Ragab Abdallah Mahmoud
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ragab Abdallah Mahmoud has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Ahmed Emam
Faculty of Engineering, Electrical Power and Machines Department, Cairo University, Giza, Egypt
1 shared publication- Ayman Al-Ahwal
Communication and Electronics Department , Pyramid-Institute for Engineering and Technology , Giza , Egypt
1 shared publication Ehab S. Elwakil
Power Electronics and Energy Conversion Department Electronics Research Institute Cairo Egypt
1 shared publicationEhab Serry Elwakil
Power Electronics and Energy Conversion Department Electronics Research Institute Cairo Egypt
1 shared publicationK. G. Ghaly
Electrical Power and Machines Department, Faculty of Engineering, Helwan University, Helwan, Egypt
1 shared publication- Mohamed Adel Esmaeel Salama
Department of Electrical Power and Machines Engineering, Faculty of Helwan Engineering, Capital University (formerly Helwan University), Cairo, Egypt.
1 shared publication
Latest Publications
- Open Access
- 18 May 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Numerical backup protection scheme based on alienation indices of voltage and current measurements practically applied to synchronous generators
Differential current relays are the primary protection for detecting fault disturbances within the protection zone of three-phase synchronous generator stator windings. This paper presents a numerical backup protection scheme, based on the alienation algorithm, which serves as a redundant protection when the main differential current relay fails to isolate stator winding faults. The proposed method quantifies a set of alienation indices derived from fifteen Pearson correlation coefficients, calculated for the three-phase voltages and currents measured at the load terminals of the generator stator windings. A novel set of tripping characteristic curves, formulated from the alienation indices, enables the implementation of secondary protection functions. The method effectively detects fault disturbances and voltage/current imbalance conditions in the three-phase generator signals. The experimental validation is performed using a motor–generator set equipped with voltage and current transformers installed at the generator load terminals. The system hardware is emulated through a DAC and personal computer, while the alienation algorithm is implemented and processed using the LABVIEW software environment. Extensive experimental investigations were carried out to validate the proposed method under various fault scenarios affecting the generator. The results demonstrate the alienation algorithm’s notable simplicity, effectiveness, reliability, and efficiency. Quantitatively, the protection scheme achieved security and dependability levels exceeding 99.80%, while its reliability and accuracy surpassed 99.60%. Moreover, the proposed scheme reduces the protection malfunction rate to only 0.37%. Compared to the coherence-based alienation method for analyzing voltage and current signals, the correlation-based alienation method provides superior response speed, improved performance metrics, greater accuracy, and a more reliable assessment of asymmetry and disturbance levels. An alienation tripping-time curve is created for the backup protection scheme, enabling time-delayed tripping under fault conditions, and its operating speed can be flexibly adjusted to meet specific protection requirements.
- 18 May 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessNumerical backup protection scheme based on alienation indices of voltage and current measurements practically applied to synchronous generators
Differential current relays are the primary protection for detecting fault disturbances within the protection zone of three-phase synchronous generator stator windings. This paper presents a numerical backup protection scheme, based on the alienation algorithm, which serves as a redundant protection when the main differential current relay fails to isolate stator winding faults. The proposed method quantifies a set of alienation indices derived from fifteen Pearson correlation coefficients, calculated for the three-phase voltages and currents measured at the load terminals of the generator stator windings. A novel set of tripping characteristic curves, formulated from the alienation indices, enables the implementation of secondary protection functions. The method effectively detects fault disturbances and voltage/current imbalance conditions in the three-phase generator signals. The experimental validation is performed using a motor–generator set equipped with voltage and current transformers installed at the generator load terminals. The system hardware is emulated through a DAC and personal computer, while the alienation algorithm is implemented and processed using the LABVIEW software environment. Extensive experimental investigations were carried out to validate the proposed method under various fault scenarios affecting the generator. The results demonstrate the alienation algorithm’s notable simplicity, effectiveness, reliability, and efficiency. Quantitatively, the protection scheme achieved security and dependability levels exceeding 99.80%, while its reliability and accuracy surpassed 99.60%. Moreover, the proposed scheme reduces the protection malfunction rate to only 0.37%. Compared to the coherence-based alienation method for analyzing voltage and current signals, the correlation-based alienation method provides superior response speed, improved performance metrics, greater accuracy, and a more reliable assessment of asymmetry and disturbance levels. An alienation tripping-time curve is created for the backup protection scheme, enabling time-delayed tripping under fault conditions, and its operating speed can be flexibly adjusted to meet specific protection requirements.
- Open Access
- 20 June 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-26
Adaptive overcurrent protection considering fault current limiters effect
Due to the rise in power consumption in recent years, the rated capacity of the power system has increased, resulting in an increase in the presence of Distributed Generators (DGs) in electrical networks. As a result, short-circuit currents surge when shunt faults occur. Fault Current Limiters (FCLs) are an effective way to suppress fault currents in the power systems. On the other hand, FCLs have an impact on the response speed of the protective devices, such as over-current relays (OCRs), which increase the relay operating time, raising the electrical and mechanical stresses on the system equipment. This paper presents an adaptive OCR algorithm considering the FCLs effect without any delay time. The proposed algorithm includes two modules: (1) a Z-score algorithm based on both the mean and the standard deviation values of the input current data, which is used to detect fault conditions, and (2) tripping characteristic curves based on the current Mean Ratio, which are applied to estimate the appropriate operating time of the adaptive OCR. To verify the method performance, a power system with real parameters is simulated on the Alternative Transient Program platform, and the algorithm procedure is implemented in the MATLAB program. Extensive simulation studies of load changes and various fault types are conducted, encompassing a wide range of fault initiation angles, fault resistances, and fault zones. The quantitative findings of these studies are analyzed in the presence and absence of FCLs/DGs. The simulation results indicate that the proposed algorithm can operate online and adjust its operating time settings automatically. As a consequence, it is able to detect fault instances upon which the relay sends a tripping flag, yet remains inactive under normal operating conditions. The algorithm speed and sensitivity are controllable using a moving data window size. Moreover, it is characterized by being easy to use, reliable, and accurate. Furthermore, the Z-score of the phase current can be used to identify the faulty phase and classify the fault type. In addition, the algorithm can be integrated with other digital protection and automation systems to be applied in conventional and smart grids.
- 20 June 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-26
Open AccessAdaptive overcurrent protection considering fault current limiters effect
Due to the rise in power consumption in recent years, the rated capacity of the power system has increased, resulting in an increase in the presence of Distributed Generators (DGs) in electrical networks. As a result, short-circuit currents surge when shunt faults occur. Fault Current Limiters (FCLs) are an effective way to suppress fault currents in the power systems. On the other hand, FCLs have an impact on the response speed of the protective devices, such as over-current relays (OCRs), which increase the relay operating time, raising the electrical and mechanical stresses on the system equipment. This paper presents an adaptive OCR algorithm considering the FCLs effect without any delay time. The proposed algorithm includes two modules: (1) a Z-score algorithm based on both the mean and the standard deviation values of the input current data, which is used to detect fault conditions, and (2) tripping characteristic curves based on the current Mean Ratio, which are applied to estimate the appropriate operating time of the adaptive OCR. To verify the method performance, a power system with real parameters is simulated on the Alternative Transient Program platform, and the algorithm procedure is implemented in the MATLAB program. Extensive simulation studies of load changes and various fault types are conducted, encompassing a wide range of fault initiation angles, fault resistances, and fault zones. The quantitative findings of these studies are analyzed in the presence and absence of FCLs/DGs. The simulation results indicate that the proposed algorithm can operate online and adjust its operating time settings automatically. As a consequence, it is able to detect fault instances upon which the relay sends a tripping flag, yet remains inactive under normal operating conditions. The algorithm speed and sensitivity are controllable using a moving data window size. Moreover, it is characterized by being easy to use, reliable, and accurate. Furthermore, the Z-score of the phase current can be used to identify the faulty phase and classify the fault type. In addition, the algorithm can be integrated with other digital protection and automation systems to be applied in conventional and smart grids.
- Open Access
- 12 March 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 8487
Transmission line faults detection and classification using new tripping characteristics based on statistical coherence for current measurements
Power transmission lines are critical components of a power system that connect power stations to consumers. To maintain reliability and stability of the system, faults should be correctly classified and cleared as soon as possible. In this article, a coherence-based protection scheme for faults detection and classification on transmission lines (TLs) is proposed. Besides, the scheme introduces a new model of tripping characteristics based on six coherence coefficients that are computed only for current waves measured at the TL sending end. The power network under test is simulated using the ATP software, and signals analysis and the performance evaluation of the technique are performed in the MATLAB environment. The protection performance is investigated under different fault conditions, such as fault type, fault location, fault resistance, fault inception angle and power flow angle. The extensive simulation cases have demonstrated that the suggested technique is successful in detecting and classifying all ten shunt faults in the transmission line within a half-cycle time. Moreover, the protection security, sensitivity, and response speed are amended by changing the numerical values of the coherence setting and data window. Furthermore, it is applicable in both conventional and smart grids, and it is independent of the specifications of the system equipment and current transformers.
- 12 March 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 8487
Open AccessTransmission line faults detection and classification using new tripping characteristics based on statistical coherence for current measurements
Power transmission lines are critical components of a power system that connect power stations to consumers. To maintain reliability and stability of the system, faults should be correctly classified and cleared as soon as possible. In this article, a coherence-based protection scheme for faults detection and classification on transmission lines (TLs) is proposed. Besides, the scheme introduces a new model of tripping characteristics based on six coherence coefficients that are computed only for current waves measured at the TL sending end. The power network under test is simulated using the ATP software, and signals analysis and the performance evaluation of the technique are performed in the MATLAB environment. The protection performance is investigated under different fault conditions, such as fault type, fault location, fault resistance, fault inception angle and power flow angle. The extensive simulation cases have demonstrated that the suggested technique is successful in detecting and classifying all ten shunt faults in the transmission line within a half-cycle time. Moreover, the protection security, sensitivity, and response speed are amended by changing the numerical values of the coherence setting and data window. Furthermore, it is applicable in both conventional and smart grids, and it is independent of the specifications of the system equipment and current transformers.
- Open Access
- 1 November 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-26
Experimental performance verification of an intelligent detection and assessment scheme for disturbances and imbalances of three-phase synchronous machine output using coherence estimators
In this article, power quality disturbances, such as voltage and current unbalances, series and shunt faults, are monitored in three-phase synchronous machines. Because the imbalances affect machine efficiency and service life, it is essential to figure out whether the three-phase voltages/currents are balanced or unbalanced. An integrated detection algorithm is proposed to detect the unbalanced voltages/currents and various abnormal conditions precisely and quickly, which is based on the coherence estimator. Most existing detection methods require more than one cycle time to determine the contingency conditions, while the proposed technique detects these situations in a fast and discrete protection system. The suggested scheme acquires instantaneous measurements of the three-phase voltages and currents taken at the synchronous machine terminals in order to calculate fifteen coherence coefficients that are utilized to detect and assess any unbalance or trouble accurately and swiftly. A new proposal for imbalance and disturbance indicators based on the coherence estimators is developed in this study. Multiple test cases have been conducted to validate the proposed algorithm capabilities using a real power system, which includes a motor-generator set, a three-phase load and measurement transformers. The experimental results have been revealed that the relay reliability and accuracy percentages have been found to be 98.28% and 98.52%, respectively. The quantitative findings of the imbalance and disturbance assessment are recorded.
- 1 November 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-26
Open AccessExperimental performance verification of an intelligent detection and assessment scheme for disturbances and imbalances of three-phase synchronous machine output using coherence estimators
In this article, power quality disturbances, such as voltage and current unbalances, series and shunt faults, are monitored in three-phase synchronous machines. Because the imbalances affect machine efficiency and service life, it is essential to figure out whether the three-phase voltages/currents are balanced or unbalanced. An integrated detection algorithm is proposed to detect the unbalanced voltages/currents and various abnormal conditions precisely and quickly, which is based on the coherence estimator. Most existing detection methods require more than one cycle time to determine the contingency conditions, while the proposed technique detects these situations in a fast and discrete protection system. The suggested scheme acquires instantaneous measurements of the three-phase voltages and currents taken at the synchronous machine terminals in order to calculate fifteen coherence coefficients that are utilized to detect and assess any unbalance or trouble accurately and swiftly. A new proposal for imbalance and disturbance indicators based on the coherence estimators is developed in this study. Multiple test cases have been conducted to validate the proposed algorithm capabilities using a real power system, which includes a motor-generator set, a three-phase load and measurement transformers. The experimental results have been revealed that the relay reliability and accuracy percentages have been found to be 98.28% and 98.52%, respectively. The quantitative findings of the imbalance and disturbance assessment are recorded.
- Open Access
- 9 May 2023
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2023 (5)
Coherence‐based integrated detection and assessment algorithm for voltages and currents unbalance/disturbance in three‐phase synchronous generators: A validation of simulation results
The phenomenon of imbalance is a variation of voltage and current waveforms from a perfect sinusoidal waveform, which is considered a crucial challenge in power systems. Uneven loads and disturbances result in three‐phase voltage/current unbalance that leads to a temperature rise and low output curves at synchronous machines. Thus, the unbalance/fault must be recognized and avoided. This article suggests a methodology to detect and evaluate three‐phase voltage and current unbalance/fault using a coherence algorithm. The suggested scheme develops integrated protection functions that can be divided into three modules: voltage unbalance, current unbalance, and power factor unbalance. Therefore, it can be useful in mitigation techniques applied to compensate the voltage unbalance effects. The present protection introduces a new proposal of closed‐tripping curves based on the values range of nine coherence factors. To investigate the protection performance, a segment of power grid with real parameters’ information is simulated utilizing ATP platform. Several fault types, such as shunt and series faults, are conducted on the simulated system to analyze the results and monitor the system status using the coherence statistic processed in MATLAB software. The results show that the approach is smart, swift, precise, reliable and stable. Moreover, the algorithm can be practically implemented, and represents a base for digital unbalance/fault detectors and relays because its performance is superior in detecting Power Quality Disturbances (PQDs).
- 9 May 2023
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2023 (5)
Open AccessCoherence‐based integrated detection and assessment algorithm for voltages and currents unbalance/disturbance in three‐phase synchronous generators: A validation of simulation results
The phenomenon of imbalance is a variation of voltage and current waveforms from a perfect sinusoidal waveform, which is considered a crucial challenge in power systems. Uneven loads and disturbances result in three‐phase voltage/current unbalance that leads to a temperature rise and low output curves at synchronous machines. Thus, the unbalance/fault must be recognized and avoided. This article suggests a methodology to detect and evaluate three‐phase voltage and current unbalance/fault using a coherence algorithm. The suggested scheme develops integrated protection functions that can be divided into three modules: voltage unbalance, current unbalance, and power factor unbalance. Therefore, it can be useful in mitigation techniques applied to compensate the voltage unbalance effects. The present protection introduces a new proposal of closed‐tripping curves based on the values range of nine coherence factors. To investigate the protection performance, a segment of power grid with real parameters’ information is simulated utilizing ATP platform. Several fault types, such as shunt and series faults, are conducted on the simulated system to analyze the results and monitor the system status using the coherence statistic processed in MATLAB software. The results show that the approach is smart, swift, precise, reliable and stable. Moreover, the algorithm can be practically implemented, and represents a base for digital unbalance/fault detectors and relays because its performance is superior in detecting Power Quality Disturbances (PQDs).
- Open Access
- 24 April 2023
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2023 (4)
Adaptive overcurrent relay (AOCR) based on Fano Factors of current signals
A Fano Factor‐based adaptive overcurrent protection scheme, that automatically adjusts the protection settings in response to the prevailing conditions of the power system, is presented. Both phase and ground overcurrent relays are based on the same mathematical algorithm to calculate the operating time using Fano Factors (FFs) estimated for phase and ground current signals, respectively. Effectiveness of the proposed adaptive overcurrent method is validated for various fault types under a plethora of loading current levels, besides a wide range of fault inception angles and fault resistance. Simulation results confirm that the proposed algorithm can detect series and shunt faults, differentiate between grounding and phase faults, and adapt the relay operating time settings using the FF for all conditions examined. The relay algorithm speed and sensitivity are controllable using both the FF setting values and moving data window size. Moreover, it is characterized by being simple, reliable, accurate, and can be implemented practically as a base of digital protective relay for use in substation automation systems and phasor measurement units.
- 24 April 2023
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2023 (4)
Open AccessAdaptive overcurrent relay (AOCR) based on Fano Factors of current signals
A Fano Factor‐based adaptive overcurrent protection scheme, that automatically adjusts the protection settings in response to the prevailing conditions of the power system, is presented. Both phase and ground overcurrent relays are based on the same mathematical algorithm to calculate the operating time using Fano Factors (FFs) estimated for phase and ground current signals, respectively. Effectiveness of the proposed adaptive overcurrent method is validated for various fault types under a plethora of loading current levels, besides a wide range of fault inception angles and fault resistance. Simulation results confirm that the proposed algorithm can detect series and shunt faults, differentiate between grounding and phase faults, and adapt the relay operating time settings using the FF for all conditions examined. The relay algorithm speed and sensitivity are controllable using both the FF setting values and moving data window size. Moreover, it is characterized by being simple, reliable, accurate, and can be implemented practically as a base of digital protective relay for use in substation automation systems and phasor measurement units.
- Open Access
- 19 November 2022
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2023 (1)
Smart automatic synchronization system based on coherence algorithm for power grids
An automatic synchronizing system is useful to reconnect two separated segments of a power system. This article describes a smart synchronizer based on coherence indices computed for voltage and current waves to value the synchronization level during normal operating conditions. The coherence index is a measure of the similarity degree between two time‐series waves taken from the two subsystems. Thus, it can be used to detect any system disturbance, and to identify the synchronous operation. To investigate the technique performance, a power system with real parameters' data is simulated on Alternative Transient Program (ATP) platform, and the algorithm procedure is implemented in MATLAB software. The simulation results indicate the possibility of the method application practically, and it can operate online and automatically for various networks. Besides, it can select only one coherence setting for the synchronization assessment, and alter the setting according to the prevailed conditions of the networks. In addition, it is considered an integrated scheme which combines both synchronizing and protection functions. Moreover, it offers a new design of relay operating characteristics to differentiate between the synchronization and non‐synchronization operation. Consequently, the synchronizer transmits a closing command to the intended CB, yet stays idle under contingency events.
- 19 November 2022
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2023 (1)
Open AccessSmart automatic synchronization system based on coherence algorithm for power grids
An automatic synchronizing system is useful to reconnect two separated segments of a power system. This article describes a smart synchronizer based on coherence indices computed for voltage and current waves to value the synchronization level during normal operating conditions. The coherence index is a measure of the similarity degree between two time‐series waves taken from the two subsystems. Thus, it can be used to detect any system disturbance, and to identify the synchronous operation. To investigate the technique performance, a power system with real parameters' data is simulated on Alternative Transient Program (ATP) platform, and the algorithm procedure is implemented in MATLAB software. The simulation results indicate the possibility of the method application practically, and it can operate online and automatically for various networks. Besides, it can select only one coherence setting for the synchronization assessment, and alter the setting according to the prevailed conditions of the networks. In addition, it is considered an integrated scheme which combines both synchronizing and protection functions. Moreover, it offers a new design of relay operating characteristics to differentiate between the synchronization and non‐synchronization operation. Consequently, the synchronizer transmits a closing command to the intended CB, yet stays idle under contingency events.
- Open Access
- 25 September 2022
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2022 (12) , 1190-1207
Experimental results and technique evaluation based on correlation function for a backup protection of synchronous generator stator windings
Unbalanced loads and faults cause power quality problems in power grids, which may lead to system elements failure, particularly to synchronous generators. Faults detection and identification of the disturbance severity level are essential in the grids. Important equipment are often protected with dual protection systems. A backup protection operates and trips appropriate circuit breaker(s) only if the main protection fails to detect the disturbance presence or miss opening the breakers. This paper proposes a backup protection scheme for detecting and evaluating the disruption severity of voltage and current signals for protecting the synchronous generators. This scheme is based on a numerical technique of correlation applied for the electrical signals to detect and assess the fault situation. Different fault types are experimentally conducted on a motor‐generator set to test the proposed algorithm effectiveness using Data Acquisition Card (DAC) and LABVIEW software. The scheme has proven to be successful for fault detection and assessment. The algorithm has shown high reliability at various faults and operating conditions. Moreover, the practical results reveal that the scheme is able to evaluate the severity degree of disturbances/unbalances, and it is effective and secure considering the acceptable overloading, harmonics and temporary faults in power grids.
- 25 September 2022
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2022 (12) , 1190-1207
Open AccessExperimental results and technique evaluation based on correlation function for a backup protection of synchronous generator stator windings
Unbalanced loads and faults cause power quality problems in power grids, which may lead to system elements failure, particularly to synchronous generators. Faults detection and identification of the disturbance severity level are essential in the grids. Important equipment are often protected with dual protection systems. A backup protection operates and trips appropriate circuit breaker(s) only if the main protection fails to detect the disturbance presence or miss opening the breakers. This paper proposes a backup protection scheme for detecting and evaluating the disruption severity of voltage and current signals for protecting the synchronous generators. This scheme is based on a numerical technique of correlation applied for the electrical signals to detect and assess the fault situation. Different fault types are experimentally conducted on a motor‐generator set to test the proposed algorithm effectiveness using Data Acquisition Card (DAC) and LABVIEW software. The scheme has proven to be successful for fault detection and assessment. The algorithm has shown high reliability at various faults and operating conditions. Moreover, the practical results reveal that the scheme is able to evaluate the severity degree of disturbances/unbalances, and it is effective and secure considering the acceptable overloading, harmonics and temporary faults in power grids.
- 22 September 2022
- Published by Springer Nature in Wireless Personal Communications
- Vol. 128 (1) , 321-344
Performance Evaluation and Discrimination of AODV and AOMDV VANET Routing Protocols Based on RRSE Technique
- 22 September 2022
- Published by Springer Nature in Wireless Personal Communications
- Vol. 128 (1) , 321-344
Performance Evaluation and Discrimination of AODV and AOMDV VANET Routing Protocols Based on RRSE Technique
- Open Access
- 20 June 2022
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2022 (8) , 798-831
Automatic power factor correction based on Pearson similarity for distribution networks
In this paper, an online algorithm of automatic power factor correction (APFC) for distribution power grids is presented. The algorithm depends on Pearson similarity of voltage and current signals, which can easily be measured locally using voltage and current transformers, respectively. The proposed method not only evaluates the original power factor (PF), but also functions the APFC more quickly. In this work, the compensation index and reactive power compensation can be identified using new mathematical formulas based on the cross‐correlation coefficients calculated between the phase voltage and current signals. Moreover, the coefficients are useful for detecting any abnormal condition. The method performance is examined on a large‐scale network with real parameters’ data, which is simulated using the alternative transient program (ATP) environment, and the proposed algorithm is developed in MATLAB package. Numerous simulation results confirm the APFC relay feasibility, and the unity PF can be achieved. Besides, the proposed algorithm is characterized by its high operating speed, safety and accuracy for PF compensation, where its performance accuracy is greater than 99.7%. The approach offers novel operating/tripping curves based on the correlation coefficients for both power factor correction (PFC) and protection functions. Therefore, it is described with high level of functionality integration, and its security and sensitivity are controllable easily using the correlation settings.
- 20 June 2022
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2022 (8) , 798-831
Open AccessAutomatic power factor correction based on Pearson similarity for distribution networks
In this paper, an online algorithm of automatic power factor correction (APFC) for distribution power grids is presented. The algorithm depends on Pearson similarity of voltage and current signals, which can easily be measured locally using voltage and current transformers, respectively. The proposed method not only evaluates the original power factor (PF), but also functions the APFC more quickly. In this work, the compensation index and reactive power compensation can be identified using new mathematical formulas based on the cross‐correlation coefficients calculated between the phase voltage and current signals. Moreover, the coefficients are useful for detecting any abnormal condition. The method performance is examined on a large‐scale network with real parameters’ data, which is simulated using the alternative transient program (ATP) environment, and the proposed algorithm is developed in MATLAB package. Numerous simulation results confirm the APFC relay feasibility, and the unity PF can be achieved. Besides, the proposed algorithm is characterized by its high operating speed, safety and accuracy for PF compensation, where its performance accuracy is greater than 99.7%. The approach offers novel operating/tripping curves based on the correlation coefficients for both power factor correction (PFC) and protection functions. Therefore, it is described with high level of functionality integration, and its security and sensitivity are controllable easily using the correlation settings.