Myriam Koch
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Myriam Koch has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Herbert De Gersem
Institute for Accelerator Science and Electromagnetic Fields, Technical University of Darmstadt, Darmstadt, Germany
2 shared publications - Maren Greta Ruppert
Tehniška univerza v Darmstadtu, Inštitut za znanost o pospeševalnikih in elektromagnetnih poljih (TEMF)
2 shared publications - Yvonne Späck-Leigsnering
Robert Bosch GmbH
2 shared publications - Christian Michael Franck
Institute for Power Systems and High Voltage Technology, ETH Zürich, Physikstrasse 3, 8092 Zürich, Switzerland
1 shared publication - Dominik Viebke
Professorship for High Voltage Engineering and Switchgear Technology, Technical University of Munich, Munich, Germany
1 shared publication - Erion Gjonaj
Institute for Accelerator Science and Electromagnetic Fields (TEMF), TU Darmstadt, Darmstadt, Germany
1 shared publication
Latest Publications
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 54 (10) , 1-8
DC Interruption and Arc Dynamics of Butt, AMF, and TMF Contact Systems in Vacuum Interrupters
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 54 (10) , 1-8
DC Interruption and Arc Dynamics of Butt, AMF, and TMF Contact Systems in Vacuum Interrupters
- Open Access
- 16 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (6) , 3472-3480
Influence of Start Electron Provision Parameters on Breakdown Strength in Pressurized Synthetic Air Under Lightning Impulse Voltage Stress
Future generations of gas-insulated metalenclosed switchgear should be operated with an environmentally friendly alternative insulating gas instead of sulfur hexafluoride. A promising alternative is pressurized synthetic air. To reliably design these systems, it is essential to predict the breakdown probability. For this purpose, the breakdown probability of a weakly nonuniform, polished hemisphere-plate electrode arrangement is evaluated through voltage rise tests. These tests are conducted under negative and positive lightning impulse voltage stress at pressures up to 1.0 MPa and room temperature. Alongside the experiments, a simulation model is developed using the volume-time law to predict the breakdown probability based on the start electron provision. The simulation parameters are empirically adjusted to ensure a high degree of agreement between the measured and calculated breakdown probabilities. This adaptation enables the determination of pressure- and polarity-dependent effects on the field stress enhancement factor, the minimum macroscopic background field strength, and the negative ion density.
- 16 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (6) , 3472-3480
Open AccessInfluence of Start Electron Provision Parameters on Breakdown Strength in Pressurized Synthetic Air Under Lightning Impulse Voltage Stress
Future generations of gas-insulated metalenclosed switchgear should be operated with an environmentally friendly alternative insulating gas instead of sulfur hexafluoride. A promising alternative is pressurized synthetic air. To reliably design these systems, it is essential to predict the breakdown probability. For this purpose, the breakdown probability of a weakly nonuniform, polished hemisphere-plate electrode arrangement is evaluated through voltage rise tests. These tests are conducted under negative and positive lightning impulse voltage stress at pressures up to 1.0 MPa and room temperature. Alongside the experiments, a simulation model is developed using the volume-time law to predict the breakdown probability based on the start electron provision. The simulation parameters are empirically adjusted to ensure a high degree of agreement between the measured and calculated breakdown probabilities. This adaptation enables the determination of pressure- and polarity-dependent effects on the field stress enhancement factor, the minimum macroscopic background field strength, and the negative ion density.
- Open Access
- 14 May 2025
- Published by University of Maribor
- p. 15-20
Dimensioning Field-Grading Materials in Cable Joints by Adjoint Transient Finite-Element Sensitivity Analysis
An adjoint sensitivity analysis of a nonlinear transient finite-element model allows to determine the sensitivities of the key performance indicators of a cable joint with respect to the parameters of an embedded field-grading material. The example considers a high-voltage DC cable joint submitted to an overvoltage event.
- 14 May 2025
- Published by University of Maribor
- p. 15-20
Open AccessDimensioning Field-Grading Materials in Cable Joints by Adjoint Transient Finite-Element Sensitivity Analysis
An adjoint sensitivity analysis of a nonlinear transient finite-element model allows to determine the sensitivities of the key performance indicators of a cable joint with respect to the parameters of an embedded field-grading material. The example considers a high-voltage DC cable joint submitted to an overvoltage event.
- Open Access
Towards Electrothermal Optimization of a HVDC Cable Joint Based on Field Simulation
Extruded high-voltage direct current cable systems transmit electric power over long distances. Numerical field simulation can provide access to the internal electrothermal behavior of cable joints, which interconnect cable sections. However, coupled nonlinear electrothermal field simulations are still a challenge. In this work, a robust numerical solution approach is implemented and validated. This approach allows for efficient parameter studies of resistively graded high-voltage direct current cable joint designs. It is assessed how the dielectric stress distribution between the conductor connection and the grounded cable sheath is influenced by nonlinear field and temperature dependent electric conductivity of the field grading material. Optimal field grading material parameters, which fulfill the field grading and power loss requirements, are suggested based on the simulation studies.
Open AccessTowards Electrothermal Optimization of a HVDC Cable Joint Based on Field Simulation
Extruded high-voltage direct current cable systems transmit electric power over long distances. Numerical field simulation can provide access to the internal electrothermal behavior of cable joints, which interconnect cable sections. However, coupled nonlinear electrothermal field simulations are still a challenge. In this work, a robust numerical solution approach is implemented and validated. This approach allows for efficient parameter studies of resistively graded high-voltage direct current cable joint designs. It is assessed how the dielectric stress distribution between the conductor connection and the grounded cable sheath is influenced by nonlinear field and temperature dependent electric conductivity of the field grading material. Optimal field grading material parameters, which fulfill the field grading and power loss requirements, are suggested based on the simulation studies.
- Open Access
- 1 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 28 (00849162) , 11-14
Inception level of partial discharges in SF6 induced with short X-ray pulses
First generation gas insulated switchgears were constructed with large safety margin. Today's trend is to reduce the size of the switchgears to save material and costs. With increased field strength due to reduced dimensions as well as increased pressure in the compartments, the influence of surface roughness, surface damages and conducting particles is increasing. Therefore the knowledge of the exact inception level of partial discharges due to those imperfections is of interest. The goal of the present contribution is to measure the discharge inception voltage in SF 6 in a homogeneous field configuration with a small protrusion with unprecedented high accuracy. With a short pulse X-ray source first electrons are provided within the critical volume. The experimental results show for a 0.2 MPa SF 6 insulation a threshold voltage of roughly 80 kV for positive and negative polarity at the protrusion, respectively. These inception voltages match the calculated theoretical inception level. The proposed method allows determining the inception voltage in a more efficient way as the experiment time is reduced.
- 1 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 28 (00849162) , 11-14
Open AccessInception level of partial discharges in SF6 induced with short X-ray pulses
First generation gas insulated switchgears were constructed with large safety margin. Today's trend is to reduce the size of the switchgears to save material and costs. With increased field strength due to reduced dimensions as well as increased pressure in the compartments, the influence of surface roughness, surface damages and conducting particles is increasing. Therefore the knowledge of the exact inception level of partial discharges due to those imperfections is of interest. The goal of the present contribution is to measure the discharge inception voltage in SF 6 in a homogeneous field configuration with a small protrusion with unprecedented high accuracy. With a short pulse X-ray source first electrons are provided within the critical volume. The experimental results show for a 0.2 MPa SF 6 insulation a threshold voltage of roughly 80 kV for positive and negative polarity at the protrusion, respectively. These inception voltages match the calculated theoretical inception level. The proposed method allows determining the inception voltage in a more efficient way as the experiment time is reduced.