  • Ultra-pure nickel for structural components of low-radioactivity instruments

    by T.J. Roosendaal, C.T. Overman, G.S. Ortega, T.D. Schlieder, N.D. Rocco, L.K.S. Horkley, K.P. Hobbs, K. Harouaka, J.L. Orrell, P. Acharya, et al.


  • Open Access

    Ultra-pure Nickel for Structural Components of Low-Radioactivity Instruments

    by T. J. Roosendaal, C. T. Overman, G. S. Ortega, T. D. Schlieder, N. D. Rocco, L. K. S. Horkley, K. P. Hobbs, K. Harouaka, J. L. Orrell, P. Acharya, et al.

    The next generation of rare-event search experiments in nuclear and particle physics demand structural materials combining exceptional mechanical strength with ultra-low levels of radioactive contamination. This study evaluates chemical vapor deposition (CVD) nickel as a candidate structural material for such applications. Manufacturer-supplied CVD Ni grown on aluminum substrates underwent tensile testing before and after welding alongside standard Ni samples. CVD Ni exhibited a planar tensile strength of ~600 MPa, significantly surpassing standard nickel. However, welding and heat treatment were found to reduce the tensile strength to levels comparable to standard Ni, with observed porosity in the welds likely contributing to this reduction. Material assay via inductively coupled plasma mass spectrometry (ICP-MS) employing isotope-dilution produced measured bulk concentration of 232-Th, 238-U, and nat-K at the levels of ~70 ppq, <100 ppq, and ~900 ppt, respectively, which is the lowest reported in nickel. Surface-etch profiling uncovered higher concentrations of these contaminants extending ~10 micrometer beneath the surface, likely associated with the aluminum growth substrate. The results reported are compared to the one other well documented usage of CVD Ni in a low radioactive background physics research experiment and a discussion is provided on how the currently reported results may arise from changes in CVD fabrication or testing process. These results establish CVD Ni as a promising low-radioactivity structural material, while outlining the need for further development in welding and surface cleaning techniques to fully realize its potential in large-scale, low radioactive background rare-event search experiments.

  • An integrated online radioassay data storage and analytics tool for nEXO

    by R.H.M. Tsang, A. Piepke, S. Al Kharusi, E. Angelico, I.J. Arnquist, A. Atencio, I. Badhrees, J. Bane, V. Belov, E.P. Bernard, et al.


  • Open Access

    A Simple Ventilator Designed To Be Used in Shortage Crises: Construction and Verification Testing

    by Daniel S Akerib, Andrew Ames, Martin Breidenbach, Michael Bressack, Pieter A Breur, Eric Charles, David M Gaba, Ryan Herbst, Christina M Ignarra, Steffen Luitz, et al.

    Background: The COVID-19 pandemic has demonstrated the possibility of severe ventilator shortages in the near future. Objective: We aimed to develop an acute shortage ventilator. Methods: The ventilator was designed to mechanically compress a self-inflating bag resuscitator, using a modified ventilator patient circuit, which is controlled by a microcontroller and an optional laptop. It was designed to operate in both volume-controlled mode and pressure-controlled assist modes. We tested the ventilator in 4 modes using an artificial lung while measuring the volume, flow, and pressure delivered over time by the ventilator. Results: The ventilator was successful in reaching the desired tidal volume and respiratory rates specified in national emergency use resuscitator system guidelines. The ventilator responded to simulated spontaneous breathing. Conclusions: The key design goals were achieved. We developed a simple device with high performance for short-term use, made primarily from common hospital parts and generally available nonmedical components to avoid any compatibility or safety issues with the patient, and at low cost, with a unit cost per ventilator is less than $400 US excluding the patient circuit parts, that can be easily manufactured.


  • Open Access

    A Simple Ventilator Designed To Be Used in Shortage Crises: Construction and Verification Testing (Preprint)

    by Daniel S Akerib, Andrew Ames, Martin Breidenbach, Michael Bressack, Pieter A Breur, Eric Charles, David M Gaba, Ryan Herbst, Christina M Ignarra, Steffen Luitz, et al.

    BACKGROUND The COVID-19 pandemic has demonstrated the possibility of severe ventilator shortages in the near future. OBJECTIVE We aimed to develop an acute shortage ventilator. METHODS The ventilator was designed to mechanically compress a self-inflating bag resuscitator, using a modified ventilator patient circuit, which is controlled by a microcontroller and an optional laptop. It was designed to operate in both volume-controlled mode and pressure-controlled assist modes. We tested the ventilator in 4 modes using an artificial lung while measuring the volume, flow, and pressure delivered over time by the ventilator. RESULTS The ventilator was successful in reaching the desired tidal volume and respiratory rates specified in national emergency use resuscitator system guidelines. The ventilator responded to simulated spontaneous breathing. CONCLUSIONS The key design goals were achieved. We developed a simple device with high performance for short-term use, made primarily from common hospital parts and generally available nonmedical components to avoid any compatibility or safety issues with the patient, and at low cost, with a unit cost per ventilator is less than $400 US excluding the patient circuit parts, that can be easily manufactured. CLINICALTRIAL