption of the fault current. The post-arc current phenomenon of a VCB is related to the dielectric recovery process of the VCB. Thus, we performed experiments to investigate the influence on the post-arc current by taking the electrode separation, breaking current, and interruption of the bi-directional current with the injecting high frequency current in a fixed direction into account. To be in accordance with the practical interruption duty, the breaking current in the experiment ranges from 500 A to 20 kA. At the same time, the di/dt at current zero (CZ) varies between 200 and 1100 A/μs. The experiment results reveal that the peak value of the post-arc current in an active DC circuit breaker can reach more than 100 A with high di/dt at CZ. It is found that with a longer electrode separation, not only the residual charge increases but also the post-arc current increases. The arcing current before CZ can influence the post-arc current but the effective duration before CZ is short. This duration is the memory time and it is derived from the experiment results. The influence of the breaking current and interruption of the bi-directional current with the injecting current in a fixed direction are dependent on the relation of the current commutation time with the memory time.