CCCrystal Compton

Crystal Compton

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Crystal Compton has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Systematic Review of Kangaroo Care Duration's Impact in Neonatal Intensive Care Units on Infant–Maternal Health

    by Abigail R Clarke-Sather, Crystal Compton, Kari Roberts, Ann Brearley, Sonya G Wang

    Kangaroo care (KC), skin-to-skin contact between infants and caregivers, is encouraged in neonatal intensive care units (NICUs) to support health through improved weight, growth, and infant–maternal attachment while reducing the incidence of sepsis and infant pain. However, the optimal duration and frequency of KC to maximize health outcomes is unknown. Given parents' time stressors, identifying optimal KC time is critical. A literature review was undertaken on May 28, 2021 via querying the PubMed database from January 1, 1995, to May 28, 2021, regarding KC and NICUs with 442 results. Eleven studies met the eligibility criteria of (1) comparative KC between infants and adult caregivers in NICUs as a randomized controlled trial, (2) peer-reviewed articles in English, (3) study subjects ≥5, (4) health outcomes, and (5) KC sessions >1. Infant physical growth parameters, infant neurodevelopment, infant stress via salivary cortisol levels, and breastfeeding outcomes appear to increase with KC as compared with standard care (SC) without KC. Improvements were observed with longer KC duration, 2 h/d as compared with 1 h/d, for neurodevelopment and breastfeeding outcomes, but no greater improvement with longer KC duration was shown for reducing infant stress through salivary cortisol levels. Regarding maternal stress, the influence of KC duration showed mixed Parental Stressor Score: NICU scores. Further study on the impact of KC duration and frequency on health outcomes and dose–response relationship would help determine how much and how frequent KC is needed to improve specific health outcomes for infants and their mothers. Key Points


  • Open Access

    Dynamic, Tunable, and Conformal Wearable Compression Using Active Textiles

    by Rachael Granberry, Megan Clarke, Robert Pettys‐Baker, Heidi Woelfle, Crystal Compton, Amy Ross, Kirstyn Johnson, Santo Padula, Surbhi Shah, Julianna Abel, et al.

    New medical compression technologies that are simultaneously low‐profile, facile to don, and dynamic—applying medical compression only when needed—can expand the use of wearable compression, increase patient compliance, and lead to better medical outcomes. Dynamic and conformal wearable compression devices are presented that can be donned in a low‐stiffness state and transition into a high‐stiffness and, consequently, high‐compression state, on‐demand. These devices are enabled by active textiles developed from custom NiTi filaments that remain inactive at room temperature and accomplish actuation proximal to the human body surface. Further, these compression devices exploit NiTi material hysteresis to sustain a high‐compression state post‐heating and upon equilibrium with the body surface temperature for thermally‐comfortable, on‐body performance. Two case study examples—1) a consumer medical compression device and 2) a custom astronaut compression device—demonstrate the generalizability and flexibility of the engineering and design methods to develop a range of dynamic, tunable, and conformal compression devices with different goals and requirements. Further, this work demonstrates a roadmap for developing wearable systems that can accommodate a range of users without sacrificing system performance. This research opens doors for new NiTi‐based medical and consumer applications that interface with the body surface.


  • Enhancing performance and reducing wearing variability for wearable technology system–body interfaces using shape memory materials

    by Rachael Granberry, Crystal Compton, Heidi Woelfle, Justin Barry, Brad Holschuh

    Advancements in e-textiles, sensors, and actuators have propelled wearable technologies toward wide-spread market use, however the physical interface between these technologies and the human body has remained a functional challenge. Prior research has found that system–body interface challenges produce wearing variability, or variation in system placement, orientation, and tightness in relation to a body both between use trials and between users, resulting in large variation and deterioration in system performance. We break down the mechanics of common system–body interface challenges through a summary of design principles critical to any system interfacing with the human body. Additionally, we present an active interface based on shape memory materials that dimensionally adapts to its user’s dimensions. An experimental investigation of these active system interfaces considers the impact of design variables often overlooked in the design process. Recommendations are provided to optimize interfaces for the requirements for a given wearable technology. Additionally, we illuminate methods to reduce wearing variability for a range of users to produce consistent system–body interaction across a user population. Through these active interfaces, we advance a broad range of wearable technologies, including wearable sensing, motion tracking, haptics, and wearable robotic devices.


  • Open Access

    Product Development Process for E-Textile Garments: A Design Guideline for Apparel Manufacturers

    by Crystal Compton, Lucy E. Dunne, Tahmidul Islam Molla


  • Open Access

    Evaluation of Textile-Based Wearable Force Sensors for Functional Clothing Applications

    by Alireza Golgouneh, Brad Holschuh, Crystal Compton, Lucy E. Dunne


  • Open Access

    Identifying Challenges of Fabricating E-textile Garments Via a Case Study

    by Tahmidul Islam Molla, Crystal Compton, Lucy E. Dunne

    Integration of electronic components and circuits into clothing is a key requirement of garment-integrated technologies, especially when the electronics need to be distributed over the clothing surface, which allows power and networking to be localized, placement of electronics to be more broadly distributed, and reduces the necessity of using and managing many body-worn units. The disparity in material properties between electronics (primarily hard goods) and textiles (primarily soft goods), as well as differences in their manufacturing processes, exacerbate the difficulty of scalable integration of electronics into clothing. Though many researchers have developed example applications of e-textiles in fashion and other artistic applications, these garments often use hand-sewing methods that are not efficiently replicable in the industrial setting. In this paper, the scalable manufacturing technique we have developed that facilitates surface-mount soldering of discrete components and ICs directly onto fabric surfaces is translated into garment form as an intermediate step toward full-scale manufacturing. Through the fabrication process of an example garment, variables relevant to manufacturing garment-integrated electronics are discovered and discussed.