Bhupendra Kumar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Bhupendra Kumar has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Anamika Yadav
National Institute of Technology
7 shared publications - Almoataz Youssef Abdelaziz
Electrical Power and Machines Engineering Department, Faculty of Engineering, Ain Shams University, Cairo, Egypt
3 shared publications - Avinash S. Welankiwar
G. H. Raisoni Institute of Engineering Technology,Dept. of Electrical Engineering,Nagpur,India,440016
1 shared publication M. A. Sobhy
Ain Shams University
1 shared publicationM. Ezzat
Ain Shams University
1 shared publicationMohammad Pazoki
School of EngineeringDamghan University Damghan Iran
1 shared publication
Latest Publications
- Open Access
- 2 March 2026
- Published by Elsevier in SSRN Electronic Journal
Phase dispersion index based fault detection and classification method in transmission lines connecting AC Microgrids
Conventional magnitude-based protection techniques are no longer dependable due to the substantial changes in fault current characteristics induced from inverter-interfaced distributed generation in AC microgrids. The Phase Dispersion Index based fault detection and classification technique for transmission lines connecting AC microgrids is presented in this study. The proposed approach uses phase dispersion characteristics of phase currents derived using sliding window technique and Hilbert Huang Transform based signal processing to quantify fault-induced asymmetry through a robust PDI. Self adaptive threshold is used to boost sensitivity of detection. Phase wise measured instantaneous currents from both line ends are only required for computation. While fault classification is carried out utilizing phase-wise persistence and zero sequence current to identify the presence of a ground flag, fault detection is accomplished by tracking the rapid deviation of the PDI with respect to the self-adaptive threshold. Case studies of short circuit faults with variations in DG penetration levels are simulated at line receiving end and 60 km far from receiving end using PSCAD, fault detection and classification is implemented in MATLAB. With a minimal time of detection of 0.6 milliseconds, the proposed technique accurately identifies every simulated fault, confirms speed, precision, and dependable fault detection and classification.
- 2 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessPhase dispersion index based fault detection and classification method in transmission lines connecting AC Microgrids
Conventional magnitude-based protection techniques are no longer dependable due to the substantial changes in fault current characteristics induced from inverter-interfaced distributed generation in AC microgrids. The Phase Dispersion Index based fault detection and classification technique for transmission lines connecting AC microgrids is presented in this study. The proposed approach uses phase dispersion characteristics of phase currents derived using sliding window technique and Hilbert Huang Transform based signal processing to quantify fault-induced asymmetry through a robust PDI. Self adaptive threshold is used to boost sensitivity of detection. Phase wise measured instantaneous currents from both line ends are only required for computation. While fault classification is carried out utilizing phase-wise persistence and zero sequence current to identify the presence of a ground flag, fault detection is accomplished by tracking the rapid deviation of the PDI with respect to the self-adaptive threshold. Case studies of short circuit faults with variations in DG penetration levels are simulated at line receiving end and 60 km far from receiving end using PSCAD, fault detection and classification is implemented in MATLAB. With a minimal time of detection of 0.6 milliseconds, the proposed technique accurately identifies every simulated fault, confirms speed, precision, and dependable fault detection and classification.
- 16 August 2021
- Published by Taylor & Francis
- p. 237-253
AI-Based Protective Relaying Schemes for Transmission Line Compensated with FACTS Devices
In the modern world, growing energy demand has been fulfilled by increasing power generating capacity and simultaneously building new transmission infrastructure or enhancing the power transferal capability of the prevailing transmission line. Flexible AC Transmission System (FACTS) technology has emerged owing to the progression in the power electronics and automated control systems. FACTS development from a thyristor-based device to a voltage source converter (VSC)–based device includes three important FACTS controllers: (1) series controller (TCSC), (2) shunt controller (SVC/STATCOM), and (3) combined series-shunt controller (UPFC). Deployment of FACTS controller into the transmission network would negatively influence the performance of the conventional methods, as well as the nonlinear and dynamic behavior of VSCs makes it a challenging task. In this regard, different artificial intelligence (AI)–based algorithms have been recommended in the literature in the last three decades for the protection of FACTS compensated transmission line. AI-based algorithms are suitable for the nonlinear and complex problem. A variety of machine learning and AI techniques have been presented for fault analysis in FACTS-compensated transmission lines. In this book chapter, a comprehensive review of different AI-based algorithms and feature extraction techniques is presented for the protection of the transmission line incorporating FACTS controller. This exhaustive review of literature in the field of FACTS-based transmission line will assist the researchers to begin their work and choose a suitable method for the respective power system network. Lastly, the contemporary status with a recommendation towards the forthcoming direction of research for FACTS compensated transmission line has also been proposed.
- 16 August 2021
- Published by Taylor & Francis
- p. 237-253
AI-Based Protective Relaying Schemes for Transmission Line Compensated with FACTS Devices
In the modern world, growing energy demand has been fulfilled by increasing power generating capacity and simultaneously building new transmission infrastructure or enhancing the power transferal capability of the prevailing transmission line. Flexible AC Transmission System (FACTS) technology has emerged owing to the progression in the power electronics and automated control systems. FACTS development from a thyristor-based device to a voltage source converter (VSC)–based device includes three important FACTS controllers: (1) series controller (TCSC), (2) shunt controller (SVC/STATCOM), and (3) combined series-shunt controller (UPFC). Deployment of FACTS controller into the transmission network would negatively influence the performance of the conventional methods, as well as the nonlinear and dynamic behavior of VSCs makes it a challenging task. In this regard, different artificial intelligence (AI)–based algorithms have been recommended in the literature in the last three decades for the protection of FACTS compensated transmission line. AI-based algorithms are suitable for the nonlinear and complex problem. A variety of machine learning and AI techniques have been presented for fault analysis in FACTS-compensated transmission lines. In this book chapter, a comprehensive review of different AI-based algorithms and feature extraction techniques is presented for the protection of the transmission line incorporating FACTS controller. This exhaustive review of literature in the field of FACTS-based transmission line will assist the researchers to begin their work and choose a suitable method for the respective power system network. Lastly, the contemporary status with a recommendation towards the forthcoming direction of research for FACTS compensated transmission line has also been proposed.
- 21 December 2018
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 29 (4) , e2804
Impedance differential plane for fault detection and faulty phase identification of FACTS compensated transmission line
- 21 December 2018
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 29 (4) , e2804
Impedance differential plane for fault detection and faulty phase identification of FACTS compensated transmission line
- 1 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 224-229
Impact of UPFC on alpha plane line current differential protection
This paper presents an impact on alpha plane characteristics of line current differential protection in presence of unified power flow controller (UPFC). UPFC is a versatile device with the ability to regulate bus voltage and control power flow of the transmission line independently and simultaneously; hence, it has an impact on the current signals received at the relay location. With the advancement in synchrophasor technology and wide area measurement system for transmission line protection, the differential protection scheme is a most suited scheme over the over-current, distance and directional protection. To investigate the impact of UPFC on alpha plane line current differential protection, detailed model of UPFC has been simulated in MATLAB and dynamic behaviour of the UPFC is considered. Moreover, an impact of different operation modes of UPFC and different compensation level on alpha plane characteristics are evaluated.
- 1 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 224-229
Impact of UPFC on alpha plane line current differential protection
This paper presents an impact on alpha plane characteristics of line current differential protection in presence of unified power flow controller (UPFC). UPFC is a versatile device with the ability to regulate bus voltage and control power flow of the transmission line independently and simultaneously; hence, it has an impact on the current signals received at the relay location. With the advancement in synchrophasor technology and wide area measurement system for transmission line protection, the differential protection scheme is a most suited scheme over the over-current, distance and directional protection. To investigate the impact of UPFC on alpha plane line current differential protection, detailed model of UPFC has been simulated in MATLAB and dynamic behaviour of the UPFC is considered. Moreover, an impact of different operation modes of UPFC and different compensation level on alpha plane characteristics are evaluated.
- Open Access
- 1 September 2017
- Published by Institution of Engineering and Technology (IET) in IET Science, Measurement & Technology
- Vol. 11 (6) , 703-712
Backup protection scheme for transmission line compensated with UPFC during high impedance faults and dynamic situations
This study presents a backup protection scheme for transmission line compensated with unified power flow controller (UPFC) using power differential protection algorithm. In this scheme, power differential feature is evaluated from the apparent power flow in each phase at the local and remote bus to discriminate between the fault and normal situation. The proposed protection algorithm can be integrated with the conventional distance protection to supervise its operation during stressed conditions. Extensive fault simulation studies have been performed for different types of fault with several conditions and critical dynamic situations/issues such as load encroachment, power swing and high impedance fault (HIF). A 500 kV three machines four bus transmission system with UPFC has been used to validate the performance of the proposed scheme using MATLAB software. The test results depict that the proposed scheme is robust against HIF, power swing and load encroachment. It is not affected by the variation in pre‐fault power flow angle and synchronisation delay. The proposed scheme has also been tested for current transformer (CT) and coupling capacitor voltage transformer (CCVT) transient error, which brings out the superiority of the scheme.
- 1 September 2017
- Published by Institution of Engineering and Technology (IET) in IET Science, Measurement & Technology
- Vol. 11 (6) , 703-712
Open AccessBackup protection scheme for transmission line compensated with UPFC during high impedance faults and dynamic situations
This study presents a backup protection scheme for transmission line compensated with unified power flow controller (UPFC) using power differential protection algorithm. In this scheme, power differential feature is evaluated from the apparent power flow in each phase at the local and remote bus to discriminate between the fault and normal situation. The proposed protection algorithm can be integrated with the conventional distance protection to supervise its operation during stressed conditions. Extensive fault simulation studies have been performed for different types of fault with several conditions and critical dynamic situations/issues such as load encroachment, power swing and high impedance fault (HIF). A 500 kV three machines four bus transmission system with UPFC has been used to validate the performance of the proposed scheme using MATLAB software. The test results depict that the proposed scheme is robust against HIF, power swing and load encroachment. It is not affected by the variation in pre‐fault power flow angle and synchronisation delay. The proposed scheme has also been tested for current transformer (CT) and coupling capacitor voltage transformer (CCVT) transient error, which brings out the superiority of the scheme.
- 13 July 2017
- Published by Springer Nature in Advances in Intelligent Systems and Computing
- p. 127-139
Artificial Bee Colony Optimization Algorithm for Fault Section Estimation
- 13 July 2017
- Published by Springer Nature in Advances in Intelligent Systems and Computing
- p. 127-139
Artificial Bee Colony Optimization Algorithm for Fault Section Estimation
- Open Access
- 28 June 2017
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 11 (13) , 3406-3416
Synchrophasors assisted protection scheme for the shunt‐compensated transmission line
This study presents synchrophasor assisted protection scheme for the protection of long transmission line compensated with shunt flexible AC transmission system (FACTS) device. With the advancement in synchrophasor technology, data communication medium, and wide area measurement system for transmission line protection, the differential protection scheme is a most suited scheme over the over‐current, distance and directional protection schemes. The proposed scheme discriminate between internal and external fault using the time synchronised voltages and currents of both the terminal of the transmission line. The performance of proposed scheme has been evaluated on IEEE 12 bus FACTS benchmark power system model implemented in PSCAD/EMTDC. The measured voltage & current signals are pre‐processed and phasors are estimated through DFT algorithm in MATLAB. The performance remains unaffected during wide variation in fault and system parameters including different line length and static var compensator rating. The test results confirm the selective, simplicity, high speed, sensitivity, and robustness of the proposed protection scheme. This scheme is also able to distinguish the faulty phase(s) from healthy phases, which enables the single‐pole tripping option. Finally, comparative evaluation of the proposed technique with the existing protection schemes clearly shows its superiority.
- 28 June 2017
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 11 (13) , 3406-3416
Open AccessSynchrophasors assisted protection scheme for the shunt‐compensated transmission line
This study presents synchrophasor assisted protection scheme for the protection of long transmission line compensated with shunt flexible AC transmission system (FACTS) device. With the advancement in synchrophasor technology, data communication medium, and wide area measurement system for transmission line protection, the differential protection scheme is a most suited scheme over the over‐current, distance and directional protection schemes. The proposed scheme discriminate between internal and external fault using the time synchronised voltages and currents of both the terminal of the transmission line. The performance of proposed scheme has been evaluated on IEEE 12 bus FACTS benchmark power system model implemented in PSCAD/EMTDC. The measured voltage & current signals are pre‐processed and phasors are estimated through DFT algorithm in MATLAB. The performance remains unaffected during wide variation in fault and system parameters including different line length and static var compensator rating. The test results confirm the selective, simplicity, high speed, sensitivity, and robustness of the proposed protection scheme. This scheme is also able to distinguish the faulty phase(s) from healthy phases, which enables the single‐pole tripping option. Finally, comparative evaluation of the proposed technique with the existing protection schemes clearly shows its superiority.