Iñaki Navarro
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Iñaki Navarro has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Chantale Lapierre
Cardiology, Department of Pediatrics, CHU Sainte-Justine, Montreal, Canada
1 shared publication - Gerardo Tibamoso-Pedraza
Interventional Imaging Lab, Department of Software and IT Engineering, École de technologie supérieure, Montreal, Canada
1 shared publication - Joaquim Miró
Cardiology, Department of Pediatrics, CHU Sainte-Justine, Montreal, Canada
1 shared publication - Luc Duong
Department of Software and IT Engineering, École de Technologie Supérieure, Montreal, Canada
1 shared publication - Marie-Josée Raboisson
Cardiology, Department of Pediatrics, CHU Sainte-Justine, Montreal, Canada
1 shared publication - Sarah Amouri
Interventional Imaging Lab, Department of Software and IT Engineering, École de technologie supérieure, Montreal, Canada
1 shared publication
Latest Publications
- 7 July 2022
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 17 (10) , 1947-1956
Navigation guidance for ventricular septal defect closure in heart phantoms
Purpose Transesophageal echocardiography (TEE) is the preferred imaging modality in a hybrid procedure used to close ventricular septal defects (VSDs). However, the limited field of view of TEE hinders the maneuvering of surgical instruments inside the beating heart. This study evaluates the accuracy of a method that aims to support navigation guidance in the hybrid procedure. Methods A cardiologist maneuvered a needle to puncture the patient’s heart and to access a VSD, guided by information displayed in a virtual environment. The information displayed included a model of the patient’s heart and a virtual needle that reproduced the position and orientation of the real needle in real time. The physical and the virtual worlds were calibrated with a landmark registration and an iterative closest point algorithms, using an electromagnetic measurement system (EMS). For experiments, we developed a setup that included heart phantoms representing the patient’s heart. Results Experimental results from two pediatric cases studied suggested that the information provided for guidance was accurate enough when the landmark registration algorithm was fed with coordinates of seven points clearly identified on the surfaces of the physical and virtual hearts. Indeed, with a registration error of 2.28 mm RMS, it was possible to successfully access two VSDs (6.2 mm and 6.3 mm in diameter) in all the attempts with a needle (5 attempts) and a guidewire (7 attempts). Conclusion We found that information provided in a virtual environment facilitates guidance in the hybrid procedure for VSD closure. A clear identification of anatomical details in the heart surfaces is key to the accuracy of the procedure.
- 7 July 2022
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 17 (10) , 1947-1956
Navigation guidance for ventricular septal defect closure in heart phantoms
Purpose Transesophageal echocardiography (TEE) is the preferred imaging modality in a hybrid procedure used to close ventricular septal defects (VSDs). However, the limited field of view of TEE hinders the maneuvering of surgical instruments inside the beating heart. This study evaluates the accuracy of a method that aims to support navigation guidance in the hybrid procedure. Methods A cardiologist maneuvered a needle to puncture the patient’s heart and to access a VSD, guided by information displayed in a virtual environment. The information displayed included a model of the patient’s heart and a virtual needle that reproduced the position and orientation of the real needle in real time. The physical and the virtual worlds were calibrated with a landmark registration and an iterative closest point algorithms, using an electromagnetic measurement system (EMS). For experiments, we developed a setup that included heart phantoms representing the patient’s heart. Results Experimental results from two pediatric cases studied suggested that the information provided for guidance was accurate enough when the landmark registration algorithm was fed with coordinates of seven points clearly identified on the surfaces of the physical and virtual hearts. Indeed, with a registration error of 2.28 mm RMS, it was possible to successfully access two VSDs (6.2 mm and 6.3 mm in diameter) in all the attempts with a needle (5 attempts) and a guidewire (7 attempts). Conclusion We found that information provided in a virtual environment facilitates guidance in the hybrid procedure for VSD closure. A clear identification of anatomical details in the heart surfaces is key to the accuracy of the procedure.