IMIan McLane

Ian McLane

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ian McLane has a total of 56 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Identification of adventitious lung sounds in children with respiratory illnesses in Bangladesh using artificial intelligence and digital auscultation

    by Salahuddin Ahmed, Ahad Mahmud Khan, Harish Nair, Steve Cunningham, Ian Mitra McLane, Md Shafiqul Islam, Asmd Ashraful Islam, Rezwana Tabassum, Nabidul Haque Chowdhury, Nighat Sultana, et al.

  • Open Access

    Performance of an artificial intelligence algorithm for interpreting lung sounds from children hospitalised with pneumonia in Malawi

    by Nadia E Hoekstra, Maganizo B Chagomerana, Zachary H Smith, Annapurna Kala, Ian McLane, Charl Verwey, Daniel Olson, W Chris Buck, Justin Mulindwa, Alex Gaudio, et al.

    Pneumonia remains the leading infectious cause of mortality in children under five worldwide [1,2]. The World Health Organization (WHO) Integrated Management of Childhood Illnesses (IMCI) guidelines provide the current standard for managing paediatric pneumonia in low-income and middle-income countries (LMICs) [3]. Developed in the 1980s, the IMCI algorithm enables non-physician health care workers (HCWs) to […]


  • Open Access

    End-user acceptability of a prototype digital stethoscope to diagnose childhood pneumonia- a qualitative exploration from Sylhet, Bangladesh

    by Taufique Joarder, Samiun Nazrin Bente Kamal Tune, Asmd Ashraful Islam, Arifa Islam, Arunangshu Dutta Roy, Eric D. McCollum, Harish Nair, Steven Cunningham, Ian Mitra McLane, Mohammod Shahidullah, et al.

    Background: Considering the high frequency of respiratory infections among children in low- and middle-income countries (LMICs), the World Health Organization (WHO) developed a pragmatic guideline for managing pneumonia in low-resource settings. The guideline’s low specificity leads to many false-positive pneumonia cases receiving antibiotic treatment. Integrating diagnostic technology to incorporate lung sounds into WHO guidelines could improve childhood pneumonia diagnosis and management. This qualitative study aimed to explore the acceptability of a prototype digital stethoscope device among potential end-users in Bangladesh. Methods: We conducted four focus group discussions (FGDs) with beneficiaries and service providers who used a 2018 digital stethoscope prototype. The data collection was conducted in November 2020. The study was carried out at Zakiganj Upazila (sub-district) of Sylhet district of Bangladesh. A total of 34 respondents, including parents of under-5 children, Community Health Care Providers (CHCPs), and community leaders were enrolled. Two researchers (TJ and a research assistant (not a co-author of this manuscript) conducted the FGDs. Verbatim transcripts were prepared, and translations were completed. Coding was executed in Microsoft Excel, and relevant quotes were extracted to ascertain the emerging themes. To ensure validity, two researchers coded the dataset independently and inconsistencies were resolved through discussion. Findings: Mothers were more aware of the digital stethoscope than fathers. Except for the female community leaders, male leaders were unaware of the stethoscopes. Most CHCPs had positive perceptions of the digital stethoscope. They appreciated stethoscope training as they learned about new technology and diagnostic approaches. The users mentioned several technical shortcomings of the prototype device. A few stakeholders expressed dissatisfaction with the level of community involvement and information sharing from the study. The use of the device plummeted during the COVID-19 pandemic for fear of infection, to counteract which the CHCPs cleaned the device with chlorhexidine after every application as a precaution. Conclusion: Overall, device use was supported by stakeholders despite perceptions that the prototype had some technological limitations, community engagement was suboptimal, and the COVID-19 pandemic caused disruptions. Stronger community engagement, addressing technological issues, and further research on its health systems application would improve the acceptability and effective use of the digital stethoscope.


  • Open Access

    Considerations and Challenges for Real-World Deployment of an Acoustic-Based COVID-19 Screening System

    by Drew Grant, Ian McLane, Valerie Rennoll, James West

    Coronavirus disease 2019 (COVID-19) has led to countless deaths and widespread global disruptions. Acoustic-based artificial intelligence (AI) tools could provide a simple, scalable, and prompt method to screen for COVID-19 using easily acquirable physiological sounds. These systems have been demonstrated previously and have shown promise but lack robust analysis of their deployment in real-world settings when faced with diverse recording equipment, noise environments, and test subjects. The primary aim of this work is to begin to understand the impacts of these real-world deployment challenges on the system performance. Using Mel-Frequency Cepstral Coefficients (MFCC) and RelAtive SpecTrAl-Perceptual Linear Prediction (RASTA-PLP) features extracted from cough, speech, and breathing sounds in a crowdsourced dataset, we present a baseline classification system that obtains an average receiver operating characteristic area under the curve (AUC-ROC) of 0.77 when discriminating between COVID-19 and non-COVID subjects. The classifier performance is then evaluated on four additional datasets, resulting in performance variations between 0.64 and 0.87 AUC-ROC, depending on the sound type. By analyzing subsets of the available recordings, it is noted that the system performance degrades with certain recording devices, noise contamination, and with symptom status. Furthermore, performance degrades when a uniform classification threshold from the training data is subsequently used across all datasets. However, the system performance is robust to confounding factors, such as gender, age group, and the presence of other respiratory conditions. Finally, when analyzing multiple speech recordings from the same subjects, the system achieves promising performance with an AUC-ROC of 0.78, though the classification does appear to be impacted by natural speech variations. Overall, the proposed system, and by extension other acoustic-based diagnostic aids in the literature, could provide comparable accuracy to rapid antigen testing but significant deployment challenges need to be understood and addressed prior to clinical use.


  • Open Access

    Optimized Acoustic Phantom Design for Characterizing Body Sound Sensors

    by Valerie Rennoll, Ian McLane, Mounya Elhilali, James E. West

    Many commercial and prototype devices are available for capturing body sounds that provide important information on the health of the lungs and heart; however, a standardized method to characterize and compare these devices is not agreed upon. Acoustic phantoms are commonly used because they generate repeatable sounds that couple to devices using a material layer that mimics the characteristics of skin. While multiple acoustic phantoms have been presented in literature, it is unclear how design elements, such as the driver type and coupling layer, impact the acoustical characteristics of the phantom and, therefore, the device being measured. Here, a design of experiments approach is used to compare the frequency responses of various phantom constructions. An acoustic phantom that uses a loudspeaker to generate sound and excite a gelatin layer supported by a grid is determined to have a flatter and more uniform frequency response than other possible designs with a sound exciter and plate support. When measured on an optimal acoustic phantom, three devices are shown to have more consistent measurements with added weight and differing positions compared to a non-optimal phantom. Overall, the statistical models developed here provide greater insight into acoustic phantom design for improved device characterization.


  • Comprehensive Analysis System for Automated Respiratory Cycle Segmentation and Crackle Peak Detection

    by Ian Mitra Mclane, Eline Lauwers, Toon Stas, Ilene Busch-Vishniac, Kris Ides, Stijn Verhulst, Jan Steckel

    Digital auscultation is a well-known method for assessing lung sounds, but remains a subjective process in typical practice, relying on the human interpretation. Several methods have been presented for detecting or analyzing crackles but are limited in their real-world application because few have been integrated into comprehensive systems or validated on non-ideal data. This work details a complete signal analysis methodology for analyzing crackles in challenging recordings. The procedure comprises five sequential processing blocks: (1) motion artifact detection, (2) deep learning denoising network, (3) respiratory cycle segmentation, (4) separation of discontinuous adventitious sounds from vesicular sounds, and (5) crackle peak detection. This system uses a collection of new methods and robustness-focused improvements on previous methods to analyze respiratory cycles and crackles therein. To validate the accuracy, the system is tested on a database of 1000 simulated lung sounds with varying levels of motion artifacts, ambient noise, cycle lengths and crackle intensities, in which ground truths are exactly known. The system performs with average F-score of 91.07% for detecting motion artifacts and 94.43% for respiratory cycle extraction, and an overall F-score of 94.08% for detecting the locations of individual crackles. The process also successfully detects healthy recordings. Preliminary validation is also presented on a small set of 20 patient recordings, for which the system performs comparably. These methods provide quantifiable analysis of respiratory sounds to enable clinicians to distinguish between types of crackles, their timing within the respiratory cycle, and the level of occurrence. Crackles are one of the most common abnormal lung sounds, presenting in multiple cardiorespiratory diseases. These features will contribute to a better understanding of disease severity and progression in an objective, simple and non-invasive way.


  • Design and Comparative Performance of a Robust Lung Auscultation System for Noisy Clinical Settings

    by Ian McLane, Dimitra Emmanouilidou, James E West, Mounya Elhilali

    Chest auscultation is a widely used clinical tool for respiratory disease detection. The stethoscope has undergone a number of transformative enhancements since its invention, including the introduction of electronic systems in the last two decades. Nevertheless, stethoscopes remain riddled with a number of issues that limit their signal quality and diagnostic capability, rendering both traditional and electronic stethoscopes unusable in noisy or non-traditional environments (e.g., emergency rooms, rural clinics, ambulatory vehicles). This work outlines the design and validation of an advanced electronic stethoscope that dramatically reduces external noise contamination through hardware redesign and real-time, dynamic signal processing. The proposed system takes advantage of an acoustic sensor array, an external facing microphone, and on-board processing to perform adaptive noise suppression. The proposed system is objectively compared to six commercially-available acoustic and electronic devices in varying levels of simulated noisy clinical settings and quantified using two metrics that reflect perceptual audibility and statistical similarity, normalized covariance measure (NCM) and magnitude squared coherence (MSC). The analyses highlight the major limitations of current stethoscopes and the significant improvements the proposed system makes in challenging settings by minimizing both distortion of lung sounds and contamination by ambient noise.


  • Electronic Stethoscope Filtering Mimics the Perceived Sound Characteristics of Acoustic Stethoscope

    by Valerie Rennoll, Ian McLane, Dimitra Emmanouilidou, James West, Mounya Elhilali

    Electronic stethoscopes offer several advantages over conventional acoustic stethoscopes, including noise reduction, increased amplification, and ability to store and transmit sounds. However, the acoustical characteristics of electronic and acoustic stethoscopes can differ significantly, introducing a barrier for clinicians to transition to electronic stethoscopes. This work proposes a method to process lung sounds recorded by an electronic stethoscope, such that the sounds are perceived to have been captured by an acoustic stethoscope. The proposed method calculates an electronic-to-acoustic stethoscope filter by measuring the difference between the average frequency responses of an acoustic and an electronic stethoscope to multiple lung sounds. To validate the method, a change detection experiment was conducted with 51 medical professionals to compare filtered electronic, unfiltered electronic, and acoustic stethoscope lung sounds. Participants were asked to detect when transitions occurred in sounds comprising several sections of the three types of recordings. Transitions between the filtered electronic and acoustic stethoscope sections were detected, on average, by chance (sensitivity index equal to zero) and also detected significantly less than transitions between the unfiltered electronic and acoustic stethoscope sections (p <; 0.01), demonstrating the effectiveness of the method to filter electronic stethoscopes to mimic an acoustic stethoscope. This processing could incentivize clinicians to adopt electronic stethoscopes by providing a means to shift between the sound characteristics of acoustic and electronic stethoscopes in a single device, allowing for a faster transition to new technology and greater appreciation for the electronic sound quality.