Soledad Romero Ruiz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Soledad Romero Ruiz has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Eduardo Miranda-Ulloa
National Reference Laboratory for Sexually Transmitted Viruses, National Center for Public Health, Instituto Nacional de Salud. Lima, Peru
4 shared publications - Fany Cardenas
Laboratorio de VTS/VIH-SIDA, Instituto Nacional de Salud, Lima, Perú. Biólogo/a
4 shared publications - Ronal Briceño Espinoza
Instituto Nacional de Salud, Lima-Perú
4 shared publications - Dilan Suárez-Agüero
Laboratorio de Virus de Transmisión Sexual, Unidad de Virología, Instituto Nacional de Salud, Lima, Perú
3 shared publications - Carlos Augusto Yabar
Universidad de San Martín de Porres
2 shared publications - Maribel Acuña Barrios
Instituto Nacional de Salud, Lima-Perú
2 shared publications
Latest Publications
- Open Access
- 28 September 2026
- Published by Instituto Nacional de Salud (Peru) in Revista Peruana de Medicina Experimental Y Salud Pública
- p. 356-63
Rendimiento diagnóstico de un western blot dual para la detección simultánea de anticuerpos anti-HTLV-1 y anti-VIH-1
Esta investigación planteó determinar el rendimiento de un western blot (WB) dual in house para la detección individual y simultánea de anticuerpos anti-HTLV-1 y anti-VIH-1; la tira se diseñó con antígeno HTLV-1 (1,67ug/mm) arriba y VIH-1 (1,34 ug/mm) abajo. Se evaluó el WB dual in house con 260 sueros referentes procedentes de una seroteca: 50 HTLV-1/VIH-1 positivos, 50 VIH-1 positivos, 60 HTLV-1 positivos, 50 negativos y 50 interferentes. La precisión se evaluó en cinco regiones del Perú. Se obtuvo una sensibilidad y especificidad general de 96,3% (IC 95%: 93,0‒99,5) y 100% (IC 95%: 99,5‒100,0), respectivamente. Individualmente, la sensibilidad fue del 94% en coinfectados HTLV-1/VIH-1, 96,7% en HTLV-1 y 98% en VIH-1. La repetibilidad y reproducibilidad fue del 100% en condiciones de 34‒ 3256 m s. n. m., 16,4‒37,9 °C y 42‒95% de humedad relativa. Concluimos que el WB dual in house HTLV-1/VIH-1 presenta alto rendimiento diagnóstico.
- 28 September 2026
- Published by Instituto Nacional de Salud (Peru) in Revista Peruana de Medicina Experimental Y Salud Pública
- p. 356-63
Open AccessRendimiento diagnóstico de un western blot dual para la detección simultánea de anticuerpos anti-HTLV-1 y anti-VIH-1
Esta investigación planteó determinar el rendimiento de un western blot (WB) dual in house para la detección individual y simultánea de anticuerpos anti-HTLV-1 y anti-VIH-1; la tira se diseñó con antígeno HTLV-1 (1,67ug/mm) arriba y VIH-1 (1,34 ug/mm) abajo. Se evaluó el WB dual in house con 260 sueros referentes procedentes de una seroteca: 50 HTLV-1/VIH-1 positivos, 50 VIH-1 positivos, 60 HTLV-1 positivos, 50 negativos y 50 interferentes. La precisión se evaluó en cinco regiones del Perú. Se obtuvo una sensibilidad y especificidad general de 96,3% (IC 95%: 93,0‒99,5) y 100% (IC 95%: 99,5‒100,0), respectivamente. Individualmente, la sensibilidad fue del 94% en coinfectados HTLV-1/VIH-1, 96,7% en HTLV-1 y 98% en VIH-1. La repetibilidad y reproducibilidad fue del 100% en condiciones de 34‒ 3256 m s. n. m., 16,4‒37,9 °C y 42‒95% de humedad relativa. Concluimos que el WB dual in house HTLV-1/VIH-1 presenta alto rendimiento diagnóstico.
- Open Access
- 24 July 2026
- Published by Elsevier in Revista Argentina de Microbiologia
- Vol. 58 (4)
HIV-1 genetic diversity and antiretroviral drug resistance mutations in Peruvian pediatric population
- 24 July 2026
- Published by Elsevier in Revista Argentina de Microbiologia
- Vol. 58 (4)
Open AccessHIV-1 genetic diversity and antiretroviral drug resistance mutations in Peruvian pediatric population
- Open Access
- 16 March 2022
- Published by Instituto de Investigacion en Ciencias Biomedicas in Revista de la Facultad de Medicina Humana
- Vol. 22 (2) , 428-430
Peruvian experience on the human immunodeficiency virus diagnostic flowchart
Mr Editor: The Joint United Nations Program on HIV/AIDS (UNAIDS) proposed as a goal that the countries reach 95-95-95 by the year 2030, in other words, that 95% of people living with HIV (PLH) are diagnosed and of these that 95% receive antiretroviral treatment (ART) and at least 95% have undetectable viral load or viral suppression.
- 16 March 2022
- Published by Instituto de Investigacion en Ciencias Biomedicas in Revista de la Facultad de Medicina Humana
- Vol. 22 (2) , 428-430
Open AccessPeruvian experience on the human immunodeficiency virus diagnostic flowchart
Mr Editor: The Joint United Nations Program on HIV/AIDS (UNAIDS) proposed as a goal that the countries reach 95-95-95 by the year 2030, in other words, that 95% of people living with HIV (PLH) are diagnosed and of these that 95% receive antiretroviral treatment (ART) and at least 95% have undetectable viral load or viral suppression.
- Open Access
- 23 September 2021
- Published by Instituto de Investigacion en Ciencias Biomedicas in Revista de la Facultad de Medicina Humana
- Vol. 21 (4) , 674-681
Standardization and validation of a western blot for the diagnosis of human immunodeficiency virus
Objectives: To standardize and validate a western blot test for the diagnosis of human immunodeficiency virus. Methods: A prospective observational study was carried out during 2017 and 2018. The western blot test was standardized, using the polyacrylamide gel electrophoresis technique with sodium dodecyl sulfate (SDS PAGE), being the nitrocellulose blot strips prepared with an Optimal HIV-1 antigen concentration of 2.71 µg / mm. The western blot was validated in the laboratory against 400 reference samples (300 sera and 100 plasmas): 200 positive and 200 negatives for antibodies against HIV-1, being the reference test the Immunoblot of the Fujirebio brand. Diagnostic performance parameters were estimated using Epidat v3.1 and Excel. Results: Eight important bands of the HIV-1 antigen were identified: p17, p24, p31, p39, gp41, p55, p66, and gp120. According to the Consortium for the normalization of serology for retroviruse, those that were taken as specific diagnostic bands were: p24, p31, gp41, and gp120. The sensitivity, specificity, positive and negative predictive value and validity index against sera were: 96.7%, 96.0%, 96.0%, 96.6%, 96.3%; and against plasmas: 98.0%, 100.0%, 100.0%, 98.0%, 99.0% respectively. No false positives and negatives were found, but some were undetermined. Conclusion: The development of this western blot test with proprietary technology presented similar diagnostic performance to the reference test, without showing cross-reactions, being useful for confirming HIV.
- 23 September 2021
- Published by Instituto de Investigacion en Ciencias Biomedicas in Revista de la Facultad de Medicina Humana
- Vol. 21 (4) , 674-681
Open AccessStandardization and validation of a western blot for the diagnosis of human immunodeficiency virus
Objectives: To standardize and validate a western blot test for the diagnosis of human immunodeficiency virus. Methods: A prospective observational study was carried out during 2017 and 2018. The western blot test was standardized, using the polyacrylamide gel electrophoresis technique with sodium dodecyl sulfate (SDS PAGE), being the nitrocellulose blot strips prepared with an Optimal HIV-1 antigen concentration of 2.71 µg / mm. The western blot was validated in the laboratory against 400 reference samples (300 sera and 100 plasmas): 200 positive and 200 negatives for antibodies against HIV-1, being the reference test the Immunoblot of the Fujirebio brand. Diagnostic performance parameters were estimated using Epidat v3.1 and Excel. Results: Eight important bands of the HIV-1 antigen were identified: p17, p24, p31, p39, gp41, p55, p66, and gp120. According to the Consortium for the normalization of serology for retroviruse, those that were taken as specific diagnostic bands were: p24, p31, gp41, and gp120. The sensitivity, specificity, positive and negative predictive value and validity index against sera were: 96.7%, 96.0%, 96.0%, 96.6%, 96.3%; and against plasmas: 98.0%, 100.0%, 100.0%, 98.0%, 99.0% respectively. No false positives and negatives were found, but some were undetermined. Conclusion: The development of this western blot test with proprietary technology presented similar diagnostic performance to the reference test, without showing cross-reactions, being useful for confirming HIV.
- Open Access
- 18 June 2021
- Published by Instituto de Investigacion en Ciencias Biomedicas in Revista de la Facultad de Medicina Humana
- Vol. 21 (3) , 677-679
Evaluation Of Three Brands Of Rapid Tests Against Blood Samples For The Detection Of Antibodies Against HIV
Does not apply to Letter to the Editor Uno de los factores importantes para disminuir la propagación del virus de inmunodeficiencia humana (VIH) en el Perú, es la accesibilidad del diagnóstico a través de pruebas rápidas (PR), las cuales son aplicadas hasta en las comunidades más alejadas, sin embargo, en el quinquenio 2011 - 2015 los establecimientos de salud adquirieron y usaron más de 10 diferentes marcas, generando confusión en la aplicación de la metodología descrita en los insertos y en consecuencia resultados erróneos (falsos positivos y falsos negativos)
- 18 June 2021
- Published by Instituto de Investigacion en Ciencias Biomedicas in Revista de la Facultad de Medicina Humana
- Vol. 21 (3) , 677-679
Open AccessEvaluation Of Three Brands Of Rapid Tests Against Blood Samples For The Detection Of Antibodies Against HIV
Does not apply to Letter to the Editor Uno de los factores importantes para disminuir la propagación del virus de inmunodeficiencia humana (VIH) en el Perú, es la accesibilidad del diagnóstico a través de pruebas rápidas (PR), las cuales son aplicadas hasta en las comunidades más alejadas, sin embargo, en el quinquenio 2011 - 2015 los establecimientos de salud adquirieron y usaron más de 10 diferentes marcas, generando confusión en la aplicación de la metodología descrita en los insertos y en consecuencia resultados erróneos (falsos positivos y falsos negativos)
- Open Access
- 26 March 2021
- Published by Instituto Nacional de Salud (Peru) in Revista Peruana de Medicina Experimental Y Salud Pública
- Vol. 38 (1) , 77-82
Resistencia transmitida en VIH-1 de pacientes provenientes de nueve departamentos del Perú
El estudio tuvo como objetivo determinar la resistencia transmitida (RT) del virus de la inmunodeficiencia humana (VIH) en pacientes procedentes de nueve departamentos del Perú. Para ello, se realizó un estudio descriptivo en 132 adultos que aceptaron participar mediante un consentimiento informado. Se colectaron muestras de sangre para realizar el recuento de células CD4/CD8, determinar la carga viral y la genotipificación del VIH. Se recabó información socioepidemiológica de los participantes mediante encuestas. Los resultados revelaron una frecuencia de RT de 9,8% (13/132). Los resultados del estudio ayudarán a mejorar los programas de intervención y monitoreo de la resistencia a los antirretrovirales en el país.
- 26 March 2021
- Published by Instituto Nacional de Salud (Peru) in Revista Peruana de Medicina Experimental Y Salud Pública
- Vol. 38 (1) , 77-82
Open AccessResistencia transmitida en VIH-1 de pacientes provenientes de nueve departamentos del Perú
El estudio tuvo como objetivo determinar la resistencia transmitida (RT) del virus de la inmunodeficiencia humana (VIH) en pacientes procedentes de nueve departamentos del Perú. Para ello, se realizó un estudio descriptivo en 132 adultos que aceptaron participar mediante un consentimiento informado. Se colectaron muestras de sangre para realizar el recuento de células CD4/CD8, determinar la carga viral y la genotipificación del VIH. Se recabó información socioepidemiológica de los participantes mediante encuestas. Los resultados revelaron una frecuencia de RT de 9,8% (13/132). Los resultados del estudio ayudarán a mejorar los programas de intervención y monitoreo de la resistencia a los antirretrovirales en el país.