Yaqi Deng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yaqi Deng has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Hongchun Shu
3 shared publicationsPulin Cao
3 shared publicationsMengmeng Zhu
2 shared publications- Biao Tang
Electric Power Research Institute of Yunnan Power Grid Co., Ltd., Kunming 650200, China
1 shared publication - Bo Yang
Faculty of Electric Power Engineering, Kunming University of Science and Technology, Kunming 650500, China
1 shared publication - Fang Zeng
Faculty of Electric Power Engineering, Kunming University of Science and Technology, Kunming 650500, China
1 shared publication
Latest Publications
- Open Access
- 7 November 2025
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 172
Time-domain fault location method for wind farm double-circuit lines based on circumfluence component
- 7 November 2025
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 172
Open AccessTime-domain fault location method for wind farm double-circuit lines based on circumfluence component
- Open Access
- 5 February 2024
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 157
Transient pilot protection based on directional traveling wave principle for wind power transmission line
- 5 February 2024
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 157
Open AccessTransient pilot protection based on directional traveling wave principle for wind power transmission line
- Open Access
Field Test Method and Equivalence Analysis of Delay Characteristics of DC Electronic Current Transformer
DC electronic current transformer is the data source of the system control and protection device, so its measurement delay has always been concerned. In this paper, the DC current transformer is modelled equivalently and the key factors affecting the delay of shunt and the remote module are analyzed. A field test method for the delay characteristics of the DC electronic current transformer is proposed. Moreover, a complex multi-state large current generator and integrated test system are developed. On the basis of the IEC 60044-8 standard transmission protocol, the accuracy of standard signal acquisition with the shunt is better than 0.2%. The maximum output current of the established testing system is 600 A. Based on the field test in an actual HVDC project, transient step and various frequency signal components are applied for analyzing.
Open AccessField Test Method and Equivalence Analysis of Delay Characteristics of DC Electronic Current Transformer
DC electronic current transformer is the data source of the system control and protection device, so its measurement delay has always been concerned. In this paper, the DC current transformer is modelled equivalently and the key factors affecting the delay of shunt and the remote module are analyzed. A field test method for the delay characteristics of the DC electronic current transformer is proposed. Moreover, a complex multi-state large current generator and integrated test system are developed. On the basis of the IEC 60044-8 standard transmission protocol, the accuracy of standard signal acquisition with the shunt is better than 0.2%. The maximum output current of the established testing system is 600 A. Based on the field test in an actual HVDC project, transient step and various frequency signal components are applied for analyzing.
- 11 May 2021
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 31 (8) , e12926
A detection method of high impedance arcing fault for distribution network with distributed generation based on CEEMDAN and TEO algorithm
The vigorous development of renewable energy has induced multiple sources connected to regional distribution networks. However, the high impedance ground fault that appeared in the distribution network can induce an intermittent arc accompanied by extinction and reignition, which may damage renewable energy generation devices severely. Therefore, the detection of arcing faults is profoundly necessary for practice, but the high impedance arcing fault is easily confused with switches of motor or capacitor bank. In order to solve high impedance arcing fault detection, this paper proposes a high impedance arcing fault detection method that combines complete ensemble empirical mode decomposition with adaptive noise (CEEMDAN) and Teager energy operator (TEO). Firstly, CEEMDAN algorithm is used to extract the intrinsic mode function (IMF) of transient zero‐sequence current (TZSC). According to the correlation coefficient and waveform similarity, which can select maximum correlation coefficient value as the characteristic component of TZSC; Then, TEO is utilized to track the change of signal in real‐time, meanwhile, wavelet singular entropy (WSE) is applied to calculate the characteristic component of TZSC. In particular, high impedance arcing fault (HIAF), motor switching (MS), and capacitor bank switching (CBS) can be effectively identified by comparing WSE. The effectiveness of CEEMDAN‐TEO detection method is verified by simulation, which owns advantages in extraction accuracy, calculation efficiency, and detection accuracy of feature components.
- 11 May 2021
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 31 (8) , e12926
A detection method of high impedance arcing fault for distribution network with distributed generation based on CEEMDAN and TEO algorithm
The vigorous development of renewable energy has induced multiple sources connected to regional distribution networks. However, the high impedance ground fault that appeared in the distribution network can induce an intermittent arc accompanied by extinction and reignition, which may damage renewable energy generation devices severely. Therefore, the detection of arcing faults is profoundly necessary for practice, but the high impedance arcing fault is easily confused with switches of motor or capacitor bank. In order to solve high impedance arcing fault detection, this paper proposes a high impedance arcing fault detection method that combines complete ensemble empirical mode decomposition with adaptive noise (CEEMDAN) and Teager energy operator (TEO). Firstly, CEEMDAN algorithm is used to extract the intrinsic mode function (IMF) of transient zero‐sequence current (TZSC). According to the correlation coefficient and waveform similarity, which can select maximum correlation coefficient value as the characteristic component of TZSC; Then, TEO is utilized to track the change of signal in real‐time, meanwhile, wavelet singular entropy (WSE) is applied to calculate the characteristic component of TZSC. In particular, high impedance arcing fault (HIAF), motor switching (MS), and capacitor bank switching (CBS) can be effectively identified by comparing WSE. The effectiveness of CEEMDAN‐TEO detection method is verified by simulation, which owns advantages in extraction accuracy, calculation efficiency, and detection accuracy of feature components.