BBByambasuren Battulga

Byambasuren Battulga

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Byambasuren Battulga has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Vibration-Based Detection and Classification of Mechanical Defects in Induction Motor-Driven Systems During the Starting Transient

    by Byambasuren Battulga, Muhamad Faizan Shaikh, Taner Goktas, Muslum Arkan, Sang Bin Lee

    Vibration analysis is considered the most common and effective means of detecting mechanical faults such as imbalance, misalignment, and looseness in induction motor driven systems. Most mechanical problems result in an increase in vibration at multiples of the rotor speed frequency (1x) making it difficult to discern the source of vibration. In case of a fault alarm, the maintenance engineer usually performs a walk-around test to identify the source of vibration for planning maintenance, and therefore, is exposed to safety risks. In this paper, a new remote and automated test method for identifying the source of mechanical vibration during the starting transient of induction motors is proposed. The level and speed-dependency of vibration during rotor acceleration are used for identifying imbalance from other mechanical defects that produce 1x vibration. Test results on a 380 V, 5.5 kW induction motor under mechanical defects are given for verification. It is shown that the proposed method can provide automated identification of the source of vibration enabling maintenance to be performed in a safe, low cost, and efficient manner. The data acquired and analyzed for the testing are described and shared through this paper.


  • Remote and Automated Insulation Testing for VFD-Driven Motor Systems With High Resistance Grounding

    by Muhammad Faizan Shaikh, Byambasuren Battulga, Carlos A. Platero, Sang Bin Lee

    The failure rate of motor insulation in variable frequency drive (VFD) motors is higher compared to that of mains-fed motors due to the increased electrical stresses inflicted by the VFD. At present, motor insulation testing in industry relies on offline testing at the motor terminals, which requires physical access to the de-energized motor. Considering the increased likelihood of failure and difficulty of off-line testing, remote and automated testing is desirable, as VFD motors become prevalent. A new concept for testing the ground insulation of VFD motors that leverages high-resistance ground systems is presented in this article. The main concept is to apply the insulation test voltage using the VFD and measure the leakage current from the grounding resistor with high resolution. The capacitance (C) and dissipation factor (DF) are calculated and trended over time to identify ground insulation degradation before failure occurs. This test can be embedded in the VFD and performed automatically without motor access or disassembly whenever the motor is stopped. Test methods for assessing the insulation condition of the ac grid-, dc bus-, and motor-side of the VFD system are proposed and verified experimentally.


  • Sensitive Detection of Shorted Field Winding Turns in Salient Pole Synchronous Machines With High Frequency Pole Drop Test

    by Muhammad Faizan Shaikh, Byambasuren Battulga, Anyuan Chen, Arne Nysveen, Hossein Ehya, Kyeongyeol Kim, Baekkyeong Ko, Sang Bin Lee

    The pole drop test is the most widely accepted test for detecting short circuits in the field winding of salient pole synchronous machines (SPSM). Although it is a simple and effective test, there are concerns on the reliability due to the inherent asymmetry between the poles, especially for cases where the percentage of shorted turns is low. Considering that this is the primary test used in industry for detecting shorted field turns in SPSMs, improving the sensitivity of the test is highly desirable for reliable fault detection. In this paper, it is shown that the sensitivity of the pole drop test can be significantly improved by increasing the excitation frequency of the test voltage above the 50/60 Hz currently used, which is not reported elsewhere. An electrical equivalent circuit analysis and an experimental study on a 4 pole, 30 kVA synchronous motor and a 14 pole, 100 kVA hydrogenator prototype are given to verify the claims made.


  • Frequency Response Analysis for Quality Assurance Testing of Hairpin Stator Winding Insulation for Electric Vehicle Applications

    by J. Kim, S. Shin, B. Battulga, M. F. Shaikh, Y. Park, C. Lim, S. B. Lee

    With the rapid growth in electric vehicles (EV), hairpin wound stators are replacing random wound stators due to their higher power density and efficiency, and because of the ease with which manufacturing can be automated at a fast rate. Failure in the EV motor stator insulation is a major concern with increasing electrical stresses due to higher dc link voltage and wide bandgap devices. It is critical to implement a series of fast and effective quality assurance (QA) tests to screen defective units to maintain the quality and reliability, while keeping the production cost of EV motors low. Experience with EV motors showed that poor stator insulation quality is a leading cause of manufacturing defects in hairpin windings. In this work, the feasibility of applying frequency response analysis (FRA) for identifying defective hairpin stator insulation is evaluated. Test results on poorly impregnated EV motors with FRA and 6 common insulation tests show that FRA provides the most effective and reliable assessment of the insulation quality of hairpin wound stators.


  • Converter Embedded Testing of Inter-Laminar Core Insulation of Step-Up Transformers for Wind Energy Applications

    by Byambasuren Battulga, Muhammad Faizan Shaikh, Mohamed Osama, Sang Bin Lee

    Transformers used in wind power applications for stepping up the low voltage output of wind generators are known to have high failure rate due to the harsh operating conditions and environment. It is a challenge to perform on-site tests regularly because wind turbines are difficult to access due to their remote location. This makes remote and automated condition assessment of wind turbine transformers (WTT) crucial for preventing failure. In this paper, the feasibility of a new off-line method for testing the quality of the inter-laminar insulation of the step-up transformer core using the back-to-back converter is evaluated. The idea is to use the converter available in the wind turbine as the test equipment for injecting test signals into the WTT for remote and automated testing, whenever the wind turbine is disconnected from the grid. It is shown that inter-laminar core faults can be clearly detected with sensitivity comparable to the core loss test and commercial FRA equipment. An experimental study was performed on a 380/690 V transformer under emulated inter-laminar insulation fault conditions to verify the new test concept. It is shown that the proposed method can provide remote, automated testing of WTTs for reliable detection of core faults.


  • MEMS Accelerometer and Hall Sensor-Based Identification of Electrical and Mechanical Defects in Induction Motors and Driven Systems

    by Byambasuren Battulga, Muhammad Faizan Shaikh, Jae Wook Chun, Sung Bong Park, Sangwook Shim, Sang Bin Lee

    Early detection of faults in motor driven systems in industrial facilities is critical for maintaining productive, efficient, and safe operation of the plant. The recent trend in condition monitoring of industrial motors is shifting towards installation of compact, low-cost sensors on the motor from which the data is transferred wirelessly to a server for diagnosis. In this work, a cost-effective system and fault identification method based on MEMS capacitive accelerometer and a Hall-effect sensor measurements is presented. A new method for detection and classification of electrical and mechanical defects in the motor, coupling, and load based on spectral analysis of velocity and leakage flux measurements from the motor frame, is proposed. A comparative experimental evaluation of MEMS sensors and conventional piezoelectric accelerometers and search coils is given under rotor cage fault, eccentricity, imbalance, misalignment, bearing defect, and looseness conditions, to show the viability of the proposed fault detection method. It is shown that the proposed system can provide reliable detection and classification of the above-mentioned defects for variable frequency drive (VFD)-fed induction motors. The voltage, current, leakage/ airgap flux, and vibration database acquired from MEMS and conventional sensors under different operating conditions with 6 electrical and mechanical faults are described and shared through this paper.