Ibtisam Aslam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ibtisam Aslam has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Jean-Paul Vallée
Department of Radiology, University Hospitals of Geneva (HUG), Geneva, Switzerland
3 shared publications Fariha Aamir
Medical Image Processing Research Group (MIPRG), Department of Electrical & Computer Engineering, COMSATS University Islamabad, Islamabad, Pakistan
2 shared publicationsHammad Omer
Medical Image Processing Research Group (MIPRG), Electrical & Computer Engineering Department, COMSATS University Islamabad, Islamabad, Pakistan
2 shared publications- Hammad Omer
Medical Image Processing Research Group (MIPRG), Department of Electrical & Computer Engineering, COMSATS University Islamabad, Pakistan
2 shared publications - Bastien Milani
Institute of Systems Engineering, School of Engineering, HES-SO Valais-Wallis University of Applied Sciences and Arts Western Switzerland, Rue de l’industrie 23, Sion, Switzerland
1 shared publication Faisal Najeeb
Department of Electrical Engineering, COMSATS Institute of Information Technology, Islamabad, Pakistan
1 shared publication
Latest Publications
- Open Access
- 15 February 2023
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 18 (2) , e0277277
Validation of automatically measured T1 map cortico-medullary difference (ΔT1) for eGFR and fibrosis assessment in allograft kidneys
MRI T1-mapping is an important non-invasive tool for renal diagnosis. Previous work shows that ΔT1 (cortex-medullary difference in T1) has significant correlation with interstitial fibrosis in chronic kidney disease (CKD) allograft patients. However, measuring cortico-medullary values by manually drawing ROIs over cortex and medulla (a gold standard method) is challenging, time-consuming, subjective and requires human training. Moreover, such subjective ROI placement may also affect the work reproducibility. This work proposes a deep learning-based 2D U-Net (RCM U-Net) to auto-segment the renal cortex and medulla of CKD allograft kidney T1 maps. Furthermore, this study presents a correlation of automatically measured ΔT1 values with eGFR and percentage fibrosis in allograft kidneys. Also, the RCM U-Net correlation results are compared with the manual ROI correlation analysis. The RCM U-Net has been trained and validated on T1 maps from 40 patients (n = 2400 augmented images) and tested on 10 patients (n = 600 augmented images). The RCM U-Net segmentation results are compared with the standard VGG16, VGG19, ResNet34 and ResNet50 networks with U-Net as backbone. For clinical validation of the RCM U-Net segmentation, another set of 114 allograft kidneys patient’s cortex and medulla were automatically segmented to measure the ΔT1 values and correlated with eGFR and fibrosis. Overall, the RCM U-Net showed 50% less Mean Absolute Error (MAE), 16% better Dice Coefficient (DC) score and 12% improved results in terms of Sensitivity (SE) over conventional CNNs (i.e. VGG16, VGG19, ResNet34 and ResNet50) while the Specificity (SP) and Accuracy (ACC) did not show significant improvement (i.e. 0.5% improvement) for both cortex and medulla segmentation. For eGFR and fibrosis assessment, the proposed RCM U-Net correlation coefficient (r) and R-square (R2) was better correlated (r= -0.2, R2= 0.041 withp= 0.039) to eGFR than manual ROI values (r= -0.19, R2= 0.037 withp= 0.051). Similarly, the proposed RCM U-Net had noticeably betterrand R2values (r= 0.25, R2= 0.065 withp= 0.007) for the correlation with the renal percentage fibrosis than the Manual ROI results (r= 0.3, R2= 0.091 andp= 0.0013). Using a linear mixed model, T1 was significantly higher in the medulla than in the cortex (ppp= 0.43), nor between the types of T1 measurements (Gold standard manual versus automated RCM U-Net) (p= 0.7). The cortico-medullary area ratio measured by the RCM U-Net was significantly increased in case of cellular rejection by comparison to humoral rejection (1.6 +/- 0.39 versus 0.99 +/- 0.32,p= 0.019). In conclusion, the proposed RCM U-Net provides more robust auto-segmented cortex and medulla than the other standard CNNs allowing a good correlation of ΔT1 with eGFR and fibrosis as reported in literature as well as the differentiation of cellular and humoral transplant rejection. Therefore, the proposed approach is a promising alternative to the gold standard manual ROI method to measure T1 values without user interaction, which helps to reduce analysis time and improves reproducibility.
- 15 February 2023
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 18 (2) , e0277277
Open AccessValidation of automatically measured T1 map cortico-medullary difference (ΔT1) for eGFR and fibrosis assessment in allograft kidneys
MRI T1-mapping is an important non-invasive tool for renal diagnosis. Previous work shows that ΔT1 (cortex-medullary difference in T1) has significant correlation with interstitial fibrosis in chronic kidney disease (CKD) allograft patients. However, measuring cortico-medullary values by manually drawing ROIs over cortex and medulla (a gold standard method) is challenging, time-consuming, subjective and requires human training. Moreover, such subjective ROI placement may also affect the work reproducibility. This work proposes a deep learning-based 2D U-Net (RCM U-Net) to auto-segment the renal cortex and medulla of CKD allograft kidney T1 maps. Furthermore, this study presents a correlation of automatically measured ΔT1 values with eGFR and percentage fibrosis in allograft kidneys. Also, the RCM U-Net correlation results are compared with the manual ROI correlation analysis. The RCM U-Net has been trained and validated on T1 maps from 40 patients (n = 2400 augmented images) and tested on 10 patients (n = 600 augmented images). The RCM U-Net segmentation results are compared with the standard VGG16, VGG19, ResNet34 and ResNet50 networks with U-Net as backbone. For clinical validation of the RCM U-Net segmentation, another set of 114 allograft kidneys patient’s cortex and medulla were automatically segmented to measure the ΔT1 values and correlated with eGFR and fibrosis. Overall, the RCM U-Net showed 50% less Mean Absolute Error (MAE), 16% better Dice Coefficient (DC) score and 12% improved results in terms of Sensitivity (SE) over conventional CNNs (i.e. VGG16, VGG19, ResNet34 and ResNet50) while the Specificity (SP) and Accuracy (ACC) did not show significant improvement (i.e. 0.5% improvement) for both cortex and medulla segmentation. For eGFR and fibrosis assessment, the proposed RCM U-Net correlation coefficient (r) and R-square (R2) was better correlated (r= -0.2, R2= 0.041 withp= 0.039) to eGFR than manual ROI values (r= -0.19, R2= 0.037 withp= 0.051). Similarly, the proposed RCM U-Net had noticeably betterrand R2values (r= 0.25, R2= 0.065 withp= 0.007) for the correlation with the renal percentage fibrosis than the Manual ROI results (r= 0.3, R2= 0.091 andp= 0.0013). Using a linear mixed model, T1 was significantly higher in the medulla than in the cortex (ppp= 0.43), nor between the types of T1 measurements (Gold standard manual versus automated RCM U-Net) (p= 0.7). The cortico-medullary area ratio measured by the RCM U-Net was significantly increased in case of cellular rejection by comparison to humoral rejection (1.6 +/- 0.39 versus 0.99 +/- 0.32,p= 0.019). In conclusion, the proposed RCM U-Net provides more robust auto-segmented cortex and medulla than the other standard CNNs allowing a good correlation of ΔT1 with eGFR and fibrosis as reported in literature as well as the differentiation of cellular and humoral transplant rejection. Therefore, the proposed approach is a promising alternative to the gold standard manual ROI method to measure T1 values without user interaction, which helps to reduce analysis time and improves reproducibility.
- Open Access
- 4 November 2022
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 36 (1) , 276-288
Accelerated Diffusion-Weighted MR Image Reconstruction Using Deep Neural Networks
Under-sampling in diffusion-weighted imaging (DWI) decreases the scan time that helps to reduce off-resonance effects, geometric distortions, and susceptibility artifacts; however, it leads to under-sampling artifacts. In this paper, diffusion-weighted MR image (DWI-MR) reconstruction using deep learning (DWI U-Net) is proposed to recover artifact-free DW images from variable density highly under-sampled k-space data. Additionally, different optimizers, i.e., RMSProp, Adam, Adagrad, and Adadelta, have been investigated to choose the best optimizers for DWI U-Net. The reconstruction results are compared with the conventional Compressed Sensing (CS) reconstruction. The quality of the recovered images is assessed using mean artifact power (AP), mean root mean square error (RMSE), mean structural similarity index measure (SSIM), and mean apparent diffusion coefficient (ADC). The proposed method provides up to 61.1%, 60.0%, 30.4%, and 28.7% improvements in the mean AP value of the reconstructed images in our experiments with different optimizers, i.e., RMSProp, Adam, Adagrad, and Adadelta, respectively, as compared to the conventional CS at an acceleration factor of 6 (i.e., AF = 6). The results of DWI U-Net with the RMSProp, Adam, Adagrad, and Adadelta optimizers show 13.6%, 10.0%, 8.7%, and 8.74% improvements, respectively, in terms of mean SSIM with respect to the conventional CS at AF = 6. Also, the proposed technique shows 51.4%, 29.5%, 24.04%, and 18.0% improvements in terms of mean RMSE using the RMSProp, Adam, Adagrad, and Adadelta optimizers, respectively, with reference to the conventional CS at AF = 6. The results confirm that DWI U-Net performs better than the conventional CS reconstruction. Also, when comparing the different optimizers in DWI U-Net, RMSProp provides better results than the other optimizers.
- 4 November 2022
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 36 (1) , 276-288
Open AccessAccelerated Diffusion-Weighted MR Image Reconstruction Using Deep Neural Networks
Under-sampling in diffusion-weighted imaging (DWI) decreases the scan time that helps to reduce off-resonance effects, geometric distortions, and susceptibility artifacts; however, it leads to under-sampling artifacts. In this paper, diffusion-weighted MR image (DWI-MR) reconstruction using deep learning (DWI U-Net) is proposed to recover artifact-free DW images from variable density highly under-sampled k-space data. Additionally, different optimizers, i.e., RMSProp, Adam, Adagrad, and Adadelta, have been investigated to choose the best optimizers for DWI U-Net. The reconstruction results are compared with the conventional Compressed Sensing (CS) reconstruction. The quality of the recovered images is assessed using mean artifact power (AP), mean root mean square error (RMSE), mean structural similarity index measure (SSIM), and mean apparent diffusion coefficient (ADC). The proposed method provides up to 61.1%, 60.0%, 30.4%, and 28.7% improvements in the mean AP value of the reconstructed images in our experiments with different optimizers, i.e., RMSProp, Adam, Adagrad, and Adadelta, respectively, as compared to the conventional CS at an acceleration factor of 6 (i.e., AF = 6). The results of DWI U-Net with the RMSProp, Adam, Adagrad, and Adadelta optimizers show 13.6%, 10.0%, 8.7%, and 8.74% improvements, respectively, in terms of mean SSIM with respect to the conventional CS at AF = 6. Also, the proposed technique shows 51.4%, 29.5%, 24.04%, and 18.0% improvements in terms of mean RMSE using the RMSProp, Adam, Adagrad, and Adadelta optimizers, respectively, with reference to the conventional CS at AF = 6. The results confirm that DWI U-Net performs better than the conventional CS reconstruction. Also, when comparing the different optimizers in DWI U-Net, RMSProp provides better results than the other optimizers.
- Open Access
- 1 November 2022
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 8 (6) , 065037
Real-time, single breath-hold, multi-slice, 2D cine radial MR image reconstruction using sc-GROG k-t ESPIRiT
Background: Multi-slice, multiple breath-hold ECG-gated 2D cine MRI is a standard technique for evaluating heart function and restricted to one or two images per breath-hold. Therefore, the standard cine MRI requires long scan time and can result in slice-misalignments because of various breath-hold locations in the multiple acquisitions. Methods: This work proposes the sc-GROG based k-t ESPIRiT with Total Variation (TV) constraint (sc-GROG k-t ESPIRiT) to reconstruct unaliased cardiac real-time cine MR images from highly accelerated whole heart multi-slice, single breath-hold, real-time 2D cine radial data acquired using the balanced steady-state free precession (trueFISP) sequence in 8 patients. The proposed method quality is assessed via Artifact Power (AP), Root-Mean Square Error (RMSE), Structure Similarity Index (SSIM), Peak Signal-to-Noise Ratio (PSNR), blood-pool to myocardial Contrast-to-Noise-Ratio (CNR), Signal-to-Noise-Ratio (SNR) and spatial-temporal intensity plots through the blood-myocardium boundary. The proposed method quantitative results are compared with the NUFFT based k-t ESPIRiT with Total Variation (TV) constraint (NUFFT k-t ESPIRiT) approach. Furthermore, clinical analysis and function quantification are assessed by Bland–Altman (BA) analyses. Results: As supported by the visual assessment and evaluation parameters, the reconstruction results of the sc-GROG k-t ESPIRiT approach provide an average 21%, 12%, 1% and 47% improvement in AP, RMSE, SSIM and PSNR, respectively in comparison to the NUFFT k-t ESPIRiT approach. Furthermore, the proposed method gives on average 45% and 58% improved blood-pool to myocardial CNR and SNR than the NUFFT k-t ESPIRiT approach. Also, from the BA plot, the proposed method gives better left ventricular and right ventricular function measurements as compared to the NUFFT k-t ESPIRiT scheme. Conclusions: The sc-GROG k-t ESPIRiT (Proposed Method) improves the spatio-temporal quality of the whole heart multi-slice, single breath-hold, real-time 2D cine radial MR and semi-automated analysis using standard clinical software, as compared to the NUFFT k-t ESPIRiT approach.
- 1 November 2022
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 8 (6) , 065037
Open AccessReal-time, single breath-hold, multi-slice, 2D cine radial MR image reconstruction using sc-GROG k-t ESPIRiT
Background: Multi-slice, multiple breath-hold ECG-gated 2D cine MRI is a standard technique for evaluating heart function and restricted to one or two images per breath-hold. Therefore, the standard cine MRI requires long scan time and can result in slice-misalignments because of various breath-hold locations in the multiple acquisitions. Methods: This work proposes the sc-GROG based k-t ESPIRiT with Total Variation (TV) constraint (sc-GROG k-t ESPIRiT) to reconstruct unaliased cardiac real-time cine MR images from highly accelerated whole heart multi-slice, single breath-hold, real-time 2D cine radial data acquired using the balanced steady-state free precession (trueFISP) sequence in 8 patients. The proposed method quality is assessed via Artifact Power (AP), Root-Mean Square Error (RMSE), Structure Similarity Index (SSIM), Peak Signal-to-Noise Ratio (PSNR), blood-pool to myocardial Contrast-to-Noise-Ratio (CNR), Signal-to-Noise-Ratio (SNR) and spatial-temporal intensity plots through the blood-myocardium boundary. The proposed method quantitative results are compared with the NUFFT based k-t ESPIRiT with Total Variation (TV) constraint (NUFFT k-t ESPIRiT) approach. Furthermore, clinical analysis and function quantification are assessed by Bland–Altman (BA) analyses. Results: As supported by the visual assessment and evaluation parameters, the reconstruction results of the sc-GROG k-t ESPIRiT approach provide an average 21%, 12%, 1% and 47% improvement in AP, RMSE, SSIM and PSNR, respectively in comparison to the NUFFT k-t ESPIRiT approach. Furthermore, the proposed method gives on average 45% and 58% improved blood-pool to myocardial CNR and SNR than the NUFFT k-t ESPIRiT approach. Also, from the BA plot, the proposed method gives better left ventricular and right ventricular function measurements as compared to the NUFFT k-t ESPIRiT scheme. Conclusions: The sc-GROG k-t ESPIRiT (Proposed Method) improves the spatio-temporal quality of the whole heart multi-slice, single breath-hold, real-time 2D cine radial MR and semi-automated analysis using standard clinical software, as compared to the NUFFT k-t ESPIRiT approach.
- Open Access
- 11 July 2022
- Published by MDPI AG in Kidney and Dialysis
- Vol. 2 (3) , 407-418
Magnetic Resonance Imaging to Diagnose and Predict the Outcome of Diabetic Kidney Disease—Where Do We Stand?
Diabetic kidney disease (DKD) is a major public health problem and its incidence is rising. The disease course is unpredictable with classic biomarkers, and the search for new tools to predict adverse renal outcomes is ongoing. Renal magnetic resonance imaging (MRI) now enables the quantification of metabolic and microscopic properties of the kidneys such as single-kidney, cortical and medullary blood flow, and renal tissue oxygenation and fibrosis, without the use of contrast media. A rapidly increasing number of studies show that these techniques can identify early kidney damage in patients with DKD, and possibly predict renal outcome. This review provides an overview of the currently most frequently used techniques, a summary of the results of some recent studies, and our view on their potential applications, as well as the hurdles to be overcome for the integration of these techniques into the clinical care of patients with DKD.
- 11 July 2022
- Published by MDPI AG in Kidney and Dialysis
- Vol. 2 (3) , 407-418
Open AccessMagnetic Resonance Imaging to Diagnose and Predict the Outcome of Diabetic Kidney Disease—Where Do We Stand?
Diabetic kidney disease (DKD) is a major public health problem and its incidence is rising. The disease course is unpredictable with classic biomarkers, and the search for new tools to predict adverse renal outcomes is ongoing. Renal magnetic resonance imaging (MRI) now enables the quantification of metabolic and microscopic properties of the kidneys such as single-kidney, cortical and medullary blood flow, and renal tissue oxygenation and fibrosis, without the use of contrast media. A rapidly increasing number of studies show that these techniques can identify early kidney damage in patients with DKD, and possibly predict renal outcome. This review provides an overview of the currently most frequently used techniques, a summary of the results of some recent studies, and our view on their potential applications, as well as the hurdles to be overcome for the integration of these techniques into the clinical care of patients with DKD.
- 1 December 2021
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 333, 107080
Tangent vector-based gradient method with -regularization: Iterative half thresholding algorithm for CS-MRI- 1 December 2021
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 333, 107080
Tangent vector-based gradient method with -regularization: Iterative half thresholding algorithm for CS-MRI- 14 September 2017
- Published by Springer Nature in Applied Magnetic Resonance
- Vol. 49 (1) , 107-124
Accelerating MRI Using GROG Gridding Followed by ESPIRiT for Non-Cartesian Trajectories
- 14 September 2017
- Published by Springer Nature in Applied Magnetic Resonance
- Vol. 49 (1) , 107-124
Accelerating MRI Using GROG Gridding Followed by ESPIRiT for Non-Cartesian Trajectories