GTGerardo Tibamoso-Pedraza

Gerardo Tibamoso-Pedraza

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Gerardo Tibamoso-Pedraza has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Navigation guidance for ventricular septal defect closure in heart phantoms

    by Gerardo Tibamoso-Pedraza, Sarah Amouri, Victor Molina, Iñaki Navarro, Marie-Josée Raboisson, Joaquim Miró, Chantale Lapierre, Sylvie Ratté, Luc Duong

    Purpose Transesophageal echocardiography (TEE) is the preferred imaging modality in a hybrid procedure used to close ventricular septal defects (VSDs). However, the limited field of view of TEE hinders the maneuvering of surgical instruments inside the beating heart. This study evaluates the accuracy of a method that aims to support navigation guidance in the hybrid procedure. Methods A cardiologist maneuvered a needle to puncture the patient’s heart and to access a VSD, guided by information displayed in a virtual environment. The information displayed included a model of the patient’s heart and a virtual needle that reproduced the position and orientation of the real needle in real time. The physical and the virtual worlds were calibrated with a landmark registration and an iterative closest point algorithms, using an electromagnetic measurement system (EMS). For experiments, we developed a setup that included heart phantoms representing the patient’s heart. Results Experimental results from two pediatric cases studied suggested that the information provided for guidance was accurate enough when the landmark registration algorithm was fed with coordinates of seven points clearly identified on the surfaces of the physical and virtual hearts. Indeed, with a registration error of 2.28 mm RMS, it was possible to successfully access two VSDs (6.2 mm and 6.3 mm in diameter) in all the attempts with a needle (5 attempts) and a guidewire (7 attempts). Conclusion We found that information provided in a virtual environment facilitates guidance in the hybrid procedure for VSD closure. A clear identification of anatomical details in the heart surfaces is key to the accuracy of the procedure.


  • Design of heart phantoms for ultrasound imaging of ventricular septal defects

    by Gerardo Tibamoso-Pedraza, Iñaki Navarro, Patrice Dion, Marie-Josée Raboisson, Chantale Lapierre, Joaquim Miró, Sylvie Ratté, Luc Duong

    Purpose Ventricular septal defects (VSDs) are common congenital heart malformations. Echocardiography used during VSD hybrid cardiac procedures requires extensive training for image acquisition and interpretation. Cardiac surgery simulators with heart phantoms have shown usefulness for such training, but they are limited in visualization and characterization of complex VSD. This study explores a new method to build patient-specific heart phantoms with VSD, with proper tissue echogenicity for ultrasound imaging. Methods Heart phantoms were designed from preoperative imaging of three patients with complex VSDs. Each whole heart phantom, including atrial and ventricular septums, was obtained by manual segmentation and by surface reconstruction, then by molding and by casting in different materials. Heart phantoms in silicone and polyvinyl alcohol cryogel (PVA-C) were considered, and they were reconstructed in 3-D using 2-D freehand ultrasound imaging. Results An electromagnetic measurement system was used to measure the mean VSD diameters from the heart phantoms. Errors were evaluated below 1.0 mm for mean VSD diameters between 6.2 and 7.5 mm. Conclusion Patient-specific heart phantoms promise for representing complex heart malformations such as VSDs. PVA-C showed better tissue echogenicity than silicone for VSDs visualization and characterization.