Mustafa Yusuf Yazici
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Mustafa Yusuf Yazici has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Orhan Aydin
Karadeniz Technical University
8 shared publications - Mete Avci
Department of Mechanical Engineering, Karadeniz Technical University, Trabzon, Turkey
5 shared publications - Ahmet Aktürk
Faculty of Engineering, Department of Mechanical Engineering, Iğdır University, 76000 Iğdır, Türkiye
4 shared publications - Bugra Sarper
Tarsus Üniversitesi
4 shared publications - Sare Mitincik
SAMSUN ÜNİVERSİTESİ, MÜHENDİSLİK FAKÜLTESİ, MAKİNE MÜHENDİSLİĞİ BÖLÜMÜ
4 shared publications - Mehmet Saglam
Tarsus Üniversitesi
3 shared publications
Latest Publications
- 2 October 2026
- Published by Springer Nature in Emergent Materials
- Vol. 9 (10) , 251
Role of various storage gaps in the discharge exergy performance of annular thermal energy storage units
- 2 October 2026
- Published by Springer Nature in Emergent Materials
- Vol. 9 (10) , 251
Role of various storage gaps in the discharge exergy performance of annular thermal energy storage units
- 11 July 2026
- Published by Elsevier in International Journal of Thermal Sciences
- Vol. 230
The role of cooling plate–battery contact angle in liquid-cooled cylindrical battery packs
- 11 July 2026
- Published by Elsevier in International Journal of Thermal Sciences
- Vol. 230
The role of cooling plate–battery contact angle in liquid-cooled cylindrical battery packs
- 29 June 2026
- Published by Ordu University in Ordu Üniversitesi Bilim ve Teknoloji Dergisi
- Vol. 16
Discharging Characteristics of Graphite Matrix–PCM Composites in a Tube-in-Shell TES System under Different Operating Conditions
The inherently low thermal conductivity of phase change materials (PCMs) significantly limits their applicability in thermal energy storage (TES) systems. To address this limitation, carbon-based porous matrices are widely utilized to establish highly conductive thermal networks, enhancing overall thermal conductivity, accelerating heat recovery, and improving energy efficiency. In this study, a numerical investigation validated by a small-scale experimental setup is conducted to evaluate the heat recovery performance of a paraffin/graphite matrix composite in an annular geometry with various configurations and operating conditions. Graphite matrices with bulk densities of 23 kg/m³, 50 kg/m³, and 100 kg/m³ are used to encapsulate the paraffin a a storage material. Two-dimensional (2D) and three-dimensional (3D) models were developed, and the effects of varying wall temperatures and inlet parameters (temperature and velocity) on the discharging process were comparatively analyzed. Simulations are performed at three temperature levels (20 °C, 30 °C, and 40 °C), representing practical applications such as tap water, thermal power plant cooling water, and low-temperature geothermal systems. The results indicate that increasing wall or inlet temperatures prolongs the solidification process by reducing the thermal gradient between the PCM and the heat transfer fluid. In contrast, the mass flow boundary condition enhances heat recovery compared to the isothermal wall configuration, resulting in shorter discharge times.
- 29 June 2026
- Published by Ordu University in Ordu Üniversitesi Bilim ve Teknoloji Dergisi
- Vol. 16
Discharging Characteristics of Graphite Matrix–PCM Composites in a Tube-in-Shell TES System under Different Operating Conditions
The inherently low thermal conductivity of phase change materials (PCMs) significantly limits their applicability in thermal energy storage (TES) systems. To address this limitation, carbon-based porous matrices are widely utilized to establish highly conductive thermal networks, enhancing overall thermal conductivity, accelerating heat recovery, and improving energy efficiency. In this study, a numerical investigation validated by a small-scale experimental setup is conducted to evaluate the heat recovery performance of a paraffin/graphite matrix composite in an annular geometry with various configurations and operating conditions. Graphite matrices with bulk densities of 23 kg/m³, 50 kg/m³, and 100 kg/m³ are used to encapsulate the paraffin a a storage material. Two-dimensional (2D) and three-dimensional (3D) models were developed, and the effects of varying wall temperatures and inlet parameters (temperature and velocity) on the discharging process were comparatively analyzed. Simulations are performed at three temperature levels (20 °C, 30 °C, and 40 °C), representing practical applications such as tap water, thermal power plant cooling water, and low-temperature geothermal systems. The results indicate that increasing wall or inlet temperatures prolongs the solidification process by reducing the thermal gradient between the PCM and the heat transfer fluid. In contrast, the mass flow boundary condition enhances heat recovery compared to the isothermal wall configuration, resulting in shorter discharge times.
- Open Access
- 3 March 2026
- Published by Elsevier in SSRN Electronic Journal
Role of Various Storage Gaps in the Discharge Exergy Performance of Annular Thermal Energy Storage Units
Paraffin-impregnated graphite-based composites are widely used to mitigate the low thermal conductivity of paraffins in latent heat thermal energy storage (LHTES) systems; however, enhanced thermal conductivity does not necessarily ensure higher exergetic performance. In this study, an exergy-based assessment of paraffin-impregnated graphite composites is carried out to evaluate discharge-state energy recovery efficiency of LHTES system. A composite block densities of 50 kg/m3 are investigated while maintaining a constant composite mass. Numerical simulations are performed under four annular gap (20, 30, 40, and 50 mm), three inlet velocities (0.1 m/s, 0.2 m/s and 0.3 m/s), and two inlet temperatures (25 °C and 35 °C), supported by experimental validation using a custom-designed test rig and the enthalpy-porosity method. Results show that heat transfer within the porous graphite matrix is governed by conduction, enabling uniform discharge behavior and a homogeneous temperature distribution. The annular storage gap exhibited a stronger impact at 50 kg/m3 block density, emphasizing its dominant effect on discharging time and thermal recovery dynamics. The highest discharge exergy efficiency was achieved at an annular width of 50 mm, HTF inlet temperature of 35 °C, and an inlet velocity of 0.3 m/s.
- 3 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessRole of Various Storage Gaps in the Discharge Exergy Performance of Annular Thermal Energy Storage Units
Paraffin-impregnated graphite-based composites are widely used to mitigate the low thermal conductivity of paraffins in latent heat thermal energy storage (LHTES) systems; however, enhanced thermal conductivity does not necessarily ensure higher exergetic performance. In this study, an exergy-based assessment of paraffin-impregnated graphite composites is carried out to evaluate discharge-state energy recovery efficiency of LHTES system. A composite block densities of 50 kg/m3 are investigated while maintaining a constant composite mass. Numerical simulations are performed under four annular gap (20, 30, 40, and 50 mm), three inlet velocities (0.1 m/s, 0.2 m/s and 0.3 m/s), and two inlet temperatures (25 °C and 35 °C), supported by experimental validation using a custom-designed test rig and the enthalpy-porosity method. Results show that heat transfer within the porous graphite matrix is governed by conduction, enabling uniform discharge behavior and a homogeneous temperature distribution. The annular storage gap exhibited a stronger impact at 50 kg/m3 block density, emphasizing its dominant effect on discharging time and thermal recovery dynamics. The highest discharge exergy efficiency was achieved at an annular width of 50 mm, HTF inlet temperature of 35 °C, and an inlet velocity of 0.3 m/s.
- Open Access
- 2 March 2026
- Published by Elsevier in SSRN Electronic Journal
Experimental Evaluation of Thermal and Electrical Performance of Li-Ion Battery Modules Using Expanded Graphite/Paraffin Composites with Varying Bulk Densities
Electro-mobility with Li-ion technology has a great potential to reach the sustainable development goals (SDGs), including affordable and clean energy, sustainable cities and communities. Electro-mobility performance links directly with Li-ion battery performance, and the performance and safety levels of these batteries are primarily a function of operating temperature. Although PCM-graphite based approach offers a valuable solution to regulate the operating temperature, there are limited studies providing experimental data considering realistic operational conditions for battery modules. Therefore, comprehensive experimental investigation is carried out to ensure the thermal and electrical performances of battery module equipped with passive cooling approach of expanded graphite matrix/PCM. Battery modules with 6S4P cell configuration were used in this study. Experiments were carried out using RT-42 PCM for different matrix bulk densities (50 g/L, 75 g/L, and 100 g/L), different ambient temperatures (25°C and 35°C), and different discharge currents (13.4 A and 30 A). The performances of composite battery modules and bare battery module were compared and discussed. For 25 °C and 30 A test, the EG/PCM (100 g/L module showed improvements of 21.4% and 68.8% in maximum operating temperature and maximum temperature difference, respectively, compared to the bare module. In the demanding 35°C and 30 A test, the same composite battery module showed 91%, 91%, and 71% superior performance compared to the bare battery module in terms of operating time, capacity, and energy capacity, respectively. This passive cooling approach mitigates thermal hotspots, reduces safety risks, and offers a lightweight, efficient BTMS solution for EVs.
- 2 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessExperimental Evaluation of Thermal and Electrical Performance of Li-Ion Battery Modules Using Expanded Graphite/Paraffin Composites with Varying Bulk Densities
Electro-mobility with Li-ion technology has a great potential to reach the sustainable development goals (SDGs), including affordable and clean energy, sustainable cities and communities. Electro-mobility performance links directly with Li-ion battery performance, and the performance and safety levels of these batteries are primarily a function of operating temperature. Although PCM-graphite based approach offers a valuable solution to regulate the operating temperature, there are limited studies providing experimental data considering realistic operational conditions for battery modules. Therefore, comprehensive experimental investigation is carried out to ensure the thermal and electrical performances of battery module equipped with passive cooling approach of expanded graphite matrix/PCM. Battery modules with 6S4P cell configuration were used in this study. Experiments were carried out using RT-42 PCM for different matrix bulk densities (50 g/L, 75 g/L, and 100 g/L), different ambient temperatures (25°C and 35°C), and different discharge currents (13.4 A and 30 A). The performances of composite battery modules and bare battery module were compared and discussed. For 25 °C and 30 A test, the EG/PCM (100 g/L module showed improvements of 21.4% and 68.8% in maximum operating temperature and maximum temperature difference, respectively, compared to the bare module. In the demanding 35°C and 30 A test, the same composite battery module showed 91%, 91%, and 71% superior performance compared to the bare battery module in terms of operating time, capacity, and energy capacity, respectively. This passive cooling approach mitigates thermal hotspots, reduces safety risks, and offers a lightweight, efficient BTMS solution for EVs.
- 26 January 2026
- Published by Adiyaman University in Adıyaman Üniversitesi Mühendislik Bilimleri Dergisi
- Vol. 13 (1) , 1-10
Elektrikli Araç Batarya Paketlerinde Sıvı Soğutma: Akış Debisi ve Deşarj Oranının Deneysel Değerlendirilmesi
Elektrikli araçların (EV) verimliliği ve güvenliği için batarya termal yönetim sistemi (BTYS) kritik bir öneme sahiptir. Bu çalışmada, sıvı soğutmalı aktif BTYS ile soğutulan Li-iyon batarya paketinin ısıl ve hidrolik performansı deneysel olarak incelenmiştir. Genişletilmiş ısı transfer yüzey alanına sahip bir soğutucu plaka kullanılan sistemde, beş farklı akış debisi (0.1–1.0 L/dk) ve üç farklı deşarj oranında (0.5C–2.0C) deneysel testler gerçekleştirilmiştir. Maksimum sıcaklık, maksimum sıcaklık farkı ve basınç düşümü temel performans kriterleri olarak değerlendirilmiştir. Sonuçlar, 0.5 ve 1.0C deşarj oranlarında sıcaklıkların 26.38–32.56°C aralığında kalarak kabul edilebilir sınırlar içinde olduğunu, 2.0C deşarj oranında ise artan debinin maksimum sıcaklığı 10.8°C ve sıcaklık farkını 5.2°C düşürerek soğutma performansını belirgin biçimde iyileştirdiğini göstermiştir. Bununla birlikte, debi artışı basınç düşümünün de artmasına neden olmuştur. İncelenen performans kriterleri birlikte değerlendirildiğinde, ideal akış debisinin 0.5 L/dk olduğu belirlenmiştir. İdeal debi değerinin hem termal güvenlik hem de enerji verimliliği açısından dengeli bir BTYS tasarımı sunduğu sonucuna varılmıştır.
- 26 January 2026
- Published by Adiyaman University in Adıyaman Üniversitesi Mühendislik Bilimleri Dergisi
- Vol. 13 (1) , 1-10
Elektrikli Araç Batarya Paketlerinde Sıvı Soğutma: Akış Debisi ve Deşarj Oranının Deneysel Değerlendirilmesi
Elektrikli araçların (EV) verimliliği ve güvenliği için batarya termal yönetim sistemi (BTYS) kritik bir öneme sahiptir. Bu çalışmada, sıvı soğutmalı aktif BTYS ile soğutulan Li-iyon batarya paketinin ısıl ve hidrolik performansı deneysel olarak incelenmiştir. Genişletilmiş ısı transfer yüzey alanına sahip bir soğutucu plaka kullanılan sistemde, beş farklı akış debisi (0.1–1.0 L/dk) ve üç farklı deşarj oranında (0.5C–2.0C) deneysel testler gerçekleştirilmiştir. Maksimum sıcaklık, maksimum sıcaklık farkı ve basınç düşümü temel performans kriterleri olarak değerlendirilmiştir. Sonuçlar, 0.5 ve 1.0C deşarj oranlarında sıcaklıkların 26.38–32.56°C aralığında kalarak kabul edilebilir sınırlar içinde olduğunu, 2.0C deşarj oranında ise artan debinin maksimum sıcaklığı 10.8°C ve sıcaklık farkını 5.2°C düşürerek soğutma performansını belirgin biçimde iyileştirdiğini göstermiştir. Bununla birlikte, debi artışı basınç düşümünün de artmasına neden olmuştur. İncelenen performans kriterleri birlikte değerlendirildiğinde, ideal akış debisinin 0.5 L/dk olduğu belirlenmiştir. İdeal debi değerinin hem termal güvenlik hem de enerji verimliliği açısından dengeli bir BTYS tasarımı sunduğu sonucuna varılmıştır.
- Open Access
- 6 January 2026
- Published by Elsevier in Journal of Engineering Research
- Vol. 14 (2) , 2118-2132
Assessing influencing factors on a passive cooling system for a Li-ion battery cell by employing the RSM methodology
- 6 January 2026
- Published by Elsevier in Journal of Engineering Research
- Vol. 14 (2) , 2118-2132
Open AccessAssessing influencing factors on a passive cooling system for a Li-ion battery cell by employing the RSM methodology