George Morgan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
George Morgan has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Spyros D. Masouros
Department of Bioengineering, Imperial College London, UK
2 shared publications Abdelrahman Haweet
1 shared publicationAdam D. Celiz
Department of Bioengineering, Imperial College London, London SW7 2AZ, UK; The Francis Crick Institute , London NW1 1AT, UK
1 shared publication- Alessia Candeo
Politecnico di Milano
1 shared publication Amelie Daudet
Department of Bioengineering, Imperial College London , London SW7 2AZ, UK
1 shared publication- Arul Ramasamy
Centre for Injury Studies, Imperial College London, London, UK
1 shared publication
Latest Publications
- Open Access
- 8 April 2026
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 148 (6) , 1-29
Excessive Shear Rate, Not Shear Stress, Influences Cell Mechanical Damage in Small-Bore Needle Injections
Cell therapies and 3D bioprinting often require suspended cells to be delivered through needles of 20-gauge and smaller. This often damages cells, affecting their short and long-term viability. Most researchers have attributed this to excessive viscous stresses encountered entering or within the needle, but the experimental evidence contradicts that, as higher viscosity suspension fluids generally yield higher cell viabilities when injected at the same flow rate. We therefore sought to determine the most relevant fluid flow parameter influencing cell mechanical damage. A combination of reprocessing published results and cell injection experiments were conducted. Human umbilical vein endothelial cells (HUVECs) were suspended in Newtonian fluids of varying viscosities and injected through 30-gauge syringe needles in experiments that controlled for either shear stress or shear rate (a kinematic quantity expressing relative velocity of adjacent fluid layers). Based on evidence from injection experiments using a variety of fluids, it is shown that increasing shear rate better explains reductions in cell viability than increasing shear stress. Knowledge that shear rate is a more relevant fluid mechanical parameter governing mechanical damage provides a rational basis for designing injection protocols (injectors and suspension fluid rheological properties) to maximize cell viability.
- 8 April 2026
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 148 (6) , 1-29
Open AccessExcessive Shear Rate, Not Shear Stress, Influences Cell Mechanical Damage in Small-Bore Needle Injections
Cell therapies and 3D bioprinting often require suspended cells to be delivered through needles of 20-gauge and smaller. This often damages cells, affecting their short and long-term viability. Most researchers have attributed this to excessive viscous stresses encountered entering or within the needle, but the experimental evidence contradicts that, as higher viscosity suspension fluids generally yield higher cell viabilities when injected at the same flow rate. We therefore sought to determine the most relevant fluid flow parameter influencing cell mechanical damage. A combination of reprocessing published results and cell injection experiments were conducted. Human umbilical vein endothelial cells (HUVECs) were suspended in Newtonian fluids of varying viscosities and injected through 30-gauge syringe needles in experiments that controlled for either shear stress or shear rate (a kinematic quantity expressing relative velocity of adjacent fluid layers). Based on evidence from injection experiments using a variety of fluids, it is shown that increasing shear rate better explains reductions in cell viability than increasing shear stress. Knowledge that shear rate is a more relevant fluid mechanical parameter governing mechanical damage provides a rational basis for designing injection protocols (injectors and suspension fluid rheological properties) to maximize cell viability.
- Open Access
- 2 March 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (3) , e0341618
Evaluation of peripheral intravenous line securement devices under clinically relevant loading and perspiratory conditions
Peripheral vascular access devices (PVADs) and their associated intravenous (IV) lines are widely used in clinical care. Securement devices are typically employed to prevent accidental dislodgement and complications such as occlusion and phlebitis. Despite the wide use of securement devices, there are no standardised methods for evaluating their actual ability to secure IV lines. This study assessed the securing ability of four commercially available IV line securement devices – Grip Lok, Javelo, micropore tape, and IV bracelet – under controlled laboratory conditions. First, all four devices were tested for resistance to axial pull-out forces using a uniaxial materials testing machine across ten participants. Participant comfort during testing was assessed via questionnaire. Grip-Lok and Javelo exhibited significantly greater axial pull-out strength than the other two devices (p-adj < 0.001), and were progressed to further testing, consisting of off-axis loading at 90°, 135°, and peel-off, and axial pull-out under simulated perspiration conditions. No significant differences were observed between Grip Lok and Javelo under loading in 90° and 135°. Javelo demonstrated superior performance in both peel-off and perspirant conditions (p-adj < 0.05). Javelo was rated the most comfortable by 60% of participants. The results highlight the need for incorporating realistic loading conditions and comfort metrics when evaluating the performance of infusion line securement aids. Furthermore, the results provide evidence that using a non-adhesive based device, particularly in patients with marked diaphoresis might provide more infusion line security, though further study is required.
- 2 March 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (3) , e0341618
Open AccessEvaluation of peripheral intravenous line securement devices under clinically relevant loading and perspiratory conditions
Peripheral vascular access devices (PVADs) and their associated intravenous (IV) lines are widely used in clinical care. Securement devices are typically employed to prevent accidental dislodgement and complications such as occlusion and phlebitis. Despite the wide use of securement devices, there are no standardised methods for evaluating their actual ability to secure IV lines. This study assessed the securing ability of four commercially available IV line securement devices – Grip Lok, Javelo, micropore tape, and IV bracelet – under controlled laboratory conditions. First, all four devices were tested for resistance to axial pull-out forces using a uniaxial materials testing machine across ten participants. Participant comfort during testing was assessed via questionnaire. Grip-Lok and Javelo exhibited significantly greater axial pull-out strength than the other two devices (p-adj < 0.001), and were progressed to further testing, consisting of off-axis loading at 90°, 135°, and peel-off, and axial pull-out under simulated perspiration conditions. No significant differences were observed between Grip Lok and Javelo under loading in 90° and 135°. Javelo demonstrated superior performance in both peel-off and perspirant conditions (p-adj < 0.05). Javelo was rated the most comfortable by 60% of participants. The results highlight the need for incorporating realistic loading conditions and comfort metrics when evaluating the performance of infusion line securement aids. Furthermore, the results provide evidence that using a non-adhesive based device, particularly in patients with marked diaphoresis might provide more infusion line security, though further study is required.
- Open Access
- 15 April 2025
- Published by BMJ in BMJ Military Health
- Vol. 172 (4) , 348-352
Assessment of proprietary and improvised pelvic binders: time to application and displacement during casualty evacuation
Introduction: Pelvic injuries resulting from high-energy trauma have an approximately 10% mortality rate. Suspected pelvic injuries are treated with pelvic binders to stabilise fractured bones and promote tamponade until surgical treatment. The effectiveness of pelvic binders in reducing mortality risk depends on accurate positioning of the binder. This study quantifies the ability of proprietary and improvised pelvic binders to maintain their positioning during a simulated casualty evacuation. Methods: One improvised and three proprietary pelvic binders were tested in their ability to maintain their initial placement. Combat Medical Technicians applied binders to healthy subjects and then performed a simulated casualty evacuation. The time taken to apply each binder was measured. The evacuation consisted of: 20 m casualty drag, transfer onto a soft stretcher, 100 m evacuation on a soft stretcher, transfer onto a rigid stretcher and transfer into a field ambulance. Binder placement was measured using bony landmarks after the initial positioning and after each phase of the simulated casualty evacuation. Results: The field-expedient pelvic splint (FEPS), SAM Pelvic Sling II (SAM) and T-POD Pelvic Stabilisation Device (TPOD) all remained within 45 mm of vertical displacement from their initial placement, which is considered an acceptable range for optimal binder functionality. The Prometheus Pelvic Splint (PROM) fell within this range in 83% of trials. The SAM was the fastest binder to apply, followed by the TPOD, and then the FEPS and PROM which took similar times to apply. Conclusions: Binders were mostly able to maintain their positioning during the simulated casualty evacuations carried out in this study but differed in their application times. The improvised binder (FEPS) performed comparably to the proprietary binders tested, and its low cost and weight make it a good alternative to proprietary binders in the austere environment.
- 15 April 2025
- Published by BMJ in BMJ Military Health
- Vol. 172 (4) , 348-352
Open AccessAssessment of proprietary and improvised pelvic binders: time to application and displacement during casualty evacuation
Introduction: Pelvic injuries resulting from high-energy trauma have an approximately 10% mortality rate. Suspected pelvic injuries are treated with pelvic binders to stabilise fractured bones and promote tamponade until surgical treatment. The effectiveness of pelvic binders in reducing mortality risk depends on accurate positioning of the binder. This study quantifies the ability of proprietary and improvised pelvic binders to maintain their positioning during a simulated casualty evacuation. Methods: One improvised and three proprietary pelvic binders were tested in their ability to maintain their initial placement. Combat Medical Technicians applied binders to healthy subjects and then performed a simulated casualty evacuation. The time taken to apply each binder was measured. The evacuation consisted of: 20 m casualty drag, transfer onto a soft stretcher, 100 m evacuation on a soft stretcher, transfer onto a rigid stretcher and transfer into a field ambulance. Binder placement was measured using bony landmarks after the initial positioning and after each phase of the simulated casualty evacuation. Results: The field-expedient pelvic splint (FEPS), SAM Pelvic Sling II (SAM) and T-POD Pelvic Stabilisation Device (TPOD) all remained within 45 mm of vertical displacement from their initial placement, which is considered an acceptable range for optimal binder functionality. The Prometheus Pelvic Splint (PROM) fell within this range in 83% of trials. The SAM was the fastest binder to apply, followed by the TPOD, and then the FEPS and PROM which took similar times to apply. Conclusions: Binders were mostly able to maintain their positioning during the simulated casualty evacuations carried out in this study but differed in their application times. The improvised binder (FEPS) performed comparably to the proprietary binders tested, and its low cost and weight make it a good alternative to proprietary binders in the austere environment.
- Open Access
- 2 October 2023
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 11, 1229388
Quantifying internal intervertebral disc strains to assess nucleus replacement device designs: a digital volume correlation and ultra-high-resolution MRI study
Introduction: Nucleus replacement has been proposed as a treatment to restore biomechanics and relieve pain in degenerate intervertebral discs (IVDs). Multiple nucleus replacement devices (NRDs) have been developed, however, none are currently used routinely in clinic. A better understanding of the interactions between NRDs and surrounding tissues may provide insight into the causes of implant failure and provide target properties for future NRD designs. The aim of this study was to non-invasively quantify 3D strains within the IVD through three stages of nucleus replacement surgery: intact, post-nuclectomy, and post-treatment.Methods: Digital volume correlation (DVC) combined with 9.4T MRI was used to measure strains in seven human cadaveric specimens (42 ± 18 years) when axially compressed to 1 kN. Nucleus material was removed from each specimen creating a cavity that was filled with a hydrogel-based NRD.Results: Nucleus removal led to loss of disc height (12.6 ± 4.4%, p = 0.004) which was restored post-treatment (within 5.3 ± 3.1% of the intact state, p > 0.05). Nuclectomy led to increased circumferential strains in the lateral annulus region compared to the intact state (−4.0 ± 3.4% vs. 1.7 ± 6.0%, p = 0.013), and increased maximum shear strains in the posterior annulus region (14.6 ± 1.7% vs. 19.4 ± 2.6%, p = 0.021). In both cases, the NRD was able to restore these strain values to their intact levels (p ≥ 0.192).Discussion: The ability of the NRD to restore IVD biomechanics and some strain types to intact state levels supports nucleus replacement surgery as a viable treatment option. The DVC-MRI method used in the present study could serve as a useful tool to assess future NRD designs to help improve performance in future clinical trials.
- 2 October 2023
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 11, 1229388
Open AccessQuantifying internal intervertebral disc strains to assess nucleus replacement device designs: a digital volume correlation and ultra-high-resolution MRI study
Introduction: Nucleus replacement has been proposed as a treatment to restore biomechanics and relieve pain in degenerate intervertebral discs (IVDs). Multiple nucleus replacement devices (NRDs) have been developed, however, none are currently used routinely in clinic. A better understanding of the interactions between NRDs and surrounding tissues may provide insight into the causes of implant failure and provide target properties for future NRD designs. The aim of this study was to non-invasively quantify 3D strains within the IVD through three stages of nucleus replacement surgery: intact, post-nuclectomy, and post-treatment.Methods: Digital volume correlation (DVC) combined with 9.4T MRI was used to measure strains in seven human cadaveric specimens (42 ± 18 years) when axially compressed to 1 kN. Nucleus material was removed from each specimen creating a cavity that was filled with a hydrogel-based NRD.Results: Nucleus removal led to loss of disc height (12.6 ± 4.4%, p = 0.004) which was restored post-treatment (within 5.3 ± 3.1% of the intact state, p > 0.05). Nuclectomy led to increased circumferential strains in the lateral annulus region compared to the intact state (−4.0 ± 3.4% vs. 1.7 ± 6.0%, p = 0.013), and increased maximum shear strains in the posterior annulus region (14.6 ± 1.7% vs. 19.4 ± 2.6%, p = 0.021). In both cases, the NRD was able to restore these strain values to their intact levels (p ≥ 0.192).Discussion: The ability of the NRD to restore IVD biomechanics and some strain types to intact state levels supports nucleus replacement surgery as a viable treatment option. The DVC-MRI method used in the present study could serve as a useful tool to assess future NRD designs to help improve performance in future clinical trials.
- Open Access
- 1 August 2021
- Published by Elsevier in Bioprinting
- Vol. 23
Real-time imaging and analysis of cell-hydrogel interplay within an extrusion-bioprinting capillary
- 1 August 2021
- Published by Elsevier in Bioprinting
- Vol. 23
Open AccessReal-time imaging and analysis of cell-hydrogel interplay within an extrusion-bioprinting capillary