LVLies Verpoest

Lies Verpoest

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Lies Verpoest has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Water calorimetry-based beam quality correction factors for carbon and helium ion beams

    by Lies Verpoest, Séverine Rossomme, Kevin Souris, Thomas Tessonnier, Andrea Mairani, Ivan D Muñoz, Stephan Brons, Oliver Jaekel, Kilian-Simon Baumann, Hermann Fuchs, et al.

    Objective. To determine beam quality correction factors, kQ, in single-layer scanned carbon and helium ion beams using water calorimetry, thereby reducing uncertainties in dosimetry for light ion therapy. Approach. Water calorimetry measurements were performed under harmonized conditions at two synchrotron-based ion beam therapy centers (MedAustron, Austria and HIT, Germany). Measurements were conducted in the plateau region of single-layer scanned beams. Carbon ion beams covered nominal energies from 213.4 to 402.8 MeV/u, while helium ion beams were measured at 196.3 and 198.8 MeV/u. Multiple cylindrical (IBA FC65-G, PTW 30013) and plane-parallel (IBA PPC05, PPC40; PTW 34001, 34045) ionization chamber types were investigated. Results. kQ-factors were determined with standard uncertainties of approximately 1%, depending on chamber type and measurement condition. For all investigated chambers, inter-center agreement was observed within the combined standard uncertainties. Chamber-to-chamber variability was below 0.5% for chamber types for which two samples were available, except for the IBA PPC05, for which differences up to 1% were observed. For carbon ion beams, the measured kQ-factors are consistent with previously published water calorimetry-based results. However, systematic deviations up to 3% persist between experimentally determined and Monte Carlo-derived kQ values. The measured kQ-factors for helium ions show trends that are broadly similar to those observed in carbon ion beams across all chamber types. Significance. This work expands the experimental kQ-database for light ions by providing new carbon ion data and the first experimental kQ-factors for helium ion beams. These results provide essential experimental data for future refinement of dosimetry recommendations, and highlight persistent discrepancies between the experimental and Monte Carlo-based kQ-factors that require further investigation.

  • Assessment of compact cylindrical and plane-parallel ionization chambers as reference dosimeters in high-energy photon beams

    by Lies Verpoest, Séverine Rossomme, Norman Durny, Marina Orts, Hugo Palmans, Kevin Souris, John Lee


  • The dual gap ionization chamber: a novel ionization chamber design for reference dosimetry to automatically correct for recombination losses in emerging radiotherapy modalities

    by Marina Orts, Séverine Rossomme, Kevin Souris, Victor de Beco, Thomas Haas, Norman Durny, Guillaume Gabriel Houyoux, Sébastien Penninckx, Lies Verpoest, Verdi Vanreusel, et al.

    Current dosimetry protocols typically recommend multiple measurements to determine recombination correction factors (ks), increasing the time required for dose measurements in the quality assurance workflow. We propose a novel dual-gap ionization chamber (DGIC) design for reference dosimetry featuring two air gaps of different thicknesses within a single device. This design enables the determination of ks directly from the same measurements required to determine absorbed dose-to-water. Thus, eliminating the need for separate measurements to correct for recombination losses. The approach relies on analyzing the charge ratio between the two gaps, which can also be correlated with the average dose rate under Ultra High Dose Rates (UHDR) conditions. A DGIC prototype with electrode distances of 1 and 0.6 mm was developed and tested using different beam qualities: (1) a 240 MeV/n clinical carbon ion beam at conventional dose rates, (2) a 226 MeV continuous proton beam with a current between 5 and 800 nA, where the maximum approximately corresponds to 200 Gy/s in the treatment room and (3) a 9 MeV electron beam with a DPP from 0.03 to 4.2 Gy. ks-factors were derived for the top cavity using the DGIC method and compared against the following: For proton and carbon ions, comparisons were made with the Jaffe plot method. For the electron beam, it was compared with a dose rate independent device, a flashDiamond detector. A DGIC prototype was able to successfully correct for recombination losses under different beam modalities: for initial recombination in a clinical carbon ion beam, volume recombination in UHDR proton beam with average dose rates of 200 Gy/s and in UHDPP electron beams tested up to a DPP of 4.2 Gy. A DGIC design and its inherent method provides a practical and accurate way of determining dose and dose rate in emerging radiotherapy treatment modalities.


  • Experimental determination of beam quality correction factors in scanned proton beams using water calorimetry

    by Lies Verpoest, Séverine Rossomme, Kevin Souris, Peter Kuess, Hugo Palmans, Stefano Lorentini, John Aldo Lee

    Objective. To measure beam quality correction factors (kQ) in single-layer scanned proton beams using water calorimetry for three ionization chamber types commonly used in clinical proton dosimetry. Approach. Measurements were performed at two proton therapy centers using clinical proton beams with nominal energies of 150, 220 and 226 MeV, at a reference depth of 4 cm. The kQ-factors were obtained by comparing absorbed dose-to-water determinations from a water calorimeter with ionization chamber readings under identical conditions. Three ionization chamber models were investigated: the IBA FC65-G (cylindrical), PPC05 and PPC40 (plane-parallel). Two independent calorimeter setups were used across three measurement campaigns. Main results. The measured kQ-factors showed strong agreement with current TRS-398 Rev. 1 (2024) recommendations and literature data. For the FC65-G chamber, excellent alignment was observed with previous water calorimetry-based measurements. For the PPC40 chamber, both chambers yielded consistent results within 0.5% of TRS-398 Rev. 1. For the PPC05 chambers, a maximum deviation of 1.4% was observed relative to TRS-398 Rev. 1, and inter-chamber variability was within 0.5%. The use of two calorimeter setups yielded consistent results within 0.2%, supporting their validity. Significance. This study presents new experimental kQ-factors for ionization chambers in single-layer scanned proton beams, contributing to the currently scarce experimental database, providing further validation of the TRS-398 Rev. 1 (2024) recommendations, and supplying benchmark data for future Monte Carlo-based kQ calculations.