Dobromir Petkov Dobrev
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dobromir Petkov Dobrev has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Tatyana Dimitrova Neycheva
Institute of Biophysics and Biomedical Engineering, Bulgarian Academy of Sciences, Acad. G. Bonchev Str. Bl 105, 1113 Sofia, Bulgaria
5 shared publications Tatyana D. Neycheva
Institute of Biophysics and Biomedical Engineering, Bulgarian Academy of Sciences Acad., Sofia, Bulgaria
4 shared publicationsTatyana Dimitrova Neycheva
Institute of Biophysics and Biomedical Engineering, Bulgarian Academy of Sciences, Sofia, 1113, Bulgaria
3 shared publicationsEmad Alnasser
NouTronics R&D group, Karaj, Iran
2 shared publicationsNikolay Mudrov
2 shared publicationsTatyana Neycheva
2 shared publications
Latest Publications
- Open Access
- 15 April 2025
- Published by MDPI AG in Technologies
- Vol. 13 (4) , 159
Design of High-Pass and Low-Pass Active Inverse Filters to Compensate for Distortions in RC-Filtered Electrocardiograms
Distortions of electrocardiograms (ECGs) caused by mandatory high-pass and low-pass analog RC filters in ECG devices are always present. The fidelity of the ECG waveform requires limiting the RC cutoff frequencies of the diagnostic (0.05–150 Hz) and monitoring systems (0.5–40 Hz). However, the use of fixed frequency bands is a compromise between enhanced noise immunity and ECG distortions. This study aims to propose active inverse high-pass and low-pass filters which are able to compensate for distortions in digital recordings of RC-filtered ECGs, thereby overcoming the limitations imposed by analog filtering. A new straightforward design of an inverse high-pass filter (IHPF) uses an integrator as the forward-path gain block, with a feedback loop containing an active digital filter equivalent to the analog RC high-pass filter. In contrast, the inverse low-pass filter (ILPF) employs a constant-gain block in the forward path to ensure stability and prevent phase delay, while its feedback path features an active digital counterpart of the RC low-pass filter. Second-order inverse filters are created by cascading two first-order stages. The proposed filters were validated according to essential performance requirements for electrocardiographs. The low-frequency (impulse) responses of IHPFs with cutoff frequencies of 0.05–5 Hz exhibit no overshoot and undershoot by magnitudes of 0.1–25 µV, well within the ±100 µV compliance limit defined for a test rectangular pulse (3 mV, 100 ms). The high-frequency responses of ILPFs with cutoff frequencies of 10–150 Hz present a relative amplitude drop of only 0.2–2.5%, far below the 10% limit for peak amplitude reduction of a triangular pulse (1.5 mV) with 20 ms vs. 200 ms widths. For any of the eight ECG leads (I, II, and V1–V6) available in the standard signal (ANE20000), the IHPF (0.05–5 Hz) presents ST-segment deviations <5 μV (within the ±25 μV limit) and R- and S-peak deviations <±3.5% (within the ±5% limit). The ILPF (10–150 Hz) preserves R- and S-peak amplitudes with deviations less than −1%. Diagnostic-level recovery of ECG waveforms distorted by first- and second-order analog RC filters in ECG devices is possible with the innovative and comprehensive inverse filter design presented in this study. This approach offers a significant advancement in ECG signal processing, effectively restoring essential waveform components even after aggressive, noise-robust analog filtering in ECG acquisition circuits. Although validated for ECG signals, the proposed inverse filters are also applicable to other biosignal front-end circuits employing RC coupling.
- 15 April 2025
- Published by MDPI AG in Technologies
- Vol. 13 (4) , 159
Open AccessDesign of High-Pass and Low-Pass Active Inverse Filters to Compensate for Distortions in RC-Filtered Electrocardiograms
Distortions of electrocardiograms (ECGs) caused by mandatory high-pass and low-pass analog RC filters in ECG devices are always present. The fidelity of the ECG waveform requires limiting the RC cutoff frequencies of the diagnostic (0.05–150 Hz) and monitoring systems (0.5–40 Hz). However, the use of fixed frequency bands is a compromise between enhanced noise immunity and ECG distortions. This study aims to propose active inverse high-pass and low-pass filters which are able to compensate for distortions in digital recordings of RC-filtered ECGs, thereby overcoming the limitations imposed by analog filtering. A new straightforward design of an inverse high-pass filter (IHPF) uses an integrator as the forward-path gain block, with a feedback loop containing an active digital filter equivalent to the analog RC high-pass filter. In contrast, the inverse low-pass filter (ILPF) employs a constant-gain block in the forward path to ensure stability and prevent phase delay, while its feedback path features an active digital counterpart of the RC low-pass filter. Second-order inverse filters are created by cascading two first-order stages. The proposed filters were validated according to essential performance requirements for electrocardiographs. The low-frequency (impulse) responses of IHPFs with cutoff frequencies of 0.05–5 Hz exhibit no overshoot and undershoot by magnitudes of 0.1–25 µV, well within the ±100 µV compliance limit defined for a test rectangular pulse (3 mV, 100 ms). The high-frequency responses of ILPFs with cutoff frequencies of 10–150 Hz present a relative amplitude drop of only 0.2–2.5%, far below the 10% limit for peak amplitude reduction of a triangular pulse (1.5 mV) with 20 ms vs. 200 ms widths. For any of the eight ECG leads (I, II, and V1–V6) available in the standard signal (ANE20000), the IHPF (0.05–5 Hz) presents ST-segment deviations <5 μV (within the ±25 μV limit) and R- and S-peak deviations <±3.5% (within the ±5% limit). The ILPF (10–150 Hz) preserves R- and S-peak amplitudes with deviations less than −1%. Diagnostic-level recovery of ECG waveforms distorted by first- and second-order analog RC filters in ECG devices is possible with the innovative and comprehensive inverse filter design presented in this study. This approach offers a significant advancement in ECG signal processing, effectively restoring essential waveform components even after aggressive, noise-robust analog filtering in ECG acquisition circuits. Although validated for ECG signals, the proposed inverse filters are also applicable to other biosignal front-end circuits employing RC coupling.
- Open Access
- 8 November 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (22) , 11328
Common-Mode Driven Synchronous Filtering of the Powerline Interference in ECG
Powerline interference (PLI) is a major disturbing factor in ground-free biopotential acquisition systems. PLI produces both common-mode and differential input voltages. The first is suppressed by a high common-mode rejection ratio of bioamplifiers. However, the differential PLI component evoked by the imbalance of electrode impedances is amplified together with the diagnostic differential biosignal. Therefore, PLI filtering is always demanded and commonly managed by analog or digital band-rejection filters. In electrocardiography (ECG), PLI filters are not ideal, inducing QRS and ST distortions as a transient reaction to steep slopes, or PLI remains when its amplitude varies and PLI frequency deviates from the notch. This study aims to minimize the filter errors in wide deviation ranges of PLI amplitudes and frequencies, introducing a novel biopotential readout circuit with a software PLI demodulator–remodulator concept for synchronous processing of both differential-mode and common-mode signals. A closed-loop digital synchronous filtering (SF) algorithm is designed to subtract a PLI estimation from the differential-mode input in real time. The PLI estimation branch connected to the SF output includes four stages: (i) prefilter and QRS limiter; (ii) quadrature demodulator of the output PLI using a common-mode driven reference; (iii) two servo loops for low-pass filtering and the integration of in-phase and quadrature errors; (iv) quadrature remodulator for synthesis of the estimated PLI using the common-mode signal as a carrier frequency. A simulation study of artificially generated PLI sinusoids with frequency deviations (48–52 Hz, slew rate 0.01–0.1 Hz/s) and amplitude deviations (root mean square (r.m.s.) 50–1000 μV, slew rate 10–200 μV/s) is conducted for the optimization of SF servo loop settings with artificial signals from the CTS-ECG calibration database (10 s, 1 lead) as well as for the SF algorithm test with 40 low-noise recordings from the Physionet PTB Diagnostic ECG database (10 s, 12 leads) and CTS-ECG analytical database (10 s, 8 leads). The statistical study for the PLI frequencies (48–52 Hz, slew rate ≤ 0.1 Hz/s) and amplitudes (≤1000 μV r.m.s., slew rate ≤ 40 μV/s) show that maximal SF errors do not exceed 15 μV for any record and any lead, which satisfies the standard requirements for a peak ringing noise of < 25 μV. The signal-to-noise ratio improvement reaches 57–60 dB. SF is shown to be robust against phase shifts between differential- and common-mode PLI. Although validated for ECG signals, the presented SF algorithm is generalizable to different biopotential acquisition settings via surface electrodes (electroencephalogram, electromyogram, electrooculogram, etc.) and can benefit many diagnostic and therapeutic medical devices.
- 8 November 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (22) , 11328
Open AccessCommon-Mode Driven Synchronous Filtering of the Powerline Interference in ECG
Powerline interference (PLI) is a major disturbing factor in ground-free biopotential acquisition systems. PLI produces both common-mode and differential input voltages. The first is suppressed by a high common-mode rejection ratio of bioamplifiers. However, the differential PLI component evoked by the imbalance of electrode impedances is amplified together with the diagnostic differential biosignal. Therefore, PLI filtering is always demanded and commonly managed by analog or digital band-rejection filters. In electrocardiography (ECG), PLI filters are not ideal, inducing QRS and ST distortions as a transient reaction to steep slopes, or PLI remains when its amplitude varies and PLI frequency deviates from the notch. This study aims to minimize the filter errors in wide deviation ranges of PLI amplitudes and frequencies, introducing a novel biopotential readout circuit with a software PLI demodulator–remodulator concept for synchronous processing of both differential-mode and common-mode signals. A closed-loop digital synchronous filtering (SF) algorithm is designed to subtract a PLI estimation from the differential-mode input in real time. The PLI estimation branch connected to the SF output includes four stages: (i) prefilter and QRS limiter; (ii) quadrature demodulator of the output PLI using a common-mode driven reference; (iii) two servo loops for low-pass filtering and the integration of in-phase and quadrature errors; (iv) quadrature remodulator for synthesis of the estimated PLI using the common-mode signal as a carrier frequency. A simulation study of artificially generated PLI sinusoids with frequency deviations (48–52 Hz, slew rate 0.01–0.1 Hz/s) and amplitude deviations (root mean square (r.m.s.) 50–1000 μV, slew rate 10–200 μV/s) is conducted for the optimization of SF servo loop settings with artificial signals from the CTS-ECG calibration database (10 s, 1 lead) as well as for the SF algorithm test with 40 low-noise recordings from the Physionet PTB Diagnostic ECG database (10 s, 12 leads) and CTS-ECG analytical database (10 s, 8 leads). The statistical study for the PLI frequencies (48–52 Hz, slew rate ≤ 0.1 Hz/s) and amplitudes (≤1000 μV r.m.s., slew rate ≤ 40 μV/s) show that maximal SF errors do not exceed 15 μV for any record and any lead, which satisfies the standard requirements for a peak ringing noise of < 25 μV. The signal-to-noise ratio improvement reaches 57–60 dB. SF is shown to be robust against phase shifts between differential- and common-mode PLI. Although validated for ECG signals, the presented SF algorithm is generalizable to different biopotential acquisition settings via surface electrodes (electroencephalogram, electromyogram, electrooculogram, etc.) and can benefit many diagnostic and therapeutic medical devices.
- 4 May 2022
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 60 (6) , 1801-1814
High-quality biopotential acquisition without a reference electrode: power-line interference reduction by adaptive impedance balancing in a mixed analog–digital design
Power-line-interference (PLI) is one of the major disturbing factors in almost all ground-free biopotential acquisition applications. The body is a volume conductor and collects PLI currents. Some of these currents pass through the sensing electrodes, then the electrode cables, and finally via the amplifier input impedances they reach the signal ground. The electrode impedances and the amplifier input impedances form an impedance bridge. Due to electrode impedance instability over time, the bridge tends to be imbalanced and produces differential PLI which is amplified together with the useful signal. This paper describes a powerful mixed analog–digital solution for automatic impedance bridge balance using software PLL for line synchronization. The approach is implemented and validated through recorded real ECG signals. The PLI is canceled by adding part of the common-mode voltage, with automatically adjusted amplitude and phase, to the useful differential biosignal. The described approach produces high-quality biosignals without the need for a common-mode reference electrode. It is applicable to all biosignals taken with surface electrodes like ECG, EEG, EMG, EOG, etc., and can benefit all diagnostic and therapeutic medical devices where these signals are in use. Graphical abstract
- 4 May 2022
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 60 (6) , 1801-1814
High-quality biopotential acquisition without a reference electrode: power-line interference reduction by adaptive impedance balancing in a mixed analog–digital design
Power-line-interference (PLI) is one of the major disturbing factors in almost all ground-free biopotential acquisition applications. The body is a volume conductor and collects PLI currents. Some of these currents pass through the sensing electrodes, then the electrode cables, and finally via the amplifier input impedances they reach the signal ground. The electrode impedances and the amplifier input impedances form an impedance bridge. Due to electrode impedance instability over time, the bridge tends to be imbalanced and produces differential PLI which is amplified together with the useful signal. This paper describes a powerful mixed analog–digital solution for automatic impedance bridge balance using software PLL for line synchronization. The approach is implemented and validated through recorded real ECG signals. The PLI is canceled by adding part of the common-mode voltage, with automatically adjusted amplitude and phase, to the useful differential biosignal. The described approach produces high-quality biosignals without the need for a common-mode reference electrode. It is applicable to all biosignals taken with surface electrodes like ECG, EEG, EMG, EOG, etc., and can benefit all diagnostic and therapeutic medical devices where these signals are in use. Graphical abstract
- 5 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (22) , 25808-25817
Lossy Integrator Readout Circuit With Active Bias Point
The charge-generating sensors are widely used in many applications in consumer, automotive and medical electronics. They generate a charge proportional to the applied input quantity: pressure, temperature, acceleration, strain, light, etc. Usually, charge amplifiers are used to register such signals. The charge amplifier is an integrator that integrates the input current over time. In continuous-time signal processing, a parallel resistor is used to dissipate the energy stored on the integration capacitor, and such self-zeroed integrator circuits are known as lossy integrators. To achieve low-frequency operation, when a capacitor is in the picofarad range, a very high-ohmic resistor, in the range of gigaohms, must be used. Such a high-ohmic resistor increases the output offset voltage to an unacceptable level. To overcome the output offset problems, a composite charge amplifier has been recently introduced. This paper presents an innovative lossy integrator readout circuit which contains only one opamp in the feedback. The circuit can be easily adapted to the needed gain and cut-off frequency. Its operation is validated by experimental results. The sufficiently low high-pass cut-off frequency allows the circuit to be used for biosignal amplification. Heart and respiration rates can be easily recorded with piezoelectric sensors attached to the wrist or lung wall. The presented circuit can benefit many applications where charge-to-voltage conversion is needed.
- 5 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (22) , 25808-25817
Lossy Integrator Readout Circuit With Active Bias Point
The charge-generating sensors are widely used in many applications in consumer, automotive and medical electronics. They generate a charge proportional to the applied input quantity: pressure, temperature, acceleration, strain, light, etc. Usually, charge amplifiers are used to register such signals. The charge amplifier is an integrator that integrates the input current over time. In continuous-time signal processing, a parallel resistor is used to dissipate the energy stored on the integration capacitor, and such self-zeroed integrator circuits are known as lossy integrators. To achieve low-frequency operation, when a capacitor is in the picofarad range, a very high-ohmic resistor, in the range of gigaohms, must be used. Such a high-ohmic resistor increases the output offset voltage to an unacceptable level. To overcome the output offset problems, a composite charge amplifier has been recently introduced. This paper presents an innovative lossy integrator readout circuit which contains only one opamp in the feedback. The circuit can be easily adapted to the needed gain and cut-off frequency. Its operation is validated by experimental results. The sufficiently low high-pass cut-off frequency allows the circuit to be used for biosignal amplification. Heart and respiration rates can be easily recorded with piezoelectric sensors attached to the wrist or lung wall. The presented circuit can benefit many applications where charge-to-voltage conversion is needed.
- 15 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Application of Active Biased Integrators for Biosignal Processing
Active biased integrators (ABI) have recently been reported. The ABI is an innovative continuous-time lossy integrator characterized by a very low high-pass cutoff frequency in the millihertz range. ABI is used to amplify signals generated by sources with capacitive output impedance. This paper presents some novel ABI applications for biosignal amplification. It is shown that the heart rate and respiration activity can be easily monitored with piezoelectric sensors directly connected to ABI. The achieved very low high-pass cutoff frequency of 0.05 Hz allows ABI to be successfully used for processing ECG signals acquired with capacitive electrodes.
- 15 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Application of Active Biased Integrators for Biosignal Processing
Active biased integrators (ABI) have recently been reported. The ABI is an innovative continuous-time lossy integrator characterized by a very low high-pass cutoff frequency in the millihertz range. ABI is used to amplify signals generated by sources with capacitive output impedance. This paper presents some novel ABI applications for biosignal amplification. It is shown that the heart rate and respiration activity can be easily monitored with piezoelectric sensors directly connected to ABI. The achieved very low high-pass cutoff frequency of 0.05 Hz allows ABI to be successfully used for processing ECG signals acquired with capacitive electrodes.
- 15 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Analysis of AC Amplifiers with Ultra-low Corner Frequency by Using Bootstrapping
This paper makes analysis and evaluates the performance of a recently published circuit by Martincorena-Arraiza et al. The published schematic reveals that an opamp buffer is used to emulate a low-ohmic resistor. It also shows that an opamp output is used as a feedback input. The negative feedback must overdrive this output. Thus, the negative feedback cannot be closed normally, and the circuit can operate with an undefined bias point. The undefined bias point can lead to increased current consumption, the opamps can be saturated to the supply rails, or be in a short-circuit current limitation. The published circuit cannot work reliably. This paper shows why.
- 15 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Analysis of AC Amplifiers with Ultra-low Corner Frequency by Using Bootstrapping
This paper makes analysis and evaluates the performance of a recently published circuit by Martincorena-Arraiza et al. The published schematic reveals that an opamp buffer is used to emulate a low-ohmic resistor. It also shows that an opamp output is used as a feedback input. The negative feedback must overdrive this output. Thus, the negative feedback cannot be closed normally, and the circuit can operate with an undefined bias point. The undefined bias point can lead to increased current consumption, the opamps can be saturated to the supply rails, or be in a short-circuit current limitation. The published circuit cannot work reliably. This paper shows why.
- 14 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (14) , 16395
Comments on “An Analog Bootstrapped Biosignal Read-Out Circuit With Common-Mode Impedance Two-Electrode Compensation”
This paper comments on a recently published article by Parente et al. in [1].
- 14 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (14) , 16395
Comments on “An Analog Bootstrapped Biosignal Read-Out Circuit With Common-Mode Impedance Two-Electrode Compensation”
This paper comments on a recently published article by Parente et al. in [1].
- 16 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Correlated Multiple Sampling Techniques for Sensor Signal Conditioning
Correlated Double Sampling (CDS) is a widely used technique in sensor signal conditioning. It effectively cancels offset and low-frequency (flicker) noise. CDS is a discrete time signal processing technique, implemented with Switched Capacitor (SC) circuits or after ADC with a Digital Signal Processing (DSP) algorithm. This paper describes a simple approach wherein the CDS technique is extended to Correlated Multiple Sampling (CMS) techniques, and with the price of processing of more samples, the new CMS techniques greatly improves the amplifier offset and flicker noise suppression.
- 16 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Correlated Multiple Sampling Techniques for Sensor Signal Conditioning
Correlated Double Sampling (CDS) is a widely used technique in sensor signal conditioning. It effectively cancels offset and low-frequency (flicker) noise. CDS is a discrete time signal processing technique, implemented with Switched Capacitor (SC) circuits or after ADC with a Digital Signal Processing (DSP) algorithm. This paper describes a simple approach wherein the CDS technique is extended to Correlated Multiple Sampling (CMS) techniques, and with the price of processing of more samples, the new CMS techniques greatly improves the amplifier offset and flicker noise suppression.
- 16 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Software Automatic Gain Control for Common Mode Interference Stabilization
Automatic gain control (AGC) circuits are used in many systems where the amplitude of the input signal can vary over a wide dynamic range. The role of the AGC is to provide relatively constant amplitude of the output signal, regardless of changes in the input signal. This paper presents software automatic gain control (SAGC) designed to stabilize the amplitude of the common mode interference. The described SAGC provides a constant amplitude output signal for software PLL synchronization to the power-line frequency. The presented SAGC has simple structure and can be easily adapted to other signal processing applications where automatic gain control is required.
- 16 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Software Automatic Gain Control for Common Mode Interference Stabilization
Automatic gain control (AGC) circuits are used in many systems where the amplitude of the input signal can vary over a wide dynamic range. The role of the AGC is to provide relatively constant amplitude of the output signal, regardless of changes in the input signal. This paper presents software automatic gain control (SAGC) designed to stabilize the amplitude of the common mode interference. The described SAGC provides a constant amplitude output signal for software PLL synchronization to the power-line frequency. The presented SAGC has simple structure and can be easily adapted to other signal processing applications where automatic gain control is required.
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Automatic Common Mode Electrode-Amplifier Impedance Balance: Implementation and Results
Power-line interference (PLI) is the major disturbing factor in all ground-free biosignal acquisition applications. The PLI currents picked up by the body must flow through the sensing electrodes, then the electrode cables and finally via the amplifier input impedances they reach the amplifier ground. The electrode impedances and the amplifier input impedances form Wheatstone bridge. Because the electrode impedances vary with time, the bridge tends to be imbalanced and produces differential PLI which is amplified together with the useful signal. An automatic impedance balancing approach, using software PLL for line synchronization, was published. This paper validates the approach through practical results from its implementation.
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Automatic Common Mode Electrode-Amplifier Impedance Balance: Implementation and Results
Power-line interference (PLI) is the major disturbing factor in all ground-free biosignal acquisition applications. The PLI currents picked up by the body must flow through the sensing electrodes, then the electrode cables and finally via the amplifier input impedances they reach the amplifier ground. The electrode impedances and the amplifier input impedances form Wheatstone bridge. Because the electrode impedances vary with time, the bridge tends to be imbalanced and produces differential PLI which is amplified together with the useful signal. An automatic impedance balancing approach, using software PLL for line synchronization, was published. This paper validates the approach through practical results from its implementation.