Siti Nurul Fasehah Ismail
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Siti Nurul Fasehah Ismail has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Arman Shah
Faculty of Technical and Vocational, Universiti Pendidikan Sultan Idris, 35900 Tanjong Malim, Perak, Malaysia
4 shared publications - Roswanira Abdul Wahab
Department of Chemistry, Faculty of Science, Universiti Teknologi Malaysia (UTM), Johor Bahru, Malaysia
4 shared publications F. Huyop
3 shared publicationsM.F. Edbeib
Bani Walid Univ, Dept Anim Prod, Fac Agr, Bani Walid, Libya
2 shared publicationsA. Retnoningsih
1 shared publicationAidil Abdul Hamid
1 shared publication
Latest Publications
- Open Access
- 1 September 2018
- Published by Malaysian Journal of Microbiology in Malaysian Journal of Microbiology
- Vol. 14 (5) , 424-434
Dehalogenase producing bacteria from extreme environment: A review
- 1 September 2018
- Published by Malaysian Journal of Microbiology in Malaysian Journal of Microbiology
- Vol. 14 (5) , 424-434
Open AccessDehalogenase producing bacteria from extreme environment: A review
- Open Access
- 1 June 2018
- Published by Malaysian Journal of Microbiology in Malaysian Journal of Microbiology
Purification and characterization of dehalogenase from Bacillus cereus SN1 isolated from cow dung
- 1 June 2018
- Published by Malaysian Journal of Microbiology in Malaysian Journal of Microbiology
Open AccessPurification and characterization of dehalogenase from Bacillus cereus SN1 isolated from cow dung
- Open Access
The Influence of Ultrasonic Vibration Frequency on the Properties of TiN Coated Biomedical Ti–13Zr–13Nb
Bare biomedical grade titanium alloys are prone to degradation when in a body fluid environment. Surface coatings such as Physical Vapor Deposition (PVD) can serve as one of the options to minimize this issue. Past reports showed that the PVD coated layer consists of pores, pinholes, and columnar growths which act as channels through which the aggressive medium attacks the substrate. Duplex and multilayer coatings seem able to address this issue to varying extents but at the expense of manufacturing time and cost. In this paper, the effect of an ultrasonic vibration frequency on PVD TiN coated Ti–13Zr–13Nb biomedical alloy was studied. Disk type samples were prepared and coated with TiN at fixed conditions: bias voltage (−125 V), substrate temperature (300 °C), and nitrogen gas flow rate (300 standard cubic centimeters per minute (SCCM)). An ultrasonic vibration was then subsequently applied to the TiN coated samples at frequencies of 8 kHz and 16 kHz for 5 min. All TiN coated samples treated with ultrasonic vibrations exhibited a higher corrosion resistance than the untreated ones. Microstructure analysis under Field Emission Scanning Electron Microscopy (FESEM) confirmed that the coated sample at frequencies of 16 kHz produced the most compact coating. It is believed that the hammering effect of the ultrasonic vibration reduced the micro channels’ size in the coating and thus decelerated the corrosion’s attack.
Open AccessThe Influence of Ultrasonic Vibration Frequency on the Properties of TiN Coated Biomedical Ti–13Zr–13Nb
Bare biomedical grade titanium alloys are prone to degradation when in a body fluid environment. Surface coatings such as Physical Vapor Deposition (PVD) can serve as one of the options to minimize this issue. Past reports showed that the PVD coated layer consists of pores, pinholes, and columnar growths which act as channels through which the aggressive medium attacks the substrate. Duplex and multilayer coatings seem able to address this issue to varying extents but at the expense of manufacturing time and cost. In this paper, the effect of an ultrasonic vibration frequency on PVD TiN coated Ti–13Zr–13Nb biomedical alloy was studied. Disk type samples were prepared and coated with TiN at fixed conditions: bias voltage (−125 V), substrate temperature (300 °C), and nitrogen gas flow rate (300 standard cubic centimeters per minute (SCCM)). An ultrasonic vibration was then subsequently applied to the TiN coated samples at frequencies of 8 kHz and 16 kHz for 5 min. All TiN coated samples treated with ultrasonic vibrations exhibited a higher corrosion resistance than the untreated ones. Microstructure analysis under Field Emission Scanning Electron Microscopy (FESEM) confirmed that the coated sample at frequencies of 16 kHz produced the most compact coating. It is believed that the hammering effect of the ultrasonic vibration reduced the micro channels’ size in the coating and thus decelerated the corrosion’s attack.
- 9 January 2018
- Published by Penerbit UTM Press in Jurnal Teknologi (Sciences & Engineering)
- Vol. 80 (2)
STUDY ON ADHESION STRENGTH OF TIN COATED BIOMEDICAL TI-13ZR-13NB ALLOY
One of the crucial factors which determine the success of coated implantation and stability in the long run is the strength of adhesion between the coating and substrate. After implantation, a weakly adhered coating may delaminate and this might seriously restrict the implant’s effectiveness and longevity. Based on past studies, the quality of TiN coating is directly influenced by the process parameters. The objective of this research is to evaluate the effect of N2 gas flow rate on adhesion strength of biomedical grade Ti-13Zr-13Nb alloy. In this research, N2 gas flow rate of 100, 200 and 300 sccm were varied while the other parameters (substrate temperature and bias voltage) were fixed. The scratch testing method was used to examine the adhesion strength of the TiN coating. This research used the calibrated optical images to verify the total coating failures on the scratched coated samples. The results indicated that the micro droplet form on the TiN coating decreases as the flow rate of the N2 gas increases. In contrast, the TiN coating’s adhesion strength increases with the increase of N2 gas flow rate. It can be concluded that N2 gas flow rate was significant factor in improving the coating properties of TiN on Ti-13Zr-13Nb alloy.
- 9 January 2018
- Published by Penerbit UTM Press in Jurnal Teknologi (Sciences & Engineering)
- Vol. 80 (2)
STUDY ON ADHESION STRENGTH OF TIN COATED BIOMEDICAL TI-13ZR-13NB ALLOY
One of the crucial factors which determine the success of coated implantation and stability in the long run is the strength of adhesion between the coating and substrate. After implantation, a weakly adhered coating may delaminate and this might seriously restrict the implant’s effectiveness and longevity. Based on past studies, the quality of TiN coating is directly influenced by the process parameters. The objective of this research is to evaluate the effect of N2 gas flow rate on adhesion strength of biomedical grade Ti-13Zr-13Nb alloy. In this research, N2 gas flow rate of 100, 200 and 300 sccm were varied while the other parameters (substrate temperature and bias voltage) were fixed. The scratch testing method was used to examine the adhesion strength of the TiN coating. This research used the calibrated optical images to verify the total coating failures on the scratched coated samples. The results indicated that the micro droplet form on the TiN coating decreases as the flow rate of the N2 gas increases. In contrast, the TiN coating’s adhesion strength increases with the increase of N2 gas flow rate. It can be concluded that N2 gas flow rate was significant factor in improving the coating properties of TiN on Ti-13Zr-13Nb alloy.
- Open Access
- 1 September 2017
- Published by Malaysian Journal of Microbiology in Malaysian Journal of Microbiology
Microbial isolation and degradation of selected haloalkanoic aliphatic acids by locally isolated bacteria: A review
- 1 September 2017
- Published by Malaysian Journal of Microbiology in Malaysian Journal of Microbiology
Open AccessMicrobial isolation and degradation of selected haloalkanoic aliphatic acids by locally isolated bacteria: A review
- 30 May 2016
- Published by Penerbit UTM Press in Jurnal Teknologi (Sciences & Engineering)
- Vol. 78 (5-10)
STUDY ON MICRO DROPLET REDUCTION ON TIN COATED BIOMEDICAL TI-13ZR-13NB ALLOY
Cathodic arc physical vapor deposition (CAPVD) is one of the physical Vapor deposition (PVD) techniques used to coat titanium nitride (TiN) on biomedical implants due to its good adhesion and high evaporation rate. However, this technique emits micro droplets which have can detrimental effect on the coating performance. Previous studies reported that micro droplets can be controlled through proper deposition parameters. In this paper, the PVD coating was performed on the Ti-13Zr-13Nb biomedical alloy with different substrate temperatures. Scanning electron microscopy (SEM) was used to characterized the surface morphology and coating thickness while X-Ray Diffraction (XRD was employed to evaluate the crystal phase of the coated substrates. Image analysis software was used to quantify micro droplets counts. The results show that higher substrate temperature able to decrease a significant amount of micro droplets and concurrently increase the thickness of TiN coating. A mixed crystal planes of (111) and (200) are obtained on the coated substrates at this setting which exhibits denser structure as compared to substrates coated at lower substrate temperature.
- 30 May 2016
- Published by Penerbit UTM Press in Jurnal Teknologi (Sciences & Engineering)
- Vol. 78 (5-10)
STUDY ON MICRO DROPLET REDUCTION ON TIN COATED BIOMEDICAL TI-13ZR-13NB ALLOY
Cathodic arc physical vapor deposition (CAPVD) is one of the physical Vapor deposition (PVD) techniques used to coat titanium nitride (TiN) on biomedical implants due to its good adhesion and high evaporation rate. However, this technique emits micro droplets which have can detrimental effect on the coating performance. Previous studies reported that micro droplets can be controlled through proper deposition parameters. In this paper, the PVD coating was performed on the Ti-13Zr-13Nb biomedical alloy with different substrate temperatures. Scanning electron microscopy (SEM) was used to characterized the surface morphology and coating thickness while X-Ray Diffraction (XRD was employed to evaluate the crystal phase of the coated substrates. Image analysis software was used to quantify micro droplets counts. The results show that higher substrate temperature able to decrease a significant amount of micro droplets and concurrently increase the thickness of TiN coating. A mixed crystal planes of (111) and (200) are obtained on the coated substrates at this setting which exhibits denser structure as compared to substrates coated at lower substrate temperature.
- 15 June 2008
- Published by Science Alert in Biotechnology
- Vol. 7 (3) , 481-486
Biodegradation of Monochloroacetic Acid by a Presumptive Pseudomonas sp. Strain R1 Bacterium Isolated from Malaysian Paddy (Rice) Field
A bacterial strain tentatively identified as Pseudomonas sp. R1 was isolated from a paddy (rice) field that could degrade monochloroacetic acid (MCA) for concentrations ranging from 5 to 40 mM. Quantitative agreement between the amount of MCA introduced and chloride released was also found. MCA dehalogenase activity in this strain was found to be inducible. Cell-free extracts displayed dehalogenating activity with specific halogenated organic compound with no activity on dichloropropionic acid or monochloropropionic acid. The estimated Km values for MCA was 0.14 mM. The optimal pH range for MCA dehalogenase activity (between pH 6.5 and 8.0), whereas the thermal stability profile stable up to 50 °C. The results of our current study demonstrated the potential use of Pseudomonas sp. R1 as suitable biological agent for biodegradation of MCA in contaminated agricultural area.This study was funded by a Ministry of Science, Technology and Innovation of Malaysia under Vot numbers 79073 (MOSTI e-Science Fund) and 74190 (RMC-IRPA RM-8 Research Grant) and both sources of funding are gratefully acknowledged by SNI, AMT and NHJ
- 15 June 2008
- Published by Science Alert in Biotechnology
- Vol. 7 (3) , 481-486
Biodegradation of Monochloroacetic Acid by a Presumptive Pseudomonas sp. Strain R1 Bacterium Isolated from Malaysian Paddy (Rice) Field
A bacterial strain tentatively identified as Pseudomonas sp. R1 was isolated from a paddy (rice) field that could degrade monochloroacetic acid (MCA) for concentrations ranging from 5 to 40 mM. Quantitative agreement between the amount of MCA introduced and chloride released was also found. MCA dehalogenase activity in this strain was found to be inducible. Cell-free extracts displayed dehalogenating activity with specific halogenated organic compound with no activity on dichloropropionic acid or monochloropropionic acid. The estimated Km values for MCA was 0.14 mM. The optimal pH range for MCA dehalogenase activity (between pH 6.5 and 8.0), whereas the thermal stability profile stable up to 50 °C. The results of our current study demonstrated the potential use of Pseudomonas sp. R1 as suitable biological agent for biodegradation of MCA in contaminated agricultural area.This study was funded by a Ministry of Science, Technology and Innovation of Malaysia under Vot numbers 79073 (MOSTI e-Science Fund) and 74190 (RMC-IRPA RM-8 Research Grant) and both sources of funding are gratefully acknowledged by SNI, AMT and NHJ