XLXing Liu

Xing Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xing Liu has a total of 53 co-authors. Here are the top co-authors by number of shared publications:

  • Zhenli Zhu

    State Key Laboratory of Geomicrobiology and Environmental Changes, China University of Geosciences, Wuhan, 430078, China.

    14 shared publications
  • Hongtao Zheng

    Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China

    13 shared publications
  • Linjie Chen

    State Key Laboratory of Geomicrobiology and Environmental Changes

    6 shared publications
  • Shenghong Hu

    State Key Laboratory of Biogeology and Environmental Geology, China University of Geosciences, Wuhan, Hubei, 430074, China

    6 shared publications
  • Dong He

    4 shared publications
  • Guan Wang

    State Key Laboratory of Geomicrobiology and Environmental Changes, China University of Geosciences, Wuhan, 430078, China

    4 shared publications

Latest Publications

  • Reagent-free atomic fluorescence spectrometry determination of trace cadmium enabled by micro-ultrasonic nebulization

    by Miaomiao Jiang, Junhang Dong, Xiaofang Wang, Xing Liu, Yuqiu Ke, Yixiao Li, Hongtao Zheng, Zhenli Zhu

    Reagent-free micro-ultrasonic nebulization enables efficient aerosol introduction for rapid cadmium determination by atomic fluorescence spectrometry.

  • Development of a Hydraulic-Drive Automatic Column Chromatography System for High Precision Isotope Analysis

    by Wenkai Zhang, Qilong Li, Yingran Liang, Linjie Chen, Nicholas Stanley Belshaw, Zhuo Cheng, Chaoxiang Zhang, Xing Liu, Hongtao Zheng, Fangran Zhao, et al.

    This study presents a high-throughput automated open-column chromatography system designed for high-precision isotope analysis based on a hydraulic remote-drive mechanism. The system operates by using pressurized fluid to indirectly control eluent delivery, resulting in a completely metal-free separation unit that fully isolates metal components (pump, sensor, and valve) from corrosive acid solutions and vapors. This design effectively eliminates the corrosion and contamination risks inherent to conventional systems. Coupled with pressure sensing and mass flow feedback control, the hydraulic drive enables multichannel parallel elution (currently 8 channels) with high accuracy (error <3%) and excellent interchannel consistency (variation <0.5%). Constructed primarily from low-cost polymers, the system offers an economical and scalable platform for automated sample preparation. Validation using Cd and Cu isotope separation protocols demonstrated high recoveries (Cd: 97.5 ± 1.6%; Cu: 98.3 ± 1.4%) and low procedural blanks (Cd: 0.17 ng; Cu: 0.72 ng). Analysis of geological reference materials (e.g., BHVO-2, BCR-2, NOD-P-1) yielded isotopic ratios consistent with published values, confirming method reliability. Overall, the system provides a scalable, cost-effective, and metal-free platform for high-throughput separations required for high-precision isotope analysis.

  • Open Access

    Extreme mass-independent fractionation of mercury isotopes driven by atmospheric plasma-induced chemical process

    by Xing Liu, Guan Wang, Yuzhe Wang, Wang Zheng, Hongtao Zheng, Pengju Xing, Zhenli Zhu

    Mass-independent fractionation (MIF) of mercury (Hg) provides a powerful tracer for reconstructing Hg cycling in the Earth system. Although generally attributed to photochemistry, many natural isotope signatures remain inconsistent with the established mechanisms. Here, we present experimental evidence that atmospheric plasma-induced reduction produces odd Hg-MIF with magnitudes and patterns distinct from photochemical processes. Plasma reactions yielded far larger odd-MIF signatures than photoreduction, with Δ199Hg spanning -78‰ to +28‰, the most negative Hg-MIF across all Hg-reduction experiments. The sign of Hg-MIF reverses with solution pH, yielding strongly negative Hg-MIF at pH ≥ 3.0 but positive Hg-MIF at pH ≤ 2.0. This reversal arises from competition between plasma-generated species, where solvated electrons drive negative magnetic isotope effects (MIE) at higher pH, while hydrogen radicals produce positive MIE at low pH. These findings reveal plasma chemistry as a fundamental but previously overlooked driver of Hg isotope fractionation. Given the ubiquity of natural plasmas such as lightning and aurora, plasma processes need to be integrated into models of Hg cycling in Earth's atmosphere and surface environments.

  • Hydride Generation-Based Purification Method for High-Precision Antimony Isotopic Analysis in Low-Concentration and Complex-Matrix Samples

    by Shuyang Li, Junhang Dong, Linjie Chen, Xing Liu, Yang Yu, Hongtao Zheng, Zhaochu Hu, Zhenli Zhu

    Antimony (Sb) isotopes have emerged as a powerful tool for tracing Sb sources and understanding their geochemical behavior in different systems. However, accurate and precise determination of Sb isotopic compositions (δ123Sb) in natural samples remains a challenge, especially in low-concentration samples with complex matrices. In this study, we introduce a novel two-step purification method for high-precision Sb isotope analysis. In the first step, hydride generation (HG) is employed to effectively isolate Sb from major elements, followed by further purification with a thiol silica column. After optimization, two distinct HG purification modes were established: a flow mode for water samples and a no-flow mode for solid geological samples. Our method achieved complete Sb purification recovery with effective removal of matrix elements and the procedure blank was under the detection limits (123Sb values in excellent agreement with the reference data, confirming that no isotopic fractionation occurred during the HG purification. Finally, we successfully applied this technique to a range of low-Sb environmental samples, including river, seawater, and sediments, demonstrating its effectiveness in accurate and precise Sb isotopic analysis. Overall, this novel method offers a rapid and efficient purification strategy for high-precision Sb isotopic analysis, thereby enhancing our ability to investigate Sb isotopic reservoirs associated with biogeochemical cycles.


  • Species-specific Antimony Isotope Analysis by High Performance Liquid Chromatography Coupled with Multicollector ICPMS Using Hydride Generation as an Interface

    by Linjie Chen, Yuanyuan Du, Shuyang Li, Xing Liu, Jun Shen, Zhenli Zhu

    A novel method has been developed for the simultaneous online determination of the isotopic compositions of different antimony (Sb) species in a single analytical run using high-performance liquid chromatography (HPLC) coupled with multicollector inductively coupled plasma mass spectrometry (MC-ICPMS), with hydride generation (HG) serving as the interface. Various parameters affecting the precision of Sb isotope analysis including HG conditions, transient signal processing methods and peak integration windows, were optimized. The linear regression slope method and a 100% peak integration window provided the optimal precision. Under optimized conditions, our method achieved external 2SD precisions better than 0.05‰ for both Sb(III) and Sb(V), with minimal consumption of 0.5 ng for Sb(III) and 5 ng for Sb(V). Furthermore, flow injection (FI) coupled with HG-MC-ICPMS demonstrated precise Sb isotopic analysis with sample requirements as low as 0.25 ng. The proposed methods were validated by analyzing δ123Sb in synthetic solutions and reference materials. Additionally, it was applied to investigate isotopic fractionation during the reduction of Sb(V) by KI, revealing preferential reduction of the light Sb isotope(121Sb). The isotopic compositions of Sb(V) varied from -0.04- 1.18‰, fitting well with a Rayleigh fractionation model and yielding a fractionation factor (αSb(III)-Sb(V)) of 0.99831. In summary, this approach enables high precision isotopic analysis of Sb(III) and Sb(V) simultaneously with reduced sample consumption, providing a powerful tool for investigating Sb isotopic fractionation in various environmental processes and advancing our understanding of the Sb biogeochemical cycle.


  • Low-Consumption and High-Efficiency Isotope Analysis by Microultrasonic Single-Droplet Nebulization Sampling Multicollector Inductively Coupled Plasma Mass Spectrometry

    by Junhang Dong, Yang Yu, Zhujun Dai, Shuyang Li, Linjie Chen, Pengju Xing, Guan Wang, Xing Liu, Hongtao Zheng, Zhenli Zhu

    Metal stable isotopes are increasingly applied in various fields, including planetary science and medical research, highlighting the need for isotope analysis methods capable of handling precious and microvolume samples. This study introduces a novel, low-consumption, high-efficiency isotope analysis method using MC-ICP-MS based on microultrasonic single-droplet nebulization (MUSDN). The proposed MUSDN enables the complete nebulization of microliter-sized droplets, delivering high-sensitivity transient analytical signals with a duration of several seconds. Under optimized conditions, MUSDN exhibited significantly enhanced sensitivity compared to conventional pneumatic nebulization, achieving 17-fold and 12-fold improvements for 7Li and 63Cu, respectively. The achieved external precisions (2SD) for δ7Li and δ65Cu were 0.3 and 0.08‰, with single analysis consuming only 1 ng of Li and 2 ng of Cu, respectively. This represents a reduction in sample consumption by 1-2 orders of magnitude compared to conventional PN-MC-ICP-MS while also improving the analysis speed by at least 10-fold due to rapid residual washout. Furthermore, our method demonstrated superior δ65Cu analytical precision compared to other high-sensitivity transient analysis methods (0.19‰ with a laser ablation system) with similar sample consumption. Finally, the accuracy of the proposed method was validated through the analysis of geological CRMs, serum CRMs, in-house standard samples, and a series of real serum samples. This novel isotope analysis method provides a promising approach for isotope applications involving precious and microvolume samples.


  • Variations in antimony isotope and toxic metals across the Guadalupian-Lopingian (Permian) boundary at Penglaitan, China: Implications for the Emeishan volcanism and marine extinction

    by Shuyang Li, Yuangeng Huang, Zhong-Qiang Chen, Linjie Chen, Paul B. Wignall, Junhang Dong, Xing Liu, Hongtao Zheng, Guan Wang, Zhensheng Wei, et al.


  • High-Efficiency Miniaturized Ultrasonic Nebulization Sample Introduction System for Elemental Analysis of Microvolume Biological Samples by Inductively Coupled Plasma Quadrupole Mass Spectrometry

    by Junhang Dong, Jinzhao Liu, Pengju Xing, Shuyang Li, Jinsheng Piao, Huifang Tao, Lujie Li, Hongtao Zheng, Zhe Zhang, Shanru Han, et al.

    Sensitive and high-throughput analysis of trace elements in volume-limited biological samples is highly desirable for clinical research and health risk assessments. However, the conventional pneumatic nebulization (PN) sample introduction is usually inefficient and not well-suited for this requirement. Herein, a novel high-efficiency (nearly 100% sample introduction efficiency) and low-sample-consumption introduction device was developed and successfully coupled with inductively coupled plasma quadrupole mass spectrometry (ICP-QMS). It consists of a micro-ultrasonic nebulization (MUN) component with an adjustable nebulization rate and a no-waste spray chamber designed based on fluid simulation. The proposed MUN-ICP-QMS could achieve sensitive analysis at a low sampling rate of 10 μL min-1 with an extremely low oxide ratio of 0.25% where the sensitivity is even higher comparing to PN (100 μL min-1). The characterization results indicate that the higher sensitivity of MUN is attributed to the smaller aerosol size, higher aerosol transmission efficiency, and improved ion extraction. In addition, it offers a fast washout (20 s) and reduced sample consumption (as low as 7 μL). The absolute LODs of the studied 26 elements by MUN-ICP-QMS are improved by 1-2 orders of magnitude compared with PN-ICP-QMS. The accuracy of the proposed method was validated by the analysis of human serum, urine, and food-related certified reference materials. Furthermore, preliminary results of serum samples from patients with mental illnesses demonstrated its potential in the field of metallomics.


  • Fast and highly sensitive Cd isotopic analyses in low-Cd complex samples with MC-ICPMS based on plasma electrochemical vapor generation

    by Xing Liu, Linjie Chen, Huan Peng, Guan Wang, Nicholas Stanley Belshaw, Hongtao Zheng, Shenghong Hu, Zhenli Zhu


  • Electrothermal Desolvation-Enhanced Dielectric Barrier Discharge Plasma-Induced Vapor Generation for Sensitive Determination of Antimony by Atomic Fluorescence Spectrometry

    by Xing Liu, Guo Cheng, Chun Yang, Hong-Tao Zheng, Sheng-Hong Hu, Zhen-Li Zhu

    A novel simple electrothermal desolvation-enhanced dielectric barrier discharge plasma-induced vapor generation (ETD-DBD-PIVG) method has been developed for sensitive Sb determination by atomic fluorescence spectrometry (AFS). In our proposed ETD-DBD-PIVG, 20 μL sample solution was dried first; then, the resulting solution residue was directly converted into molecular volatile species efficiently through the interactions with hydrogen-doped DBD plasma; and finally, it was transported to AFS for detection. It was found that the desolvation process could greatly enhance Sb vapor generation, and the Sb fluorescence signal intensity is almost independent of its speciation, where comparable sensitivity is achieved for Sb(III) and Sb(V), enabling efficient total Sb detection without pre-reduction. Influencing parameters were evaluated in detail, including heating time, discharge gap, solution pH, and flow rates of argon and hydrogen, as well as coexisting ion interference. Under optimized conditions, the limit of detection was calculated as 0.86 μg L–1 (17.2 pg) for Sb. The accuracy of the proposed method was validated by the analysis of certified reference materials of simulated natural water samples and several river water samples. Compared with conventional hydride generation, the new ETD-DBD-PIVG offers an alternative green vapor generation technique with several advantages: (1) it eliminates the use of a sample flow system (e.g., no use of any syringe or peristaltic pump); instead, 20 μL of a sample is directly pipetted onto the glass plate for analysis; (2) it greatly simplifies the sample pretreatment steps as no pre-reduction process is needed; (3) it is sensitive and suitable for volume-limited sample analysis: efficient Sb vapor generation without chemical reducing reagents in ETD-DBD-PIVG enables Sb detection with an absolute limit at the picogram level. All the results demonstrate that the proposed method provides a simple, green, and sensitive method for Sb determination and it can also be extended to other elements such as Cd and As.