MMMina Mohaghegh

Mina Mohaghegh

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mina Mohaghegh has a total of 39 co-authors. Here are the top co-authors by number of shared publications:

  • Anahita Safari

    Dept. of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran

    2 shared publications
  • Maryam Paknahad

    Oral and Dental Research Center, Oral and Maxillofacial Radiology Department, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran

    2 shared publications
  • Rashin Giti

    Dept. of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran

    2 shared publications
  • Seyed Ahmad Ghoraishian

    Department of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran

    2 shared publications
  • Seyed Ahmad Ghoraishian

    Dept. of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran

    2 shared publications
  • Amir Ali Reza Khaledi

    Dept. of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran

    1 shared publication

Latest Publications

  • Open Access

    Evaluation of the Effect of Distance Between Dental Abutments on the Accuracy of One‐Step and Two‐Step Impression Techniques With Polyvinyl Siloxane (PVS) Material

    by Seyyed Ahmad Ghoraishian, Mohsen Khataminia, Zahra Shahramian, Maryam Zare, Mina Mohaghegh

    Objective: The aim of this study was to evaluate the effect of distance between dental abutments on the accuracy of one‐step and two‐step impression techniques with polyvinyl siloxane (PVS) material.Materials and Methods: Four master models were fabricated with different interabutment distances equal to one, two, three, and four premolar lengths 1–4 (L1, L2, L3, and L4). Seven one‐step impressions were taken from each master model using PVS impression material (Group A, n = 7). For two‐step impressions, a 1.5 mm polyethylene spacer was used over each master model, and impressions were taken (Group B, n = 7). Scans from the casts were superimposed over the master model scans. Accordingly, differences were measured and compared with statistical tests (Kolmogorov–Smirnoff test, Mann–Whitney test, and Friedman's test) to evaluate the effect of interabutment distance within each impression technique group and also compare the one‐step and two‐step impression techniques. p value < 0.05 was considered statistically significant.Results: A statistically significant difference was noted among the different edentulous areas in the one‐step impression technique group (Group A, p = 0.010). At edentulous span, a statistically significant difference was recorded (p = 0.047) with two‐step impression technique being more accurate compared to the one‐step impression technique. Friedman's pairwise analysis in Group A demonstrated a significance between one premolar and four premolar interabutment distance groups (p = 0.006).Conclusion: The accuracy of the one‐step impression is significantly affected by the increase in interabutment distance from one premolar to four premolar edentulous.

  • Evaluation of the Relationship Between Osteoarthritis and Morphological Changes in the Joint Structures in Temporomandibular Disorders By Cone Beam Computed Tomography

    by Maryam Paknahad, Fatemeh Mazarei, Mina Mohaghegh

    Background Osteoarthritis is a degenerative joint disease that progresses slowly and is characterized by the destruction of the mandibular condyle and glenoid cavity. Degenerative changes in hard tissue affect TMJ bone structures and may lead to various morphological and functional changes Objectives The aim of this study was to investigate the relationship between osteoarthritis and morphological changes in temporomandibular joint components using CBCT. Methods In this cross-sectional study, 120 patients (60 patients with clinical symptoms of TMD and 60 patients without clinical symptoms of TMD) were selected and examined. Bone degenerative changes (Osteophyte, Flattening, Sclerosis, Erosion, and Pseudocyst) and morphological characteristics of condyle and articular eminence for TMD patients and control group were determined using CBCT images The severity of degenerative bone changes was categorized into four groups; G0 (no degenerative changes), G1 (one degenerative change—mild), G2 (two degenerative changes—moderate), and G3 (three or more degenerative changes—severe). The relationship between the severity of degenerative bone changes and morphological changes in temporomandibular joint was assessed using the One-Way ANOVA test. Results Most patients had mild degenerative changes (35.8%). The most important changes observed in patients were flattening and erosions. Moderate and severe changes in patients were significantly more than in the control group (P < 0.001). The mean of A-P Dimension and Glenoid Depth in patients was significantly lower than in the control group. A-P Dimension, Glenoid Depth substantially decrease in patients with severe changes. The highest frequency of Condylar Ratio in the posterior position was significantly related to patients with severe bone changes. Conclusion Due to the result of the current study, the following Conclusion can be driven: (1) More severe degenerative changes in the TMD patients were higher than the control group. (2) More severe degenerative changes had effect on the morphology of joint components.


  • Effect of denture cleansers on color stability and surface properties of denture base material containing titanium dioxide nanoparticles

    by Elham Ansarifard, Mina Mohaghegh, Mohammad Hossein Saadat, Masumeh Taghva

    Purpose: To investigate the effect of different denture cleansers on color stability, surface roughness, and hardness of polymethylmethacrylate (PMMA) infused with titanium dioxide nanoparticles (TiO2 NPs) at concentrations of 1% and 2% by weight on each.Materials and Methods: In this in vitro study, 90 disc‐shaped specimens (10×10×2 mm) were divided into 3 main groups: the non‐containing nanoparticle group (0wt% concentration), 1wt% concentration, and 2wt% concentration TiO2 NPs groups. Each group was further assorted into 3 subgroups (n = 10): immersed in distilled water, oxygenating tablet (Corega), and 0.5% sodium hypochlorite. Color change, surface roughness, and hardness values were assessed after 90 and 180 days of storage. Color changes (∆E) were measured with a spectrophotometer (VITA, Easy Shade V, Germany) and assessed using the CIE L*a*b* colorimetric system and the American National Bureau of Standards (NBS = 0.92×∆E). The surface roughness and surface hardness values were measured using a profilometer device and Vickers hardness tester, respectively. First, ANOVA‐repeated measurements were performed, followed by the Tukey test. The significance level in this study was considered 0.05.Results: At all concentrations, there were significant differences in the mean color changes of samples immersed in cleansers compared to distilled water (p < 0.01). Moreover, hypochlorite caused a significant increase compared to Corega at 0wt% concentration after 90 days and at 1wt% concentration after 90 and 180 days. Evaluations also showed that the mean NBS values in all cleanser groups were in the range of appreciable change, except the water group. In addition, only hypochlorite changed the color higher than the clinically acceptable range (∆E >3.7). The mean roughness of samples immersed in hypochlorite at 0wt% concentration was significantly higher than the samples containing TiO2 NPs (p = 0.006). No significant difference was observed in surface roughness of samples containing different concentrations of TiO2 NPs immersed in different cleansers; however, hypochlorite increased the surface roughness of samples without TiO2 NPs compared to samples containing TiO2 NPs after 180 days. The immersion time in cleansers had a significant influence on the surface roughness and hardness while having no effect on the color.Conclusion: In general, the cleansers had a significant effect on color change in all groups compared to distilled water. The adverse effect of hypochlorite was more than Corega. The cleansers in the samples containing TiO2 NPs did not make a significant difference in surface roughness in comparison with the distilled water groups. Surface hardness of the samples was not affected in a steady pattern by the cleansers.


  • Open Access

    Effect of denture cleansers on color stability and surface roughness of denture bases fabricated from three different techniques: Conventional heat‐polymerizing, CAD/CAM additive, and CAD/CAM subtractive manufacturing

    by Mehrab Takhtdar, Nahid Azizimoghadam, Mohammad Hasan Kalantari, Mina Mohaghegh

    Purpose: Denture base materials are commonly exposed to different denture cleansers which can affect their essential properties. This study aimed to assess the effect of denture cleansers on color stability and surface roughness of poly methyl methacrylate (PMMA) denture bases fabricated from different techniques: Conventional heat‐polymerizing, CAD/CAM additive and CAD/CAM subtractive.Materials and Methods: In this in vitro study, 24 disc‐shaped specimens were fabricated by the mentioned methods for each group. The initial color and surface roughness of specimens were recorded. The specimens were randomly divided into three subgroups (n = 8): a control subgroup (distilled water), and two experimental subgroups of bioactive oxygen tablet (Corega) and 1% sodium hypochlorite solution. Then they were immersed in the solutions simulating 180 days of clinical use. Color change (∆E) was measured by a spectrophotometer according to the CIE L*a*b* color space and the American National Bureau of Standards (NBS = 0.92 × ∆E). Final surface roughness was recorded by a profilometer and its change was calculated. The Kruskal–Wallis test followed by the Wilcoxon signed rank test were used for statistical analyses (α = .05).Results: The conventional and CAD/CAM subtractive groups showed an increase in surface roughness following immersion in hypochlorite solution (p < .05). After immersion in the solutions, the highest surface roughness was noted in the conventional group, and the lowest in the CAD/CAM additive group. The CAD/CAM additive group experienced a significant color change in hypochlorite solution (p < .05) and showed the highest color change while the CAD/CAM subtractive group showed the lowest color change in all denture cleanser solutions.Conclusion: Although the CAD/CAM additive denture base resins had the lowest surface roughness after exposure to denture cleanser solutions, they showed significant color change, which should be taken into account. Using hypochlorite as a denture cleanser should be cautioned due to its negative effects on the surface roughness and color stability of denture base materials.


  • Open Access

    Effect of inter-dental abutment distance on the impression accuracy of digital and conventional methods

    by Mina Mohaghegh, Shouka Shalileh, Kamyar Abbasi, Hamed Azhmand, Seyed Ahmad Ghoraishian

    This study aimed to examine the effect of inter-dental abutment distance on the accuracy of digital and conventional impression methods. Five maxillary


  • Open Access

    The Effect of Finish Line Design on the Fracture Strength of Zirconia Copings.

    by Zahra Hashemi Ardakani, Sahar Khorsandipour, Mina Mohghegh, Seyed Ahmad Ghoreishian, Amir Ali Reza Khaledi

    One of the major concerns about all ceramic crowns is their fracture resistance. The purpose of this in vitro study was to evaluate the effect of two marginal designs (shoulder 90°, shoulder 135°) on the fracture resistance of zirconia copings. In this in vitro study, 20 brass dies were prepared using milling machine: 10 with 1mm width shoulder 90° marginal design and the other 10 with 1mm width shoulder 135° finish line design. Zirconia cores with 0.5mm thickness and 30μm cement space were fabricated on brass dies. The copings were cemented on the dies and fracture test was done using a universal testing machine. Data were analyzed using Mann-Whitney test. The mean value of fracture resistance for shoulder 90° finish line design were 368.3±109.4 N and for shoulder 135° finish line design were 518.4±115.5 N. Data analysis revealed a statistically significant difference between groups (p< 0.05). The results of this study showed that the finish line design of zirconia copings influences their fracture resistance. A 135° shoulder finish line design can improve the fracture resistance of zirconia crowns.


  • Open Access

    The influence of different shades and brands of resin-based luting agents on the final color of leucite-reinforced veneering ceramic

    by Rashin Giti, Amirhossein Barfei, Mina Mohaghegh

    This study aimed to evaluate the influence of different shades and brands of resin-based luting agents on the final color of a leucite-reinforced veneering ceramic. This in-vitro study was done on 36 ceramic discs (IPS Empress I, 11 × 0.5 mm, A2 shade) and 36 cement disks (11 × 0.2 mm) made of Panavia SA Cement Plus (Kuraray Medical Inc.) and Choice2 (Bisco Inc., Schumburg) brands in translucent, universal A2, and opaque shades (n = 6 per each color in each resin cement brand). Color parameters (CIEL*a*b*) of ceramic specimens were calculated without and with each brand/shade of resin-based luting agents by using a spectrophotometer, and put into CIELab formula. The color differences (ΔE) between the two sets of measurements were calculated and analyzed with two-way ANOVA and Tukey's post hoc test (α = 0.05). Both the resin-based luting agent shade (P < 0.001) and brand (P = 0.023) significantly affected the color differences. ΔE values were significantly different between Panavia-opaque and Choice2-opaque (P < 0.001). No significant difference existed between ΔE of the two brands in A2 (P = 0.178) and translucent shades (P = 0.079). The ΔE values of Panavia-A2 was significantly different from the translucent and opaque shades of the same brand. Moreover, the ΔE of Choice2-translucent shade was significantly lower than that of A2 and opaque shades. The ΔE values were higher than the clinically-acceptable threshold in all groups (ΔE > 3.7) except for Choice2-translucent (ΔE = 3.37). The final color of leucite-reinforced veneering ceramic can be affected by the same shades of resin-based luting agents from different brands and different shades of resin-based luting agents from the same brand.


  • Open Access

    Evaluation of accuracy of shade selection using two spectrophotometer systems: Vita Easyshade and Degudent Shadepilot

    by Mohammad Hassan Kalantari, Seyed Ahmad Ghoraishian, Mina Mohaghegh

    Objective: The aim of this in vitro study was to evaluate the accuracy of shade matching using two spectrophotometric devices. Materials and Methods: Thirteen patients who require a full coverage restoration for one of their maxillary central incisors were selected while the adjacent central incisor was intact. 3 same frameworks were constructed for each tooth using computer-aided design and computer-aided manufacturing technology. Shade matching was performed using Vita Easyshade spectrophotometer, Shadepilot spectrophotometer, and Vitapan classical shade guide for the first, second, and third crown subsequently. After application, firing, and glazing of the porcelain, the color was evaluated and scored by five inspectors. Results: Both spectrophotometric systems showed significantly better results than visual method (P < 0.05) while there were no significant differences between Vita Easyshade and Shadepilot spectrophotometers (P < 0.05). Conclusion: Spectrophotometers are a good substitute for visual color selection methods.


    • 1 June 2015
      • Vol. 16  (2) , 113-120
    Open Access

    The Effect of Porcelain Firing and Type of Finish Line on the Marginal Fit of Zirconia Copings

    by Mahroo Vojdani, Anahita Safari, Mina Mohaghegh, Soheil Pardis, Farideh Mahdavi

    Although all-ceramic restorations are broadly used, there is a lack of information concerning how their fit is affected by fabrication procedure and marginal configuration. The purpose of this study was to evaluate the marginal fit of zirconia CAD/CAM ceramic crowns before and after porcelain firing. The influence of finish line configuration on the marginal fit was also evaluated. Twenty standardized zirconia CAD/CAM copings were fabricated for chamfer and shoulder finish line designs (n=10). The marginal fit of specimens was measured on 18 points, marked on the master metal die by using a digital microscope. After the crowns were finalized by porcelain veneering, the measurements of marginal fit were performed again. The means and standard deviations were calculated and data were analyzed using student’s t-test and paired t-test (α=0.05). There were significant differences between marginal fit of chamfer and shoulder finish line groups before and after porcelain firing (p= 0.014 and p= 0.000, respectively). The marginal gap of copings with shoulder finish line was significantly smaller than those with chamfer configuration (p= 0.000), but there were no significant differences between the two marginal designs, after porcelain firing (p= 0.341). Porcelain veneering was found to have a statistically significant influence on the marginal fit of zirconia CAD/CAM crowns. Both margin configurations showed marginal gaps that were within a reported clinically acceptable range of marginal discrepancy.