Kevin Souris
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kevin Souris has a total of 81 co-authors. Here are the top co-authors by number of shared publications:
- Edmond Sterpin
KU Leuven
7 shared publications - Hugo Palmans
National Physical Laboratory
5 shared publications Séverine Rossomme
IBA Dosimetry GmbH
5 shared publications- John Aldo Lee
Université catholique de Louvain
4 shared publications - Lies Verpoest
UCLouvain, Avenue Hippocrate 54, Louvain-la-Neuve, WAL, 1348, BELGIUM
4 shared publications - Ana Maria Barragan Montero
Molecular Imaging, Radiotherapy and Oncology, Institut de Recherche Expérimentale et Clinique, UCLouvain, Belgium
3 shared publications
Latest Publications
- 5 June 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (14) , 145006
Water calorimetry-based beam quality correction factors for carbon and helium ion beams
Objective. To determine beam quality correction factors, kQ, in single-layer scanned carbon and helium ion beams using water calorimetry, thereby reducing uncertainties in dosimetry for light ion therapy. Approach. Water calorimetry measurements were performed under harmonized conditions at two synchrotron-based ion beam therapy centers (MedAustron, Austria and HIT, Germany). Measurements were conducted in the plateau region of single-layer scanned beams. Carbon ion beams covered nominal energies from 213.4 to 402.8 MeV/u, while helium ion beams were measured at 196.3 and 198.8 MeV/u. Multiple cylindrical (IBA FC65-G, PTW 30013) and plane-parallel (IBA PPC05, PPC40; PTW 34001, 34045) ionization chamber types were investigated. Results. kQ-factors were determined with standard uncertainties of approximately 1%, depending on chamber type and measurement condition. For all investigated chambers, inter-center agreement was observed within the combined standard uncertainties. Chamber-to-chamber variability was below 0.5% for chamber types for which two samples were available, except for the IBA PPC05, for which differences up to 1% were observed. For carbon ion beams, the measured kQ-factors are consistent with previously published water calorimetry-based results. However, systematic deviations up to 3% persist between experimentally determined and Monte Carlo-derived kQ values. The measured kQ-factors for helium ions show trends that are broadly similar to those observed in carbon ion beams across all chamber types. Significance. This work expands the experimental kQ-database for light ions by providing new carbon ion data and the first experimental kQ-factors for helium ion beams. These results provide essential experimental data for future refinement of dosimetry recommendations, and highlight persistent discrepancies between the experimental and Monte Carlo-based kQ-factors that require further investigation.
- 5 June 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (14) , 145006
Water calorimetry-based beam quality correction factors for carbon and helium ion beams
Objective. To determine beam quality correction factors, kQ, in single-layer scanned carbon and helium ion beams using water calorimetry, thereby reducing uncertainties in dosimetry for light ion therapy. Approach. Water calorimetry measurements were performed under harmonized conditions at two synchrotron-based ion beam therapy centers (MedAustron, Austria and HIT, Germany). Measurements were conducted in the plateau region of single-layer scanned beams. Carbon ion beams covered nominal energies from 213.4 to 402.8 MeV/u, while helium ion beams were measured at 196.3 and 198.8 MeV/u. Multiple cylindrical (IBA FC65-G, PTW 30013) and plane-parallel (IBA PPC05, PPC40; PTW 34001, 34045) ionization chamber types were investigated. Results. kQ-factors were determined with standard uncertainties of approximately 1%, depending on chamber type and measurement condition. For all investigated chambers, inter-center agreement was observed within the combined standard uncertainties. Chamber-to-chamber variability was below 0.5% for chamber types for which two samples were available, except for the IBA PPC05, for which differences up to 1% were observed. For carbon ion beams, the measured kQ-factors are consistent with previously published water calorimetry-based results. However, systematic deviations up to 3% persist between experimentally determined and Monte Carlo-derived kQ values. The measured kQ-factors for helium ions show trends that are broadly similar to those observed in carbon ion beams across all chamber types. Significance. This work expands the experimental kQ-database for light ions by providing new carbon ion data and the first experimental kQ-factors for helium ion beams. These results provide essential experimental data for future refinement of dosimetry recommendations, and highlight persistent discrepancies between the experimental and Monte Carlo-based kQ-factors that require further investigation.
- 4 April 2026
- Published by Elsevier in Physica Medica
- Vol. 145, 105799
Assessment of compact cylindrical and plane-parallel ionization chambers as reference dosimeters in high-energy photon beams
- 4 April 2026
- Published by Elsevier in Physica Medica
- Vol. 145, 105799
Assessment of compact cylindrical and plane-parallel ionization chambers as reference dosimeters in high-energy photon beams
- 20 January 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (3)
The dual gap ionization chamber: a novel ionization chamber design for reference dosimetry to automatically correct for recombination losses in emerging radiotherapy modalities
Current dosimetry protocols typically recommend multiple measurements to determine recombination correction factors (ks), increasing the time required for dose measurements in the quality assurance workflow. We propose a novel dual-gap ionization chamber (DGIC) design for reference dosimetry featuring two air gaps of different thicknesses within a single device. This design enables the determination of ks directly from the same measurements required to determine absorbed dose-to-water. Thus, eliminating the need for separate measurements to correct for recombination losses. The approach relies on analyzing the charge ratio between the two gaps, which can also be correlated with the average dose rate under Ultra High Dose Rates (UHDR) conditions. A DGIC prototype with electrode distances of 1 and 0.6 mm was developed and tested using different beam qualities: (1) a 240 MeV/n clinical carbon ion beam at conventional dose rates, (2) a 226 MeV continuous proton beam with a current between 5 and 800 nA, where the maximum approximately corresponds to 200 Gy/s in the treatment room and (3) a 9 MeV electron beam with a DPP from 0.03 to 4.2 Gy. ks-factors were derived for the top cavity using the DGIC method and compared against the following: For proton and carbon ions, comparisons were made with the Jaffe plot method. For the electron beam, it was compared with a dose rate independent device, a flashDiamond detector. A DGIC prototype was able to successfully correct for recombination losses under different beam modalities: for initial recombination in a clinical carbon ion beam, volume recombination in UHDR proton beam with average dose rates of 200 Gy/s and in UHDPP electron beams tested up to a DPP of 4.2 Gy. A DGIC design and its inherent method provides a practical and accurate way of determining dose and dose rate in emerging radiotherapy treatment modalities.
- 20 January 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (3)
The dual gap ionization chamber: a novel ionization chamber design for reference dosimetry to automatically correct for recombination losses in emerging radiotherapy modalities
Current dosimetry protocols typically recommend multiple measurements to determine recombination correction factors (ks), increasing the time required for dose measurements in the quality assurance workflow. We propose a novel dual-gap ionization chamber (DGIC) design for reference dosimetry featuring two air gaps of different thicknesses within a single device. This design enables the determination of ks directly from the same measurements required to determine absorbed dose-to-water. Thus, eliminating the need for separate measurements to correct for recombination losses. The approach relies on analyzing the charge ratio between the two gaps, which can also be correlated with the average dose rate under Ultra High Dose Rates (UHDR) conditions. A DGIC prototype with electrode distances of 1 and 0.6 mm was developed and tested using different beam qualities: (1) a 240 MeV/n clinical carbon ion beam at conventional dose rates, (2) a 226 MeV continuous proton beam with a current between 5 and 800 nA, where the maximum approximately corresponds to 200 Gy/s in the treatment room and (3) a 9 MeV electron beam with a DPP from 0.03 to 4.2 Gy. ks-factors were derived for the top cavity using the DGIC method and compared against the following: For proton and carbon ions, comparisons were made with the Jaffe plot method. For the electron beam, it was compared with a dose rate independent device, a flashDiamond detector. A DGIC prototype was able to successfully correct for recombination losses under different beam modalities: for initial recombination in a clinical carbon ion beam, volume recombination in UHDR proton beam with average dose rates of 200 Gy/s and in UHDPP electron beams tested up to a DPP of 4.2 Gy. A DGIC design and its inherent method provides a practical and accurate way of determining dose and dose rate in emerging radiotherapy treatment modalities.
- 14 January 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (2)
Experimental determination of beam quality correction factors in scanned proton beams using water calorimetry
Objective. To measure beam quality correction factors (kQ) in single-layer scanned proton beams using water calorimetry for three ionization chamber types commonly used in clinical proton dosimetry. Approach. Measurements were performed at two proton therapy centers using clinical proton beams with nominal energies of 150, 220 and 226 MeV, at a reference depth of 4 cm. The kQ-factors were obtained by comparing absorbed dose-to-water determinations from a water calorimeter with ionization chamber readings under identical conditions. Three ionization chamber models were investigated: the IBA FC65-G (cylindrical), PPC05 and PPC40 (plane-parallel). Two independent calorimeter setups were used across three measurement campaigns. Main results. The measured kQ-factors showed strong agreement with current TRS-398 Rev. 1 (2024) recommendations and literature data. For the FC65-G chamber, excellent alignment was observed with previous water calorimetry-based measurements. For the PPC40 chamber, both chambers yielded consistent results within 0.5% of TRS-398 Rev. 1. For the PPC05 chambers, a maximum deviation of 1.4% was observed relative to TRS-398 Rev. 1, and inter-chamber variability was within 0.5%. The use of two calorimeter setups yielded consistent results within 0.2%, supporting their validity. Significance. This study presents new experimental kQ-factors for ionization chambers in single-layer scanned proton beams, contributing to the currently scarce experimental database, providing further validation of the TRS-398 Rev. 1 (2024) recommendations, and supplying benchmark data for future Monte Carlo-based kQ calculations.
- 14 January 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (2)
Experimental determination of beam quality correction factors in scanned proton beams using water calorimetry
Objective. To measure beam quality correction factors (kQ) in single-layer scanned proton beams using water calorimetry for three ionization chamber types commonly used in clinical proton dosimetry. Approach. Measurements were performed at two proton therapy centers using clinical proton beams with nominal energies of 150, 220 and 226 MeV, at a reference depth of 4 cm. The kQ-factors were obtained by comparing absorbed dose-to-water determinations from a water calorimeter with ionization chamber readings under identical conditions. Three ionization chamber models were investigated: the IBA FC65-G (cylindrical), PPC05 and PPC40 (plane-parallel). Two independent calorimeter setups were used across three measurement campaigns. Main results. The measured kQ-factors showed strong agreement with current TRS-398 Rev. 1 (2024) recommendations and literature data. For the FC65-G chamber, excellent alignment was observed with previous water calorimetry-based measurements. For the PPC40 chamber, both chambers yielded consistent results within 0.5% of TRS-398 Rev. 1. For the PPC05 chambers, a maximum deviation of 1.4% was observed relative to TRS-398 Rev. 1, and inter-chamber variability was within 0.5%. The use of two calorimeter setups yielded consistent results within 0.2%, supporting their validity. Significance. This study presents new experimental kQ-factors for ionization chambers in single-layer scanned proton beams, contributing to the currently scarce experimental database, providing further validation of the TRS-398 Rev. 1 (2024) recommendations, and supplying benchmark data for future Monte Carlo-based kQ calculations.
- Open Access
- 24 November 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (23) , 235014
Investigation of compact multi-layer ionization chamber detector designs for quality control of CBCT-based synthetic CTs for adaptive proton therapy
Objective. To define an optimal compact multi-layer ionization chamber (MLIC) detector design for proton radiography (PR) acquisition as quality control (QC) of cone-beam CT (CBCT)-based synthetic-CTs (sCTs) in the context of adaptive proton therapy (APT). Approach. In 10 patients, 51 PR measurements were simulated. To replicate measured IDDs (=IDDs Meas ), noise based on actual PR measurements was added to the raw IDDs (=IDDs Raw ). IDDs Meas were discretized to 1–6 mm and limited to 30–50 mm to mimic MLIC detector designs with 30 different ionization chamber (IC) pitch and detector length combinations. The influence of noise and space/limited IDD information on the ability to determine range shifts was assessed by comparing IDD Raw to IDD Meas . To assess how well different MLIC detector designs identify/detect sCT uncertainties, 43 error scenarios were generated by modifying CT calibration curves of muscle/fat/bone-like density tissues. The range shifts were calculated by fitting nominal IDDs to IDDs Meas of each error scenario using least-square. The normalized comparison of expected and measured range shifts is reported as normalized relative range shifts, ideally equaling zero. Main results. Each MLIC detector design was investigated based on 506 IDD Raw , with 100 different noise contributions each, resulting in 50600 IDD Meas . The relative range shift and relative normalized range shift increased with a larger IC pitch. An increased detector length allowed for a larger IC pitch. Detector lengths < 35 mm proved insufficient for sampling enough relevant IDD information. Significance. This study demonstrates that range shifts due to density errors between measured and simulated IDDs can be identified using a compact MLIC detector. A normalized relative range shift uncertainty detection of ⩽ 0.51 % can be verified with a minimum 45 mm detector length and maximum 3 mm IC pitch. The obtained results suggest that a compact MLIC detector can be used to verify the integrity of CBCT-based sCTs, enabling APT based on sCTs.
- 24 November 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (23) , 235014
Open AccessInvestigation of compact multi-layer ionization chamber detector designs for quality control of CBCT-based synthetic CTs for adaptive proton therapy
Objective. To define an optimal compact multi-layer ionization chamber (MLIC) detector design for proton radiography (PR) acquisition as quality control (QC) of cone-beam CT (CBCT)-based synthetic-CTs (sCTs) in the context of adaptive proton therapy (APT). Approach. In 10 patients, 51 PR measurements were simulated. To replicate measured IDDs (=IDDs Meas ), noise based on actual PR measurements was added to the raw IDDs (=IDDs Raw ). IDDs Meas were discretized to 1–6 mm and limited to 30–50 mm to mimic MLIC detector designs with 30 different ionization chamber (IC) pitch and detector length combinations. The influence of noise and space/limited IDD information on the ability to determine range shifts was assessed by comparing IDD Raw to IDD Meas . To assess how well different MLIC detector designs identify/detect sCT uncertainties, 43 error scenarios were generated by modifying CT calibration curves of muscle/fat/bone-like density tissues. The range shifts were calculated by fitting nominal IDDs to IDDs Meas of each error scenario using least-square. The normalized comparison of expected and measured range shifts is reported as normalized relative range shifts, ideally equaling zero. Main results. Each MLIC detector design was investigated based on 506 IDD Raw , with 100 different noise contributions each, resulting in 50600 IDD Meas . The relative range shift and relative normalized range shift increased with a larger IC pitch. An increased detector length allowed for a larger IC pitch. Detector lengths < 35 mm proved insufficient for sampling enough relevant IDD information. Significance. This study demonstrates that range shifts due to density errors between measured and simulated IDDs can be identified using a compact MLIC detector. A normalized relative range shift uncertainty detection of ⩽ 0.51 % can be verified with a minimum 45 mm detector length and maximum 3 mm IC pitch. The obtained results suggest that a compact MLIC detector can be used to verify the integrity of CBCT-based sCTs, enabling APT based on sCTs.
- Open Access
- 24 September 2025
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 36
Dynamic proton arc treatment planning study for oesophageal cancer
- 24 September 2025
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 36
Open AccessDynamic proton arc treatment planning study for oesophageal cancer
- 4 August 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (16)
Radiation damage evaluation of materials for radiotherapy quality assurance devices under high dose and ultra-high dose rate electron and proton beams
FLASH radiotherapy is a promising technique based on the delivery of ultra-high dose rates (UHDR) to spare healthy tissue. Quality Assurance (QA) devices such as phantoms and ionization chambers are typically made out of polymeric materials. This study aims to characterize radiation damage in common materials used for QA devices and identify which of them can withstand UHDR conditions. A variety of materials commonly used in phantoms and ionization chambers, with diverse characteristics (transparent, opaque, conductive and non-conductive) were irradiated using 68 MeV proton and 20 MeV electron beams, reaching doses up to 1 MGy under UHDR conditions (average dose rates of 100 – 500 Gy/s). Material damage was evaluated through optical, chemical, mechanical and electrical tests. External appearance of some materials significantly changed after irradiation. All transparent materials exhibited change in color post-irradiation. Chemical analyses conducted after irradiation and repeated two years later indicated partial recovery in some materials. No significant difference in damage was observed between proton and electron irradiation, suggesting comparable radiation damage mechanisms. Dose rate alone did not exacerbate damage beyond total dose effects; however, extended irradiation at high dose rates resulted in thermal damage under some conditions. Mechanical testing revealed increased fragility, changes in hardness and dimensions, while some materials experienced significant changes in dielectric constant and conductivity. Materials such as PMMA, PC, POM, and its conductive variant POM ELS, are unsuitable for prolonged irradiations at UHDR due to significant structural degradation observed. For see-through phantom construction, CPS offers a more durable alternative to PMMA. For detector construction, PEEK (for non-conductive parts)and graphite (for conductive parts) demonstrated promising durability, making them preferable choices under high dose and UHDR conditions. The higher stability of these materials can be attributed to the presence of aromatic rings in their chemical structure, which enhances radiation resistance.
- 4 August 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (16)
Radiation damage evaluation of materials for radiotherapy quality assurance devices under high dose and ultra-high dose rate electron and proton beams
FLASH radiotherapy is a promising technique based on the delivery of ultra-high dose rates (UHDR) to spare healthy tissue. Quality Assurance (QA) devices such as phantoms and ionization chambers are typically made out of polymeric materials. This study aims to characterize radiation damage in common materials used for QA devices and identify which of them can withstand UHDR conditions. A variety of materials commonly used in phantoms and ionization chambers, with diverse characteristics (transparent, opaque, conductive and non-conductive) were irradiated using 68 MeV proton and 20 MeV electron beams, reaching doses up to 1 MGy under UHDR conditions (average dose rates of 100 – 500 Gy/s). Material damage was evaluated through optical, chemical, mechanical and electrical tests. External appearance of some materials significantly changed after irradiation. All transparent materials exhibited change in color post-irradiation. Chemical analyses conducted after irradiation and repeated two years later indicated partial recovery in some materials. No significant difference in damage was observed between proton and electron irradiation, suggesting comparable radiation damage mechanisms. Dose rate alone did not exacerbate damage beyond total dose effects; however, extended irradiation at high dose rates resulted in thermal damage under some conditions. Mechanical testing revealed increased fragility, changes in hardness and dimensions, while some materials experienced significant changes in dielectric constant and conductivity. Materials such as PMMA, PC, POM, and its conductive variant POM ELS, are unsuitable for prolonged irradiations at UHDR due to significant structural degradation observed. For see-through phantom construction, CPS offers a more durable alternative to PMMA. For detector construction, PEEK (for non-conductive parts)and graphite (for conductive parts) demonstrated promising durability, making them preferable choices under high dose and UHDR conditions. The higher stability of these materials can be attributed to the presence of aromatic rings in their chemical structure, which enhances radiation resistance.
- Open Access
- 15 April 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (8) , 085012
Impact of manufacturing tolerances on Monte Carlo calculated k Q , Q 0 factors for plane-parallel ionisation chambers in proton beams
Objective. In the recent update of the TRS-398 Code of Practice (CoP), Monte Carlo results were incorporated into the derivation of recommended beam quality correction factors for ionisation chambers (IC) in proton beams. While the underlying Monte Carlo simulations implement detailed models only based on the nominal geometries from manufacturer blueprints, this paper considers the potential geometric deviations in plane-parallel IC arising from manufacturing tolerances that can reach 10%. Approach. A representative model of a plane-parallel IC has been designed using the Monte Carlo code GATE/Geant4, from which beam quality correction factors have been derived. Subsequently, the results of a reference geometry are compared to those of perturbed geometries, in which the parameters are modified according to the tolerances specified in a standard. Main results. The comparison between the reference and perturbed geometries reveals no significant differences, as they show an agreement within one standard deviation for all the cases studied, with relative deviations not exceeding 0.5%. From these results, we estimate the maximum added uncertainty from manufacturing tolerances on Monte Carlo calculated kQ factors to be about 0.7%. Significance. Overall, the current use of nominal dimensions of plane-parallel IC from manufacturer’s blueprints remains consistent for beam quality correction factor calculations via Monte Carlo simulations, which therefore support the latest results recommended by the TRS-398 CoP.
- 15 April 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (8) , 085012
Open AccessImpact of manufacturing tolerances on Monte Carlo calculated k Q , Q 0 factors for plane-parallel ionisation chambers in proton beams
Objective. In the recent update of the TRS-398 Code of Practice (CoP), Monte Carlo results were incorporated into the derivation of recommended beam quality correction factors for ionisation chambers (IC) in proton beams. While the underlying Monte Carlo simulations implement detailed models only based on the nominal geometries from manufacturer blueprints, this paper considers the potential geometric deviations in plane-parallel IC arising from manufacturing tolerances that can reach 10%. Approach. A representative model of a plane-parallel IC has been designed using the Monte Carlo code GATE/Geant4, from which beam quality correction factors have been derived. Subsequently, the results of a reference geometry are compared to those of perturbed geometries, in which the parameters are modified according to the tolerances specified in a standard. Main results. The comparison between the reference and perturbed geometries reveals no significant differences, as they show an agreement within one standard deviation for all the cases studied, with relative deviations not exceeding 0.5%. From these results, we estimate the maximum added uncertainty from manufacturing tolerances on Monte Carlo calculated kQ factors to be about 0.7%. Significance. Overall, the current use of nominal dimensions of plane-parallel IC from manufacturer’s blueprints remains consistent for beam quality correction factor calculations via Monte Carlo simulations, which therefore support the latest results recommended by the TRS-398 CoP.
- 3 February 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (4) , 045003
Proton arc therapy plan optimization with energy layer pre-selection driven by organ at risk sparing and delivery time
Objective. As proton arc therapy (PAT) approaches clinical implementation, optimizing treatment plans for this innovative delivery modality remains challenging, especially in addressing arc delivery time. Existing algorithms for minimizing delivery time are either optimal but computationally demanding or fast but at the expense of sacrificing many degrees of freedom. In this study, we introduce a flexible method for pre-selecting energy layers (EL) in PAT treatment planning before the actual robust spot weight optimization. Approach. Our EL pre-selection method employs metaheuristics to minimize a bi-objective function, considering a dynamic delivery time proxy and tumor geometrical coverage penalized as a function of selected organs-at-risk crossing. It is capable of parallelizing multiple instances of the problem. We evaluate the method using three different treatment sites, providing a comprehensive dosimetric analysis benchmarked against dynamic proton arc plans generated with early energy layer selection and spot assignment (ELSA) and IMPT plans in RayStation TPS. Result. The algorithm efficiently generates Pareto-optimal EL pre-selections in approximately 5 min. Subsequent PAT treatment plans derived from these selections and optimized within the TPS, demonstrate high-quality target coverage, achieving a high conformity index, and effective sparing of organs at risk. These plans meet clinical goals while achieving a 20%–40% reduction in delivery time compared to ELSA plans. Significance. The proposed algorithm offers speed and efficiency, producing high-quality PAT plans by placing proton arc sectors to efficiently reduce delivery time while maintaining good target coverage and healthy tissues sparing.
- 3 February 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (4) , 045003
Proton arc therapy plan optimization with energy layer pre-selection driven by organ at risk sparing and delivery time
Objective. As proton arc therapy (PAT) approaches clinical implementation, optimizing treatment plans for this innovative delivery modality remains challenging, especially in addressing arc delivery time. Existing algorithms for minimizing delivery time are either optimal but computationally demanding or fast but at the expense of sacrificing many degrees of freedom. In this study, we introduce a flexible method for pre-selecting energy layers (EL) in PAT treatment planning before the actual robust spot weight optimization. Approach. Our EL pre-selection method employs metaheuristics to minimize a bi-objective function, considering a dynamic delivery time proxy and tumor geometrical coverage penalized as a function of selected organs-at-risk crossing. It is capable of parallelizing multiple instances of the problem. We evaluate the method using three different treatment sites, providing a comprehensive dosimetric analysis benchmarked against dynamic proton arc plans generated with early energy layer selection and spot assignment (ELSA) and IMPT plans in RayStation TPS. Result. The algorithm efficiently generates Pareto-optimal EL pre-selections in approximately 5 min. Subsequent PAT treatment plans derived from these selections and optimized within the TPS, demonstrate high-quality target coverage, achieving a high conformity index, and effective sparing of organs at risk. These plans meet clinical goals while achieving a 20%–40% reduction in delivery time compared to ELSA plans. Significance. The proposed algorithm offers speed and efficiency, producing high-quality PAT plans by placing proton arc sectors to efficiently reduce delivery time while maintaining good target coverage and healthy tissues sparing.
- 13 December 2022
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 67 (24) , 245017
Bi-criteria Pareto optimization to balance irradiation time and dosimetric objectives in proton arc therapy
Objective . Proton arc therapy (PAT) is a new delivery technique that exploits the continuous rotation of the gantry to distribute the therapeutic dose over many angular windows instead of using a few static fields, as in conventional (intensity-modulated) proton therapy. Although coming along with many potential clinical and dosimetric benefits, PAT has also raised a new optimization challenge. In addition to the dosimetric goals, the beam delivery time (BDT) needs to be considered in the objective function. Considering this bi-objective formulation, the task of finding a good compromise with appropriate weighting factors can turn out to be cumbersome. Approach . We have computed Pareto-optimal plans for three disease sites: a brain, a lung, and a liver, following a method of iteratively choosing weight vectors to approximate the Pareto front with few points. Mixed-integer programming (MIP) was selected to state the bi-criteria PAT problem and to find Pareto optimal points with a suited solver. Main results . The trade-offs between plan quality and beam irradiation time ( static BDT) are investigated by inspecting three plans from the Pareto front. The latter are carefully picked to demonstrate significant differences in dose distribution and delivery time depending on their location on the frontier. The results were benchmarked against IMPT and SPArc plans showing the strength of degrees of freedom coming along with MIP optimization. Significance . This paper presents for the first time the application of bi-criteria optimization to the PAT problem, which eventually permits the planners to select the best treatment strategy according to the patient conditions and clinical resources available.
- 13 December 2022
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 67 (24) , 245017
Bi-criteria Pareto optimization to balance irradiation time and dosimetric objectives in proton arc therapy
Objective . Proton arc therapy (PAT) is a new delivery technique that exploits the continuous rotation of the gantry to distribute the therapeutic dose over many angular windows instead of using a few static fields, as in conventional (intensity-modulated) proton therapy. Although coming along with many potential clinical and dosimetric benefits, PAT has also raised a new optimization challenge. In addition to the dosimetric goals, the beam delivery time (BDT) needs to be considered in the objective function. Considering this bi-objective formulation, the task of finding a good compromise with appropriate weighting factors can turn out to be cumbersome. Approach . We have computed Pareto-optimal plans for three disease sites: a brain, a lung, and a liver, following a method of iteratively choosing weight vectors to approximate the Pareto front with few points. Mixed-integer programming (MIP) was selected to state the bi-criteria PAT problem and to find Pareto optimal points with a suited solver. Main results . The trade-offs between plan quality and beam irradiation time ( static BDT) are investigated by inspecting three plans from the Pareto front. The latter are carefully picked to demonstrate significant differences in dose distribution and delivery time depending on their location on the frontier. The results were benchmarked against IMPT and SPArc plans showing the strength of degrees of freedom coming along with MIP optimization. Significance . This paper presents for the first time the application of bi-criteria optimization to the PAT problem, which eventually permits the planners to select the best treatment strategy according to the patient conditions and clinical resources available.