Daniil I. Ivanchenko
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Daniil I. Ivanchenko has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Aleksey A. Belsky
Saint-Petersburg Mining University
5 shared publications - Vasiliy S. Dobush
Department of General Electrical Engineering, Saint-Petersburg Mining University, 199106 Saint-Petersburg, Russia
2 shared publications Artem I. Smirnov
Electromechanical Faculty, Saint Petersburg Mining University, Saint Petersburg, Russia
1 shared publicationArtem Smirnov
Saint-Petersburg Mining University, Department of Electrical Engineering, 199106 St Petersburg, Russian Federation
1 shared publication- Emiliia Iakovleva
General Electrical Engineering Department, Saint Petersburg Mining University, 2, 21st Line, 199106 St. Petersburg, Russia
1 shared publication Emiliya V. Yakovleva
Department of Electrical Engineering, Saint-Petersburg Mining University, St. Petersburg, Russia
1 shared publication
Latest Publications
- Open Access
- 18 December 2019
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 140, 04007
Identification of interturn faults in power transformers by means of generalized symmetrical components analysis
The paper deals with experimental identification of transformer internal faults, an important factor in reliability and sustainability of power supply systems. Task of identification of transformer internal faults requires increasing sensitivity of relay protection by calculation of components most sensitive to interwire faults from transformer current. In order to study internal faults in transformer, the model in Simulink MATLAB was developed on the basis of transformer constitutive equations. Transformer with short circuited wires was simulated as a multiwinding transformer. We provide the calculation of transformer parameters. Model was applied for analysis of transients in power transformers, such as interwire fault, transformer inrush, and fault in transformer connections. Analysis of power transformer internal faults by means of time-dependent symmetrical components of currents is provided. These symmetrical components were calculated for the first harmonic of current by means of discrimination of firs harmonic by low-pass filter and compensating elements implementing phase shift. Described method allows calculation of symmetrical components during transient and under non-sinusoidal conditions. Simulation results showed the advantage of instantaneous symmetrical components of other direct values. Those components were implemented in relay protection algorithms for identification of internal faults in transformers.
- 18 December 2019
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 140, 04007
Open AccessIdentification of interturn faults in power transformers by means of generalized symmetrical components analysis
The paper deals with experimental identification of transformer internal faults, an important factor in reliability and sustainability of power supply systems. Task of identification of transformer internal faults requires increasing sensitivity of relay protection by calculation of components most sensitive to interwire faults from transformer current. In order to study internal faults in transformer, the model in Simulink MATLAB was developed on the basis of transformer constitutive equations. Transformer with short circuited wires was simulated as a multiwinding transformer. We provide the calculation of transformer parameters. Model was applied for analysis of transients in power transformers, such as interwire fault, transformer inrush, and fault in transformer connections. Analysis of power transformer internal faults by means of time-dependent symmetrical components of currents is provided. These symmetrical components were calculated for the first harmonic of current by means of discrimination of firs harmonic by low-pass filter and compensating elements implementing phase shift. Described method allows calculation of symmetrical components during transient and under non-sinusoidal conditions. Simulation results showed the advantage of instantaneous symmetrical components of other direct values. Those components were implemented in relay protection algorithms for identification of internal faults in transformers.
- Open Access
- 1 November 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 643 (1) , 012082
Identification of transformer equivalent circuit parameters for transients simulation
The paper deals with experimental identification of transformer equivalent circuit parameters for simulation purpose. Dependences of transformer voltage and power from primary winding current in open circuit configuration were measured. Current to voltage characteristic of magnetic losses nonlinear resistor, flux to current characteristic of magnetic core, resistance and leakage inductance of primary and secondary windings of one-phase transformer were calculated from the measured parameters. Equivalent circuit of the transformer allowing calculation of transformer transients, such as inrush and overload, was obtained as a result.
- 1 November 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 643 (1) , 012082
Open AccessIdentification of transformer equivalent circuit parameters for transients simulation
The paper deals with experimental identification of transformer equivalent circuit parameters for simulation purpose. Dependences of transformer voltage and power from primary winding current in open circuit configuration were measured. Current to voltage characteristic of magnetic losses nonlinear resistor, flux to current characteristic of magnetic core, resistance and leakage inductance of primary and secondary windings of one-phase transformer were calculated from the measured parameters. Equivalent circuit of the transformer allowing calculation of transformer transients, such as inrush and overload, was obtained as a result.
- 1 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 977-980
Simulation of Interwire Short Circuits in Transformer Windings by Means of Simulink MATLAB
The paper deals with simulation of transformer interwire faults in Simulink MATLAB. Transformer with short circuited wires was simulated as multiwinding transformer. Model was applied for analysis of transients in power transformer, such as interwire fault, transformer inrush, and fault in transformer connections. Simulation results were compared to experimental data, obtained with laboratory transformer, and showed satisfactory precision. Presented model allows calculation of transformer fault currents and analysis of other transients, such as inrush and overload.
- 1 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 977-980
Simulation of Interwire Short Circuits in Transformer Windings by Means of Simulink MATLAB
The paper deals with simulation of transformer interwire faults in Simulink MATLAB. Transformer with short circuited wires was simulated as multiwinding transformer. Model was applied for analysis of transients in power transformer, such as interwire fault, transformer inrush, and fault in transformer connections. Simulation results were compared to experimental data, obtained with laboratory transformer, and showed satisfactory precision. Presented model allows calculation of transformer fault currents and analysis of other transients, such as inrush and overload.
- 1 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 641-644
Transformer fault analysis using instantaneous symmetrical components
Symmetrical components analysis of time-dependent variables is a well-known tool for calculation of power quality in electrical grids. This paper deals with analysis of power transformer internal faults by means of time-dependent symmetrical components of currents. Described method allows calculation of symmetrical components during transient and under non-sinusoidal conditions. Those components were implemented in relay protection algorithms for identification of internal faults in transformers. Various examples of transformer faults were studied and illustrated.
- 1 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 641-644
Transformer fault analysis using instantaneous symmetrical components
Symmetrical components analysis of time-dependent variables is a well-known tool for calculation of power quality in electrical grids. This paper deals with analysis of power transformer internal faults by means of time-dependent symmetrical components of currents. Described method allows calculation of symmetrical components during transient and under non-sinusoidal conditions. Those components were implemented in relay protection algorithms for identification of internal faults in transformers. Various examples of transformer faults were studied and illustrated.
- 1 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 636-640
Analysis of Z-source inverter control system for asynchronous drive for gas compressor
The article deals with the comparison of Z-source inverter based control systems for the asynchronous drive of gas compressor that is used in oil and gas industry. The relevance of the task is highlighted by the fact that choice of control system determines the reliability and the efficiency of gas system drive. Two types of indirect DC-link voltage control techniques were examined in order to estimate operation effectiveness of control system in dynamic modes. For that purpose simulation model of ZSI fed by induction motor, based on state space averaged modeling method, has been developed utilizing MATLAB/Simulink environment. The simulation results of dynamic performance of the ZSI with single-loop and dual-loop capacitor voltage control techniques during input voltage changes and steady state operations are presented and analyzed.
- 1 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 636-640
Analysis of Z-source inverter control system for asynchronous drive for gas compressor
The article deals with the comparison of Z-source inverter based control systems for the asynchronous drive of gas compressor that is used in oil and gas industry. The relevance of the task is highlighted by the fact that choice of control system determines the reliability and the efficiency of gas system drive. Two types of indirect DC-link voltage control techniques were examined in order to estimate operation effectiveness of control system in dynamic modes. For that purpose simulation model of ZSI fed by induction motor, based on state space averaged modeling method, has been developed utilizing MATLAB/Simulink environment. The simulation results of dynamic performance of the ZSI with single-loop and dual-loop capacitor voltage control techniques during input voltage changes and steady state operations are presented and analyzed.
- Open Access
- 1 February 2017
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 177 (1) , 012070
Simulation of switching overvoltages in the mine electric power supply system
Overvoltages occur in mine power supply systems during switching off consumers with high inductive load, such as transformers, reactors and electrical machines. Overvoltages lead to an increase of insulation degradation rate and may cause electric faults, power outage, fire and explosion of methane and coal dust. This paper is dedicated to simulation of vacuum circuit breaker switching overvoltages in a mine power supply system by means of Simulink MATLAB. The model of the vacuum circuit breaker implements simulation of transient recovery voltage, current chopping and an electric arc. Obtained results were compared to available experimental data.
- 1 February 2017
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 177 (1) , 012070
Open AccessSimulation of switching overvoltages in the mine electric power supply system
Overvoltages occur in mine power supply systems during switching off consumers with high inductive load, such as transformers, reactors and electrical machines. Overvoltages lead to an increase of insulation degradation rate and may cause electric faults, power outage, fire and explosion of methane and coal dust. This paper is dedicated to simulation of vacuum circuit breaker switching overvoltages in a mine power supply system by means of Simulink MATLAB. The model of the vacuum circuit breaker implements simulation of transient recovery voltage, current chopping and an electric arc. Obtained results were compared to available experimental data.
- 1 January 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 873-876
Simulation of switching overvoltage in mine production unit
The problem of overvoltage is particularly important for underground coal mine electric power supply systems as degradation of insulation may lead to electric faults, power outages, fire and explosion of methane and coal dust. This paper is dedicated to simulation of overvoltage in vacuum circuit breaker caused by emergency deenergization of mine production unit. A computer model of the vacuum circuit breaker was made in Simulink MATLAB in order to estimate possible overvoltage level and electric power quality problems. The model of circuit breaker represents processes in switching off vacuum breaker, such as arc ignition, existence of chopping current, electric arc and arc re-ignition in case of insufficient recovery voltage. Developed model of vacuum breaker was applied for simulation of overvoltage in mine production unit as a part of the mine electric power system model.
- 1 January 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 873-876
Simulation of switching overvoltage in mine production unit
The problem of overvoltage is particularly important for underground coal mine electric power supply systems as degradation of insulation may lead to electric faults, power outages, fire and explosion of methane and coal dust. This paper is dedicated to simulation of overvoltage in vacuum circuit breaker caused by emergency deenergization of mine production unit. A computer model of the vacuum circuit breaker was made in Simulink MATLAB in order to estimate possible overvoltage level and electric power quality problems. The model of circuit breaker represents processes in switching off vacuum breaker, such as arc ignition, existence of chopping current, electric arc and arc re-ignition in case of insufficient recovery voltage. Developed model of vacuum breaker was applied for simulation of overvoltage in mine production unit as a part of the mine electric power system model.
- 31 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 273-276
Vacuum breaker simulation for switching overvoltage study
Overvoltage is one of the most common types of electrical interferences in power supply systems. Significant part of overvoltages is caused by switching off the high inductive load, such as transformers, reactors and electrical machines. This paper is dedicated to vacuum circuit breakers switching off process modeling in Simulink MATLAB for the purpose of power quality problems estimation. Model of the vacuum circuit breaker implements simulation of transient recovery voltage, current chopping and electrical arc. Developed model was used for simulation of overvoltage on example of mine electric power system. Obtained results were compared to available experimental data.
- 31 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 273-276
Vacuum breaker simulation for switching overvoltage study
Overvoltage is one of the most common types of electrical interferences in power supply systems. Significant part of overvoltages is caused by switching off the high inductive load, such as transformers, reactors and electrical machines. This paper is dedicated to vacuum circuit breakers switching off process modeling in Simulink MATLAB for the purpose of power quality problems estimation. Model of the vacuum circuit breaker implements simulation of transient recovery voltage, current chopping and electrical arc. Developed model was used for simulation of overvoltage on example of mine electric power system. Obtained results were compared to available experimental data.
- 1 May 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Identification of hybrid wind power unit control parametrs for the purpose of loses optimization
The efficiency of autonomous power supply systems based on hybrid wind power plants depends on many factors, both climatic and cost-related. This paper is describes the usage of DC bus voltage as control system variable in order to minimize loses in those systems. In order to evaluate possible regulation range of DC voltage the evaluation of hybrid wind power battery voltage level which would ensure maximum these systems efficiency of generating system in case of variable wind speeds is required. This task was achieved by means of computer simulation of the hybrid wind power unit operating modes for various wind conditions.
- 1 May 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Identification of hybrid wind power unit control parametrs for the purpose of loses optimization
The efficiency of autonomous power supply systems based on hybrid wind power plants depends on many factors, both climatic and cost-related. This paper is describes the usage of DC bus voltage as control system variable in order to minimize loses in those systems. In order to evaluate possible regulation range of DC voltage the evaluation of hybrid wind power battery voltage level which would ensure maximum these systems efficiency of generating system in case of variable wind speeds is required. This task was achieved by means of computer simulation of the hybrid wind power unit operating modes for various wind conditions.
- 1 December 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Hybrid wind power unit operating modes simulation
For implementation of autonomous power supply systems based on wind power plants the validation of the main parameters is required, as the efficiency of generating unit in each specific case depends on many factors, both climatic and cost-related. This paper is dedicated to evaluation of hybrid wind power battery voltage which would ensure maximum efficiency of generating system in case of variable wind speeds. This task was achieved by means of computer simulation of the hybrid wind power unit operating modes for various wind conditions.
- 1 December 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Hybrid wind power unit operating modes simulation
For implementation of autonomous power supply systems based on wind power plants the validation of the main parameters is required, as the efficiency of generating unit in each specific case depends on many factors, both climatic and cost-related. This paper is dedicated to evaluation of hybrid wind power battery voltage which would ensure maximum efficiency of generating system in case of variable wind speeds. This task was achieved by means of computer simulation of the hybrid wind power unit operating modes for various wind conditions.