MTMartin P. Tornai

Martin P. Tornai

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Martin P. Tornai has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Special Section Guest Editorial: Introduction to the JMI Special Issue on Advances in Breast Imaging

    by Hilde Bosmans, Robert Marti, Nicholas Marshall, Martin Tornai, Reyer Zwiggelaer, Alistair Mackenzie

    The editorial introduces the JMI Special Issue on Advances in Breast Imaging.

  • Performance comparison of a dedicated total breast PET system with a clinical whole-body PET system: a simulation study

    by Suranjana Samanta, Jianyong Jiang, Mahdjoub Hamdi, Alan Z Register, Stanislaw Majewski, Mark B Williams, Timothy G Turkington, Martin P Tornai, Richard Laforest, Joseph A O’SUllivan, et al.

    This paper presents a novel PET geometry for breast cancer imaging. The scanner consists of a ‘stadium’ (a rectangle with two semi-circles on opposite sides) shaped ring, along with anterior and posterior panels to provide high sensitivity and high spatial resolution for an imaging field-of-view (FOV) that include both breasts, mediastinum and axilla. We simulated this total-breast PET system using GATE and reconstructed the coincidence events using a GPU-based list-mode image reconstruction implementing maximum likelihood expectation-maximization (ML-EM) algorithm. The rear-panel is made up of a single layer of LSO crystals (3.2 × 3.2 × 20 mm 3 each), while the ‘stadium’-shaped elongated ring and the anterior panel are made with dual-layered LSO crystals (1.6 × 1.6 × 6 mm 3 each). The energy resolution and coincidence resolving time of all detectors are assumed to be 12% and 250 ps full-width-at-half-maximum, respectively. Various sized simulated lesions (4, 5, 6 mm) having 4:1, 5:1, and 6:1 lesion-to-background radioactivity concentration ratios, mimicking different biological uptakes, were strategically located throughout a volumetric torso phantom. We compared system sensitivity and lesion detectability of the dedicated total-breast PET system to a state-of-the-art clinical whole-body PET scanner. The mean sensitivity of the total-breast PET system is 3.21 times greater than that of a whole-body PET scanner in the breast regions. The total-breast PET system also provides better contrast-recovery coefficients for lesions of all sizes and lesion-to-background ratios in the breast when compared to a reference clinical whole-body PET scanner. Receiver operating characteristics (ROC) study shows the area under the ROC curve is 0.948 and 0.924 for the total-breast system and the whole-body PET scanner, respectively, in the detection of 4 mm diameter lesions with 4:1 lesion-to-background ratio. This study demonstrates our novel geometry can provide an imaging FOV larger than conventional PEM systems to simultaneously image both breasts, chest wall and axillae with significantly improved lesion detectability in the breasts when compared to a whole-body PET scanner.


  • Open Access

    Special Section Guest Editorial: Advances in Breast Imaging

    by Elizabeth A. Krupinski, Sue Astley, Robert Marti, Martin P. Tornai, Reyer Zwiggelaar

    This guest editorial introduces the special section on Advances in Breast Imaging. Breast cancer is the most common cancer in women, irrespective of race or ethnicity. It is the most common cause of cancer related deaths among Hispanic women in the United States and second most common for white, Black, Asian/Pacific Islander and American Indian/Alaska Native women.1 Similar statistics are observed worldwide.2 The International Workshop on Breast Imaging (IWBI), held July 8–11, 2018, in Atlanta, Georgia, was the 14th in a series of workshops/conferences originally named the International Workshop on Digital Mammography (IWDM until 2016), targeting novel breast imaging methods. Until 2012, there was a strong focus on digital techniques in mammography. At that time, digital breast tomosynthesis (DBT) was taking center stage, hence the conference name was changed to the International Workshop on Breast Imaging (IWBI). Today the meeting incorporates an even broader scope reflecting the significant advances being made in breast imaging including instrumentation approaches (e.g., MRI, ultrasound, molecular breast imaging with single photon and PET), computer algorithmic approaches (e.g., modeling, simulation, artificial intelligence, deep learning), and biomarker based technologies (e.g., molecular probes, software based methods). Increasingly, combinations of these approaches cross disciplinary borders just as radiology, pathology, oncology and surgery to diagnose and treat patients in a more holistic manner. The special nature of IWBI is the gathering of disciplines that usually do not meet at the same time – medicine, psychology, physics, and engineering – meeting to address advancing imaging technologies in breast cancer detection and treatment. Researchers in these disciplines do not typically gather at larger imaging conferences. IWBI is the major forum for achieving interdisciplinary interaction. There are other breast cancer focused meetings, but IWBI is the only long-standing meeting completely dedicated to bringing together a diverse group of researchers, clinicians, and industry representatives jointly committed to developing, validating, and translating technology (e.g., imaging hardware, image analysis tools, computer-aided decision support systems) for early detection and subsequent patient management of breast cancer. IWBI 2018 covered a wide spectrum of traditional and “hot” emerging topic areas related to breast cancer, ranging from technology development and basic science applications, to translational and clinical implementation assessments and patient outcomes. In addition to three keynote speakers and two highly interactive poster sessions, there were nine presentation sessions: Screening & Clinical Interpretation, Deep Learning: Lesion Detection & Classification, Breast Density, Intersection of Clinical Imaging Sources, Image Quality: Dose & Motion, Novel Imaging Technology, Imaging Phantoms, Image Analysis & Computer-Aided Techniques, and Simulation & Virtual Clinical Trials. Presenters at the meeting were invited to submit their work to this Journal of Medical Imaging special section and nine papers were accepted spanning a variety of important and interesting topics. Brombal et al. report on their first in vivo synchrotron radiation (SR) breast computed tomography (BCT) development program that capitalizes on the high spatial coherence of SR and phase-contrast (PhC) imaging. The program is in its early stages and this paper reports on high-resolution BCT acquisitions of breast specimens, and shows that by applying the phase-retrieval algorithm a five-time CNR increase can be obtained with a minor loss in spatial resolution across soft tissue interfaces. Also on the more technical side, Scarparo et al. provide a method for denoising DBT to adhere better to the “as low as reasonably achievable” (ALARA) principle for minimizing radiation dose. They propose and evaluate a double denoising approach that filters in both projection (pre-reconstruction) and image (post-reconstruction) domains, showing that double filtering is not superior to filtering in the projection domain only. They suggest that the noise model in the DBT image domain may be better modeled by a Burr distribution than a Gaussian distribution. Also related to DBT and improving quality is the paper by Rose et al. in which they investigate fiber-like features and how image reconstruction can affect their appearance. They considered the impact of reconstruction algorithm and regularization strength on the conspicuity of fiber-like signals of various orientations in a simulation. They found that at low regularization setting, there was significant variation in conspicuity as a function of orientation in the viewing plane, with the conspicuity of fibers nearly aligned with the plane of the x-ray source trajectory being decreased relative to more obliquely oriented fibers. Additionally, increasing regularization strength mitigates this orientation dependence at the cost of increasing depth blur of these structures. Deep learning, as at many conferences today, was also a very hot topic at IWBI. In this issue we have three deep learning related papers. Ionescu et al. built a convolutional neural network (CNN) to predict visual analog scale (VAS) density scores from full-field digital mammograms (FFDM). They used contralateral mammograms of screen detected cancers and prior images of women with cancers detected subsequently, matched to controls on age, menopausal status, parity, HRT and BMI to evaluate performance on breast cancer prediction. There was no significant difference between reader VAS and predicted VAS for the prior test set, indicating that their fully automated method shows promising results for cancer risk prediction comparable to human performance. Automatic mass detection was the focus of CNN method used by Agarwal et al. They used a patch-based CNN method and also investigated the use of transfer learning. They evaluated three CNNs and found that InceptionV3 performed best for classifying the mass and non-mass breast regions. They also showed the benefit of domain adaptation between the CBIS-DDSM (digitized) and INbreast (digital) datasets using the InceptionV3 CNN. In a slightly different vein, Whitney et al. looked at the effect of biopsy on MRI radiomics for diagnosis and prognosis of breast cancer, noting that a challenge is the fact that the appearance of lesions on images may be affected by biopsy. The distributions for most non-size features for each lesion type, however, failed to show significant differences between biopsy conditions. Fourteen features outperformed random guessing in classification. The remaining papers cover a variety of important topics, but all touched upon image quality and observer performance to some extent. Salkowski et al. compared technical recalls between DBT and FFDM looking at imaging modality (FFDM, DBT + FFDM, DBT + synthesized mammography (SynM)), images requested, and indications. Only 0.57% of cases in the study were recalled for indications or repeated views. DBT had significantly less recalls compared to FFDM, with: 27.2% for motion, 53.3% for positioning, and 19.4% for technique/artifacts. There were significant differences prior to and after implementing DBT + SynM. Technical recalls declined significantly with the inclusion of DBT (SynM/FFDM) compared to FFDM alone. Recalls for motion demonstrated the greatest decrease. Positioning was a dominant factor overall regardless of modality. They contend that continued technologist education in positioning could decrease technical recalls. Fieselmann et al. assessed a commercial software application for fast onsite quantification of volumetric breast density using breast tissue equivalent phantom experiments resulting in a mean absolute error of 3.84%. Reproducibility of measurement resulted in Pearson correlation coefficients higher than 0.90 for a variety of comparisons. Agreement between breast density categories computed by the software with those determined by 32 radiologists was good with 69.5% for FFDM and 64.6% for DBT. Finally, Huang et al. compared contrast-enhanced digital mammography (CEDM) and contrast-enhanced DBT (CEDBT) for lesion assessment. Two radiologists assessed CEDM and CEDBT patient images (BIRADS 4 or 5) side-by-side and compared contrast enhancement of lesions and lesion margins. CEDBT provided better lesion margins than CEDM with limited reduction in contrast enhancement with less radiation dose than CEDM + DBT. We hope that the papers compiled here from the 2018 IWBI meeting provide readers with an overview of some of the exciting and important areas of research being investigated by researchers around the world to improve the detection, diagnosis, and treatment of breast cancer patients, to improve outcomes and quality of life. We also hope to spark more interest in multi-disciplinary, team-science-based breast cancer imaging research that will lead to new technologies and techniques to help eradicate this deadly disease. References 1. Centers for Disease Control and Prevention, “Breast cancer statistics,” (2019) https://www.cdc.gov/cancer/breast/statistics/index.htm March ). 2019). Google Scholar 2. World Health Organization, “Breast cancer: prevention and control,” (2019) https://www.who.int/cancer/detection/breastcancer/en/index1.html March ). 2019). Google Scholar

  • Implementation and CT sampling characterization of a third-generation SPECT–CT system for dedicated breast imaging

    by Jainil P. Shah, Steve D. Mann, Randolph L. McKinley, Martin P. Tornai

    Stand-alone cone beam computed tomography (CT) and single-photon emission computed tomography (SPECT) systems capable of complex acquisition trajectories have previously been developed for breast imaging. Fully three-dimensional (3-D) motions of SPECT systems provide views into the chest wall and throughout the entire volume. The polar tilting capability of the CBCT system has shown improvement in sampling close to the chest wall, while eliminating cone beam artifacts. Here, a single hybrid SPECT–CT system, with each individual modality capable of independently traversing complex trajectories around a common pendant breast volume, was developed. We present the practical implementation of this design and preliminary results of the CT system. The fully 3-D SPECT was nested inside the suspended CT gantry and oriented perpendicular to the CT source–detector pair. Both subsystems were positioned on a rotation stage, with the combined polar and azimuthal motions enabling spherical trajectories. Six trajectories were used for initial evaluation of the tilt capable CT system. The developed system can achieve polar tilt angles with a <0.02-deg positioning error and no hysteresis. Initial imaging results demonstrate that additional off-axis projection views of various geometric resolution phantoms facilitate more complete sampling, more consistent attenuation value recovery, and markedly improved reconstructions. This system could have various applications in diagnostic or therapeutic breast imaging.


  • Open Access

    Three dimensional dose distribution comparison of simple and complex acquisition trajectories in dedicated breast CT

    by Jainil P. Shah, Steve D. Mann, Randolph L. McKinley, Martin P. Tornai

    Purpose: A novel breast CT system capable of arbitrary 3D trajectories has been developed to address cone beam sampling insufficiency as well as to image further into the patient's chest wall. The purpose of this study was to characterize any trajectory‐related differences in 3D x‐ray dose distribution in a pendant target when imaged with different orbits.Methods: Two acquisition trajectories were evaluated: circular azimuthal (no‐tilt) and sinusoidal (saddle) orbit with ±15° tilts around a pendant breast, using Monte Carlo simulations as well as physical measurements. Simulations were performed with tungsten (W) filtration of a W‐anode source; the simulated source flux was normalized to the measured exposure of a W‐anode source. A water‐filled cylindrical phantom was divided into 1 cm3 voxels, and the cumulative energy deposited was tracked in each voxel. Energy deposited per voxel was converted to dose, yielding the 3D distributed dose volumes. Additionally, three cylindrical phantoms of different diameters (10, 12.5, and 15 cm) and an anthropomorphic breast phantom, initially filled with water (mimicking pure fibroglandular tissue) and then with a 75% methanol‐25% water mixture (mimicking 50–50 fibroglandular‐adipose tissues), were used to simulate the pendant breast geometry and scanned on the physical system. Ionization chamber calibrated radiochromic film was used to determine the dose delivered in a 2D plane through the center of the volume for a fully 3D CT scan using the different orbits.Results: Measured experimental results for the same exposure indicated that the mean dose measured throughout the central slice for different diameters ranged from 3.93 to 5.28 mGy, with the lowest average dose measured on the largest cylinder with water mimicking a homogeneously fibroglandular breast. These results align well with the cylinder phantom Monte Carlo studies which also showed a marginal difference in dose delivered by a saddle trajectory in the central slice. Regardless of phantom material or filled fluid density, dose delivered by the saddle scan was negligibly different than the simple circular, no‐tilt scans. The average dose measured in the breast phantom was marginally higher for saddle than the circular no tilt scan at 3.82 and 3.87 mGy, respectively.Conclusions: Not only does nontraditional 3D‐trajectory CT scanning yield more complete sampling of the breast volume but also has comparable dose deposition throughout the breast and anterior chest volume, as verified by Monte Carlo simulation and physical measurements.


  • Characterization of simulated incident scatter and the impact on quantification in dedicated breast single-photon emission computed tomography

    by Steve D. Mann, Martin P. Tornai

    The objective was to characterize the changes seen from incident Monte Carlo-based scatter distributions in dedicated three-dimensional (3-D) breast single-photon emission computed tomography, with emphasis on the impact of scatter correction using the dual-energy window (DEW) method. Changes in scatter distributions with 3-D detector position were investigated for prone breast imaging with an ideal detector. Energy spectra within a high-energy scatter window measured from simulations were linearly fit, and the slope was used to characterize scatter distributions. The impact of detector position on the measured scatter fraction within various photopeak windows and the k value (ratio of scatter within the photopeak and scatter energy windows) useful for scatter correction was determined. Results indicate that application of a single k value with the DEW method in the presence of anisotropic object scatter distribution is not appropriate for trajectories including the heart and liver. The scatter spectra’s slope demonstrates a strong correlation to measured k values. Reconstructions of fixed-tilt 3-D acquisition trajectories with a single k value show quantification errors up to 5% compared to primary-only reconstructions. However, a variable-tilt trajectory provides improved sampling and minimizes quantification errors, and thus allows for a single k value to be used with the DEW method leading to more accurate quantification.


  • Open Access

    The Spectrum of Medical Imaging in the 2015 International Year of Light

    by Maryellen L. Giger, Martin P. Tornai

    This PDF file contains the editorial “The Spectrum of Medical Imaging in the 2015 International Year of Light” for JMI Vol. 2 Issue 03

  • Open Access

    Characterizing the contribution of cardiac and hepatic uptake in dedicated breast SPECT using tilted trajectories

    by K L Perez, S J Cutler, P Madhav, M P Tornai

    A small field of view, high resolution gamma camera has been integrated into a dedicated breast, single photon emission computed tomography (SPECT) device. The detector can be flexibly positioned relative to the breast and image beyond the chest wall, allowing the system to capture direct views of the heart and liver. The incomplete sampling of these organs creates artifacts in reconstructed images, complicating lesion detection. To understand the limits imposed on a 3D acquisition trajectory, sequential tilted trajectories at increasing polar tilt are utilized to collect data of anthropomorphic phantoms filled with aqueous (99m)Tc in a clinically realistic concentration ratio. The counts collected per projection between different scans and the SNR, contrast and resolution (FWHM) of two hot lesions were compared. As expected, the counts per projection increased when the camera had direct views of the heart and liver, but remained relatively constant at other angles. The SNR, contrast and FWHM were more affected by the insufficient sampling of the data by the large polar angles than by the cardiac and hepatic activity. An upper bound on polar tilt for each azimuthal position reduces the artifacts in the reconstructed images. Such trajectories were implemented to show artifact-free reconstructed images.


  • Measurements of an optimized beam for x-ray computed mammotomography

    by Randolph L Mckinley, Ehsan Samei, Caryl N Brzymialkiewicz, Martin P Tornai, C E Floyd

    Simulation results from previous studies indicate that a quasi-monochromatic x-ray beam can be produced using a newly developed beam filtration technique. This technique utilizes heavy filtration with novel high Z filter materials having k-edges just above those of CsI, producing a near monochromatic beam with mean energy optimized for detection. The value of a near monochromatic x-ray source for a fully 3D tomography application is the expected improved ability to separate tissues with very small differences in attenuation coefficients for a range of uncompressed breast sizes while maintaining dose levels at or below existing dual view mammography. In this study, we experimentally investigate a set of filter materials (Al, Cu, Ag, Ce, W, and Pb), filter thicknesses (10th, 100th, and 200th VL), and tube potentials (40-80 kVp) using a newly constructed test apparatus. Initial experimental results corroborate simulations and indicate that this approach can improve image quality (SNR) at constant dose. Al, Cu, W, and Pb provide optimal exposure efficiency results at 60 kVp and above. Decreasing relative improvements are observed above 100th VL filter thickness at 78 cm SID. Results are obtained without significant tube heating (except at 40 kVp). In addition, simulations indicate significant reductions in beam hardening. This optimized beam will be incorporated into a novel cone-beam x-ray computed mammotomography sub-system together with an emission tomograph in a dual modality CT/SPECT application specific emission and transmission tomography system for fully 3D uncompressed breast imaging.