Eva N. Gimenez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Eva N. Gimenez has a total of 201 co-authors. Here are the top co-authors by number of shared publications:
N. Tartoni
Diamond Light Source, Ltd., Didcot, OX11 0DE, United Kingdom
9 shared publicationsJ Marchal
Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire, OX11 0DE, United Kingdom
8 shared publicationsN Tartoni
Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire, OX11 0DE, United Kingdom
8 shared publicationsD. Maneuski
SUPA School of Physics and Astronomy, University of Glasgow, G12 8QQ, United Kingdom
6 shared publications- Filomeno Sanchez
Instituto de Instrumentación para Imagen Molecular (I3M), Centro Mixto CSIC—Universitat Politècnica de València, Camino de Vera s/n, 46022 Valencia, Spain
6 shared publications I Horswell
Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire, OX11 0DE, United Kingdom
6 shared publications
Latest Publications
- Open Access
- 1 November 2022
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 17 (11) , C11003
X-ray detectors at Diamond Light Source, evolution and future challenges
This note shows the evolution of detectors for crystallography at Diamond Light Source since it came into operation and how this evolution shaped the way the experiments are done. It is also highlighted the next detector challenges due to the increase in photon flux related to the planned upgrade of the machine.
- 1 November 2022
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 17 (11) , C11003
Open AccessX-ray detectors at Diamond Light Source, evolution and future challenges
This note shows the evolution of detectors for crystallography at Diamond Light Source since it came into operation and how this evolution shaped the way the experiments are done. It is also highlighted the next detector challenges due to the increase in photon flux related to the planned upgrade of the machine.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
The ExcaliburRX-3M X-Ray Photon Counting Area Detector for Coherent Diffraction Imaging at the I13 Beamline at Diamond Light Source
A three million pixel photon counting large area detector has been commissioned for the coherent diffraction imaging beamline (I13) of Diamond Light Source. Challenging requirements of small pixel size, large area and fast frame rates required the construction of a detector based upon a tiling of a large number of the latest generation of the Medipix family of photon counting ASICs, Medipix3RX and a highly parallel readout system based upon the Front End Module cards developed by STFC. Such a detector provides a significant improvement in field of view whilst maintaining the resolution afforded by the small pixel size, when compared to previously available Medipix-based detectors such as the quad-chip Merlin. A number of commissioning experiments have been performed on the beamline, and this Conference Record provides intial results from these measurements and determines the capabilities of the detector and beamline system.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
The ExcaliburRX-3M X-Ray Photon Counting Area Detector for Coherent Diffraction Imaging at the I13 Beamline at Diamond Light Source
A three million pixel photon counting large area detector has been commissioned for the coherent diffraction imaging beamline (I13) of Diamond Light Source. Challenging requirements of small pixel size, large area and fast frame rates required the construction of a detector based upon a tiling of a large number of the latest generation of the Medipix family of photon counting ASICs, Medipix3RX and a highly parallel readout system based upon the Front End Module cards developed by STFC. Such a detector provides a significant improvement in field of view whilst maintaining the resolution afforded by the small pixel size, when compared to previously available Medipix-based detectors such as the quad-chip Merlin. A number of commissioning experiments have been performed on the beamline, and this Conference Record provides intial results from these measurements and determines the capabilities of the detector and beamline system.
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Timepix3 readout system for time resolved experiments at synchrotron radiation facilities
Demand for time resolved experiments, of which the time information related to the detected events is an essential requirement, is rapidly increasing in synchrotron research experiments. Timepix3 is a read-out chip for pixelated detectors that places a time stamp to every detected event with a nominal resolution of 1.5625 ns and provides a measure of the energy of the same event by the Time over Threshold technique. Timepix3 can then be a promising readout chip for time resolved experiments. A prototype of a Timepix3 readout system, based on a modified version of the MERLIN readout system, has already been developed by the detector group of Diamond Light Source (DLS). This prototype was used to run a set of characterization measurements using synchrotron radiation with the Timepix3 chip. The results of the characterization measurements proposed additional modifications to optimize the Timepix3 detector system to be used for time resolved experiments. The Timepix3 detector system needs to allow longer measurable time period for the Time of Arrival since it is limited by the small amount of bits dedicated. There is a need as well for locking the clock of the readout system to the source clock in order to avoid beats due to independent frequencies and track eventual deviations from nominal clock values. Development on the readout system, mainly on the FPGA firmware, has been carried out in order to increase the number of bits dedicated to the Time of Arrival. The possibility to synchronize the detector system using external clock was added.
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Timepix3 readout system for time resolved experiments at synchrotron radiation facilities
Demand for time resolved experiments, of which the time information related to the detected events is an essential requirement, is rapidly increasing in synchrotron research experiments. Timepix3 is a read-out chip for pixelated detectors that places a time stamp to every detected event with a nominal resolution of 1.5625 ns and provides a measure of the energy of the same event by the Time over Threshold technique. Timepix3 can then be a promising readout chip for time resolved experiments. A prototype of a Timepix3 readout system, based on a modified version of the MERLIN readout system, has already been developed by the detector group of Diamond Light Source (DLS). This prototype was used to run a set of characterization measurements using synchrotron radiation with the Timepix3 chip. The results of the characterization measurements proposed additional modifications to optimize the Timepix3 detector system to be used for time resolved experiments. The Timepix3 detector system needs to allow longer measurable time period for the Time of Arrival since it is limited by the small amount of bits dedicated. There is a need as well for locking the clock of the readout system to the source clock in order to avoid beats due to independent frequencies and track eventual deviations from nominal clock values. Development on the readout system, mainly on the FPGA firmware, has been carried out in order to increase the number of bits dedicated to the Time of Arrival. The possibility to synchronize the detector system using external clock was added.
- 1 July 2016
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 824, 101-103
Development of a Schottky CdTe Medipix3RX hybrid photon counting detector with spatial and energy resolving capabilities
- 1 July 2016
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 824, 101-103
Development of a Schottky CdTe Medipix3RX hybrid photon counting detector with spatial and energy resolving capabilities
- 3 February 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 63 (1) , 252-258
Evaluation of Polarization Effects of e-Collection Schottky CdTe Medipix3RX Hybrid Pixel Detector
This paper focuses on the evaluation of operational conditions such as temperature, exposure time and flux on the polarization of a Schottky electron collection CdTe detector. A Schottky e - collection CdTe Medipix3RX hybrid pixel detector was developed as a part of the CALIPSO-HIZPAD2 EU project. The 128 ×128 pixel matrix and 0.75 mm thick CdTe sensor bump-bonded to Medipix3RX readout chips enabled the study of the polarization effects. Single and quad module Medipix3RX chips were used which had 128 ×128 and 256 ×256 pixel matrices, respectively. This study reports the sensor-level and pixel-level polarization effects of the detector obtained from a laboratory X-ray source. We report that the sensor-level polarization is highly dependent on temperature, flux and exposure time. Furthermore, the study of pixel-level polarization effects led to identification of a new type of pixel behaviour that is characterised by three distinct phases and, thus, named “tri-phase” (3-P) pixels. The 3-P pixels were the dominant cause of degradation of the flat-field image uniformity under high flux operation. A new method of identifying the optimum operational conditions that utilises a criterion related to the 3-P pixels is proposed. A generated optimum operational conditions chart under the new method is reported. The criterion is used for bias voltage reset depolarization of the detector. The method successfully represented the dependency of polarization on temperature, flux and exposure time and was reproducible for multiple sensors. Operating the detector under the 3-P pixel criterion resulted in the total efficiency not falling below 95%.
- 3 February 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 63 (1) , 252-258
Evaluation of Polarization Effects of e-Collection Schottky CdTe Medipix3RX Hybrid Pixel Detector
This paper focuses on the evaluation of operational conditions such as temperature, exposure time and flux on the polarization of a Schottky electron collection CdTe detector. A Schottky e - collection CdTe Medipix3RX hybrid pixel detector was developed as a part of the CALIPSO-HIZPAD2 EU project. The 128 ×128 pixel matrix and 0.75 mm thick CdTe sensor bump-bonded to Medipix3RX readout chips enabled the study of the polarization effects. Single and quad module Medipix3RX chips were used which had 128 ×128 and 256 ×256 pixel matrices, respectively. This study reports the sensor-level and pixel-level polarization effects of the detector obtained from a laboratory X-ray source. We report that the sensor-level polarization is highly dependent on temperature, flux and exposure time. Furthermore, the study of pixel-level polarization effects led to identification of a new type of pixel behaviour that is characterised by three distinct phases and, thus, named “tri-phase” (3-P) pixels. The 3-P pixels were the dominant cause of degradation of the flat-field image uniformity under high flux operation. A new method of identifying the optimum operational conditions that utilises a criterion related to the 3-P pixels is proposed. A generated optimum operational conditions chart under the new method is reported. The criterion is used for bias voltage reset depolarization of the detector. The method successfully represented the dependency of polarization on temperature, flux and exposure time and was reproducible for multiple sensors. Operating the detector under the 3-P pixel criterion resulted in the total efficiency not falling below 95%.
- 3 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 62 (3) , 1413-1421
Medipix3RX: Characterizing the Medipix3 Redesign With Synchrotron Radiation
The Medipix3RX is the latest version of the Medipix3 photon counting ASICs, which implements two new operational modes, with respect to the Medipix2 ASIC, aimed at eliminating charge shared events (referred to as Charge Summing Mode (CSM)) and at providing spectroscopic information (referred to as Colour Mode (CM)). The Medipix3RX is a redesign of the Medipix3v0 ASIC and corrects for the underperformance of CSM features observed in the previous version. This paper presents the results from synchrotron X-rays tests to evaluate the Medipix3RX ASIC performance. The newly implemented CSM algorithm eliminates the charge sharing effect at the same time as allocating the event to the readout pixel corresponding to the sensor pixel where the X-ray photon impinged. The new pixel trimming circuit led to a reduced dispersion between pixels. Further results of the linearity for all the gain modes, energy resolution and pixel uniformity are also presented.
- 3 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 62 (3) , 1413-1421
Medipix3RX: Characterizing the Medipix3 Redesign With Synchrotron Radiation
The Medipix3RX is the latest version of the Medipix3 photon counting ASICs, which implements two new operational modes, with respect to the Medipix2 ASIC, aimed at eliminating charge shared events (referred to as Charge Summing Mode (CSM)) and at providing spectroscopic information (referred to as Colour Mode (CM)). The Medipix3RX is a redesign of the Medipix3v0 ASIC and corrects for the underperformance of CSM features observed in the previous version. This paper presents the results from synchrotron X-rays tests to evaluate the Medipix3RX ASIC performance. The newly implemented CSM algorithm eliminates the charge sharing effect at the same time as allocating the event to the readout pixel corresponding to the sensor pixel where the X-ray photon impinged. The new pixel trimming circuit led to a reduced dispersion between pixels. Further results of the linearity for all the gain modes, energy resolution and pixel uniformity are also presented.
- Open Access
- 1 March 2015
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 10 (03) , P03018
Edge pixel response studies of edgeless silicon sensor technology for pixellated imaging detectors
Silicon sensor technologies with reduced dead area at the sensor's perimeter are under development at a number of institutes. Several fabrication methods for sensors which are sensitive close to the physical edge of the device are under investigation utilising techniques such as active-edges, passivated edges and current-terminating rings. Such technologies offer the goal of a seamlessly tiled detection surface with minimum dead space between the individual modules. In order to quantify the performance of different geometries and different bulk and implant types, characterisation of several sensors fabricated using active-edge technology were performed at the B16 beam line of the Diamond Light Source. The sensors were fabricated by VTT and bump-bonded to Timepix ROICs. They were 100 and 200 μ m thick sensors, with the last pixel-to-edge distance of either 50 or 100 μ m . The sensors were fabricated as either n-on-n or n-on-p type devices. Using 15 keV monochromatic X-rays with a beam spot of 2.5 μ m , the performance at the outer edge and corners pixels of the sensors was evaluated at three bias voltages. The results indicate a significant change in the charge collection properties between the edge and 5th (up to 275 μ m ) from edge pixel for the 200 μ m thick n-on-n sensor. The edge pixel performance of the 100 μ m thick n-on-p sensors is affected only for the last two pixels (up to 110 μ m ) subject to biasing conditions. Imaging characteristics of all sensor types investigated are stable over time and the non-uniformities can be minimised by flat-field corrections. The results from the synchrotron tests combined with lab measurements are presented along with an explanation of the observed effects.
- 1 March 2015
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 10 (03) , P03018
Open AccessEdge pixel response studies of edgeless silicon sensor technology for pixellated imaging detectors
Silicon sensor technologies with reduced dead area at the sensor's perimeter are under development at a number of institutes. Several fabrication methods for sensors which are sensitive close to the physical edge of the device are under investigation utilising techniques such as active-edges, passivated edges and current-terminating rings. Such technologies offer the goal of a seamlessly tiled detection surface with minimum dead space between the individual modules. In order to quantify the performance of different geometries and different bulk and implant types, characterisation of several sensors fabricated using active-edge technology were performed at the B16 beam line of the Diamond Light Source. The sensors were fabricated by VTT and bump-bonded to Timepix ROICs. They were 100 and 200 μ m thick sensors, with the last pixel-to-edge distance of either 50 or 100 μ m . The sensors were fabricated as either n-on-n or n-on-p type devices. Using 15 keV monochromatic X-rays with a beam spot of 2.5 μ m , the performance at the outer edge and corners pixels of the sensors was evaluated at three bias voltages. The results indicate a significant change in the charge collection properties between the edge and 5th (up to 275 μ m ) from edge pixel for the 200 μ m thick n-on-n sensor. The edge pixel performance of the 100 μ m thick n-on-p sensors is affected only for the last two pixels (up to 110 μ m ) subject to biasing conditions. Imaging characteristics of all sensor types investigated are stable over time and the non-uniformities can be minimised by flat-field corrections. The results from the synchrotron tests combined with lab measurements are presented along with an explanation of the observed effects.
- Open Access
- 28 August 2014
- Published by Optica Publishing Group in Optics Express
- Vol. 22 (18) , 21508-21520
X-ray Bragg magnifier microscope as a linear shift invariant imaging system: image formation and phase retrieval
We present the theoretical description of the image formation with the in-line germanium Bragg Magnifier Microscope (BMM) and the first successful phase retrieval of X-ray holograms recorded with this imaging system. The conditions under which the BMM acts as a linear shift invariant system are theoretically explained and supported by the experiment. Such an approach simplifies the mathematical treatment of the image formation and reconstruction as complicated propagation of the wavefront onto inclined planes can be avoided. Quantitative phase retrieval is demonstrated using a test sample and a proof of concept phase imaging of a spider leg is also presented.
- 28 August 2014
- Published by Optica Publishing Group in Optics Express
- Vol. 22 (18) , 21508-21520
Open AccessX-ray Bragg magnifier microscope as a linear shift invariant imaging system: image formation and phase retrieval
We present the theoretical description of the image formation with the in-line germanium Bragg Magnifier Microscope (BMM) and the first successful phase retrieval of X-ray holograms recorded with this imaging system. The conditions under which the BMM acts as a linear shift invariant system are theoretically explained and supported by the experiment. Such an approach simplifies the mathematical treatment of the image formation and reconstruction as complicated propagation of the wavefront onto inclined planes can be avoided. Quantitative phase retrieval is demonstrated using a test sample and a proof of concept phase imaging of a spider leg is also presented.
- 1 May 2014
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 9 (5) , C05007
Comparisons between simulation and measurements taken with the Medipix3RX detector
A simulation toolkit developed for use at Diamond Light Source is presented, accompanied with experimental validation using a silicon pixel-array sensor coupled to a Medipix3RX chip controlled via the Merlin Readout System. The simulation makes use of Geant4, where photons are tracked in order to determine their position of interaction and energy deposition. Further to this, a Finite Element Methods package, Comsol, is used to model the Charge Induction Efficiencies of various sensors. Results are coupled to Geant4 simulations to provide an accurate method for computing the signals generated on each pixel within the sensor and then an algorithm to model the front-end electronics of the device. The validity of the simulation toolkit is tested by investigating charge-sharing effects using a Medipix3RX chip bump-bonded to a silicon pixel-array sensor. The dependence of the imaging parameters, on the energy threshold, is presented from both simulation and experiment for the Medipix3RX chip operated with and without the charge sharing compensation circuitry enabled. This simulation toolkit can be used to calculate image quality parameters for the next generation of detectors, including CdTe, as well as to improve data corrections on existing detectors on synchrotron beamlines.
- 1 May 2014
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 9 (5) , C05007
Comparisons between simulation and measurements taken with the Medipix3RX detector
A simulation toolkit developed for use at Diamond Light Source is presented, accompanied with experimental validation using a silicon pixel-array sensor coupled to a Medipix3RX chip controlled via the Merlin Readout System. The simulation makes use of Geant4, where photons are tracked in order to determine their position of interaction and energy deposition. Further to this, a Finite Element Methods package, Comsol, is used to model the Charge Induction Efficiencies of various sensors. Results are coupled to Geant4 simulations to provide an accurate method for computing the signals generated on each pixel within the sensor and then an algorithm to model the front-end electronics of the device. The validity of the simulation toolkit is tested by investigating charge-sharing effects using a Medipix3RX chip bump-bonded to a silicon pixel-array sensor. The dependence of the imaging parameters, on the energy threshold, is presented from both simulation and experiment for the Medipix3RX chip operated with and without the charge sharing compensation circuitry enabled. This simulation toolkit can be used to calculate image quality parameters for the next generation of detectors, including CdTe, as well as to improve data corrections on existing detectors on synchrotron beamlines.