Implementation and CT sampling characterization of a third-generation SPECT–CT system for dedicated breast imaging
- 1 July 2017
- journal article
- research article
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 4 (3) , 033502
Abstract
Stand-alone cone beam computed tomography (CT) and single-photon emission computed tomography (SPECT) systems capable of complex acquisition trajectories have previously been developed for breast imaging. Fully three-dimensional (3-D) motions of SPECT systems provide views into the chest wall and throughout the entire volume. The polar tilting capability of the CBCT system has shown improvement in sampling close to the chest wall, while eliminating cone beam artifacts. Here, a single hybrid SPECT–CT system, with each individual modality capable of independently traversing complex trajectories around a common pendant breast volume, was developed. We present the practical implementation of this design and preliminary results of the CT system. The fully 3-D SPECT was nested inside the suspended CT gantry and oriented perpendicular to the CT source–detector pair. Both subsystems were positioned on a rotation stage, with the combined polar and azimuthal motions enabling spherical trajectories. Six trajectories were used for initial evaluation of the tilt capable CT system. The developed system can achieve polar tilt angles with a <0.02-deg positioning error and no hysteresis. Initial imaging results demonstrate that additional off-axis projection views of various geometric resolution phantoms facilitate more complete sampling, more consistent attenuation value recovery, and markedly improved reconstructions. This system could have various applications in diagnostic or therapeutic breast imaging.Keywords
Funding Information
- Duke Department of Radiology
- National Cancer Institute of the National Institutes of Health (R01-CA096821)
- National Institutes of Health (R01-CA096821)
- Medical Imaging Training Program (T32-EB001040)
This publication has 61 references indexed in Scilit:
- X‐ray scatter correction method for dedicated breast computed tomographyMedical Physics, 2012
- Clinical Digital Breast Tomosynthesis System: Dosimetric CharacterizationRadiology, 2012
- InitialIn VivoQuantification of Tc-99m Sestamibi Uptake as a Function of Tissue Type in Healthy Breasts Using Dedicated Breast SPECT-CTJournal of Oncology, 2012
- Digital Breast Tomosynthesis Is Comparable to Mammographic Spot Views for Mass CharacterizationRadiology, 2012
- Initial Characterization of a Dedicated Breast PET/CT Scanner During Human ImagingJournal of Nuclear Medicine, 2009
- Breast tomosynthesis in clinical practice: initial resultsEuropean Radiology, 2009
- PET characteristics of a dedicated breast PET/CT scanner prototypePhysics in Medicine & Biology, 2009
- Dedicated Breast CT: Initial Clinical ExperienceRadiology, 2008
- Dedicated Cone-Beam Breast CT: Feasibility Study with Surgical Mastectomy SpecimensAmerican Journal of Roentgenology, 2007
- The anatomy of missed breast cancersSurgical Oncology, 1993