Jinyong Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jinyong Kim has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Matthew L. Johnston
School of Electrical Engineering and Computer Science, Oregon State University, Corvallis, OR, USA
2 shared publications Carly V. Fengel
Department of Physics, Oregon State University, Corvallis, OR, USA
1 shared publicationChaoxuan Ma
Intel Labs, Santa Clara, CA, USA
1 shared publication- Cooper S. Levy
Intel Corporation
1 shared publication Duanni Huang
Intel Labs, Santa Clara, CA, USA
1 shared publication- Ethan D. Minot
Oregon State University
1 shared publication
Latest Publications
- Top Cited Papers
- 19 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 59 (3) , 690-701
8-λ × 50 Gbps/λ Heterogeneously Integrated Si-Ph DWDM Transmitter
We demonstrate a 3-D heterogeneously integrated dense wavelength-division multiplexing (DWDM) silicon-photonic transmitter simultaneously modulating eight 200-GHz spaced wavelengths at 50 Gbps/$\lambda $ each, to deliver an aggregate per-fiber bandwidth of 400 Gbps. All necessary$O$ -band optical components are fully integrated on the photonic integrated circuit (PIC), including an eight-wavelength laser array, a broadband semiconductor optical amplifier (SOA), and eight microring modulators (MRMs). Eight 50-Gbps non-return-to-zero (NRZ) modulator drivers, capable of delivering 2-$\text{V}_{\mathrm {pp}}$ modulation voltage, are integrated in a 28-nm CMOS electronic IC (EIC). The EIC also includes a thermal control unit (TCU) to align the eight MRMs to the eight laser wavelengths by appropriately tuning integrated MRM heaters. The measured energy efficiency at 50 Gb/s of the high-speed electronics, including serializer overhead, is 1.17 pJ/bit.- 19 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 59 (3) , 690-701
Top Cited Papers8-λ × 50 Gbps/λ Heterogeneously Integrated Si-Ph DWDM Transmitter
We demonstrate a 3-D heterogeneously integrated dense wavelength-division multiplexing (DWDM) silicon-photonic transmitter simultaneously modulating eight 200-GHz spaced wavelengths at 50 Gbps/$\lambda $ each, to deliver an aggregate per-fiber bandwidth of 400 Gbps. All necessary$O$ -band optical components are fully integrated on the photonic integrated circuit (PIC), including an eight-wavelength laser array, a broadband semiconductor optical amplifier (SOA), and eight microring modulators (MRMs). Eight 50-Gbps non-return-to-zero (NRZ) modulator drivers, capable of delivering 2-$\text{V}_{\mathrm {pp}}$ modulation voltage, are integrated in a 28-nm CMOS electronic IC (EIC). The EIC also includes a thermal control unit (TCU) to align the eight MRMs to the eight laser wavelengths by appropriately tuning integrated MRM heaters. The measured energy efficiency at 50 Gb/s of the high-speed electronics, including serializer overhead, is 1.17 pJ/bit. - 17 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 15 (6) , 1419-1429
Multi-Channel Biopotential Acquisition System Using Frequency-Division Multiplexing With Cable Motion Artifact Suppression
A multi-channel, CMOS-based biopotential acquisition system is presented that uses amplitude modulated, frequency division multiplexing (AM-FDM) to decrease wire count and provide resilience against motion artifacts and cable noise. Differential active electrode (AE) pairs capture surface biopotential signals, each modulated by a different carrier frequency and combined via current-domain summing. The presented approach requires only a single wire for signal transmission between AEs and back-end readout, along with clock and ground wires, to support multiple active electrodes using a 3-wire cable. Frequency modulation prior to transmission mitigates the effect of low-frequency cable motion artifacts and 50/60 Hz mains interference in the cable. A prototype FDM-based biopotential acquisition system was implemented in a 180 nm CMOS process, including a four-channel front-end active electrode IC for signal conditioning and modulation, and a back-end IC for demodulation and digitization. Each channel occupies 0.75 mm$^\text{2}$ and consumes 43.8$\mu$ W, inclusive of ADC power. Using both AE and BE ICs, a four-channel biopotential recording system is demonstrated using a 3-wire interface, where the system achieves attenuation of low-frequency cable motion artifacts by 15X and 60 Hz mains noise coupled into the cable by 62X.- 17 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 15 (6) , 1419-1429
Multi-Channel Biopotential Acquisition System Using Frequency-Division Multiplexing With Cable Motion Artifact Suppression
A multi-channel, CMOS-based biopotential acquisition system is presented that uses amplitude modulated, frequency division multiplexing (AM-FDM) to decrease wire count and provide resilience against motion artifacts and cable noise. Differential active electrode (AE) pairs capture surface biopotential signals, each modulated by a different carrier frequency and combined via current-domain summing. The presented approach requires only a single wire for signal transmission between AEs and back-end readout, along with clock and ground wires, to support multiple active electrodes using a 3-wire cable. Frequency modulation prior to transmission mitigates the effect of low-frequency cable motion artifacts and 50/60 Hz mains interference in the cable. A prototype FDM-based biopotential acquisition system was implemented in a 180 nm CMOS process, including a four-channel front-end active electrode IC for signal conditioning and modulation, and a back-end IC for demodulation and digitization. Each channel occupies 0.75 mm$^\text{2}$ and consumes 43.8$\mu$ W, inclusive of ADC power. Using both AE and BE ICs, a four-channel biopotential recording system is demonstrated using a 3-wire interface, where the system achieves attenuation of low-frequency cable motion artifacts by 15X and 60 Hz mains noise coupled into the cable by 62X.- 17 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 68 (5) , 1735-1739
Frequency-Division Multiplexing With Graphene Active Electrodes for Neurosensor Applications
Multielectrode arrays are used broadly for neural recording, both in vivo and for ex vivo cultured neurons. In most cases, recording sites are passive electrodes wired to external read-out circuitry, and the number of wires is at least equal to the number of recording sites. We present an approach to break the conventional N-wire, N-electrode array architecture using graphene active electrodes, which allow signal upconversion at the recording site and sharing of each interface wire among multiple active electrodes using frequency-division multiplexing (FDM). The presented work includes the design and implementation of a frequency modulation and readout architecture using graphene FET electrodes, a custom integrated circuit (IC) analog front-end (AFE), and digital demodulation. The AFE was fabricated in 0.18 μm CMOS; electrical characterization and multi-channel FDM results are provided, including GFET-based signal modulation and IC/DSP demodulation. Long-term, this approach can simultaneously enable high signal count, high spatial resolution, and high temporal precision to infer functional interactions between neurons while markedly decreasing access wires.
- 17 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 68 (5) , 1735-1739
Frequency-Division Multiplexing With Graphene Active Electrodes for Neurosensor Applications
Multielectrode arrays are used broadly for neural recording, both in vivo and for ex vivo cultured neurons. In most cases, recording sites are passive electrodes wired to external read-out circuitry, and the number of wires is at least equal to the number of recording sites. We present an approach to break the conventional N-wire, N-electrode array architecture using graphene active electrodes, which allow signal upconversion at the recording site and sharing of each interface wire among multiple active electrodes using frequency-division multiplexing (FDM). The presented work includes the design and implementation of a frequency modulation and readout architecture using graphene FET electrodes, a custom integrated circuit (IC) analog front-end (AFE), and digital demodulation. The AFE was fabricated in 0.18 μm CMOS; electrical characterization and multi-channel FDM results are provided, including GFET-based signal modulation and IC/DSP demodulation. Long-term, this approach can simultaneously enable high signal count, high spatial resolution, and high temporal precision to infer functional interactions between neurons while markedly decreasing access wires.