Jerimy Polf
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jerimy Polf has a total of 71 co-authors. Here are the top co-authors by number of shared publications:
Paul Maggi
University of Maryland School of Medicine
4 shared publications- Dennis Mackin
Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, United States of America
3 shared publications - Sam Beddar
Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
3 shared publications Carlos A. Barajas
Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD, United States
2 shared publicationsDennis S. Mackin
Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD, United States
2 shared publicationsMatthias K. Gobbert
Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD, United States
2 shared publications
Latest Publications
- Open Access
Single–molecule biodosimetry
Inferring characteristics of radiation exposure using biological molecules is extremely challenging. Current methods, in particular, lack a clear connection between dose and molecular response. Here, we demonstrate that resistive–pulse nanopore sensors enable single–molecule biodosimetry by quantifying the frequency of double–strand DNA scissions versus gamma radiation dose. The resulting response curve shows an elongated Gaussian behavior, reminiscent of cell survival rates versus dose. We demonstrate that the competition of radical damage of DNA—i.e., single–strand lesions that lead to breakage—with bimolecular radical loss captures the form of the response. Our sensors and protocol provide a foundation for numerous technological advances. These include rapid dosimetry for triage in emergency situations and ex vivo monitoring of radiotherapy effectiveness in order to tailor treatment to patient– and tumor–specific response.
Open AccessSingle–molecule biodosimetry
Inferring characteristics of radiation exposure using biological molecules is extremely challenging. Current methods, in particular, lack a clear connection between dose and molecular response. Here, we demonstrate that resistive–pulse nanopore sensors enable single–molecule biodosimetry by quantifying the frequency of double–strand DNA scissions versus gamma radiation dose. The resulting response curve shows an elongated Gaussian behavior, reminiscent of cell survival rates versus dose. We demonstrate that the competition of radical damage of DNA—i.e., single–strand lesions that lead to breakage—with bimolecular radical loss captures the form of the response. Our sensors and protocol provide a foundation for numerous technological advances. These include rapid dosimetry for triage in emergency situations and ex vivo monitoring of radiotherapy effectiveness in order to tailor treatment to patient– and tumor–specific response.
- Open Access
- 7 June 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (12) , 125001
The first PET glimpse of a proton FLASH beam
We demonstrate the first ever recorded positron-emission tomography (PET) imaging and dosimetry of a FLASH proton beam at the Proton Center of the MD Anderson Cancer Center. Two scintillating LYSO crystal arrays, read out by silicon photomultipliers, were configured with a partial field of view of a cylindrical poly-methyl methacrylate (PMMA) phantom irradiated by a FLASH proton beam. The proton beam had a kinetic energy of 75.8 MeV and an intensity of about 3.5 × 10 10 protons that were extracted over 101.5 ms-long spills. The radiation environment was characterized by cadmium–zinc–telluride and plastic scintillator counters. Preliminary results indicate that the PET technology used in our tests can efficiently record FLASH beam events. The instrument yielded informative and quantitative imaging and dosimetry of beam-activated isotopes in a PMMA phantom, as supported by Monte Carlo simulations. These studies open a new PET modality that can lead to improved imaging and monitoring of FLASH proton therapy.
- 7 June 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (12) , 125001
Open AccessThe first PET glimpse of a proton FLASH beam
We demonstrate the first ever recorded positron-emission tomography (PET) imaging and dosimetry of a FLASH proton beam at the Proton Center of the MD Anderson Cancer Center. Two scintillating LYSO crystal arrays, read out by silicon photomultipliers, were configured with a partial field of view of a cylindrical poly-methyl methacrylate (PMMA) phantom irradiated by a FLASH proton beam. The proton beam had a kinetic energy of 75.8 MeV and an intensity of about 3.5 × 10 10 protons that were extracted over 101.5 ms-long spills. The radiation environment was characterized by cadmium–zinc–telluride and plastic scintillator counters. Preliminary results indicate that the PET technology used in our tests can efficiently record FLASH beam events. The instrument yielded informative and quantitative imaging and dosimetry of beam-activated isotopes in a PMMA phantom, as supported by Monte Carlo simulations. These studies open a new PET modality that can lead to improved imaging and monitoring of FLASH proton therapy.
- Open Access
- 11 April 2022
- Published by Frontiers Media SA in Frontiers in Physics
- Vol. 10
Applications of Machine Learning to Improve the Clinical Viability of Compton Camera Based in vivo Range Verification in Proton Radiotherapy
We studied the application of a deep, fully connected Neural Network (NN) to process prompt gamma (PG) data measured by a Compton camera (CC) during the delivery of clinical proton radiotherapy beams. The network identifies 1) recorded “bad” PG events arising from background noise during the measurement, and 2) the correct ordering of PG interactions in the CC to help improve the fidelity of “good” data used for image reconstruction. PG emission from a tissue-equivalent target during irradiation with a 150 MeV proton beam delivered at clinical dose rates was measured with a prototype CC. Images were reconstructed from both the raw measured data and the measured data that was further processed with a neural network (NN) trained to identify “good” and “bad” PG events and predict the ordering of individual interactions within the good PG events. We determine if NN processing of the CC data could improve the reconstructed PG images to a level in which they could provide clinically useful information about the in vivo range and range shifts of the proton beams delivered at full clinical dose rates. Results showed that a deep, fully connected NN improved the achievable contrast to noise ratio (CNR) in our images by more than a factor of 8x. This allowed the path, range, and lateral width of the clinical proton beam within a tissue equivalent target to easily be identified from the PG images, even at the highest dose rates of a 150 MeV proton beam used for clinical treatments. On average, shifts in the beam range as small as 3 mm could be identified. However, when limited by the amount of PG data measured with our prototype CC during the delivery of a single proton pencil beam (∼1 × 109 protons), the uncertainty in the reconstructed PG images limited the identification of range shift to ∼5 mm. Substantial improvements in CC images were obtained during clinical beam delivery through NN pre-processing of the measured PG data. We believe this shows the potential of NNs to help improve and push CC-based PG imaging toward eventual clinical application for proton RT treatment delivery verification.
- 11 April 2022
- Published by Frontiers Media SA in Frontiers in Physics
- Vol. 10
Open AccessApplications of Machine Learning to Improve the Clinical Viability of Compton Camera Based in vivo Range Verification in Proton Radiotherapy
We studied the application of a deep, fully connected Neural Network (NN) to process prompt gamma (PG) data measured by a Compton camera (CC) during the delivery of clinical proton radiotherapy beams. The network identifies 1) recorded “bad” PG events arising from background noise during the measurement, and 2) the correct ordering of PG interactions in the CC to help improve the fidelity of “good” data used for image reconstruction. PG emission from a tissue-equivalent target during irradiation with a 150 MeV proton beam delivered at clinical dose rates was measured with a prototype CC. Images were reconstructed from both the raw measured data and the measured data that was further processed with a neural network (NN) trained to identify “good” and “bad” PG events and predict the ordering of individual interactions within the good PG events. We determine if NN processing of the CC data could improve the reconstructed PG images to a level in which they could provide clinically useful information about the in vivo range and range shifts of the proton beams delivered at full clinical dose rates. Results showed that a deep, fully connected NN improved the achievable contrast to noise ratio (CNR) in our images by more than a factor of 8x. This allowed the path, range, and lateral width of the clinical proton beam within a tissue equivalent target to easily be identified from the PG images, even at the highest dose rates of a 150 MeV proton beam used for clinical treatments. On average, shifts in the beam range as small as 3 mm could be identified. However, when limited by the amount of PG data measured with our prototype CC during the delivery of a single proton pencil beam (∼1 × 109 protons), the uncertainty in the reconstructed PG images limited the identification of range shift to ∼5 mm. Substantial improvements in CC images were obtained during clinical beam delivery through NN pre-processing of the measured PG data. We believe this shows the potential of NNs to help improve and push CC-based PG imaging toward eventual clinical application for proton RT treatment delivery verification.
- 25 February 2022
- Published by Elsevier in Physica Medica
- Vol. 94, S54-S55
FLASH in the Clinic Track (Oral Presentations) DOSIMETRIC EVALUATION OF DOSE RATE FALL-OFF AND BEAM COLLIMATION IN FLASH TREATMENT USING PROTON PENCIL BEAM SCANNING
- 25 February 2022
- Published by Elsevier in Physica Medica
- Vol. 94, S54-S55
FLASH in the Clinic Track (Oral Presentations) DOSIMETRIC EVALUATION OF DOSE RATE FALL-OFF AND BEAM COLLIMATION IN FLASH TREATMENT USING PROTON PENCIL BEAM SCANNING
- Open Access
Therapeutic Efficacy of Variable Biological Effectiveness of Proton Therapy in U-CH2 and MUG-Chor1 Human Chordoma Cell Death
Background: Chordoma is a cancer of spinal cord, skull base, and sacral area. Currently, the standard of care to treat chordoma is resection followed by radiation therapy. Since, chordoma is present in the spinal cord and these are very sensitive structures and often complete removal by surgery is not possible. As a result, chordoma has a high chance of recurrence and developing resistance to radiation therapy. In addition, treatment of chordoma by conventional radiation therapy can also damage normal tissues surrounding chordoma. Thus, current therapeutic options to treat chordoma are insufficient and novel therapies are desperately needed to treat locally advanced and metastatic chordoma. (2) Methods: In the present investigation, human chordoma cell lines of sacral origin MUG-Chor1 and U-CH2 were cultured and irradiated with Proton Beam Radiation using the clinical superconducting cyclotron and pencil-beam (active) scanning at Middle and End of the Spread-Out Bragg Peak (SOBP). Proton radiation was given at the following doses: Mug-Chor1 at 0, 1, 2, 4, and 8 Gy and U-CH2 at 0, 4, 8, 12, and 16 Gy. These doses were selected based on a pilot study in our lab and attempted to produce approximate survival fractions in the range of 1, 0.9, 0.5, 0.1, and 0.01, respectively, chosen for linear quadratic model fitting of the dose response. (3) Results: In this study, we investigated relative biological effectiveness (RBE) of proton radiation at the end of Spread Out Bragg Peak assuming that the reference radiation is a proton radiation in the middle of the SOBP. We observed differences in the survival of both Human chordoma cell lines, U-CH2 and MUG-Chor1. The data showed that there was a significantly higher cell death at the end of the Bragg peak as compared to middle of the Bragg peak. Based on the linear quadratic (LQ) fit for cell survival we calculated the RBE between M-SOBP and E-SOBP at 95% CI level and it was observed that RBE was higher than 1 at E-SOBP and caused significantly higher cell killing. Proton field at E-SOBP caused complex DNA damage in comparison to M-EOBP and the genes such as DNA topoisomerase 1, GTSE1, RAD51B were downregulated in E-SOBP treated cells. Thus, we conclude that there seems to be substantial variation in RBE (1.3–1.7) at the E-SOBP compared with the M-SOBP.
Open AccessTherapeutic Efficacy of Variable Biological Effectiveness of Proton Therapy in U-CH2 and MUG-Chor1 Human Chordoma Cell Death
Background: Chordoma is a cancer of spinal cord, skull base, and sacral area. Currently, the standard of care to treat chordoma is resection followed by radiation therapy. Since, chordoma is present in the spinal cord and these are very sensitive structures and often complete removal by surgery is not possible. As a result, chordoma has a high chance of recurrence and developing resistance to radiation therapy. In addition, treatment of chordoma by conventional radiation therapy can also damage normal tissues surrounding chordoma. Thus, current therapeutic options to treat chordoma are insufficient and novel therapies are desperately needed to treat locally advanced and metastatic chordoma. (2) Methods: In the present investigation, human chordoma cell lines of sacral origin MUG-Chor1 and U-CH2 were cultured and irradiated with Proton Beam Radiation using the clinical superconducting cyclotron and pencil-beam (active) scanning at Middle and End of the Spread-Out Bragg Peak (SOBP). Proton radiation was given at the following doses: Mug-Chor1 at 0, 1, 2, 4, and 8 Gy and U-CH2 at 0, 4, 8, 12, and 16 Gy. These doses were selected based on a pilot study in our lab and attempted to produce approximate survival fractions in the range of 1, 0.9, 0.5, 0.1, and 0.01, respectively, chosen for linear quadratic model fitting of the dose response. (3) Results: In this study, we investigated relative biological effectiveness (RBE) of proton radiation at the end of Spread Out Bragg Peak assuming that the reference radiation is a proton radiation in the middle of the SOBP. We observed differences in the survival of both Human chordoma cell lines, U-CH2 and MUG-Chor1. The data showed that there was a significantly higher cell death at the end of the Bragg peak as compared to middle of the Bragg peak. Based on the linear quadratic (LQ) fit for cell survival we calculated the RBE between M-SOBP and E-SOBP at 95% CI level and it was observed that RBE was higher than 1 at E-SOBP and caused significantly higher cell killing. Proton field at E-SOBP caused complex DNA damage in comparison to M-EOBP and the genes such as DNA topoisomerase 1, GTSE1, RAD51B were downregulated in E-SOBP treated cells. Thus, we conclude that there seems to be substantial variation in RBE (1.3–1.7) at the E-SOBP compared with the M-SOBP.
- 28 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 6 (6) , 731-739
Cramér–Rao Bound Evaluations of Compton Imager Designs for Proton Beam Range Verification
Compton imaging is an attractive tool for range verification and dose estimation in proton therapy. To investigate the application of CdZnTe based cameras for this task, we apply the uniform Cramér-Rao bound to dual-plane based designs with various interplane spacings and evaluate their bias-variance tradeoff. The investigation focuses on the 718 keV and 4.4 MeV prompt gammas emitted from proton interactions with 12C, and focuses on a detector geometry having two planes of 3×3 CdZnTe crystals with a volume of 2×2×1.5 cm3. When considering only interplane events, the improvement in minimum variance plateaus at 8 cm. However, when considering both intra-and inter-plane events with an efficiency factor, the optimum spacing is calculated to be around 4 cm as larger spacings degrade the performance with poorer efficiency and a lower interplane to intraplane fraction. In addition, the study uses the modified uniform Cramér-Rao bound based on a simulated distribution of prompt gamma rays expected from proton irradiation. The results show that the optimum spacing may be between 24 cm, depending on the specific bias-gradient norm.
- 28 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 6 (6) , 731-739
Cramér–Rao Bound Evaluations of Compton Imager Designs for Proton Beam Range Verification
Compton imaging is an attractive tool for range verification and dose estimation in proton therapy. To investigate the application of CdZnTe based cameras for this task, we apply the uniform Cramér-Rao bound to dual-plane based designs with various interplane spacings and evaluate their bias-variance tradeoff. The investigation focuses on the 718 keV and 4.4 MeV prompt gammas emitted from proton interactions with 12C, and focuses on a detector geometry having two planes of 3×3 CdZnTe crystals with a volume of 2×2×1.5 cm3. When considering only interplane events, the improvement in minimum variance plateaus at 8 cm. However, when considering both intra-and inter-plane events with an efficiency factor, the optimum spacing is calculated to be around 4 cm as larger spacings degrade the performance with poorer efficiency and a lower interplane to intraplane fraction. In addition, the study uses the modified uniform Cramér-Rao bound based on a simulated distribution of prompt gamma rays expected from proton irradiation. The results show that the optimum spacing may be between 24 cm, depending on the specific bias-gradient norm.
- Open Access
- 25 June 2021
- Published by Springer Nature in Research Square
A Study of The Clinical Viability of A Prototype Compton Camera for Prompt Gamma Imaging Based Proton Beam Range Verification
We present Compton camera (CC) based PG imaging for proton range verification at clinical dose rates. PG emission from a tissue-equivalent phantom during irradiation with clinical proton beams was measured with a prototype CC. Images were reconstructed of the raw measured data and of data processed with a neural network (NN) trained to identify “true” and “false” PG events. From these images, we determine if PG images produced by the prototype CC could provide clinically useful information about the in vivo range of the proton beams delivered during proton beam radiotherapy. NN processing of the data was found necessary to allow identification of the proton beam path from the PG images. Furthermore, to allow the localization of the end of the proton beam range with a precision of ≤ 3mm with the prototype CC, ~1 x 109 protons would need to be delivered, which is on the order of magnitude delivered for a standard proton radiotherapy treatment field. To obtain higher precision in beam range determination and to allow imaging a single proton pencil beam delivered within the full treatment field, further improvements in PG detection rates by the CC, NN data processing, and image reconstruction algorithms are needed.
- 25 June 2021
- Published by Springer Nature in Research Square
Open AccessA Study of The Clinical Viability of A Prototype Compton Camera for Prompt Gamma Imaging Based Proton Beam Range Verification
We present Compton camera (CC) based PG imaging for proton range verification at clinical dose rates. PG emission from a tissue-equivalent phantom during irradiation with clinical proton beams was measured with a prototype CC. Images were reconstructed of the raw measured data and of data processed with a neural network (NN) trained to identify “true” and “false” PG events. From these images, we determine if PG images produced by the prototype CC could provide clinically useful information about the in vivo range of the proton beams delivered during proton beam radiotherapy. NN processing of the data was found necessary to allow identification of the proton beam path from the PG images. Furthermore, to allow the localization of the end of the proton beam range with a precision of ≤ 3mm with the prototype CC, ~1 x 109 protons would need to be delivered, which is on the order of magnitude delivered for a standard proton radiotherapy treatment field. To obtain higher precision in beam range determination and to allow imaging a single proton pencil beam delivered within the full treatment field, further improvements in PG detection rates by the CC, NN data processing, and image reconstruction algorithms are needed.
- 5 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 6 (3) , 366-373
The Effects of Compton Camera Data Acquisition and Readout Timing on PG Imaging for Proton Range Verification
The purpose of this study was to determine how the characteristics of the data acquisition (DAQ) electronics of a Compton camera (CC) affect the quality of the recorded prompt gamma (PG) interaction data and the reconstructed images, during clinical proton beam delivery. We used the Monte-Carlo-plus-Detector-Effect (MCDE) model to simulate the delivery of a 150 MeV clinical proton pencil beam to a tissue-equivalent plastic phantom. With the MCDE model we analyzed how the recorded PG interaction data changed as two characteristics of the DAQ electronics of a CC were changed: (1) the number of data readout channels; and (2) the active charge collection, readout, and reset time. As the proton beam dose rate increased, the number of recorded PG single-, double-, and triple-scatter events decreased by a factor of 60× for the current DAQ configuration of the CC. However, as the DAQ readout channels were increased and the readout/reset timing decreased, the number of recorded events decreased by <5× at the highest clinical dose rate. The increased number of readout channels and reduced readout/reset timing also resulted in higher quality recorded data. That is, a higher percentage of the recorded double-and triple-scatters were “true” events (caused by a single incident gamma) and not “false” events (caused by multiple incident gammas). The increase in the number and the quality of recorded data allowed higher quality PG images to be reconstructed even at the highest clinical dose rates.
- 5 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 6 (3) , 366-373
The Effects of Compton Camera Data Acquisition and Readout Timing on PG Imaging for Proton Range Verification
The purpose of this study was to determine how the characteristics of the data acquisition (DAQ) electronics of a Compton camera (CC) affect the quality of the recorded prompt gamma (PG) interaction data and the reconstructed images, during clinical proton beam delivery. We used the Monte-Carlo-plus-Detector-Effect (MCDE) model to simulate the delivery of a 150 MeV clinical proton pencil beam to a tissue-equivalent plastic phantom. With the MCDE model we analyzed how the recorded PG interaction data changed as two characteristics of the DAQ electronics of a CC were changed: (1) the number of data readout channels; and (2) the active charge collection, readout, and reset time. As the proton beam dose rate increased, the number of recorded PG single-, double-, and triple-scatter events decreased by a factor of 60× for the current DAQ configuration of the CC. However, as the DAQ readout channels were increased and the readout/reset timing decreased, the number of recorded events decreased by <5× at the highest clinical dose rate. The increased number of readout channels and reduced readout/reset timing also resulted in higher quality recorded data. That is, a higher percentage of the recorded double-and triple-scatters were “true” events (caused by a single incident gamma) and not “false” events (caused by multiple incident gammas). The increase in the number and the quality of recorded data allowed higher quality PG images to be reconstructed even at the highest clinical dose rates.
- 12 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 5 (3) , 383-391
Secondary Particle Interactions in a Compton Camera Designed for in vivo Range Verification of Proton Therapy
The purpose of this study was to determine the types, proportions, and energies of secondary particle interactions in a Compton camera (CC) during the delivery of clinical proton beams. The delivery of clinical proton pencil beams ranging from 70 to 200 MeV incident on a water phantom was simulated using Geant4 software (version 10.4). The simulation included a CC similar to the configuration of a Polaris J3 CC designed to image prompt gammas (PGs) emitted during proton beam irradiation for the purpose of in vivo range verification. The interaction positions and energies of secondary particles in each CC detector module were scored. For a 150-MeV proton beam, a total of 156 688(575) secondary particles per 10 8 protons, primarily composed of gamma rays (46.31%), neutrons (41.37%), and electrons (8.88%), were found to reach the camera modules, and 79.37% of these particles interacted with the modules. Strategies for using CCs for proton range verification should include methods of reducing the large neutron backgrounds and low-energy non-PG radiation. The proportions of interaction types by module from this study may provide information useful for background suppression.
- 12 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 5 (3) , 383-391
Secondary Particle Interactions in a Compton Camera Designed for in vivo Range Verification of Proton Therapy
The purpose of this study was to determine the types, proportions, and energies of secondary particle interactions in a Compton camera (CC) during the delivery of clinical proton beams. The delivery of clinical proton pencil beams ranging from 70 to 200 MeV incident on a water phantom was simulated using Geant4 software (version 10.4). The simulation included a CC similar to the configuration of a Polaris J3 CC designed to image prompt gammas (PGs) emitted during proton beam irradiation for the purpose of in vivo range verification. The interaction positions and energies of secondary particles in each CC detector module were scored. For a 150-MeV proton beam, a total of 156 688(575) secondary particles per 10 8 protons, primarily composed of gamma rays (46.31%), neutrons (41.37%), and electrons (8.88%), were found to reach the camera modules, and 79.37% of these particles interacted with the modules. Strategies for using CCs for proton range verification should include methods of reducing the large neutron backgrounds and low-energy non-PG radiation. The proportions of interaction types by module from this study may provide information useful for background suppression.
- 13 May 2019
- Published by Wiley in Medical Physics
- Vol. 46 (7) , 3245-3253
Determination of proton stopping power ratio with dual‐energy CT in 3D‐printed tissue/air cavity surrogates
Purpose To study the accuracy with which proton stopping power ratio (SPR) can be determined with dual‐energy computed tomography (DECT) for small structures and bone–tissue–air interfaces like those found in the head or in the neck. Methods Hollow cylindrical polylactic acid (PLA) plugs (3 cm diameter, 5 cm height) were 3D printed containing either one or three septa with thicknesses t septa = 0.8, 1.6, 3.2, and 6.4 mm running along the length of the plug. The cylinders were inserted individually into a tissue‐equivalent head phantom (16 cm diameter, 5 cm height). First, DECT scans were obtained using a Siemens SOMATOM Definition Edge CT scanner. Effective atomic number (Z eff) and electron density (ρ e) images were reconstructed from the DECT to produce SPR‐CT images of each plug. Second, independent elemental composition analysis of the PLA plastic was used to determine the Zeff and ρe for calculating the theoretical SPR (SPR‐TH) using the Bethe–Bloch equation. Finally, for each plug, a direct measurement of SPR (SPR‐DM) was obtained in a clinical proton beam. The values of SPR‐CT, SPR‐TH, and SPR‐DM were compared. Results The SPR‐CT for PLA agreed with SPR‐DM for t septa ≥ 3 mm (for CT slice thicknesses of 0.5, 1.0, and 3.0 mm). The density of PLA was found to decrease with thickness when t septa < 3 mm. As t septa (and density) decreased, the SPR‐CT values also decreased, in good agreement with SPR‐DM and SPR‐TH. Conclusion Overall, the DECT‐based SPR‐CT was within 3% of SPR‐TH and SPR‐DM in the high‐density gradient regions of the 3D‐printed plugs for septa greater than ~ 3mm in thickness.
- 13 May 2019
- Published by Wiley in Medical Physics
- Vol. 46 (7) , 3245-3253
Determination of proton stopping power ratio with dual‐energy CT in 3D‐printed tissue/air cavity surrogates
Purpose To study the accuracy with which proton stopping power ratio (SPR) can be determined with dual‐energy computed tomography (DECT) for small structures and bone–tissue–air interfaces like those found in the head or in the neck. Methods Hollow cylindrical polylactic acid (PLA) plugs (3 cm diameter, 5 cm height) were 3D printed containing either one or three septa with thicknesses t septa = 0.8, 1.6, 3.2, and 6.4 mm running along the length of the plug. The cylinders were inserted individually into a tissue‐equivalent head phantom (16 cm diameter, 5 cm height). First, DECT scans were obtained using a Siemens SOMATOM Definition Edge CT scanner. Effective atomic number (Z eff) and electron density (ρ e) images were reconstructed from the DECT to produce SPR‐CT images of each plug. Second, independent elemental composition analysis of the PLA plastic was used to determine the Zeff and ρe for calculating the theoretical SPR (SPR‐TH) using the Bethe–Bloch equation. Finally, for each plug, a direct measurement of SPR (SPR‐DM) was obtained in a clinical proton beam. The values of SPR‐CT, SPR‐TH, and SPR‐DM were compared. Results The SPR‐CT for PLA agreed with SPR‐DM for t septa ≥ 3 mm (for CT slice thicknesses of 0.5, 1.0, and 3.0 mm). The density of PLA was found to decrease with thickness when t septa < 3 mm. As t septa (and density) decreased, the SPR‐CT values also decreased, in good agreement with SPR‐DM and SPR‐TH. Conclusion Overall, the DECT‐based SPR‐CT was within 3% of SPR‐TH and SPR‐DM in the high‐density gradient regions of the 3D‐printed plugs for septa greater than ~ 3mm in thickness.