DKDaisuke Kawano

Daisuke Kawano

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Daisuke Kawano has a total of 121 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Clinical Characteristics and Timing of Accessory Pathway Reconduction During Catheter Ablation of Accessory Pathways

    by Wataru Sasaki, Hitoshi Mori, Daisuke Kawano, Kei Matsumoto, Naomichi Tanaka, Tsukasa Naganuma, Masataka Narita, Kazuhisa Matsumoto, Yoshifumi Ikeda, Takahide Arai, et al.

    Background: Catheter ablation of accessory pathways has high acute success rates; however, accessory pathway (AP) recurrence remains a clinically relevant issue. Although intra‐procedural AP reconduction is frequently encountered during ablation procedures, its timing, predictors, and clinical significance remain insufficiently characterized. Objectives: This study aimed to investigate the timing, electrophysiologic characteristics, and clinical implications of intra‐procedural AP reconduction during catheter ablation of manifest and concealed accessory pathways. Methods: We retrospectively analyzed 128 patients with manifest or concealed AP who underwent catheter ablation at our institution between May 28, 2015, and February 2025. Details of cases in which AP reconduction was observed during the 30 min waiting period after successful ablation, including clinical and procedural characteristics, were compared with those of patients without reconduction. Results: Intra‐procedural AP reconduction occurred in 23 patients (18.0%). The mean time to reconduction was 16.7 ± 7.0 min, with a maximum interval of 27 min. Compared with patients without reconduction, those with reconduction had a significantly longer time to pathway interruption, more frequent broad or oblique APs, and more complex procedural approaches requiring multiple anatomical access routes. Intra‐procedural reconduction was also associated with subsequent late recurrence. Fifteen of 23 events (65.2%) occurred ≥ 15 min after AP elimination. Conclusions: Intra‐procedural AP reconduction during catheter ablation of accessory pathways is not uncommon and appears to be associated with specific electrophysiologic and procedural characteristics as well as late recurrence. These findings may facilitate identification of patients at higher risk of reconduction and help guide intra‐procedural assessment during catheter ablation.

  • Open Access

    Large Language Model‐Based Localization of Premature Ventricular Contraction Origins: A Retrospective Diagnostic Accuracy Study

    by Kazuhisa Matsumoto, Yuya Fujisaki, Syunta Higuchi, Masataka Narita, Wataru Sasaki, Tsukasa Naganuma, Naomichi Tanaka, Daisuke Kawano, Kei Matsumoto, Wataru Yoshino, et al.

    Background: Accurate localization of premature ventricular contraction (PVC) origin from 12‐lead electrocardiography (ECG) is important for procedural planning in catheter ablation. Although convolutional neural network (CNN)‐based models have shown promising diagnostic performance, they require task‐specific training and remain limited in interpretability. We evaluated whether large language model (LLM)‐based ECG image interpretation could perform binary left‐versus‐right PVC origin localization from 12‐lead ECG images while providing a traceable diagnostic process. Methods: We retrospectively studied 157 patients who underwent successful catheter ablation of PVCs or idiopathic ventricular tachycardia. ECG images were classified as RIGHT‐origin ( n = 103) or LEFT‐origin ( n = 54) according to the final successful ablation site. Three approaches were compared: a CNN‐based baseline model, an LLM‐based one‐shot approach, and an LLM‐based staged extraction framework with deterministic rule‐based integration. Performance was evaluated across five independent seeds using positive predictive value (PPV), negative predictive value (NPV), recall, and PPV + NPV. Results: The CNN‐based baseline model achieved a PPV of 0.546 ± 0.058 and an NPV of 0.793 ± 0.047, with area under the curve values ranging from 0.595 to 0.730. The staged extraction framework generated a continuous rule‐based score with discrimination numerically comparable to the CNN‐based model (AUC 0.720 ± 0.045 vs. 0.712 ± 0.054). A stricter threshold, determined from training data, increased PPV at the expense of recall and warrants prospective external validation of this operating point. Conclusions: LLM‐based staged extraction demonstrated the potential to achieve binary left‐versus‐right PVC origin localization from 12‐lead ECG images while providing a traceable stepwise diagnostic process. The continuous rule‐based score showed discrimination numerically comparable to the CNN‐based model, and the strict threshold—determined using training data—identified a potential high‐PPV operating point that requires prospective external validation.


  • Open Access

    Midterm Efficacy of SubcutAneous Implantable CardioVErter ‐Defibrillator in ≤ 18 Year‐Old CHILDREN ( SAVE CHILDREN ‐ II Registry)

    by Hitoshi Mori, Taisuke Nabeshima, Kota Nagaoka, Hideo Fukunaga, Hidemori Hayashi, Osamu Inaba, Yuhei Isonaga, So Asano, Junichi Nitta, Shigeo Watanabe, et al.

    Background: The subcutaneous implantable cardioverter‐defibrillator (S‐ICD) avoids transvenous leads and is a promising option for sudden cardiac death (SCD) prevention in pediatric patients. However, mid‐term outcomes and post‐shock management strategies remain insufficiently characterized. Methods: This multicenter, retrospective observational study included pediatric patients (≤ 18 years) who underwent S‐ICD implantation between February 2016 and July 2021. Clinical characteristics, pre‐implant screening, procedural details, device‐related events, and follow‐up data were analyzed. The incidence and management of appropriate and inappropriate therapies and subsequent recurrence were evaluated. Results: Ninety‐six patients (median age 14.5 years) were enrolled and followed for a median of 70 months (29–75.0 months). Sensing vector suitability remained stable despite somatic growth. Appropriate shocks occurred in 32 patients (33.7%), while inappropriate shocks occurred in 27 (28.4%). After appropriate therapy, intensified pharmacological treatment and catheter ablation prevented recurrent device therapy in 45.5% and 50.0% of cases, respectively, although device shock occurred in 50.9% despite intervention. Following inappropriate therapy, device reprogramming and lifestyle guidance prevented recurrence in 71.4% of patients (15/21). Device‐related infection was rare (2 cases), and no lead fractures were observed. Conclusions: S‐ICD therapy demonstrated favorable mid‐term safety and efficacy in pediatric patients, with durable sensing performance and a low incidence of device‐related infection. Although inappropriate shocks were not uncommon, appropriate post‐shock management effectively reduced recurrence, supporting S‐ICD as a viable option for selected pediatric patients without pacing requirements.

  • Open Access

    Clinical Utility of Tissue Proximity Indication With a Variable‐Loop Circular Catheter for Pulmonary Vein Isolation

    by Masataka Narita, Daisuke Kawano, Naomichi Tanaka, Tsukasa Naganuma, Wataru Sasaki, Kazuhisa Matsumoto, Kei Matsumoto, Hitoshi Mori, Yoshifumi Ikeda, Ritsushi Kato

    Background: The variable‐loop circular catheter (VLCC, VARIPULSE) is a pulsed‐field ablation (PFA) catheter equipped with a Tissue Proximity Indication (TPI) function, which monitors catheter‐tissue contact. Although TPI‐negative sites have been reported to contribute to gap formation, no studies have evaluated the utility of real‐time function. This study assessed the success rate of pulmonary vein isolation (PVI) using the VLCC, incorporating the activated TPI function as the primary setting from the start of the procedure, representing an activated TPI function‐guided ablation approach. Methods: Between February 1 and September 3, 2025, 60 consecutive patients underwent PFA using the VLCC. After creating the 3D geometry using CARTOSOUND FAM before ablation, PVI using the VLCC was performed with the activated TPI function. After an initial two‐by‐two PFA set, the catheter orientation was adjusted to target areas without visible TPI‐positive tags. After applying an additional PFA application to ensure a circumferential TPI function‐on tags, a voltage map was created using a multielectrode catheter, and the rate of residual potentials was compared. Results: Using an activated TPI function‐guided PFA strategy, a first pass isolation was successfully achieved in 90% of patients (54/60) and in 97.1% of pulmonary veins (231/238). Multielectrode catheter mapping revealed residual antrum potentials in some cases, necessitating additional PFA applications in 3.8% of the pulmonary vein antrum (9/238). Conclusion: Activated TPI function‐guided PFA was associated with a low incidence of residual PV potentials, suggesting its potential utility to improve lesion continuity and procedural efficacy.

  • Open Access

    Interlesion Time as a Key Metric of Procedural Proficiency in Atrial Fibrillation Ablation: From Fellow to Attending

    by Hitoshi Mori, Daisuke Kawano, Masataka Narita, Kazuhisa Matsumoto, Tsukasa Naganuma, Wataru Sasaki, Naomichi Tanaka, Kazuhiko Kuinose, Kei Matsumoto, Yoshifumi Ikeda, et al.

    Introduction: Pulmonary vein isolation (PVI) is a cornerstone of atrial fibrillation (AF) ablation. Unlike balloon‐based or pulsed field ablation, radiofrequency ablation requires precise catheter control and poses a steeper learning curve. This study aimed to compare technical parameters between attending and fellow electrophysiologists (EPs) using data extracted via cloud‐based analysis. Methods: A total of 194 patients undergoing first‐time AF ablation between April 2023 and September 2024 were analyzed. Procedural metrics, including contact force (CF), inter‐lesion time (ILT), and catheter stability, were compared across six anatomical regions between three attending and five fellow EPs. Results: Attending EPs achieved significantly shorter ILTs in PVI with moderate‐to‐large effect sizes (Attending vs. Fellows, sec; right PV, 4.8 [4.3–8.4] vs. 9.6 [5.5–15.6], p < 0.001, Hedges' g = −0.578; left PV, 6.7 [4.5–12.8] vs. 12.7 [6.9–21.7], p < 0.001, Hedges' g = −0.473), while CF and catheter stability showed smaller differences. In non‐PV regions such as the CTI and roof line, ILT differences were smaller, suggesting early skill acquisition in linear ablation areas by fellows. Discussion: ILT best reflected operator experience, with shorter ILTs likely contributing to improved lesion continuity and procedural proficiency. Fellows demonstrated comparable CF and catheter stability, potentially aided by steerable sheath use. Mastery of anatomical navigation may be key to advancing proficiency. Conclusion: Shorter ILTs by attending EPs reflect greater procedural proficiency. Emphasizing anatomical understanding and deliberate catheter manipulation during training may enhance skill development and improve clinical outcomes.

  • Open Access

    Feasibility and Safety of High‐Power Settings for Electrical Isolation of the Superior Vena Cava Using a Catheter Capable of Local Impedance and Contact Force Monitoring

    by Daisuke Kawano, Hitoshi Mori, Kei Matsumoto, Naomichi Tanaka, Tsukasa Naganuma, Wataru Sasaki, Masataka Narita, Kazuhisa Matsumoto, Yoshifumi Ikeda, Kazuo Matsumoto, et al.

    Introduction: Recently, catheters incorporating both contact force (CF) sensing and local impedance (LI) measurement—an indicator of tissue temperature—have become clinically available. The present study aims to evaluate the efficacy of superior vena cava isolation (SVCI) using this catheter and to investigate the characteristics of impedance during the procedure. Methods: This retrospective study included 64 patients undergoing initial SVCI using the StablePoint catheter (40 W, CF 10–20 g, 8–10 s). We analyzed the success rate of SVCI and impedance data collected from 1 402 ablation points, with particular attention to the dynamics of LI and generator impedance (GI). Results: First‐pass isolation was achieved in all cases without complications such as phrenic nerve or sinus node injury. The LI drop was significantly greater and faster than the GI drop in all segments. The 90% decay time of LI was consistently 5–6 s, suggesting effective lesion formation during the resistive heating phase. LI provides a more reliable and localized indicator of tissue response than GI. The temporal profile of LI supports its utility in guiding safe and effective lesion delivery, particularly in the thin myocardial tissue of the SVC. Conclusion: High‐power ablation guided by LI and CF using the StablePoint catheter enables safe and effective SVCI with accurate real‐time assessment of lesion quality.

  • Open Access

    Deep Learning‐Based Prediction Model for Cardiac Resynchronization Therapy Responders Using Electrocardiogram Data

    by Hitoshi Mori, Yuya Fujisaki, Syunta Higuchi, Masataka Narita, Daisuke Kawano, Kazuhisa Matsumoto, Wataru Sasaki, Tsukasa Naganuma, Naomichi Tanaka, Kazuhiko Kuinose, et al.

    Background: Cardiac resynchronization therapy (CRT) is an established treatment for advanced heart failure, but approximately 30% of patients fail to respond. This study aimed to develop and evaluate deep learning models using preimplantation electrocardiogram (ECG) data to predict CRT response. Methods: We conducted a retrospective analysis of 285 patients who underwent CRT implantations and completed a 6‐month follow‐up. Responders were defined as those exhibiting ≥ 15% left ventricular end‐systolic volume reduction. Three models were developed: ResNet‐18 model trained on ECG images, self‐supervised learning (SSL) enhanced ResNet‐18 model, and LightGBM model trained on time‐series ECG data. Model performance was evaluated using accuracy, positive predictive value (PPV), and negative predictive value (NPV), averaged across 10 random seeds. Model interpretability using Gradient‐weighted Class Activation Mapping (Grad‐CAM) was performed on 36 responder cases. Results: The SSL + ResNet‐18 model demonstrated the most stable performance (accuracy 78.5% ± 5.5%) and PPV of 81.3%. The ResNet‐18 model achieved the highest PPV of 84.2% but had lower accuracy (74.1%) and larger variability. The LightGBM model exhibited the highest accuracy (79.4%) but the lowest PPV at 72.8%. Grad‐CAM showed that precordial leads were highlighted in 13 cases (36.1%), limb leads in 16 (44.4%), and both regions in 7 (19.4%), indicating heterogeneity in the model's focus and potential diversity in the electrical features contributing to CRT response prediction. Conclusion: AI models using preimplantation ECG data, particularly those based on image inputs, can effectively predict CRT responders. This approach may enhance patient selection and support personalized therapy strategies in CRT management.


  • Open Access

    Pacing and Ablation Technique Using Microelectrode for Pulmonary Vein Isolation Using a Local Impedance‐Guided Catheter

    by Hitoshi Mori, Hidehira Fukaya, Kazuhisa Matsumoto, Masataka Narita, Tsukasa Naganuma, Wataru Sasaki, Naomichi Tanaka, Daisuke Kawano, Yoshifumi Ikeda, Ritsushi Kato

    Background: The IntellaNav MiFi OI catheter (MiFi) is equipped with a sensor for local impedance (LI) monitoring and three mini‐electrodes. In this study, we investigated the target LI values for a successful pulmonary vein isolation (PVI) under the pacing and ablation technique using the MiFi catheter.Methods: Twenty‐seven patients underwent PVI using the MiFi catheter under mini electrode pacing from the MiFi catheter. The local impedance (LI) changes, generator impedance (GI) changes, and the time to capture loss were evaluated.Results: First‐pass isolations were obtained in 15 patients (57.7 %) for right PVs and in 22 patients (84.6 %) for left PVs. At gap sites, the impedance decrease was smaller than at non‐gap sites (non‐gap sites vs. gap sites; LI drop, 23.2 [±10.3] vs. 15.6 [±7.7] Ω, p < 0.0001; GI drop, 4.8 [±4.1] vs. 2.7 [3.9] Ω, p = 0.0026; %LI drop, −19.3 [±7.4] vs. −13.1 [±6.1] %, p < 0.0001; % GI drop, −5.1 [±4.2] vs. −2.9 [±4.2] %, p = 0.0020), suggesting that changes in impedance could be useful for predicting gaps. The cutoff values for predicting no gaps were identified as 15.0 Ω for the LI drop and −13.74% for the %LI drop.Conclusion: The LI showed greater changes than the GI and was also useful for predicting gaps. The cutoff values of 15.0 Ω for the LI drop and −13.74% for the %LI drop could predict conduction gaps. Under the monitoring of the LI, the pacing and ablation technique proved useful for PVI, even though the MiFi catheter does not have a CF sensor or ablation indices.


  • Open Access

    Feasibility and efficacy of 50 W ablation with the TactiFlex catheter for the initial pulmonary vein isolation of atrial fibrillation

    by Kazuhisa Matsumoto, Naomichi Tanaka, Wataru Sasaki, Tsukasa Naganuma, Masataka Narita, Daisuke Kawano, Hitoshi Mori, Kenta Tsutsui, Yoshifumi Ikeda, Takahide Arai, et al.

    Background: A novel contact force (CF) sensing catheter with a mesh‐shaped irrigation tip (TactiFlexTM SE, Abbott), is expected to provide safe and effective radiofrequency ablation. Our previous study revealed that the TactiFlex catheter needs a higher power for pulmonary vein isolation (PVI) due to the long tip length. This study aimed to examine the feasibility and safety of a 50 W ablation with the TactiFlex for PVI of atrial fibrillation (AF). Methods: A PVI was performed in 100 AF patients using TactiFlex catheters with a 50 W setting, 5‐20 g CF, and 15–20 s ablation time. The primary outcomes included a successful PVI, the incidence of first‐pass isolations (FPIs), the presence of PV conduction gaps, and the incidence of complications. Results: FPIs were achieved for 82/100 (82%) right pulmonary veins (RPVs) and 87/100 (87%) left PVs (LPVs). Among the unsuccessful RPV FPIs, residual carina potentials were observed in 16/18 cases (89%), PV gaps in 1/18 cases (5.5%), and both carina and PV gaps in 1/18 cases (5.5%). Similarly, among the unsuccessful LPV FPIs, residual carina potentials were observed in 11/13 cases (84.6%), PV gaps in 1/13 cases (7.7%), and both carina and PV gaps in 1/13 cases (7.7%). Periesophageal nerve injury occurred in 1/100 cases (1%), and no cardiac tamponade occurred. The overall AF‐free rate at one‐year was 81.7%. Conclusions: The 50 W ablation with the TactiFlex demonstrated a high rate of an FPI, low incidence of PV gaps, and proved to be a safe and effective approach for the initial PVI of AF.


  • Open Access

    Marked conduction time prolongation observed during atrial tachycardia originating from a giant left atrial appendage

    by Kazuhisa Matsumoto, Daisuke Kawano, Hitoshi Mori, Yoshifumi Ikeda, Ritsushi Kato

    We experienced a rare case of atrial flutter originating from the giant left appendage (LAA). The local potential of the ablation catheter presented with a rare finding, appearing up to 185 ms earlier than the surface P-wave in the distal LAA. With thoracoscopic LAA clipping, tachycardia was successfully controlled.image