Veronika B. Rumer
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Veronika B. Rumer has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Aleksander Sergeevich Ametov
Russian Medical Academy of Continuous Professional Education
2 shared publications - Antonio K. Chekini
S.P. Botkin Multidisciplinary Clinical Medical Center
2 shared publications - Dmitriy N. Grekov
Botkin Hospital
2 shared publications - Evgeniya Yu. Pashkova
Botkin Hospital; Russian Medical Academy of Continuing Professional Education
2 shared publications - Konstantin S. Titov
Moscow Multidisciplinary Scientific and Clinical Center, Moscow Healthcare Department; RUDN University
2 shared publications - Maksim P. Onishchenko
S.P. Botkin City Clinical Hospital
2 shared publications
Latest Publications
- 30 October 2026
- Published by Media Sphere Publishing Group in P.A. Herzen Journal of Oncology
- Vol. 15 (5)
Retrospective analysis of safety and diagnostic efficacy of CT-guided robotic-assisted transthoracic lung biopsies
Objective. To analyze the safety and diagnostic value of transthoracic robot-assisted CT-guided lung tumor biopsy. Material and methods. A retrospective analysis of 537 biopsy procedures in patients with solid lung lesions ≥1 cm in diameter was conducted. Biopsies were performed under synchronized multislice CT guidance using the PERFINT MAXIO robotic navigation system. The yield of informative material, diagnostic parameters (sensitivity, specificity, accuracy), and complications assessed using the Clavien-Dindo scale were assessed. Results. Informative material was obtained in 91.8% of cases (493/537). The sensitivity of the method in verifying malignant tumors was 93.9% (95% CI 91.2—96.0%), specificity was 100% (95% CI 96.3—100%), accuracy was 95.1% (95% CI 92.9—96.8%). Complications developed in 15.5% of patients (83 patients): pneumothorax — in 11.0% (59 patients), of which drainage of the pleural cavity was required in 83.1% of cases (49 patients); hemothorax — in 2.8% (15 patients); hemoptysis — in 1.7% (9 patients). Complications of I-II degree (not requiring invasive interventions) were registered in 6.3% of patients. There were no fatal outcomes. No statistically significant differences in complication rates or diagnostic efficacy were found between 16G and 18G needles. Conclusion. CT-guided transthoracic robotic-assisted biopsy demonstrates high diagnostic accuracy (95.1%) and an acceptable safety profile, allowing it to be recommended for the verification of malignant lung tumors.
- 30 October 2026
- Published by Media Sphere Publishing Group in P.A. Herzen Journal of Oncology
- Vol. 15 (5)
Retrospective analysis of safety and diagnostic efficacy of CT-guided robotic-assisted transthoracic lung biopsies
Objective. To analyze the safety and diagnostic value of transthoracic robot-assisted CT-guided lung tumor biopsy. Material and methods. A retrospective analysis of 537 biopsy procedures in patients with solid lung lesions ≥1 cm in diameter was conducted. Biopsies were performed under synchronized multislice CT guidance using the PERFINT MAXIO robotic navigation system. The yield of informative material, diagnostic parameters (sensitivity, specificity, accuracy), and complications assessed using the Clavien-Dindo scale were assessed. Results. Informative material was obtained in 91.8% of cases (493/537). The sensitivity of the method in verifying malignant tumors was 93.9% (95% CI 91.2—96.0%), specificity was 100% (95% CI 96.3—100%), accuracy was 95.1% (95% CI 92.9—96.8%). Complications developed in 15.5% of patients (83 patients): pneumothorax — in 11.0% (59 patients), of which drainage of the pleural cavity was required in 83.1% of cases (49 patients); hemothorax — in 2.8% (15 patients); hemoptysis — in 1.7% (9 patients). Complications of I-II degree (not requiring invasive interventions) were registered in 6.3% of patients. There were no fatal outcomes. No statistically significant differences in complication rates or diagnostic efficacy were found between 16G and 18G needles. Conclusion. CT-guided transthoracic robotic-assisted biopsy demonstrates high diagnostic accuracy (95.1%) and an acceptable safety profile, allowing it to be recommended for the verification of malignant lung tumors.
- Open Access
- 1 January 2025
- Published by Geotar-Media Publishing Group in Endocrinology: News, Opinions, Training
- Vol. 14 (1)
Modern aspects of CT diagnostics of thyroid carcinoma
Современные аспекты КТ-диагностики карциномы щитовидной железы
- 1 January 2025
- Published by Geotar-Media Publishing Group in Endocrinology: News, Opinions, Training
- Vol. 14 (1)
Open AccessModern aspects of CT diagnostics of thyroid carcinoma
Современные аспекты КТ-диагностики карциномы щитовидной железы
- Open Access
- 25 December 2024
- Published by ECO-Vector LLC in Russian Journal of Oncology
- Vol. 29 (4) , 307-314
Experience of Computer Tomography Guided Robot-Assisted Transthoracic Lung Biopsy
BACKGROUND: The sensitivity of computer tomography (CT) guided transthoracic needle biopsy for the verification of lung tumors is reported to range from 74 to 90%. An augmented reality robotic navigation system for CT-guided percutaneous lung biopsy has been developed to facilitate more precise biopsy of lung lesions. The present study describes the authors’ experience with the navigation system for transthoracic lung biopsy. AIM: To analyze the safety and diagnostic value of performing a transthoracic biopsy of lung tumors using a robotic CT navigation system. MATERIALS AND METHODS: The study included a retrospective analysis of CT-guided robot-assisted transthoracic lung biopsy procedures performed in the Thoracic and Abdominal Surgical Oncology Department No. 72 of the Botkin Moscow General Scientific and Clinical Center between November 30, 2023 to April 04, 2024. A total of 104 patients were included in the study. The biopsy was performed following the developed algorithm. RESULTS: The specimens obtained were morphologically valuable in 91.8% of cases (n=101/110). A total of 1–4 specimens (tissue columns) were obtained from each patient during the biopsy procedure. Specifically, 1 specimen was obtained from 7 patients (6.4٪), 2 specimens from 57 patients (51.8٪), 3 specimens from 43 patients, and 4 specimens from 3 patients (2.7٪). Among the patients for whom morphologically valuable specimens were obtained (n=101), the diagnosis of malignant tumor was confirmed in 76 cases (75.2%). In all remaining cases (n=25, 24.8%), benign lesions or inflammatory/post-inflammatory changes were diagnosed. Complications of various severity degrees occurred in 17 cases (15.5%). No deaths were reported (0%). The findings revealed no statistically significant differences in the frequency of cases with a verified diagnosis based on the diameter of the biopsy needle (p=0.124). Furthermore, the analysis revealed no statistically significant effect of the diameter of the biopsy needle (16G or 18G) on the overall complication rate (18.2 and 9%, respectively; p=0.266) and the frequency of pleural drainage for postoperative pneumothorax (10.4 and 6%, respectively; p=0.72). CONCLUSIONS: The CT-guided robot-assisted transthoracic lung biopsy is a safe and effective technique for the morphological verification of malignant tumors.
- 25 December 2024
- Published by ECO-Vector LLC in Russian Journal of Oncology
- Vol. 29 (4) , 307-314
Open AccessExperience of Computer Tomography Guided Robot-Assisted Transthoracic Lung Biopsy
BACKGROUND: The sensitivity of computer tomography (CT) guided transthoracic needle biopsy for the verification of lung tumors is reported to range from 74 to 90%. An augmented reality robotic navigation system for CT-guided percutaneous lung biopsy has been developed to facilitate more precise biopsy of lung lesions. The present study describes the authors’ experience with the navigation system for transthoracic lung biopsy. AIM: To analyze the safety and diagnostic value of performing a transthoracic biopsy of lung tumors using a robotic CT navigation system. MATERIALS AND METHODS: The study included a retrospective analysis of CT-guided robot-assisted transthoracic lung biopsy procedures performed in the Thoracic and Abdominal Surgical Oncology Department No. 72 of the Botkin Moscow General Scientific and Clinical Center between November 30, 2023 to April 04, 2024. A total of 104 patients were included in the study. The biopsy was performed following the developed algorithm. RESULTS: The specimens obtained were morphologically valuable in 91.8% of cases (n=101/110). A total of 1–4 specimens (tissue columns) were obtained from each patient during the biopsy procedure. Specifically, 1 specimen was obtained from 7 patients (6.4٪), 2 specimens from 57 patients (51.8٪), 3 specimens from 43 patients, and 4 specimens from 3 patients (2.7٪). Among the patients for whom morphologically valuable specimens were obtained (n=101), the diagnosis of malignant tumor was confirmed in 76 cases (75.2%). In all remaining cases (n=25, 24.8%), benign lesions or inflammatory/post-inflammatory changes were diagnosed. Complications of various severity degrees occurred in 17 cases (15.5%). No deaths were reported (0%). The findings revealed no statistically significant differences in the frequency of cases with a verified diagnosis based on the diameter of the biopsy needle (p=0.124). Furthermore, the analysis revealed no statistically significant effect of the diameter of the biopsy needle (16G or 18G) on the overall complication rate (18.2 and 9%, respectively; p=0.266) and the frequency of pleural drainage for postoperative pneumothorax (10.4 and 6%, respectively; p=0.72). CONCLUSIONS: The CT-guided robot-assisted transthoracic lung biopsy is a safe and effective technique for the morphological verification of malignant tumors.
- Open Access
- 30 March 2024
- Published by Consilium Medicum in Terapevticheskii arkhiv
- Vol. 96 (2) , 147-152
Total duodenopancreatectomy: the role of a multidisciplinary team approach in successful treatment. Case report
In order to identify and correct concomitant diseases all patients undergo a comprehensive examination before surgical treatment. Rare concomitant diseases include primary chronic adrenal insufficiency. This clinical case presents the total duodenopancreatectomy in a patient with primary chronic adrenal insufficiency. Available algorithms are not always suitable in the treatment of such patients after surgical interventions, especially long-term and extensive. It is necessary to focus on laboratory parameters and the clinical picture. An individual and multidisciplinary approach to the treatment of patients with comorbid pathologies is important.
- 30 March 2024
- Published by Consilium Medicum in Terapevticheskii arkhiv
- Vol. 96 (2) , 147-152
Open AccessTotal duodenopancreatectomy: the role of a multidisciplinary team approach in successful treatment. Case report
In order to identify and correct concomitant diseases all patients undergo a comprehensive examination before surgical treatment. Rare concomitant diseases include primary chronic adrenal insufficiency. This clinical case presents the total duodenopancreatectomy in a patient with primary chronic adrenal insufficiency. Available algorithms are not always suitable in the treatment of such patients after surgical interventions, especially long-term and extensive. It is necessary to focus on laboratory parameters and the clinical picture. An individual and multidisciplinary approach to the treatment of patients with comorbid pathologies is important.
- Open Access
- 1 January 2023
- Published by Geotar-Media Publishing Group in Endocrinology: News, Opinions, Training
- Vol. 12 (4)
Diabetes mellitus and pancreatic cancer: a literature review
Сахарный диабет и рак поджелудочной железы: обзор литературы
- 1 January 2023
- Published by Geotar-Media Publishing Group in Endocrinology: News, Opinions, Training
- Vol. 12 (4)
Open AccessDiabetes mellitus and pancreatic cancer: a literature review
Сахарный диабет и рак поджелудочной железы: обзор литературы
- 18 May 2021
- Published by Vidar, Ltd. in Medical Visualization
- Vol. 25 (2) , 50-62
CT semiotics of traumatic and bon-traumatic spleen injures
Purpose. To demonstrate capabilities and features in spleen pathology diagnostics based on clinical experience of Botkin City Hospital. Materials and methods. The analysis of 89 patients with spleen abnormalities was performed in the term from 01/2014 till 08/2020. All the patients underwent computed tomography (CT) and/or magnetic resonance imaging (MRI) with contrast enhancing. All cases verified surgically and/or clinically. Results. There were 37 cases of trauma (42%). Accuracy and precision of the method was 100%. In detection of active bleeding the highest diagnostic accuracy (100%) was shown with extravasation symptom – 7 cases. In non-traumatic group (n = 52, 58%) two biggest sub-groups were abscesses (n = 19, 36% in this group) and infarctions (n = 15, 29%). There were 8 cases of cysts (15%), 3 of them – hydatid, 5 cases of spleen hemangiomas. (9.6%), 3 cases of spleen metastases (6%). There was 1 case of angiosarcoma (2%) and 1 case cystic lymphangioma (2%). Conclusion. The most frequent condition in spleen pathology, diagnosed in radiology department is trauma. In non-traumatic cases two biggest groups are abscesses and infarctions. CT features of spleen infarction are pyramidal wedge of hypoperfused splenic tissue with the apex pointing towards the hilum, and the base on the splenic capsule. In all cases in our study cysts were incidental findings. Spleen metastases are rare due to organ hemodynamics. The most rare lesions of the spleen are primal tumors.
- 18 May 2021
- Published by Vidar, Ltd. in Medical Visualization
- Vol. 25 (2) , 50-62
CT semiotics of traumatic and bon-traumatic spleen injures
Purpose. To demonstrate capabilities and features in spleen pathology diagnostics based on clinical experience of Botkin City Hospital. Materials and methods. The analysis of 89 patients with spleen abnormalities was performed in the term from 01/2014 till 08/2020. All the patients underwent computed tomography (CT) and/or magnetic resonance imaging (MRI) with contrast enhancing. All cases verified surgically and/or clinically. Results. There were 37 cases of trauma (42%). Accuracy and precision of the method was 100%. In detection of active bleeding the highest diagnostic accuracy (100%) was shown with extravasation symptom – 7 cases. In non-traumatic group (n = 52, 58%) two biggest sub-groups were abscesses (n = 19, 36% in this group) and infarctions (n = 15, 29%). There were 8 cases of cysts (15%), 3 of them – hydatid, 5 cases of spleen hemangiomas. (9.6%), 3 cases of spleen metastases (6%). There was 1 case of angiosarcoma (2%) and 1 case cystic lymphangioma (2%). Conclusion. The most frequent condition in spleen pathology, diagnosed in radiology department is trauma. In non-traumatic cases two biggest groups are abscesses and infarctions. CT features of spleen infarction are pyramidal wedge of hypoperfused splenic tissue with the apex pointing towards the hilum, and the base on the splenic capsule. In all cases in our study cysts were incidental findings. Spleen metastases are rare due to organ hemodynamics. The most rare lesions of the spleen are primal tumors.