Kengo Setta
Research Subjects
Kengo Setta has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Kuniaki Ogasawara
Department of Neurosurgery, School of Medicine, Iwate Medical University, Yahaba, Japan
4 shared publications - Makoto Sasaki
Iwate Tohoku Medical Megabank Organization, Disaster Reconstruction Center, Iwate Medical University, Yahaba, Japan
3 shared publications - Shunrou Fujiwara
From the Department of Neurosurgery (K.K., Y.A, K.F., M.K, T.K., K.Y., K.O.), the Centre for Division of Ultrahigh Field MRI, Institute for Biomedical Sciences (I.U., M.S), the Division of Molecular and Cellular Pharmacology, Department of Pathophysiology (S.F.), and the Cyclotron Research Center (K.T.), Iwate Medical University, Yahaba, Japan
3 shared publications - Masakazu Kobayashi
Toyota Technological Institute
2 shared publications - Takayuki Chiba
From the Department of Neurosurgery (K.S., T.C., S.F., M.K., K. Yoshida, Y. Kubo, K.O.), Institute for Biomedical Sciences, Iwate Medical University School of Medicine, Yahaba-cho, Japan
2 shared publications - Tsuyoshi Matsuda
Division of Ultrahigh Field MRI, Institute for Biomedical Sciences, Iwate Medical University, Shiwa Iwate, Japan
2 shared publications
Latest Publications
- Open Access
- 1 April 2024
- Published by KEAI Publishing in Brain Hemorrhages
- Vol. 5 (2) , 74-78
Fluid balance management with loop diuretics in patients with aneurysmal subarachnoid hemorrhage treated with clazosentan: A case series
- 1 April 2024
- Published by KEAI Publishing in Brain Hemorrhages
- Vol. 5 (2) , 74-78
Open AccessFluid balance management with loop diuretics in patients with aneurysmal subarachnoid hemorrhage treated with clazosentan: A case series
- 23 June 2022
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 43 (7) , 972-977
Assessment of Heating on Titanium Alloy Cerebral Aneurysm Clips during 7T MRI
BACKGROUND AND PURPOSE: Patients with cerebral aneurysms often undergo MR imaging after microsurgical clipping. Ultra-high-field MR imaging at 7T may provide high diagnostic capability in such clinical situations. However, titanium alloy clips have safety issues such as adverse interactions with static magnetic fields and radiofrequency-induced heating during 7T MR imaging. The purpose of this study was to quantitatively assess temperature increases on various types of titanium alloy aneurysm clips during 7T MR imaging. MATERIALS AND METHODS: Five types of titanium alloy aneurysm clips were tested, including combinations of short, long, straight, angled, and fenestrated types. Each clip was set in a phantom filled with gelled saline mixed with polyacrylic acid and underwent 7T MR imaging with 3D T1WI with a spoiled gradient recalled acquisition in the steady-state technique. Temperature was chronologically measured at the tips of the clip blade and head, angled part of the clip, and 5 mm from the tip of the clip head using MR imaging–compatible fiber-optic thermometers. RESULTS: Temperature increases at all locations for right-angled and short straight clips were 1°C. Temperature increases at all locations for the long straight clip were >2°C. CONCLUSIONS: Temperature increases on the right-angled and short straight clips remained below the regulatory limit during 7T MR imaging, but temperature increases on the 45° angled, straight fenestrated, and long straight clips exceeded this limit.
- 23 June 2022
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 43 (7) , 972-977
Assessment of Heating on Titanium Alloy Cerebral Aneurysm Clips during 7T MRI
BACKGROUND AND PURPOSE: Patients with cerebral aneurysms often undergo MR imaging after microsurgical clipping. Ultra-high-field MR imaging at 7T may provide high diagnostic capability in such clinical situations. However, titanium alloy clips have safety issues such as adverse interactions with static magnetic fields and radiofrequency-induced heating during 7T MR imaging. The purpose of this study was to quantitatively assess temperature increases on various types of titanium alloy aneurysm clips during 7T MR imaging. MATERIALS AND METHODS: Five types of titanium alloy aneurysm clips were tested, including combinations of short, long, straight, angled, and fenestrated types. Each clip was set in a phantom filled with gelled saline mixed with polyacrylic acid and underwent 7T MR imaging with 3D T1WI with a spoiled gradient recalled acquisition in the steady-state technique. Temperature was chronologically measured at the tips of the clip blade and head, angled part of the clip, and 5 mm from the tip of the clip head using MR imaging–compatible fiber-optic thermometers. RESULTS: Temperature increases at all locations for right-angled and short straight clips were 1°C. Temperature increases at all locations for the long straight clip were >2°C. CONCLUSIONS: Temperature increases on the right-angled and short straight clips remained below the regulatory limit during 7T MR imaging, but temperature increases on the 45° angled, straight fenestrated, and long straight clips exceeded this limit.
- 1 December 2021
- Published by Elsevier in Journal of Stroke and Cerebrovascular Diseases
- Vol. 30 (12) , 106107
Assessment of Impaired Cerebrovascular Reactivity in Chronic Cerebral Ischemia using Intravoxel Incoherent Motion Magnetic Resonance Imaging
- 1 December 2021
- Published by Elsevier in Journal of Stroke and Cerebrovascular Diseases
- Vol. 30 (12) , 106107
Assessment of Impaired Cerebrovascular Reactivity in Chronic Cerebral Ischemia using Intravoxel Incoherent Motion Magnetic Resonance Imaging
- 20 May 2021
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 42 (8) , 1403-1409
Diagnostic Accuracy of Screening Arterial Spin-Labeling MRI Using Hadamard Encoding for the Detection of Reduced CBF in Adult Patients with Ischemic Moyamoya Disease
BACKGROUND AND PURPOSE: Adult patients with ischemic Moyamoya disease are advised to undergo selective revascularization surgery based on cerebral hemodynamics. The purpose of this study was to determine the diagnostic accuracy of arterial spin-labeling MR imaging using Hadamard-encoded multiple postlabeling delays for the detection of reduced CBF in such patients. MATERIALS AND METHODS: Thirty-seven patients underwent brain perfusion SPECT and pseudocontinuous arterial spin-labeling MR imaging using standard postlabeling delay (1525 ms) and Hadamard-encoded multiple postlabeling delays. For Hadamard-encoded multiple postlabeling delays, based on data obtained from the 7 sub-boluses with combinations of different labeling durations and postlabeling delays, CBF corrected by the arterial transit time was calculated on a voxel-by-voxel basis. Using a 3D stereotaxic template, we automatically placed ROIs in the ipsilateral cerebellar hemisphere and 5 MCA territories in the symptomatic cerebral hemisphere; then, the ratio of the MCA to cerebellar ROI was calculated. RESULTS: The area under the receiver operating characteristic curve for detecting reduced SPECT-CBF ratios (P = .001). The sensitivity and negative predictive value for the Hadamard-encoded multiple postlabeling delays–CBF ratios were 100% (95% confidence interval, 100%–100%) and significantly higher than the sensitivity (95% CI, 44%–80%) and negative predictive value (95% CI, 88%–97%) for the standard postlabeling delay–CBF ratio, respectively. CONCLUSIONS: ASL MR imaging using Hadamard-encoded multiple postlabeling delays may be applicable as a screening tool because it can detect reduced CBF on brain perfusion SPECT with 100% sensitivity and a 100% negative predictive value in adult patients with ischemic Moyamoya disease.
- 20 May 2021
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 42 (8) , 1403-1409
Diagnostic Accuracy of Screening Arterial Spin-Labeling MRI Using Hadamard Encoding for the Detection of Reduced CBF in Adult Patients with Ischemic Moyamoya Disease
BACKGROUND AND PURPOSE: Adult patients with ischemic Moyamoya disease are advised to undergo selective revascularization surgery based on cerebral hemodynamics. The purpose of this study was to determine the diagnostic accuracy of arterial spin-labeling MR imaging using Hadamard-encoded multiple postlabeling delays for the detection of reduced CBF in such patients. MATERIALS AND METHODS: Thirty-seven patients underwent brain perfusion SPECT and pseudocontinuous arterial spin-labeling MR imaging using standard postlabeling delay (1525 ms) and Hadamard-encoded multiple postlabeling delays. For Hadamard-encoded multiple postlabeling delays, based on data obtained from the 7 sub-boluses with combinations of different labeling durations and postlabeling delays, CBF corrected by the arterial transit time was calculated on a voxel-by-voxel basis. Using a 3D stereotaxic template, we automatically placed ROIs in the ipsilateral cerebellar hemisphere and 5 MCA territories in the symptomatic cerebral hemisphere; then, the ratio of the MCA to cerebellar ROI was calculated. RESULTS: The area under the receiver operating characteristic curve for detecting reduced SPECT-CBF ratios (P = .001). The sensitivity and negative predictive value for the Hadamard-encoded multiple postlabeling delays–CBF ratios were 100% (95% confidence interval, 100%–100%) and significantly higher than the sensitivity (95% CI, 44%–80%) and negative predictive value (95% CI, 88%–97%) for the standard postlabeling delay–CBF ratio, respectively. CONCLUSIONS: ASL MR imaging using Hadamard-encoded multiple postlabeling delays may be applicable as a screening tool because it can detect reduced CBF on brain perfusion SPECT with 100% sensitivity and a 100% negative predictive value in adult patients with ischemic Moyamoya disease.